Contactors & Control Relays Safety Contactors 104S-C Product Selection Reversing AC-Operated Contactors • AC Operating Mechanism, 3 Main Contacts • Includes Mechanical/Electrical Interlock • Includes Reversing Power Wiring Ratings for Switching AC Motors Ie Auxiliary Contacts Installed per Contactor AC-2, AC-3, AC-4 [A] kW (50 Hz) HP (60 Hz) 1∅ 3∅ AC-3 AC-1 230V 400V 415V 9 32 3 4 4 4 1/2 1 1/2 2 2 5 7-1/2 12 32 4 5.5 5.5 5.5 1/2 2 3 3 7-1/2 10 16 32 5.5 7.5 7.5 7.5 1 3 5 5 10 15 23 32 7.5 11 13 10 2 3 5 7-1/2 15 15 30 65 10 15 15 15 2 5 7-1/2 10 20 25 37 43 65 85 11 18.5/20 13 22 500V 690V 115V 230V 200V 230V 460V 575V 20 25 18.5 3 22 5 3 10 7.5 10 10 25 15 30 30 30 60 100 18.5 32 37 32 5 10 15 20 40 50 72 100 22 40 45 40 5 15 20 25 50 60 85 100 25 45 55 45 7-1/2 15 25 30 60 60 NO NC" Catalogue Number ! 0 6 104S-C09⊗012C 1 5 104S-C09⊗210C 0 6 104S-C12⊗012C 1 5 104S-C12⊗210C 0 6 104S-C16⊗012C 1 5 104S-C16⊗210C 0 6 104S-C23⊗012C 1 5 104S-C23⊗210C 0 5 104S-C30⊗010C 1 5 104S-C30⊗210C 0 5 104S-C37⊗010C 1 5 104S-C37⊗210C 0 5 104S-C43⊗010C 1 5 104S-C43⊗210C 0 5 104S-C60⊗010C 1 5 104S-C60⊗210C 0 5 104S-C72⊗010C 1 5 104S-C72⊗210C 0 5 104S-C85⊗010C 1 5 104S-C85⊗210C ! For other contact configurations, please contact your local Rockwell Automation/Allen-Bradley distributor. " One of the N.C. auxiliary contacts is supplied as part of the mechanical/electrical interlock. ⊗ Coil Voltage Code The Catalogue Number as listed is incomplete. Select a coil voltage code from the table below to complete the Catalogue Number. Example: 120V 60 Hz: Catalogue Number 104S-C09⊗210C becomes Catalogue Number 104S-C09D210C. Standard Coil Voltage 100110 110 KP – D – KP – KY KP – KD 277 347 380 380400 T – – – – A T I – KA – – 12 24 32 36 42 48 100 50 Hz R K V W 60 Hz Q J – V X Y – X 50/60 Hz – KJ – – – Standard Coil Voltage 220230 230 230240 240 50 Hz F – VA 60 Hz – – 50/60 Hz KL KF 120 200220 208 208240 127 200 P S KG L – – D – – KG H L – – KG KL – – 400 400415 440 480 500 550 600 N – G B – M C – E – – – N B – – C – – KN – KB – – – – 9-7 Contactors & Control Relays Safety Contactors 104S-C Product Selection Reversing DC-Operated Contactors • DC Operating Mechanism, 3 Main Contacts, Line Side Coil Terminations • Includes Mechanical/Electrical Interlock • Includes Reversing Power Wiring Ratings for Switching AC Motors Ie [A] AC-3 9 Auxiliary Contacts Installed per Contactor AC-2, AC-3, AC-4 kW (50 Hz) AC-1 32 230V 3 400V 415V 4 HP (60 Hz) 1∅ 500V 4 690V 4 115V 1/2 3∅ 230V 200V 1 1/2 2 230V 2 460V 5 575V 7-1/2 12 32 4 5.5 5.5 5.5 1/2 2 3 3 7-1/2 10 16 32 5.5 7.5 7.5 7.5 1 3 5 5 10 15 23 32 7.5 11 13 10 2 3 5 7-1/2 15 15 30 65 10 15 15 15 2 5 7-1/2 10 20 25 37 65 11 18.5/ 20 20 18.5 3 5 10 10 25 30 43 85 13 22 25 22 3 7.5 10 15 30 30 60 100 18.5 32 37 32 5 10 15 20 40 50 72 100 22 40 45 40 5 15 20 25 50 60 85 100 25 45 55 45 7-1/2 15 25 30 60 60 NO NC" Catalogue Number! 0 6 104S-C09⊗012C 1 5 104S-C09⊗210C 0 6 104S-C12⊗012C 1 5 104S-C12⊗210C 0 6 104S-C16⊗012C 1 5 104S-C16⊗210C 0 6 104S-C23⊗012C 1 5 104S-C23⊗210C 0 5 104S-C30⊗010C 1 5 104S-C30⊗210C 0 5 104S-C37⊗010C 1 5 104S-C37⊗210C 0 5 104S-C43⊗010C 1 5 104S-C43⊗210C 0 5 104S-C60⊗010C 1 5 104S-C60⊗210C 0 5 104S-C72⊗010C 1 5 104S-C72⊗210C 0 5 104S-C85⊗010C 1 5 104S-C85⊗210C ! For other contact configurations, please contact your local Rockwell Automation/Allen-Bradley distributor. " One of the N.C. auxiliary contacts is supplied as part of the mechanical/electrical interlock. ⊗ Coil Voltage Suffix Code The Catalogue Number as listed is incomplete. Select a coil voltage code from the table below to complete the Catalogue Number. Example: 120V 60 Hz: Catalogue Number 104S-C09⊗210C becomes Catalogue Number 104S-C09ZJ210C. DC Voltage 104S-C09…C43 104S-C60…C85 104S-C09…C43 104S-C60…C85 9-8 9 12 24 36 48 60 64 72 Standard ZR with Integrated Diode — ZQ ZJ ZW ZY ZZ ZB ZG — DJ — — — — with Integrated Diode DR — DQ DJ DW DY DZ DB DG DC Voltage 80 110 115 125 220 230 250 Standard ZE ZD ZP ZS ZA ZF ZT with Integrated Diode — — — — — — — with Integrated Diode DE DD DP DS DA DF DT