Issue Date: 2010-05-17 Page 1 of 22 Report Reference # E193009-A21-UL 2013-02-21 UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: Rating: Applicant Name and Address: UL 60950-1, 2nd Edition, 2011-12-19 (Information Technology Equipment - Safety - Part 1: General Requirements) CSA C22.2 No. 60950-1-07, 2nd Edition, 2011-12 (Information Technology Equipment - Safety - Part 1: General Requirements) Component Recognition QQGQ2, QQGQ8 (Power Supplies for Information Technology Equipment Including Electrical Business Equipment) DC/DC Converter HAE50-xxSzzWz1z1z1z1z1z1z1z1z1z1, HAE75xxSzzWz1z1z1z1z1z1z1z1z1z1, HAE50yySzzz1z1z1z1z1z1z1z1z1z1, HAE75-yySzzz1z1z1z1z1z1z1z1z1z1 or HAE100-yySzzz1z1z1z1z1z1z1z1z1z1 (xx can be 24 and 48, yy can be 12, 24 and 48, zz can be 3P3, 05, 12, 15, 24, 28 and 48, z1 can be any alphanumeric or blank) See Miscellaneous 7-01 for details. POWER MATE TECHNOLOGY CO LTD 36 22ND RD TAICHUNG INDUSTRIAL PARK TAICHUNG 408 TAIWAN Copyright © 2013 Issue Date: 2010-05-17 Page 2 of 22 Report Reference # E193009-A21-UL 2013-02-21 Engineering Conditions of Acceptability For use only in or with complete equipment where the acceptability of the combination is determined by UL LLC. When installed in an end-product, consideration must be given to the following: The following Production-Line tests are conducted for this product: Electric Strength The end-product Electric Strength Test is to be based upon a maximum working voltage of: TNV-2 voltage input - SELV output: 125 Vrms, 140 Vpk. The following secondary output circuits are SELV: Outputs of all models. The following secondary output circuits are at non-hazardous energy levels: Outputs of all models. The power supply terminals and/or connectors are: Suitable for factory wiring The investigated Pollution Degree is: 1 The following end-product enclosures are required: Electrical, Mechanical, Fire The maximum continuous power supply output (Watts) relied on forced air cooling from: External Fan, rated 3.337 cfm (located 5 cm from lateral side of unit) The component is considered as basic insulation and intended to be installed in isolated secondary circuit which is separated from primary circuit by Reinforce or Double insulation; additional tests of Humidity Test should be considered in the end product. The Heatsink and Fixture shown in Enclosure ID 3-06 to 3-09 shall be evaluated in end use product. The distances were investigated for transient rating for SECONDARY CIRCUIT is up to 800 V; any other consideration for transient rating greater than 800 V shall be evaluated in end use product.