Series AM4N-Z 4 Watt | DC-DC Converter FEATURES: Operating temperature -40oC to + 85oC 5KVAC highest reinforced input/ output isolation Pin compatible with multiple manufacturers Continuous short circuit protection RoHS compliant ±20% Input voltage range Low ripple and noise High efficiency up to 81% Models Single output Model Input Voltage (V) Output Voltage (V) Output Current max (mA) Isolation (VAC) Efficiency (%) 4-6 4-6 4-6 4-6 9.6-14.4 9.6-14.4 9.6-14.4 9.6-14.4 3.3 5 12 15 3.3 5 12 15 700 700 291 233 700 700 291 233 5000 5000 5000 5000 5000 5000 5000 5000 74 78 80 79 76 80 81 81 AM4N-0503SH50Z AM4N-0505SH50Z AM4N-0512SH50Z AM4N-0515SH50Z AM4N-1203SH50Z AM4N-1205SH50Z AM4N-1212SH50Z AM4N-1215SH50Z NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Voltage range Nominal Typical 5 12 Filter Start up time Absolute Maximum Rating Maximum 4-6 9.6-14.4 Capacitors 75 0-7 0-15 80 35 5 Vin 12 Vin No Load Input Current Input reflected current(pk-pk) Units VDC ms VDC 115 mA mA Maximum Units Isolation Specifications Parameters Tested I/O voltage Resistance Capacitance Conditions Typical 3 sec 5000 1000 50 VAC MOhm pF Output Specifications Parameters Voltage accuracy Short Circuit protection Short circuit restart Short Circuit consumption Line voltage regulation Load voltage regulation Temperature coefficient Ripple & Noise Minimum Load Current Conditions Typical Maximum ±2 Continuous Autorecovery % ±0.2 ±0.5 ±0.02 85 10 From 10% to 100% Load 20MHz Bandwidth Units W % of Vin % %/oC mV p-p % of Max General Specifications Parameters Switching frequency Operating temperature Storage temperature www.aimtec.com F 051e R12 Conditions 100% load Typical 570 -40 to +85 (full load without derating) -55 to +125 Tel: +1 514 620 2722 1 of 4 Maximum Units KHz o C o C Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM4N-Z 4 Watt | DC-DC Converter General Specifications (continued) Parameters Conditions Maximum case temperature Derating Cooling Humidity Case material Weight Dimensions (L x W x H) MTBF Maximum soldering temperature Typical Maximum Units o 100 None 1.5mm from case for 10sec C %/ oC Natural Convection 95 Non Conductive Black Plastic (UL94V-0 rated) 12.5 1.25 x 0.80 x 0.40 inches 31.75 x 20.32 x 10.16 mm > 1 000 000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC) 260 % RH g o C Safety Specifications Parameters Agency Approvals Standards CE EN 55022 Class A EN 55024 IEC 61000-4-2 IEC 61000-4-3 IEC 61000-4-4 IEC 61000-4-5 IEC 61000-4-6 IEC 61000-4-8 NOTE: also designed to meet IEC 60601-1 Pin Out Specifications Pin Single 2 3 11 14 16 22 23 -V Input -V Input N.C. +V Output -V Output V+ Input V+ Input N.C.: No connection www.aimtec.com F 051e R12 Tel: +1 514 620 2722 2 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM4N-Z 4 Watt | DC-DC Converter Dimensions EMI Solution www.aimtec.com F 051e R12 Tel: +1 514 620 2722 3 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM4N-Z 4 Watt | DC-DC Converter EFT/Surge Solution NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5.Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R12 Tel: +1 514 620 2722 4 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only