AIMTEC AMEL20

Series AMEL20-MAZ
20 Watt | AC-DC Converter
FEATURES:
• I/O Isolation 4000VAC
• Operating Temp: -40 oC to +80 oC
• Over load, Over Voltage, Short Circuit Protection
• Up to 82% efficiency
•
•
•
Energy Star compliant
Ultra small package
Soft start
CB
Models
Single output
Maximum
capacitive
load
(µF)
Efficiency
(%)
5600
4700
3300
2200
1000
74
78
82
82
82
Rated
Output
Current (A)
Maximum
capacitive
load
(µF)
Efficiency
(%)
3.3/5
3.3/12
3.3/15
3.3/24
5/12
5/15
5/24
12/15
12/24
15/24
1.4/2.5
1.4/1.1
1.4/0.89
1.4/0.55
1.6/0. 83
1.6/0.66
1.6/0.46
0.66/0.66
0.58/0. 42
0.54/0. 42
1000
1000
1000
1000
680
680
680
560
560
560
75
78
77
76
76
78
76
77
79
80
-3.3/5
-3.3/12
-3.3/15
-5/5
-5/12
-5/15
-12/12
-12/15
-0.7/2.5
-1.4/1.1
-1.4/0.89
-0.8/2
-1.6/0. 83
-1.6/0.66
-0.66/0.83
-0.66/0.66
680
680
680
680
470
470
470
330
75
76
76
75
75
75
77
76
Input Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Max Output
wattage (W)
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
120-370
120-370
120-370
120-370
120-370
13.2
20
20
20
20
Input Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Max Output
wattage (W)
Output
Voltage
(V)
AMEL20-3.35DMAZ
AMEL20-3.312DMAZ
AMEL20-3.315DMAZ
AMEL20-3.324DMAZ
AMEL20-512DMAZ
AMEL20-515DMAZ
AMEL20-524DMAZ
AMEL20-1215DMAZ
AMEL20-1224DMAZ
AMEL20-1524DMAZ
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
120-370
120-370
120-370
120-370
120-370
120-370
120-370
120-370
120-370
120-370
17.5
18
18
18
18
18
18
18
18
18
AMEL20-3.3N5DMAZ
AMEL20-3.3N12DMAZ
AMEL20-3.3N15DMAZ
AMEL20-5N5DMAZ
AMEL20-5N12DMAZ
AMEL20-5N15DMAZ
AMEL20-12N12DMAZ
AMEL20-12N15DMAZ
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
120-370
120-370
120-370
120-370
120-370
120-370
120-370
120-370
14.8
18
18
14
18
18
18
18
Model
AMEL20-3.3SMAZ
AMEL20-5SMAZ
AMEL20-12SMAZ
AMEL20-15SMAZ
AMEL20-24SMAZ
Output
Voltage(V)
3.3
5
12
15
24
Output
Current max
(A)
4
4
1.66
1.33
0.84
Models
Asymmetric Dual output
Model
*Output power must not exceed the listed values.
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Current
Inrush current <2ms (cold start)
Leakage current
External fuse
www.aimtec.com
F 052e R8.H
Conditions
Typical
115VAC
230VAC
115VAC
230VAC
0.46
0.29
slow blow type
1.5
Maximum
10
20
0.25
Tel: +1 514 620 2722
1 of 4
Units
A
A
A
A
mA
A
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEL20-MAZ
20 Watt | AC-DC Converter
Input Specifications (continued)
Parameters
Input dissipation
Start up time
Conditions
Typical
No Load
Soft start
<0.5
500
Conditions
Typical
Maximum
Units
W
ms
Output Specifications
Parameters
Voltage accuracy
Line regulation
Load regulation (single output)
Load regulation (dual output)
Transient recovery time
Transient response deviation
Ripple & Noise*
Hold-up time (min)
Maximum
±2
±1
±2
±3
500
±2
75
100
10
25
0-100% load
Unbalanced (0-100%) load
25% load step
3.3 & 5V models
12, 15 & 24V models
110VAC
230VAC
Units
%
%
%
%
µs
% of Vout
mV p-p
ms
*Ripple and Noise are measured at 20MHz bandwidth by using a 0.1μF (M/C) parallel capacitor.
Isolation Specifications
Parameters
Tested I/O voltage
Isolation resistance
Isolation Capacitance
Conditions
Typical
3 sec, 1.2mA
Rated
Units
4000
VAC
MΩ
pF
Maximum
Units
>1000
2200
General Specifications
Parameters
Switching frequency
Over load protection
Over voltage protection
Short circuit protection
Short circuit restart
Operating temperature
Maximum case temperature
Storage temperature
Temperature coefficient
Cooling
Humidity
Case material
Weight
Dimensions (L x W x H)
MTBF
Conditions
Typical
100% load
Auto recovery, Foldback
65
150
Zener Diode Clamp
Continuous
Auto recovery
-40 to 80
With derating above 50ºC
KHz
%
o
C
C
o
C
% / oC
o
100
-45 to +95
±0.02
Free air convection
Non condensing
20 ~ 95
Plastic resin + Fiberglass (flammability to UL 94V-0)
70
2.22 x 1.21 x 0.99 inches
56.48 x 30.86 x 25.10mm
> 400 000 hrs (MIL-HDBK -217F, t=+25oC)
% RH
g
Environment Approval
Test
Shock
Vibration
Parameters
Wave form
Acceleration amplitude
Bump duration
Converter operation
Number of bumps
Test mode
Displacement
Acceleration
Conditions
Half sine wave
5gn
30 ms
before and after test, body mounted (on chassis)
18 (3 in each direction for every axis)
Sweep sine
1mm
3g
10-100Hz, speed 0.05Hz/s
Converter operation
www.aimtec.com
F 052e R8.H
Tel: +1 514 620 2722
2 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEL20-MAZ
20 Watt | AC-DC Converter
Safety Specifications
Parameters
Agency approvals
Standards
cULus, CE, CB
Medical Electrical Equipment
Information technology Equipment
EMI - Conducted and radiated emission
Harmonic Current Emissions
Voltage fluctuations and flicker
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient/Burst Immunity
Surge Immunity
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field Immunity
Voltage dips, Short Interruptions Immunity
IEC\EN\UL 60601-1, CSA-C22.2 No. 601.1-M90
EN 60950-1:2006+A11:2009
EN55011, class B
IEC/EN 61000-3-2, (EN60555-2)
IEC/EN 61000-3-3, (EN60555-3)
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-11
Pin Out Specifications
Pin
Single
Dual positive
Dual negative/positive
1
2
3
4
5
AC Input (N)
AC Input (L)
+V Output
-V Output
No pin
AC Input (N)
AC Input (L)
+V1 Output
Common
+V2 Output
AC Input (N)
AC Input (L)
+V1 Output
Common
-V2 Output
10.20
(0.40)
10.20
(0.40)
20.40
(0.80)
8.00
(0.31)
25.10
(0.99)
5,27
(0.21)
30.86
(1.21)
5.27
(0.21)
Dimensions
www.aimtec.com
F 052e R8.H
Tel: +1 514 620 2722
3 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEL20-MAZ
20 Watt | AC-DC Converter
Derating
Free Air Convection
50?C
Output Power (%)
100
80
Safe Operating Area
60
40
20
0
- 40
- 20
0
20
40
60
80
85
100
Ambient Temperature ?C
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer
controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may
vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of
25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis
on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be
available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other
such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard
Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 052e R8.H
Tel: +1 514 620 2722
4 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only