AIMTEC AMEL20

Series AMEL20-AZ
Preliminary
20 Watt | AC-DC / DC-DC Converter
FEATURES:
• I/O Isolation 3000VAC
• Operating Temp: -40 oC to +80 oC
• Over load, Over Voltage, Short Circuit Protection
• Up to 81% efficiency
•
•
•
Energy Star compliant
Ultra small package
Models
Single output
Model
AMEL20-3.3SAZ
AMEL20-5SAZ
AMEL20-12SAZ
AMEL20-15SAZ
AMEL20-24SAZ
Input Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Max Output
wattage (W)
90-305/47-440
90-305/47-440
90-305/47-440
90-305/47-440
90-305/47-440
120-430
120-430
120-430
120-430
120-430
13.2
20
20
20
20
Input Specifications
Parameters
Current
Inrush current <2ms (cold start)
Leakage current
External fuse
Input dissipation
Output Specifications
Parameters
Voltage accuracy
Line regulation
Load regulation (single output)
Transient recovery time
Transient response deviation
Ripple & Noise*
Output
Voltage(V)
Conditions
3.3
5
12
15
24
Parameters
Tested I/O voltage
Isolation Resistance
www.aimtec.com
F 052e R8
4
4
1.66
1.33
0.84
Typical
115VAC
230VAC
115VAC
230VAC
0.46
0.29
slow blow type
No Load
1.5
<0.5
Conditions
Typical
0-100% load
25% load step
20MHz bandwidth
*Ripple and Noise are measured at 20MHz bandwidth by using a 0.1μF (M/C) parallel capacitor.
Isolation Specifications
Output
Current max
(A)
Conditions
±2
±1
±2
500
±2
100
Typical
3sec
>1000
Tel: +1 514 620 2722
1 of 3
Maximum
capacitive
load
(µF)
Efficiency
(%)
5600
4700
3300
2200
1000
Maximum
10
20
0.25
Maximum
Rated
3000
73
77
81
81
81
Units
A
A
A
A
mA
A
W
Units
%
%
%
µs
% of Vout
mV p-p
Units
VAC
MΩ
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEL20-AZ
Preliminary
General Specifications
Parameters
20 Watt | AC-DC / DC-DC Converter
Conditions
Typical
Maximum
Units
Switching frequency
66
KHz
Over load protection
Auto recovery, Fold back
150
%
Over voltage protection
Zener Diode Clamp
Short circuit protection
Auto recovery
o
Operating temperature
With derating above 40ºC
-40 to 80
C
o
Maximum case temperature
100
C
o
Storage temperature
-45 to +95
C
Temperature coefficient
±0.02
% / oC
Humidity
Non condensing
20 ~ 95
% RH
Case material
Plastic resin + Fiberglass (flammability to UL 94V-0)
Weight
70
g
Dimensions (L x W x H)
2.22 x 1.21 x 0.99 inches
56.48 x 30.86 x 25.10mm
MTBF
> 400 000 hrs (MIL-HDBK -217F, t=+25oC)
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Environment Approval
Test
Shock
Vibration
Parameters
Wave form
Acceleration amplitude
Bump duration
Converter operation
Number of bumps
Test mode
Displacement
Acceleration
Conditions
Half sine wave
5gn
30 ms
before and after test, body mounted (on chassis)
18 (3 in each direction for every axis)
Sweep sine
1mm
3g
10-100Hz, speed 0.05Hz/s
Converter operation
Safety Specifications
Parameters
Information technology Equipment
EMI - Conducted and radiated emission
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient/Burst Immunity
Surge Immunity
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field Immunity
Voltage dips, Short Interruptions Immunity
Information Technology Equipment
Information Technology Equipment
Standards
EN 60950-1:2006+A11:2009
EN55011, class B
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-11
UL 60950-1:2007
CAN/CSA-C22.2 No.60950-1-07
Pin Out Specifications
Pin
1
2
3
4
5
Single
AC Input (N)
AC Input (L)
+V Output
-V Output
No pin
www.aimtec.com
F 052e R8
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Preliminary
Dimensions
5.27
(0.21)
Top View 4
2
5
5.37
(0.21)
1
10.20
(0.40)
3
10.20
(0.40)
45.72
(1.80)
1
5,27
(0.21)
20 Watt | AC-DC / DC-DC Converter
56.46
(2.22)
20.40
(0.80)
30.86
(1.21)
Series AMEL20-AZ
2
5.37
(0.21)
3
Top View 4
5
25.10
(0.99)
DIV: 10.00 (0.40)
8.00
(0.31)
5Ø 1.0 (Ø 0.04)
Dimensions mm (inch)
Case Tolerance ±0.50 (±0.02)
Pin Diameter 1.0 ± 0.05 (0.04 ± 0.002)
Pin Pitch Tolerance ±0.35 (±0.014)
1.05
(0.04)
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer
controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary
based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C,
humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all
internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for
release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications
which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available
at www.aimtec.com.
www.aimtec.com
F 052e R8
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only