Switching Spark Gap FS06X-1NG Ordering code: B88069X3660T502 Nominal breakdown voltage VN 600 V Initial values 2) Static breakdown voltage VS 1) First ignition value VS, FTE after 24 hours in darkness Following ignition values VS, FIV ≤ 720 560 ... 680 V V Electrical life time 3) Breakdown voltage VB First ignition value VB, FTE after 24 hours in darkness Ignition time tI at V0 during life Following ignition values VB, FIV ≤ 750 ≤ 90 540 ... 700 V ms V Switching operations at – 40; +25; +125°C 40 000 Ignitions Test circuit parameters Open circuit voltage V0 Loading resistance R Discharge capacitance C Inductance L Discharge peak current IP 750 13 470 0.1 max. 1000 V kΩ nF µH A > 10 ≤2 ≤ 50 200 ~2 MΩ % ns Hz g General technical data Insulation resistance at 100 V Early ignition values between 500 and 680 V Breakdown time Maximum switching frequency Weight Marking, blue 600 WWY O 600 WW Y O 1) 2) 3) - Nominal voltage - Calendar week of production - Year of production - Non radioactive At delivery AQL 0,65 level II, DIN ISO 2859 Page 2, Fig. 1 and 2 Page 2, Fig. 3 and 4 KB AB E / KB AB PM Issue 06, 16.06.2004 Page 1 of 2 Switching Spark Gap FS06X-1NG Ordering code: B88069X3660T502 Fig. 1: QC- test circuit (100% outgoing inspection) Fig. 2: Explanation of measurands I = const 51kΩ VS, FTE VS, FIV VS DUT 0,22µF VN VS t ICU - VN DUT device under test ICU ignition control unit (sensitivity 10 .. 30 µA) Discharge current 10 – 20 mA Fig. 3: QC- test circuit (sampling inspection at 25 °C) dVS/dt ~ dVN/dt Fig. 4: Explanation of measurands VB, FTE L R VB, FTE Range of VB, FIV VB Early ignition VN VO C DUT VB t tI 1s 10 s Not to scale Dimensions in mm Non controlled document EPCOS AG 2002. Reproduction, publication and dissemination of this data sheet, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. Purchase orders are subject to the General Conditions for the Supply of Products and Services of the Electrical and Electronics Industry recommended by the ZVEI (German Electrical and Electronic Manufacturers' Association), unless otherwise agreed. KB AB E / KB AB PM Issue 06, 16.06.2004 Page 2 of 2