AXTAL AXHV0003

Issue: 01
Specification
AXHV0003
Oscillator type :
VCO – Voltage Controlled Oscillator
Parameter
min.
typ.
max.
Unit
Date: 2005-12-08
Condition
250
330
MHz
@ 25°C
Frequency tuning range
Frequency adjustment range
EFC voltage VC
0.5
5
V
positive
EFC slope (∆f / ∆VC)
RF output
Signal waveform
SINUS
Amplitude
-2
+1
dBm
RL = 50 Ω
Harmonics
first
-18
dBc
second
-10
dBc
-112
dBc/Hz @ 100 kHz
Phase Noise
Supply voltage VS
4.75
5
5.25
V
Current consumption (steady state)
6
mA
-40
+85
°C
Operating temperature range
-45
+90
°C
Operable temperature range
-55
+95
°C
Storage temperature range
12.7 x 12.7 x 6.1
mm
Enclosure (see drawing) LxWxH
5
gram
Weight
bulk
IEC 60286-3
Packing
1500
V
HBM, IEC 61000-4-2
ESD Sensitivity
Notes:
1. Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated
Ordering Code:
Model (Specification)
AXHV0003
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
Frequency Range [MHz]
250-330
AXHV0003
page 1(3)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Pin connections
Footprint:
Pin # Symbol
P1
VC
P2 RF OUT
P3
VS
P4
N.C.
All
GND
others
Function
Control Voltage (EFC)
RF Output
Supply Voltage
Not Connected
Ground
Typical Performance
HV0003
5V/5.5mA
f/MHz
340
320
300
280
S=25MHz/V
260
240
0
1
2
3
4
5
Vtune/V
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
AXHV0003
page 2(3)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
HV0003
P/dBm
4
2
0
-2
-4
0
1
2
3
4
5
Vtune/V
Environmental conditions
Test
IEC 60068
Part ...
Visual inspection,
dimensions
Sealing tests
(if applicable)
Solderability
Resistance to
soldering heat
Shock*
IEC 60679-1
clause ...
4.3
2-17
4.6.2
2-20
2-58
4.6.3
2-27
4.6.8
Bump*
2-29
4.6.6
Free fall*
2-32
4.6.9
Test conditions
Enclosure styles as in IEC 60679-3
or 61837, if applicable
Gross leak: Test Qc,
Fine leak: Test Qk
Test Ta (235 ± 5)°C Method 1
Test Tb Method 1A, 5s
Vibration, sinusoidal* 2-6
4.6.7
Rapid change of
temperature
Dry heat
2-14
4.6.5
2-2
4.6.14
Damp heat, cyclic*
2-30
4.6.15
Cold
2-1
4.6.16
Climatic sequence*
1-7
4.6.17
Damp heat, steady
state*
Endurance tests
- ageing
- extended aging
2-3
4.6.18
Test Ea, 3 x per axes 100g, 6 ms
half-sine pulse
Test Eb, 4000 bumps per Axes, 40g,
6 ms
Test Ed procedure 1,
2 drops from 1m height
Test Fc, 30 min per axes,
10 Hz - 55 Hz 0,75mm; 55 Hz - 2
kHz, 10g
Test Na, 10 cycles at extremes of
operating temperature range
Test Ba, 16 h at upper temperature
indicated by climatic category
Test Db variant 1 severity b),
55°C/95% r.H., 6 cycles
Test Aa, 2 h at lower temperature
indicated by climatic category
Sequence of 4.6.14, 4.6.15 (1st
cycle), 4.6.16, 4.6.15 (5 cycles)
Test Ca, 56 days
4.7.1
4.7.2
30 days @ 85°C, OCXO @25°C
1000h, 2000h, 8000h @85°C
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
AXHV0003
page 3(3)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]