AIMTEC AMEL5

Series AMEL5-MAZ
5 Watt | AC-DC Converter
FEATURES:
•
•
•
•
I/O Isolation 4000VAC
Operating Temp: -40 oC to +80 oC or -25 oC to +80 oC
Input: 90-260VAC, 47-440Hz, or 120-370VDC
Over load, Over Voltage, Short Circuit Protection
•
•
•
•
RoHS compliant
Energy Star compliant
Ultra small package
Soft start
CB
Models
Single output
Model
Input Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Temperature
range
(ºC)
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
120-370
120-370
120-370
120-370
120-370
120-370
120-370
120-370
120-370
120-370
-25 to +80
-25 to +80
-25 to +80
-25 to +80
-25 to +80
-40 to +80
-40 to +80
-40 to +80
-40 to +80
-40 to +80
Input Voltage
(VAC, Hz)
Input
Voltage
(VDC)
Temperature
range
(ºC)
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
120-370
120-370
120-370
120-370
120-370
120-370
-25 to +80
-25 to +80
-25 to +80
-40 to +80
-40 to +80
-40 to +80
AMEL5-3.3SMAZ
AMEL5-5SMAZ
AMEL5-12SMAZ
AMEL5-15SMAZ
AMEL5-24SMAZ
AMEL5-3.3SEMAZ
AMEL5-5SEMAZ
AMEL5-12SEMAZ
AMEL5-15SEMAZ
AMEL5-24SEMAZ
Maximum
capacitive
Load
(µF)
Efficiency
(%)
1. 5
1
0.42
0.333
0.21
1. 5
1
0.42
0.333
0.21
2200
1100
680
330
220
2200
1100
680
330
220
68
70
73
73
75
68
70
73
73
75
Output
Voltage
(V)
Output
Current max
(A)
Maximum
capacitive
load
(µF)
Efficiency
(%)
±5
±12
±15
±5
±12
±15
±0.5
±0.21
±0.168
±0.5
±0.21
±0.168
±470
±220
±150
±470
±220
±150
72
73
75
72
73
75
Output
Voltage
(V)
Output
Current max
(A)
3.3
5
12
15
24
3.3
5
12
15
24
Models
Dual output
Model
AMEL5-5DMAZ
AMEL5-12DMAZ
AMEL5-15DMAZ
AMEL5-5DEMAZ
AMEL5-12DEMAZ
AMEL5-15DEMAZ
Input Specifications
Parameters
Current (full load)
Inrush current <2ms (cold start)
Leakage current
External fuse
Input Dissipation (No Load)
Start up time
Under Voltage Protection
www.aimtec.com
F 052e R8.H
Conditions
Typical
115 VAC
230 VAC
115 VAC
230 VAC
Maximum
120
70
10
20
0.2
Recommended slow blow type
Soft Start
Tel: +1 514 620 2722
1 of 4
1.5
<0.3
15
89
Units
mA
mA
A
A
mA
A
W
mS
VAC
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEL5-MAZ
5 Watt | AC-DC Converter
Output Specifications
Parameters
Voltage accuracy
Line regulation
Load regulation (single output)
Cross Regulation (dual output)
Transient Recovery Time
Transient Response Deviation
Minimum load
Ripple & Noise
Hold-up time (minimum)
Conditions
Typical
0-100% load
st
nd
25% load - 1 out, 100% load – 2 out
25% load step
20MHz bandwidth
Maximum
±2
±0.5
±0.5
±5
200
±2
0
100
15
Units
%
%
%
%
µs
% of Vout
%
mV p-p
ms
Isolation Specifications
Parameters
Tested I/O voltage
Isolation Resistance
Conditions
Typical
3sec
Rated
Units
4000
VAC
MΩ
Maximum
Units
>1000
General Specifications
Parameters
Conditions
Typical
Switching frequency
132
KHz
Start up time
900
mS
Over Load protection
Auto recovery, hiccup mode
>116%
Over voltage protection
Zener diode clamp
Short circuit protection
Continuous
Short Circuit restart
Auto recovery
o
Operating temperature
With derating above 50ºC
Refer to the models table above
C
o
Storage temperature
-40 to +95
C
o
Maximum Case temperature
100
C
Temperature coefficient
0.02
% / oC
Cooling
Free air convection
Humidity
Non condensing
20 ~ 95
% RH
Case material
Plastic resin + Fiberglass (flammability to UL 94V-0)
Weight
30
g
Dimensions (L x W x H)
2.03 x 1.10 x 0.70 inches 51.5 x 28 x 17.8mm
MTBF
> 400 000 hrs (MIL-HDBK -217F, t=+25oC)
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Environment Approval
Parameters
Shock
Vibrations
Conditions
Wave form: Half sine wave
Acceleration amplitude: 5gn
Bump duration: 30 ms
Number of bumps: 18 (3 in each direction for every axis)
Converter operation before and after test, body mounted (on chassis)
Test mode: Sweep sine
10-100Hz, speed 0.05Hz/s
Displacement: 1mm
Acceleration: 3g
3 loops 30min one cycle, 3h total, every axis tested
Converter operation before and after test, body mounted (on chassis)
www.aimtec.com
F 052e R8.H
Tel: +1 514 620 2722
2 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEL5-MAZ
5 Watt | AC-DC Converter
Safety Specifications
Parameters
Agency approvals
cULus, CE, CB
Medical Electrical Equipment
Information technology Equipment
EMI - Conducted and radiated emission
Harmonic Current Emissions
Voltage fluctuations and flicker
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient/Burst Immunity
Surge Immunity
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field Immunity
Voltage dips, Short Interruptions Immunity
Standards
IEC\EN\UL 60601-1, CSA-C22.2 No. 601.1-M90
EN 60950-1:2006+A11:2009
EN55011, class B
IEC/EN 61000-3-2, (EN60555-2)
IEC/EN 61000-3-3, (EN60555-3)
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-11
Pin Out Specifications
Pin
Single
Dual
1
2
3
4
5
AC Input (N)
AC Input (L)
+V Output
-V Output
No pin
AC Input (N)
AC Input (L)
+V Output
Common
-V Output
Dimensions
2.03
(51.50)
1.80
(45.72)
1
1
3
3
0.40
(10.16)
1.10
0.80
(28.00) (20.32)
TOP VIEW
TOP VIEW
4
4
0.40
(10.16)
2
2
5
5
0.11
(2.89)
17.80
(0.70)
5 Ø- 0.047 (? 1.2)
? 0.04
(1.00)
0.2
(5.08)
(Min)
www.aimtec.com
F 052e R8.H
Tel: +1 514 620 2722
3 of 4
DIV: 0.2 (5.08)
Dimensions: inch (mm)
Case Tolerance:? 0.012 (0.30)
Pin Pitch Tolerance: ? 0.012 (0.30)
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEL5-MAZ
5 Watt | AC-DC Converter
Derating
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 052e R8.H
Tel: +1 514 620 2722
4 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only