Series AMEL5-MAZ 5 Watt | AC-DC Converter FEATURES: • • • • I/O Isolation 4000VAC Operating Temp: -40 oC to +80 oC or -25 oC to +80 oC Input: 90-260VAC, 47-440Hz, or 120-370VDC Over load, Over Voltage, Short Circuit Protection • • • • RoHS compliant Energy Star compliant Ultra small package Soft start CB Models Single output Model Input Voltage (VAC/Hz) Input Voltage (VDC) Temperature range (ºC) 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 120-370 120-370 120-370 120-370 120-370 120-370 120-370 120-370 120-370 120-370 -25 to +80 -25 to +80 -25 to +80 -25 to +80 -25 to +80 -40 to +80 -40 to +80 -40 to +80 -40 to +80 -40 to +80 Input Voltage (VAC, Hz) Input Voltage (VDC) Temperature range (ºC) 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 120-370 120-370 120-370 120-370 120-370 120-370 -25 to +80 -25 to +80 -25 to +80 -40 to +80 -40 to +80 -40 to +80 AMEL5-3.3SMAZ AMEL5-5SMAZ AMEL5-12SMAZ AMEL5-15SMAZ AMEL5-24SMAZ AMEL5-3.3SEMAZ AMEL5-5SEMAZ AMEL5-12SEMAZ AMEL5-15SEMAZ AMEL5-24SEMAZ Maximum capacitive Load (µF) Efficiency (%) 1. 5 1 0.42 0.333 0.21 1. 5 1 0.42 0.333 0.21 2200 1100 680 330 220 2200 1100 680 330 220 68 70 73 73 75 68 70 73 73 75 Output Voltage (V) Output Current max (A) Maximum capacitive load (µF) Efficiency (%) ±5 ±12 ±15 ±5 ±12 ±15 ±0.5 ±0.21 ±0.168 ±0.5 ±0.21 ±0.168 ±470 ±220 ±150 ±470 ±220 ±150 72 73 75 72 73 75 Output Voltage (V) Output Current max (A) 3.3 5 12 15 24 3.3 5 12 15 24 Models Dual output Model AMEL5-5DMAZ AMEL5-12DMAZ AMEL5-15DMAZ AMEL5-5DEMAZ AMEL5-12DEMAZ AMEL5-15DEMAZ Input Specifications Parameters Current (full load) Inrush current <2ms (cold start) Leakage current External fuse Input Dissipation (No Load) Start up time Under Voltage Protection www.aimtec.com F 052e R8.H Conditions Typical 115 VAC 230 VAC 115 VAC 230 VAC Maximum 120 70 10 20 0.2 Recommended slow blow type Soft Start Tel: +1 514 620 2722 1 of 4 1.5 <0.3 15 89 Units mA mA A A mA A W mS VAC Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEL5-MAZ 5 Watt | AC-DC Converter Output Specifications Parameters Voltage accuracy Line regulation Load regulation (single output) Cross Regulation (dual output) Transient Recovery Time Transient Response Deviation Minimum load Ripple & Noise Hold-up time (minimum) Conditions Typical 0-100% load st nd 25% load - 1 out, 100% load – 2 out 25% load step 20MHz bandwidth Maximum ±2 ±0.5 ±0.5 ±5 200 ±2 0 100 15 Units % % % % µs % of Vout % mV p-p ms Isolation Specifications Parameters Tested I/O voltage Isolation Resistance Conditions Typical 3sec Rated Units 4000 VAC MΩ Maximum Units >1000 General Specifications Parameters Conditions Typical Switching frequency 132 KHz Start up time 900 mS Over Load protection Auto recovery, hiccup mode >116% Over voltage protection Zener diode clamp Short circuit protection Continuous Short Circuit restart Auto recovery o Operating temperature With derating above 50ºC Refer to the models table above C o Storage temperature -40 to +95 C o Maximum Case temperature 100 C Temperature coefficient 0.02 % / oC Cooling Free air convection Humidity Non condensing 20 ~ 95 % RH Case material Plastic resin + Fiberglass (flammability to UL 94V-0) Weight 30 g Dimensions (L x W x H) 2.03 x 1.10 x 0.70 inches 51.5 x 28 x 17.8mm MTBF > 400 000 hrs (MIL-HDBK -217F, t=+25oC) NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Environment Approval Parameters Shock Vibrations Conditions Wave form: Half sine wave Acceleration amplitude: 5gn Bump duration: 30 ms Number of bumps: 18 (3 in each direction for every axis) Converter operation before and after test, body mounted (on chassis) Test mode: Sweep sine 10-100Hz, speed 0.05Hz/s Displacement: 1mm Acceleration: 3g 3 loops 30min one cycle, 3h total, every axis tested Converter operation before and after test, body mounted (on chassis) www.aimtec.com F 052e R8.H Tel: +1 514 620 2722 2 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEL5-MAZ 5 Watt | AC-DC Converter Safety Specifications Parameters Agency approvals cULus, CE, CB Medical Electrical Equipment Information technology Equipment EMI - Conducted and radiated emission Harmonic Current Emissions Voltage fluctuations and flicker Electrostatic Discharge Immunity RF, Electromagnetic Field Immunity Electrical Fast Transient/Burst Immunity Surge Immunity RF, Conducted Disturbance Immunity Power frequency Magnetic Field Immunity Voltage dips, Short Interruptions Immunity Standards IEC\EN\UL 60601-1, CSA-C22.2 No. 601.1-M90 EN 60950-1:2006+A11:2009 EN55011, class B IEC/EN 61000-3-2, (EN60555-2) IEC/EN 61000-3-3, (EN60555-3) IEC 61000-4-2 IEC 61000-4-3 IEC 61000-4-4 IEC 61000-4-5 IEC 61000-4-6 IEC 61000-4-8 IEC 61000-4-11 Pin Out Specifications Pin Single Dual 1 2 3 4 5 AC Input (N) AC Input (L) +V Output -V Output No pin AC Input (N) AC Input (L) +V Output Common -V Output Dimensions 2.03 (51.50) 1.80 (45.72) 1 1 3 3 0.40 (10.16) 1.10 0.80 (28.00) (20.32) TOP VIEW TOP VIEW 4 4 0.40 (10.16) 2 2 5 5 0.11 (2.89) 17.80 (0.70) 5 Ø- 0.047 (? 1.2) ? 0.04 (1.00) 0.2 (5.08) (Min) www.aimtec.com F 052e R8.H Tel: +1 514 620 2722 3 of 4 DIV: 0.2 (5.08) Dimensions: inch (mm) Case Tolerance:? 0.012 (0.30) Pin Pitch Tolerance: ? 0.012 (0.30) Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEL5-MAZ 5 Watt | AC-DC Converter Derating NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 052e R8.H Tel: +1 514 620 2722 4 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only