Moeller NK2528-1024GB 3 easy Control Relay Description easy control relay SIMPLY easy – Clever switching and controlling easy is a compact, user-friendly control relay for simple control applications. Applications range from building and domestic automation to machine and plant control. easy has built-in user-friendly operating elements and an LCD display. Just connect up easy and draw your circuit diagram on the display by pressing the buttons. easy works with make contacts, break contacts, and relays. Enter your circuit diagram in easy just like you sketched it on paper. easy has basic and special functions for relay and contactor controls, and lots more. You can make changes to your circuit just by pressing the buttons. Time consuming rewiring is not necessary. SIMPLY easy – Applications everywhere • Building and domestic automation, controllers for lighting, doors, window shutters... • Controls for ventilators, rotating doors, greenhouses, exterior lighting, window controllers, shop display lighting control... • Controls for temperature, ventilation and brightness levels... • Controls for machines and plant, presses, conveyor belts, oscillating conveyors, sorters, pumps... SIMPLY easy – Open for change The easy circuit diagram can be entered and modified just by pressing the buttons. S1 K1 S4 S6 S5 T1 T1 K1 K2 T1 SIMPLY easy – Everything built in (some features depend on the type) • An LCD display for showing the circuit diagram • Operation buttons for wiring, value entry or switching • 4 relay outputs with max. 10 A output current or 0.5 A transistor outputs up to 2 A, suitable for parallel connection • Circuit diagrams can be created with make contacts, break contacts, relays, series and parallel circuits • Voltage supply (24 V DC or 115/230 V AC) • 8/12 digital inputs, expandable to 24 digital inputs (115/230 V AC or 24 V DC) • 2 analog inputs (DC models only, two digital inputs can also be used for analog signals) • Non-volatile circuit diagram and parameter memory (EEPROM) (retentive data) (EEPROM) • Display of message texts, setpoint and actual values for timers, counters, time and analog values • Socket for external memory card or PC interface cable • Time switch with time and weekday(s) • DST setting (summer time/winter time change) • Protect your circuit diagram and settings against unauthorized changes with a password to protect your know-how • Optional debounce (input delay) function (reliable switching with fast signals) • Selectable menu languages, 5 and 10 languages (D, GB, F, I, E, for EASY600 also P, NL, S, PL,TR) • 4 cursor buttons can also be used as input contacts in the easy circuit diagra (built in manual operation mode) • Local or remote expansion of inputs and outputs. Remote expansion by means of two wire cable up to 30 m between basic unit and expansion unit • Large ambient temperature range from –25 °C to +55 °C 4 Moeller NK2528-1024GB easy Control Relay Description SIMPLY easy – Compact and practical easy has a 45 mm as a standard dimension (4/6 space units) for installing in standard domestic distribution panels. easy can be clipped to a top-hat rail or screwed to a mounting plate for rugged environments. easy’s dimensions are 71.5 X 90 X 53 mm or 107.5 X 90 X 53 mm. Simply network Connect easy to a data bus as simply as you can expand it. Connect the expansion unit for the AS-Interface and easy can already communicate with the bus master via the AS-Interface. PROFIBUS-DP is just as simple. easy is always a slave on the bus. Example: Remote coupling with EASY200-EASY to a two wire cable PC software You can also create easy programs on a PC and download them to easy with the optional PC interface cable. Create, store, simulate and document the circuit diagram offline. Three display formats are available: DIN EN, ANSI or the easy display. SIMPLY easy – More than 20 functions in a single device • Interconnect make contacts and break contacts • 3 contacts can be connected in series • Up to 41 circuits (121 for EASY600) can be connected in parallel • Switch relay coils • Create switching functions such changeover switches, self-latching relays, single pulse relays, start-delta starters • Create timing functions such as on-delayed, on-delayed with random switching, off-delayed, off-delayed with random switching, single pulse, flashing, up/down counter • Time switch • Compare analog values • Output texts, setpoint and actual values • Store retentively the actual values of timing relays, counters, markers, operating hours counters. Simply expand Connect the expansion unit to the basic unit using the connector to add up to 24 inputs and 16 outputs. The coupling device enables the expansion unit to be expanded up to 30 m away. 5 Moeller NK2528-1024GB easy Control Relay Basic Units, Expansion Units Type Article No. Price See Price List Std. pack Basic Units 24 V DC, Retentive DEL ESC • 8 digital inputs (2 inputs also usable as analog inputs) • 4 relay outputs • LCD display • Operating buttons • Screw terminals Features as per EASY 412-DC-R plus built-in time switch Features as per EASY412-DC-RC, without keypad an LCD display • 8 digital inputs (2 inputs also usable as analog inputs) • 4 transistor outputs • LCD display • Operating buttons • Screw terminals • Time switch Features as per EASY412-DC-TC, without keypad an LCD display • 12 digital inputs (2 inputs also usable as analog inputs) • 8 transistor outputs • LCD display • Operating buttons • Screw terminals • Time switch • 12 digital inputs (2 inputs also usable as analog inputs) • 8 transistor outputs • LCD display • Operating buttons • Screw terminals • Time switch • Expandable with EASY.....E Features as per EASY621-DC-TC, without keypad an LCD display ALT OK 115/230 V AC 115/230 V AC, Retentive • 8 digital inputs, 115/230 V AC • 4 relay outputs • LCD display • Operating buttons • Screw terminals Features as per EASY 412-AC-R plus built-in time switch Features as per EASY412-AC-RC, without keypad an LCD display • 12 digital inputs, 115/230 V AC • 6 relay outputs • LCD display • Operating buttons • Screw terminals • Time switch • 12 digital inputs, 115/230 V AC • 6 relay outputs • LCD display • Operating buttons • Screw terminals • Time switch • Expandable with EASY.....E Features as per EASY619-AC-RC, without keypad an LCD display EASY412-DC-R 202403 1 off EASY412-DC-RC 202404 EASY412-DC-RCX 221596 EASY412-DC-TC 207808 EASY412-DC-TCX 212307 EASY620-DC-TC 212309 EASY621-DC-TC 218719 EASY621-DC-TCX 212311 EASY412-AC-R 202405 1 off EASY412-AC-RC 202406 EASY412-AC-RCX 212308 EASY618-AC-RC 212310 EASY619-AC-RC 218721 EASY619-AC-RCX 212312 Expansion units 24 V DC 115/230 V AC Coupling unit • 12 digital inputs • 8 transistor outputs • With connector • 12 digital inputs, 115/230 V AC • 6 relay outputs • With connector • Coupling unit for connecting to an EASY619/621 basic unit • Terminals for remote expansion up to 30 m to the expansion unit • With connector EASY620-DC-TE 212313 EASY618-AC-RE 212314 EASY200-EASY 212315 1 off easy Control Relay Description 6 Moeller NK2528-1024GB easy Control Relay Networking, Accessories, Documentation easy Control Relay Description Type Article No. Price See Price List Std. pack Networking AS-Interface PROFIBUS-DP • Linked directly to EASY619/621 • AS-Interface connection • Slave • 4 inputs, 4 outputs, 4 parameter bits • Addressable, 0 to 31 • Linked directly to EASY619/621 • PROFIBUS-DP slave EASY205-ASI 221598 1 off EASY204-DP 212316 1 off CD, menu in 6 languages Installation WIN 95, 98, WIN NT 8K memory card for storing the entire easy circuit diagram for EASY412 16K memory card for storing the entire easy circuit diagram for EASY6.. 2 m, for connecting to 9-pin serial interface on a PC with interface electronics circuit Simulator with power supply unit, 115/230 V AC / output 24 V DC, suitable for EASY412-DC... EASY-SOFT 202407 EASY-M-8K 202408 EASY-M-16 212317 EASY-PC-CAB 202409 EASY412-DC-SIM 212318 1 off For screw fixing on mounting plate, 3 fixing feet per EASY412, 3 fixing feet per EASY6.., 2 fixing feet per EASY200-EASY Primary-switched mode, stabilised 2, suitable for parallel connection to increase power output or for redundant operation at rated power ZB4-101-GF1 061360 9 off EASY400-POW 212319 1 off AWB2528-1304-D 205375 AWB2528-1304-GB 205481 AWB2528-1304-F 205482 AWB2528-1304-I 205483 AWB2528-1304-E 205484 1 off AWB2528-1316-D 205376 AWB2528-1316-GB 205485 AWB2528-1316-F 205486 AWB2528-1316-I 205487 AWB2528-1316-E 205488 1 off Accessories Software Memory card Connection cable Input/output simulator Fixing feet Switched-mode power supply unit • Rated input voltage 50/60 HZ: 115/230 V AC • Rated output voltage (residual ripple): 24 V DC (g 3%) • Rated output current: 1.25 A Documentation Manual for easy control relay German English French Italian Spanish Training guide for easy control relay German English French Italian Spanish 7 Moeller NK2528-1024GB RMQ Titan Range Selection Contacts M = make contact, B = break contact, f = Safety function by means of positive opening to IEC/EN 60 947-5-1 Colour Plunger Type Article No. Price See Price List Std. pack Complete units for surface mounting to IP 66 Emergency-stop actuator, tamper-proof to ISO 13 850/EN 418 Pull to release Max. configuration: 3x M22-(C)K... 1M M22-PV-KC11/I 216525 2 off M22-PVS/KC11/IY 216523 2 off M22-WRS/KC11/I 216526 2 off – M22-D-R-X0/K01 216510 5 off – M22-D-G-X1/K10 216512 5 off – M22-WRK/K10 216518 5 off M22-PV/K01 216515 5 off M22-IVS 216400 1 off 1B 14 13 22 21 Key-release mushroom buttons With 1 key MS 1 lock mechanism – 1M 1Bf 14 13 22 21 14 13 22 21 Key-operated buttons With two keys, Two positions, stay-put MS 1 lock mechanism – Push-button Flush 1M 1Bf – 1Bf 1M – 21 22 13 14 Selector switch, thumb-grip black Stay-put/spring-return function can be changed using M22-XC-. coding adapters Two positions, stay-put – 1M – 13 0 14 Complete units for front mounting, IP 66 Emergency-stop actuator, tamper-proof to ISO 13 850/EN 418 Yellow base Pull to release – – 1Bf 21 22 IVS top-hat rail adapter Front fixing Notes Other products are available in the Moeller catalogue supplement, NK 1160-1033 GB easy Control Relay Button plate 8 Moeller NK2528-1024GB easy Control Relay Technical Data easy Control Relay EASY200-EASY General Standards and regulations Dimensions W H D [mm] Weight Mounting Ambient temperature Operating ambient temperature Horizontal/vertical mounting Mechanical environmental conditions Pollution degree Degree of protection (EN 50 178, IEC 60 529, VBG4) Oscillations (IEC 60 068-2-6) Shock (IEC 60 068-2-27) Dropping (IEC 60 068-2-31) Free fall, in packaging (IEC 60 068-2-32) Electromagnetic compatibility (EMC) Electrostatic discharge (IEC/EN 61 000-4-2, Level 3) Electromagnetic fields (IEC/EN 61 000-4-3) Emitted interference, interference immunity Burst (Level 3) Power cables (IEC/EN 61 000-4-4) Signal lines High-energy pulses (surge) easy-AC (IEC/EN 61 000-4-5) High-energy pulses (surge) easy-DC (IEC/EN 61 000-4-5, Level 2) Dielectric strength Measurement of the air clearance and creepage distance Dielectric strength Tools and cable cross-sections Single-core Flexible with ferrule Slot-head screwdriver, width Tightening torque Backup/accuracy of real-time clock (only with easy-C) Clock battery back-up at 25 °C at 40 °C Accuracy of the real-time clock Retentive memory Write cycles of the retentive memory EASY6..-... EN 55 011, EN 55 022, IEC/EN 61 000-4, IEC 60 068-2-6, IEC 60 068-2-27 35.5 90 53 71.5 90 53 107.5 90 53 (2 space units) (4 space units) (6 space units) 70 g 200 g 300 g Top-hat rail, DIN 50 022, 35 mm or screw fixing with ZB 4-101-GF1 fixing feet (accessories) –25 to +55 °C Cold to IEC 60 068-2-1 Heat to IEC 60 68-2-2 Prevent condensation with suitable measures 0 to +55 °C –40 to +70 °C 5 to 95%, non-condensing (IEC 60 068-2-30) 795 to 1080 hPa SO2 10 cm³/m³, 4 days (IEC 60 068-2-42) H2S 1 cm³/m³, 4 days (IEC 60 068-2-43) Condensation LCD display (clearly visible) Storage/transport temperature Relative humidit Air pressure (operation) Corrosion resistance Repetition accuracy of timing relays Accuracy of timing relays Resolution EASY412-... Range “s” Range “M:S” Range “H:M” 2 2 IP 20 IP 20 10 to 57 Hz (constant amplitude 0.15 mm) 57 to 150 Hz (constant acceleration 2 g) 18 shocks (semi-sinusoidal 15 g/11 ms) Drop height 50 mm 1m 8 kV air discharge 6 kV contact discharge Field strength 10 V/m EN 55 011 Class B, EN 55 022 Class B 2 kV 2 kV 2 kV power cables symmetrical 0.5 kV power cables symmetrical EN 50 178, UL 508, CSA C22.2, No 142 EN 50 178 min. 0.2 mm², AWG 24 max. 4 mm², AWG 12 min. 0.2 mm², AWG 24 max. 2.5 mm², AWG 13 3.5 0.8 mm 0.5 – 0.7 Nm – – – Normally 64 h Normally 24 h Normally g 5 s/day, ~ g 0.5 h/year – – – g 1 % of value 10 ms 1s 1 min. – f 100 000 2 IP 20 9 Moeller NK2528-1024GB Power supply Rated voltage (sinusoidal) Permissible range Frequency, rated value, tolerance Input current consumption at 115/120 V AC 60 Hz at 230/240 V AC 50 Hz Voltage dips (IEC/EN 61 131-2) Heat dissipation at 115/120 V AC at 230/240 V AC Power supply Rated voltage Rated value Permissible range Residual ripple Input current at 24 V DC Voltage dips (IEC/EN 61 131-2) Power dissipation at 24 V DC Digital inputs 115/230 V AC Number Status display Electrical isolation To power supply Between each other To the outputs Rated voltage L (sinusoidal) 0 signal 1 signal Rated frequency Input current on 1 signal R1 to R12, I1 to I6 (EASY 618/619 also I9 to I12) Input current on 1 signal I7, I8 Delay time for 0 to 1 and 1 to 0 Debounce ON (I1 to I6/I12) Debounce OFF (I1 to I6/I9 to I12) Delay time I7, I8 for 1 to 0 Debounce ON Debounce OFF Delay time I7, I8 for 0 to 1 Debounce ON Debounce OFF Max. permissible cable length (per input) R1 to R12, I1 to I6 (with EASY 618/619 also I9 to I12) I7, I8 EASY412-AC-... EASY618/619-AC-RC(X) EASY618-AC-RC 115/120/230/240 V AC +10/–15 % 90 to 264 V AC 50/60 Hz, g 5 % 100/110/115/120/230/240 V AC +10/–15 85 to 264 V AC 50/60 Hz, g 5 % Normally 40 mA Normally 20 mA 20ms Normally 70 m Normally 35 m 20ms Normally 5 VA Normally 5 VA Normally 10 VA Normally 10 VA EASY412-DC-... EASY620/621-DC-TC(X) EASY620-DC-TE 24 V DC, –15 %, +20 % 20.4 to 28.8 V DC F5% Normally 80 mA 10ms Normally 2 W 24 V DC, –15 %, +20 % 20.4 to 28.8 V DC F5% Normally 140 m 10ms Normally 5 W EASY412-AC-... EASY618/619-AC-RC(X) EASY618-AC-RE 8 LCD display (if provided) 12 LCD display (if provided) No No Yes No No Yes 0 to 40 V AC 79 to 264 V AC 50/60 Hz 6 x 0.5 mA at 230 V AC 50 Hz 6 x 0.25 mA at 115 V AC 60 Hz 0 to 40 V AC 79 to 264 V AC 50/60 Hz 10 (12) x 0.5 mA at 230 V AC 50 Hz 10 (12) x 0.25 mA at 115 V AC 60 Hz 2 x 6 mA at 230 V AC 50 Hz 2 x 4 mA at 115 V AC 60 Hz 2 x 6 mA at 230 V AC 50 Hz 2 x 4 mA at 115 V AC 60 Hz 80 ms (50 Hz), 66n ms (60 Hz) 20 ms (50 Hz), 16n ms (60 Hz) 80 ms (50 Hz), 66n ms (60 Hz) 20 ms (50 Hz), 16n ms (60 Hz) 160 ms (50 Hz), 150 ms (60 Hz) 100 ms (50 Hz/60 Hz) 80 ms (50 Hz), 66n ms (60 Hz) 20 ms (50 Hz), 16n ms (60 Hz) 80 ms (50 Hz), 66n ms (60 Hz) 20 ms (50 Hz), 16n ms (60 Hz) 80 ms (50 Hz), 66n ms (60 Hz) 20 ms (50 Hz), 16n ms (60 Hz) Normally 40 m Normally 40 m Normally 100 m Normally 100 m easy Control Relay easy Control Relay Technical Data 10 Moeller NK2528-1024GB easy Control Relay easy Control Relay Technical Data Digital inputs 24 V AC Number Status display Electrical isolation To power supply Between each other To the outputs 24 V DC power supply Rated value 0 signal 1 signal Input current on 1 signal R1 to R12, I1 to I6 (EASY 620/621 also I9 to I12) Input current on 1 signal I7, I8 Delay time for 0 to 1 Debounce ON Debounce OFF Delay time for 1 to 0 Debounce ON Debounce OFF Cable length (unshielded) Analog inputs Number Electrical isolation To power supply To the digital inputs To the outputs Input type Signal range Resolution analog Resolution digital EASY412-DC-... EASY620/621-DC-TC(X) EASY620-TC-TE 8, 2 of which (I7,I8) can be used as analog inputs LCD display (if provided) 12, 2 of which (I7,I8) can be used as analog inputs, with basic unit LCD display (if provided) No No Yes No No Yes 24 V DC < 5.0 V DC I1 to I8 > 15.0 V DC I1 to I6 3.3 mA at 24 V DC 24 V DC < 5.0 V DC I1 to I12, R1 to R12 > 15.0 V DC I1 to I6, I9 to I12, R1 to R12 3.3 mA at 24 V DC 2.2 mA at 24 V DC 2.2 mA at 24 V DC 20 ms Normally 0.25 ms (I1 to I6) 20 ms Normally 0.25 ms (I1 to I6, I9 to I12) 20 ms Normally 0.4 ms, I1 to I6 Normally 0.2 ms I7, I8 100 m 20 ms Normally 0.4 ms I1 to I6, I9 to I12 Normally 0.2 ms I7, I8 100 m EASY412-DC... EASY620/621-DC-TC(X) 2 2 No No Yes DC voltage 0 to 10 V DC 0.1 V 0.1 No No Yes DC voltage 0 to 10 V DC 0.1 V 0.1 U[V] 9.9 5.0 0 Input impedance Accuracy of Two easy devices Within a single device Conversion time, analog/digital Input current Cable length (shielded) 5.0 11.2 kO g 3 % of actual value g 2 % of actual value (I7, I8), g 0.12 V Debounce ON: 20 ms Debounce OFF: every cycle < 1 mA 30 m 9.9 11.2 kO 11 Moeller NK2528-1024GB Relay outputs Number Type of outputs In groups of Parallel connection of outputs to increase current rating Circuit-breaker B 16 or fuse 8 AT Potential isolation to mains supply, inputs Mechanical lifespan (operations) Contacts relays Conventional free air thermal current Recommended for load Short-circuit resistance cos 1 Short-circuit resistance cos 0.5 to 0.7 Rated impulse withstand voltage Uimp contact coil Rated insulation voltage Ui Rated operational voltage Ue Safe isolation to EN 50 178 between coil and contact Safe isolation to EN 50 178 between two contacts Making capacity AC-15 250 V AC, 3 A (600 Ops/h) DC-13 L/R F150 ms 24 V DC, 1 A (500 Ops/h) Breaking capacity AC-15 250 V AC, 3 A (600 Ops/h) DC-13 L/R F150 ms 24 V DC, 1 A (500 Ops/h) Filament lamp load 1000 W at 230/240 V AC 500 W at 115/120 V AC Fluorescent tube 10 x 58 W at 230/240 V AC With ballast Uncompensated 1 x 58 W at 230/240 V AC Conventional, compensated Operating frequency, relays Device lifetime Mechanical switching frequency Resistive lamp load Inductive load EASY412-...-R... EASY618/619-R... 4 Relay 1 Not permissible 6 Miniature circuit-breaker B16 or 8 A fuse (slow) Yes 300 Veff AC (safe isolation) 600 Veff AC (Basic isolation) 10 x 106 8 A (10 A UL) > 500 mA, 12 V AC/DC 16 A characteristic B (B16) at 600 A 16 A characteristic B (B16) at 900 A 6 kV 250 V AC 250 V AC 250 V AC 250 Veff 300 000 switching operations 200 000 switching operations 300 000 switching operations 200 000 switching operations 25 000 switching operations 25 000 switching operations 25 000 switching operations 25 000 switching operations 25 000 switching operations 10 million (107) 10 Hz 2 Hz 0.5 Hz EASY400-POW Input voltage Range Mains frequency Range Output voltage (tolerance) Output current Overcurrent limit Not adversely affected by no-load operation and protected against short-circuit Terminals Single-core Flexible with ferrule Emitted interference, interference immunity Potential isolation, primary/secondary Protection class Ambient temperature Storage temperature 115, 230 V AC 85 to 264 V AC 50/60 Hz 47 to 63 Hz 24 V DC (g 3%) 1.25 A From 1.4 A Yes 0.2 to 4 mm², AWG 24 to 12 0.2 to 2.5 mm², AWG 24 to 13 EN 50 081-1 Class B; 50 082-2 Yes, SELV (VDE 0100 T410; IEC 364-4-41) IP20 –25 to +55°C –40 to +70 °C easy Control Relay easy Control Relay Technical Data 12 Moeller NK2528-1024GB easy Control Relay easy Control Relay Technical Data Transistor outputs Number Contacts Rated voltage Ue Permissible range Residual ripple Supply current 0 signal 1 signal Reverse polarity protection Potential isolation to inputs, power supply Rated current Ie for 1 signal Lamp load Residual current with 0 signal per channel Max. output voltage with 0 signal with external load < 10 MO with 1 signal, Ie = 0.5 A Short-circuit protection Short-circuit tripping current for Ra F 10 mO Max. total short-circuit current Peak short-circuit current Thermal cutout Maximum operating frequency at constant resistive load RL < 100 kO : operations per hour Parallel connection of outputs with resistive load; inductive load with external suppression circuit, combination within a group EASY412-DC-T... EASY620/621-DC-T... 4 Semiconductors 24 V DC 20.4 to 28.8 V DC F5 % 8 Semiconductors 24 V DC 20.4 to 28.8 V DC F5 % Normally 9 mA, max. 16 mA Normally 12 mA, max. 22 mA Yes Yes Normally 18 mA, max. 32 mA Normally 24 mA, max. 44 mA max. 0.5 A DC 5 watts without RV < 1.0 mA 2.5 V U = Ue–1 V Yes, (detected via diagnostics input I16, I15; R15; R16) 0.7 A F Ie F 2 A 8A 16 A 16 A 32 A Yes Yes 40 000 (depends on circuit diagram and load) Group 1: Q1 to Q4 Group 1: Q1 to Q4, S1 to S4 Group 2: Q5 to Q8, S5 to S8 Number of outputs Total maximum current Status display of the outputs max. 4 2.0 A LCD display (if provided) max. 4 Approvals currently UL/CSA approved; others in preparation: EASY412-DC-R EASY412-DC-RC EASY412-DC-TC EASY412-DC-TCX EASY412-AC-R EASY412-AC-RC EASY412-AC-RX EASY620-DC-TC EASY618-AC-RC Notes For more detailed technical specifications refer to technical data in AWB 2528-1304-GB LCD display (if provided) 13 Moeller NK2528-1024GB easy Control Relay Dimensions Control Relay EASY200-EASY EASY4... 10.75 50 easy Control Relay 7.5 45 110 90 102 M4 4.5 M4 7.5 47.5 35.75 56.5 35.5 71.5 58 EASY618-... EASY619-... EASY620-... EASY621-... 75 16.25 45 110 90 M4 102 16.25 4.5 107.5 47.5 56.5 58