Series AM3G-NZ 3 Watt | DC-DC Converter FEATURES: • RoHS compliant • Very low no load consumption • Remote On/Off Control • 8 pin SIP package • • • • Operating temperature -40oC to + 85oC Continuous Short circuit protection Wide 2:1 input range High efficiency up to 81% Models Single output Model Input Voltage (V) Output Voltage(V) Output Current max (mA) Isolation (VDC) Capacitor Load (μF) Efficiency (%) 9-18 9-18 9-18 9-18 18-36 18-36 18-36 18-36 5 9 12 15 5 9 12 15 600 333 250 200 600 333 250 200 1500 1500 1500 1500 1500 1500 1500 1500 2200 1000 820 680 2200 1000 820 680 78 79 80 80 78 79 80 81 AM3G-1205S-NZ AM3G-1209S-NZ AM3G-1212S-NZ AM3G-1215S-NZ AM3G-2405S-NZ AM3G-2409S-NZ AM3G-2412S-NZ AM3G-2415S-NZ Models Dual output Model Input Voltage (V) Output Voltage(V) Output Current max (mA) Isolation (VDC) Capacitor Load (μF) Efficiency (%) 9-18 9-18 9-18 9-18 18-36 18-36 18-36 18-36 ±5 ±9 ±12 ±15 ±5 ±9 ±12 ±15 ±300 ±167 ±125 ±100 ±300 ±167 ±125 ±100 1500 1500 1500 1500 1500 1500 1500 1500 ±560 ±470 ±330 ±220 ±560 ±470 ±330 ±220 78 79 80 80 78 79 80 81 Maximum Units AM3G-1205D-NZ AM3G-1209D-NZ AM3G-1212D-NZ AM3G-1215D-NZ AM3G-2405D-NZ AM3G-2409D-NZ AM3G-2412D-NZ AM3G-2415D-NZ Input Specifications Parameters Voltage range Nominal Typical 12 24 9-18 18-36 Capacitor 22 40 Filter Maximum Rating 12 Vin 24 Vin Peak Input Voltage time On/Off Control VDC VDC 100 ms Rated Units 1500 VDC MOhm pF Maximum Units ON – low or open; OFF - high Isolation Specifications Parameters Tested I/O voltage Resistance Capacitance Conditions Typical 60 sec > 1000 80 100kHz, 1V Output Specifications Parameters Voltage accuracy Voltage balance Short Circuit protection Short Circuit restart www.aimtec.com F 051e R8.C Conditions Typical ±3 ±5 Continuous Auto recovery Dual Output 25~100% load Tel: +1 514 620 2722 1 of 3 % % Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM3G-NZ 3 Watt | DC-DC Converter Output Specifications (continued) Parameters Line voltage regulation Load voltage regulation Temperature coefficient Ripple & Noise Conditions Typical LL~HL load 10~100% At 20MHz Bandwidth ±0.5 ±1 ±0.03 100 Conditions Typical Maximum Units % % %/oC mV p-p General Specifications Parameters Maximum Units Switching frequency 100% load >200 500 KHz o Operating temperature With derating above 71oC -40 to +85 C o Storage temperature -50 to +125 C No load power consumption 100 mW Cooling Free air convection Humidity 95 % Case material Non-conductive black plastic (UL94V-0 rated) Weight 6 g Dimensions (L x H x W) 0.87 x 0.37 x 0.47 inch 22 x 9.5 x 12 mm MTBF >1 000 000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC) NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Pin Out Specifications Dimensions Pin Single Dual 1 2 3 5 6 7 8 - V Input + V Input On/Off Control N.C. + V Output - V Output CS - V Input + V Input On/Off Control N.C. + V Output Common - V Output 22.00 (0.87) PRINTED FACE 12.00 (0.47) 12.00 (0.47) 0.50 (0.02) Derating 4.10 (0.16) 2.54 (0.10) Free Air Convection 9.50 (0.37) 0.50 (0.02) 71º C 100 80 60 2.50 (0.98) Safe Operating Area 1 2 3 2.10 (0.08) 5 6 7 8 0.300 (0.012) 9.50 (0.37) 0.50 (0.02) 40 20 0 - 40 - 20 0 20 40 60 80 85 100 Ambient Temperature º C www.aimtec.com F 051e R8.C Tel: +1 514 620 2722 2 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM3G-NZ 3 Watt | DC-DC Converter CS Capacitor Table Vout CS 5V 9V 47uF – 100uF 12V 15V 24V 10uF – 47uF Control ON/OFF pin connection example: The voltage could be applied through a limiting resistor and a switching diode. The converter is in a low power mode during high level phase. NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R8.C Tel: +1 514 620 2722 3 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only