AXTAL AXIOM20-17

Issue: 01
Specification
AXIOM20-17
Oscillator type :
OCXO for Cospas-Sarsat Beacons
Parameter
min.
Frequency range
Nominal frequency
Frequency stability
Initial tolerance
vs. temperature
- temperature ramp of ± 5 °C / h
- thermal shock of 30°C
operating temperature range
vs. supply voltage variation
vs. load change
Overall aging 5 years
Frequency adjustment range
Electronic Frequency Control (EFC)
RF output
Signal waveform
Load
Rise & decay time
Symmetry
Warm-up time
Supply voltage VS1 (Oven)
Current consumption (steady state)
Current consumption during warm-up
Supply voltage VS2 (Oscillator)
Current consumption (VS2)
Operable temperature range
Storage temperature range
Enclosure (see drawing)
Weight
Packing
ESD Sensitivity
typ.
max.
Unit
±2
MHz
MHz
ppm
ppm
±2
±2
+55
+55
± 20
± 20
± 10
ppb/min
ppb
°C
°C
ppb
ppb
ppm
60.750
±1
-40
-20
Date: 2007-10-17
Condition
Note 3
Clause 4.2.2
Clause 4.2.3
Class 1 (Option I)
Class 2 (Option I)
VS ± 5%
N.A.
HCMOS
15
7
40
60
2
4.75
5.0
5.25
100
300
400
250
300
4.75
5.0
5.25
10
15
-45
+60
-45
+105
20.7x13.1x8.5 max.
5
Palette or stick
1500
pF
ns
%
min
V
mA
mA
mA
V
mA
°C
°C
mm
gram
V
∆ffinal/f0 < ±0.1 ppm
Note 2
@ +25°C
Class 1
Class 2
Note 2
IEC 60679-3 CO 02
HBM as in IEC 610004-2
Notes:
1. Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated
2. Oven supply VS1 can be switched on and off separately, while oscillator supply VS2 is on.
Oven will not work properly without VS1 applied !
3. In accordance with mentioned clauses of Cospas/Sarsat Specification C/S T.001
Ordering Code:
Model (Specification)
AXIOM20-17
Option I (Class) Frequency [MHz]
2
60.750
Example: AXIOM20-17-2-60.750 MHz
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
AXIOM20-17
page 1(2)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Enclosure drawing
Pin connections
Pin # Symbol
1
VS1
7
GND
8
RF OUT
14
VS2
Function
Supply Voltage (Oven)
Ground
RF Output
Supply Voltage (Oscillator)
Environmental conditions
Test
IEC 60068
Part ...
Visual inspection,
dimensions
Sealing tests
(if applicable)
Solderability
Resistance to
soldering heat
Shock*
IEC 60679-1
clause ...
4.3
Test conditions
Enclosure styles as in IEC
60679-3 or 61837, if applicable
Gross leak: Test Qc,
Fine leak: Test Qk
Test Ta (235 ± 5)°C Method 1
Test Tb Method 1A, 5s
2-17
4.6.2
2-20
2-58
4.6.3
2-27
4.6.8
Bump*
2-29
4.6.6
Free fall*
2-32
4.6.9
Vibration,
sinusoidal*
2-6
4.6.7
Rapid change of
temperature
Dry heat
2-14
4.6.5
2-2
4.6.14
Damp heat, cyclic*
2-30
4.6.15
Cold
2-1
4.6.16
Climatic sequence*
1-7
4.6.17
Damp heat, steady
state*
Endurance tests
- ageing
- extended aging
2-3
4.6.18
Test Ea, 3 x per axes 100g, 6 ms
half-sine pulse
Test Eb, 4000 bumps per Axes,
40g, 6 ms
Test Ed procedure 1,
2 drops from 1m height
Test Fc, 30 min per axes,
10 Hz - 55 Hz 0,75mm; 55 Hz - 2
kHz, 10g
Test Na, 10 cycles at extremes
of operating temperature range
Test Ba, 16 h at upper
temperature indicated by climatic
category
Test Db variant 1 severity b),
55°C/95% r.H., 6 cycles
Test Aa, 2 h at lower
temperature indicated by climatic
category
st
Sequence of 4.6.14, 4.6.15 (1
cycle), 4.6.16, 4.6.15 (5 cycles)
Test Ca, 56 days
4.7.1
4.7.2
30 days @ 85°C, OCXO @25°C
1000h, 2000h, 8000h @85°C
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
AXIOM20-17
page 2(2)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]