AIMTEC AM3G

Series AM3G-NZ
3 Watt | DC-DC Converter
FEATURES:
• RoHS compliant
• Very low no load consumption
• Remote On/Off Control
• 8 pin SIP package
•
•
•
•
Operating temperature -40oC to + 85oC
Continuous Short circuit protection
Wide 2:1 input range
High efficiency up to 81%
Models
Single output
Model
Input
Voltage (V)
Output
Voltage(V)
Output Current
max (mA)
Isolation
(VDC)
Capacitor Load
(μF)
Efficiency
(%)
9-18
9-18
9-18
9-18
18-36
18-36
18-36
18-36
5
9
12
15
5
9
12
15
600
333
250
200
600
333
250
200
1500
1500
1500
1500
1500
1500
1500
1500
2200
1000
820
680
2200
1000
820
680
78
79
80
80
78
79
80
81
AM3G-1205S-NZ
AM3G-1209S-NZ
AM3G-1212S-NZ
AM3G-1215S-NZ
AM3G-2405S-NZ
AM3G-2409S-NZ
AM3G-2412S-NZ
AM3G-2415S-NZ
Models
Dual output
Model
Input Voltage
(V)
Output
Voltage(V)
Output Current
max (mA)
Isolation
(VDC)
Capacitor Load
(μF)
Efficiency
(%)
9-18
9-18
9-18
9-18
18-36
18-36
18-36
18-36
±5
±9
±12
±15
±5
±9
±12
±15
±300
±167
±125
±100
±300
±167
±125
±100
1500
1500
1500
1500
1500
1500
1500
1500
±560
±470
±330
±220
±560
±470
±330
±220
78
79
80
80
78
79
80
81
Maximum
Units
AM3G-1205D-NZ
AM3G-1209D-NZ
AM3G-1212D-NZ
AM3G-1215D-NZ
AM3G-2405D-NZ
AM3G-2409D-NZ
AM3G-2412D-NZ
AM3G-2415D-NZ
Input Specifications
Parameters
Voltage range
Nominal
Typical
12
24
9-18
18-36
Capacitor
22
40
Filter
Maximum Rating
12 Vin
24 Vin
Peak Input Voltage time
On/Off Control
VDC
VDC
100
ms
Rated
Units
1500
VDC
MOhm
pF
Maximum
Units
ON – low or open; OFF - high
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Capacitance
Conditions
Typical
60 sec
> 1000
80
100kHz, 1V
Output Specifications
Parameters
Voltage accuracy
Voltage balance
Short Circuit protection
Short Circuit restart
www.aimtec.com
F 051e R8.C
Conditions
Typical
±3
±5
Continuous
Auto recovery
Dual Output 25~100% load
Tel: +1 514 620 2722
1 of 3
%
%
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM3G-NZ
3 Watt | DC-DC Converter
Output Specifications (continued)
Parameters
Line voltage regulation
Load voltage regulation
Temperature coefficient
Ripple & Noise
Conditions
Typical
LL~HL
load 10~100%
At 20MHz Bandwidth
±0.5
±1
±0.03
100
Conditions
Typical
Maximum
Units
%
%
%/oC
mV p-p
General Specifications
Parameters
Maximum
Units
Switching frequency
100% load
>200
500
KHz
o
Operating temperature
With derating above 71oC
-40 to +85
C
o
Storage temperature
-50 to +125
C
No load power consumption
100
mW
Cooling
Free air convection
Humidity
95
%
Case material
Non-conductive black plastic (UL94V-0 rated)
Weight
6
g
Dimensions (L x H x W)
0.87 x 0.37 x 0.47 inch
22 x 9.5 x 12 mm
MTBF
>1 000 000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC)
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Pin Out Specifications
Dimensions
Pin
Single
Dual
1
2
3
5
6
7
8
- V Input
+ V Input
On/Off Control
N.C.
+ V Output
- V Output
CS
- V Input
+ V Input
On/Off Control
N.C.
+ V Output
Common
- V Output
22.00
(0.87)
PRINTED
FACE
12.00
(0.47)
12.00
(0.47)
0.50
(0.02)
Derating
4.10
(0.16)
2.54
(0.10)
Free Air Convection
9.50
(0.37)
0.50
(0.02)
71º C
100
80
60
2.50
(0.98)
Safe Operating Area
1
2
3
2.10
(0.08)
5
6
7
8
0.300
(0.012)
9.50
(0.37)
0.50
(0.02)
40
20
0
- 40
- 20
0
20
40
60
80
85
100
Ambient Temperature º C
www.aimtec.com
F 051e R8.C
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM3G-NZ
3 Watt | DC-DC Converter
CS Capacitor Table
Vout
CS
5V
9V
47uF – 100uF
12V
15V
24V
10uF – 47uF
Control ON/OFF pin connection example:
The voltage could be applied through a limiting resistor and a switching diode. The converter is in a low power mode during
high level phase.
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R8.C
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only