Issue Date: 2013-01-22 Page 1 of 6 Report Reference # E193009-A26-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: Rating: Applicant Name and Address: UL 60950-1, 2nd Edition, 2011-12-19 (Information Technology Equipment - Safety - Part 1: General Requirements) CSA C22.2 No. 60950-1-07, 2nd Edition, 2011-12 (Information Technology Equipment - Safety - Part 1: General Requirements) Component Recognition QQGQ2, QQGQ8 (Power Supplies for Information Technology Equipment Including Electrical Business Equipment) DC to DC Converter PDL06-XYAz1z1z1z1z1z1 (where "X" can be 05, 12, 24 or 48; "Y" can be S or D; "A" can be 3P3, 05, 09, 12, 15 or 24; "z1" can be any alphanumeric or blank) (optional) See Enclosure Miscellaneous 7-01 for ratings details. POWER MATE TECHNOLOGY CO LTD 36 22ND RD TAICHUNG INDUSTRIAL PARK TAICHUNG 408 TAIWAN Copyright © 2013 Issue Date: 2013-01-22 Page 2 of 6 Report Reference # E193009-A26-UL Engineering Conditions of Acceptability For use only in or with complete equipment where the acceptability of the combination is determined by UL LLC. When installed in an end-product, consideration must be given to the following: The end-product Electric Strength Test is to be based upon a maximum working voltage of: To be evaluated in end product investigation The following secondary output circuits are at non-hazardous energy levels: All outputs of all models The power supply terminals and/or connectors are: Not investigated for field wiring The investigated Pollution Degree is: 2 Proper bonding to the end-product main protective earthing termination is: Not required An investigation of the protective bonding terminals has: Not been conducted The following end-product enclosures are required: Mechanical, Fire, Electrical The unit serves as Functional insulation only. The input voltage of model: PDL06-XYAz1z1z1z1z1z1 (where "X" can be 48; "Y" can be S or D; "A" can be 3P3, 05, 09, 12, 15 or 24; "z1" can be any alphanumeric or blank) exceed 60Vdc and the secondary output circuits should be evaluated as "Special Application - TNV-2" or "HAZARDOUS VOLTAGE" in end product. The insulation system is not controlled and evaluated. It shall be considered when insulation system would be required in end-product. Client announced maximum rating of slow-blow fuse for series model as below: 3A for PDL0605SXX modules; 1.6A for PDL06-12SXX modules; 1A for PDL06-24SXX modules; 0.5A for PDL0648SXX modules. The unit was not tested on fuse protection circuit. It shall be evaluated in end product investigation.