TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Products contained in this shipment may be subject to ITAR regulations. Warning: The export of these commodity(ies), technology, or software are subject either to the U.S. Commerce Department Export Administration Regulations (E.A.R.), or to the U.S. State Department International Traffic In Arms Regulations (I.T.A.R.). Diversion, the shipment to unauthorized locations or entities, or the disclosure of related technical data or software to unauthorized foreign nationals is contrary to U.S. law and is prohibited. If export is authorized to a specific country or end-users, compliance with the U.S. export laws is required prior to transfer, transshipment on a non-continuous voyage, or disposal in any other country, or to any other end-user of these commodities, either in their original form or after being incorporated into other end-items. An ISO 9001:2008 and DSCC Certified Company 1 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Radiation Lot Acceptance Testing (RLAT) of the RH1499MW Quad Rail-toRail Input and Output Precision C-Load Op Amp for Linear Technology Customer: Linear Technology, PO# 62433L RAD Job Number: 12-275 Part Type Tested: RH1499MW Quad Rail-to-Rail Input and Output Precision C-Load Op Amp. Traceability Information: Fab Lot Number: W10739896.2, Wafer Number: 20, Assembly Lot number: 626933.1, Date Code: 1120A. See photograph of unit under test in Appendix A. Quantity of Units: 12 units received, 5 units for biased irradiation, 5 units for unbiased irradiation and 2 units for control. Serial numbers 519, 520, 521, 522 and 524 were biased during irradiation, serial numbers 536, 537, 538, 539 and 542 were unbiased during irradiation and serial numbers 543 and 544 were used as control. See Appendix B for the radiation bias connection table. Radiation and Electrical Test Increments: 50-300rad(Si)/s ionizing radiation with electrical test increments: pre-irradiation, 20krad(Si), 50krad(Si), 100krad(Si) and 200krad(Si). Pre-Irradiation Burn-In: Burn-In performed by Linear Technology prior to receipt by RAD Overtest and Post-Irradiation Anneal: No overtest. No anneal. Radiation Test Standard: MIL-STD-750E TM1019 and/or MIL-STD-883H TM1019 Condition A. Test Hardware and Software: LTS2020 Automated Tester, Entity ID TS04, Calibration Date: 4/28/2011, Calibration Due: 4/28/2012. LTS2101 Family Board, Entity ID FB10. LTS0600 Test Fixture, Entity ID TF03. RH1499 BGSS-061114 DUT Board. Test Program: RH1499X.SRC Facility and Radiation Source: Aeroflex RAD's Longmire Laboratories, Colorado Springs, CO. Gamma rays provided by JLSA 81-24 Co60 source. Dosimetry performed by Air Ionization Chamber (AIC) traceable to NIST. Aeroflex RAD's dosimetry has been audited by DSCC and Aeroflex RAD has been awarded Laboratory Suitability for MIL-STD-750 and MIL-STD-883 TM 1019. Irradiation and Test Temperature: Room temperature controlled to 24°C±6°C per MIL-STD-883 and MIL-STD-750. RLAT Result: PASSED. The units-under-test passed the total ionizing dose test to the maximum tested dose level of 200krad(Si) with all parameters remaining within their datasheet specifications. An ISO 9001:2008 and DSCC Certified Company 2 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 1.0. Overview and Background It is well known that total dose ionizing radiation can cause parametric degradation and ultimately functional failure in electronic devices. The damage occurs via electron-hole pair production, transport and trapping in the dielectric and interface regions. In discrete devices the bulk of the damage is frequently manifested as a reduction in the gain and/or breakdown voltage of the device. The damage will usually anneal with time following the end of the radiation exposure. Due to this annealing, and to ensure a worst-case test condition MIL-STD-883 TM1019.8 calls out a dose rate of 50 to 300rad(Si)/s as Condition A and further specifies that the time from the end of an incremental radiation exposure and electrical testing shall be 1-hour or less and the total time from the end of one incremental irradiation to the beginning of the next incremental radiation step should be 2-hours or less. The work described in this report was performed to meet MIL-STD-883 TM1019.8 Condition A. 2.0. Radiation Test Apparatus The total ionizing dose testing described in this final report was performed using the facilities at Aeroflex RAD's Longmire Laboratories in Colorado Springs, CO. The high dose rate total ionizing dose (TID) source is a JLSA 81-24 irradiator modified to provide a panoramic exposure. The Co-60 rods are held in the base of the irradiator heavily shielded by lead. During the radiation exposures the rod is raised by an electronic timer/controller and the exposure is performed in air. The dose rate for this irradiator in this configuration ranges from <1rad(Si)/s to a maximum of approximately 120rad(Si)/s, determined by the distance from the source. For high-dose rate experiments the bias boards are placed in a radial fashion equidistant from the raised Co-60 rods with the distance adjusted to provide the required dose rate. The irradiator calibration is maintained by Aeroflex RAD Longmire Laboratories using air ionization chamber (AIC) equipment calibrated with traceability to the National Institute of Standards and Technology (NIST). Figure 2.1 shows a photograph of the JLSA 81-24 Co-60 irradiator at Aeroflex RAD's Longmire Laboratory facility. Aeroflex RAD is currently certified by the Defense Supply Center Columbus (DSCC) for Laboratory Suitability under MIL STD 750 and MIL-STD-883. Additional details regarding Aeroflex RAD dosimetry for TM1019 Condition A testing are available in Aeroflex RAD's report to DSCC entitled: "Dose Rate Mapping of the J.L. Shepherd and Associates Model 81 Irradiator Installed by Radiation Assured Devices". An ISO 9001:2008 and DSCC Certified Company 3 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Figure 2.1. Aeroflex RAD's high dose rate Co-60 irradiator. The dose rate is obtained by positioning the deviceunder-test at a fixed distance from the gamma cell. The dose rate for this irradiator varies from approximately 120rad(Si)/s close to the rods down to 1rad(Si)/s at a distance of approximately 2-feet. An ISO 9001:2008 and DSCC Certified Company 4 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 3.0. Radiation Test Conditions The RH1499MW Quad Rail-to-Rail Input and Output Precision C-Load Op Amp described in this final report were irradiated under two different bias conditions, one when biased with a split 15V supply, and one when unbiased with all pins tied to ground. See the TID Bias Table in Appendix B for the full bias circuits. In our opinion, this bias circuit satisfies the requirements of MIL-STD-883H TM1019.8 Section 3.9.3 Bias and Loading Conditions which states "The bias applied to the test devices shall be selected to produce the greatest radiation induced damage or the worst-case damage for the intended application, if known. While maximum voltage is often worst case some bipolar linear device parameters (e.g. input bias current or maximum output load current) exhibit more degradation with 0 V bias." The devices were irradiated to a maximum total ionizing dose level of 200krad(Si) with incremental readings at 20krad(Si), 50krad(Si) and 100krad(Si). Electrical testing occurred within one hour following the end of each irradiation segment. For intermediate irradiations, the parts were tested and returned to total dose exposure within two hours from the end of the previous radiation increment. The TID bias board was positioned in the Co-60 cell to provide the required minimum of 50rad(Si)/s and was located inside a lead-aluminum enclosure. The lead-aluminum enclosure is required under MILSTD-883H TM1019.8 Section 3.4 that reads as follows: "Lead/Aluminum (Pb/Al) container. Test specimens shall be enclosed in a Pb/Al container to minimize dose enhancement effects caused by lowenergy, scattered radiation. A minimum of 1.5 mm Pb, surrounding an inner shield of at least 0.7 mm Al, is required. This Pb/Al container produces an approximate charged particle equilibrium for Si and for TLDs such as CaF2. The radiation field intensity shall be measured inside the Pb/Al container (1) initially, (2) when the source is changed, or (3) when the orientation or configuration of the source, container, or test-fixture is changed. This measurement shall be performed by placing a dosimeter (e.g., a TLD) in the device-irradiation container at the approximate test-device position. If it can be demonstrated that low energy scattered radiation is small enough that it will not cause dosimetry errors due to dose enhancement, the Pb/Al container may be omitted." The final dose rate within the high dose rate lead-aluminum enclosure was determined using calibration calculations based on air ionization chamber (AIC) dosimetry performed just prior to beginning the total dose irradiations. The final dose rate for this work was 50.43rad(Si)/s with a precision of ±5%. An ISO 9001:2008 and DSCC Certified Company 5 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 4.0. Tested Parameters During the total ionizing dose characterization testing the following electrical parameters were measured pre- and post-irradiation: 1. +Supply Current (A) @ VS=+/-15V 2. -Supply Current (A) @ VS=+/-15V 3. Input Offset Voltage1 1 (V) @ VS=+/-15V, VCM=0V 4. Input Offset Voltage1 2 (V) @ VS=+/-15V, VCM=0V 5. Input Offset Voltage1 3 (V) @ VS=+/-15V, VCM=0V 6. Input Offset Voltage1 4 (V) @ VS=+/-15V, VCM=0V 7. Input Offset Current1 1 (A) @ VS=+/-15V, VCM=0V 8. Input Offset Current1 2 (A) @ VS=+/-15V, VCM=0V 9. Input Offset Current1 3 (A) @ VS=+/-15V, VCM=0V 10. Input Offset Current1 4 (A) @ VS=+/-15V, VCM=0V 11. +Input Bias Current BIAS1 1 (A) @ VS=+/-15V, VCM=0V 12. +Input Bias Current BIAS1 2 (A) @ VS=+/-15V, VCM=0V 13. +Input Bias Current BIAS1 3 (A) @ VS=+/-15V, VCM=0V 14. +Input Bias Current BIAS1 4 (A) @ VS=+/-15V, VCM=0V 15. -Input Bias Current BIAS1 1 (A) @ VS=+/-15V, VCM=0V 16. -Input Bias Current BIAS1 2 (A) @ VS=+/-15V, VCM=0V 17. -Input Bias Current BIAS1 3 (A) @ VS=+/-15V, VCM=0V 18. -Input Bias Current BIAS1 4 (A) @ VS=+/-15V, VCM=0V 19. Input Offset Voltage2 1 (V) @ VS=+/-15V, VCM=15V 20. Input Offset Voltage2 2 (V) @ VS=+/-15V, VCM=15V 21. Input Offset Voltage2 3 (V) @ VS=+/-15V, VCM=15V 22. Input Offset Voltage2 4 (V) @ VS=+/-15V, VCM=15V 23. Input Offset Current2 1 (A) @ VS=+/-15V, VCM=15V 24. Input Offset Current2 2 (A) @ VS=+/-15V, VCM=15V 25. Input Offset Current2 3 (A) @ VS=+/-15V, VCM=15V 26. Input Offset Current2 4 (A) @ VS=+/-15V, VCM=15V 27. +Input Bias Current BIAS2 1 (A) @ VS=+/-15V, VCM=15V 28. +Input Bias Current BIAS2 2 (A) @ VS=+/-15V, VCM=15V 29. +Input Bias Current BIAS2 3 (A) @ VS=+/-15V, VCM=15V 30. +Input Bias Current BIAS2 4 (A) @ VS=+/-15V, VCM=15V 31. -Input Bias Current BIAS2 1 (A) @ VS=+/-15V, VCM=15V 32. -Input Bias Current BIAS2 2 (A) @ VS=+/-15V, VCM=15V 33. -Input Bias Current BIAS2 3 (A) @ VS=+/-15V, VCM=15V 34. -Input Bias Current BIAS2 4 (A) @ VS=+/-15V, VCM=15V 35. Input Offset Voltage3 1 (V) @ VS=+/-15V, VCM=-15V 36. Input Offset Voltage3 2 (V) @ VS=+/-15V, VCM=-15V 37. Input Offset Voltage3 3 (V) @ VS=+/-15V, VCM=-15V An ISO 9001:2008 and DSCC Certified Company 6 TID Report 12-275 120517 R1.0 38. Input Offset Voltage3 4 (V) @ VS=+/-15V, VCM=-15V 39. Input Offset Current3 1 (A) @ VS=+/-15V, VCM=-15V 40. Input Offset Current3 2 (A) @ VS=+/-15V, VCM=-15V 41. Input Offset Current3 3 (A) @ VS=+/-15V, VCM=-15V 42. Input Offset Current3 4 (A) @ VS=+/-15V, VCM=-15V 43. +Input Bias Current BIAS3 1 (A) @ VS=+/-15V, VCM=-15V 44. +Input Bias Current BIAS3 2 (A) @ VS=+/-15V, VCM=-15V 45. +Input Bias Current BIAS3 3 (A) @ VS=+/-15V, VCM=-15V 46. +Input Bias Current BIAS3 4 (A) @ VS=+/-15V, VCM=-15V 47. -Input Bias Current BIAS3 1 (A) @ VS=+/-15V, VCM=-15V 48. -Input Bias Current BIAS3 2 (A) @ VS=+/-15V, VCM=-15V 49. -Input Bias Current BIAS3 3 (A) @ VS=+/-15V, VCM=-15V 50. -Input Bias Current BIAS3 4 (A) @ VS=+/-15V, VCM=-15V 51. Output Voltage Swing High1 1 (V) @ VS=+/-15V IL=0mA 52. Output Voltage Swing High1 2 (V) @ VS=+/-15V IL=0mA 53. Output Voltage Swing High1 3 (V) @ VS=+/-15V IL=0mA 54. Output Voltage Swing High1 4 (V) @ VS=+/-15V IL=0mA 55. Output Voltage Swing High2 1 (V) @ VS=+/-15V IL=1mA 56. Output Voltage Swing High2 2 (V) @ VS=+/-15V IL=1mA 57. Output Voltage Swing High2 3 (V) @ VS=+/-15V IL=1mA 58. Output Voltage Swing High2 4 (V) @ VS=+/-15V IL=1mA 59. Output Voltage Swing High3 1 (V) @ VS=+/-15V IL=10mA 60. Output Voltage Swing High3 2 (V) @ VS=+/-15V IL=10mA 61. Output Voltage Swing High3 3 (V) @ VS=+/-15V IL=10mA 62. Output Voltage Swing High3 4 (V) @ VS=+/-15V IL=10mA 63. Output Voltage Swing Low1 1 (V) @ VS=+/-15V IL=0mA 64. Output Voltage Swing Low1 2 (V) @ VS=+/-15V IL=0mA 65. Output Voltage Swing Low1 3 (V) @ VS=+/-15V IL=0mA 66. Output Voltage Swing Low1 4 (V) @ VS=+/-15V IL=0mA 67. Output Voltage Swing Low2 1 (V) @ VS=+/-15V IL=1mA 68. Output Voltage Swing Low2 2 (V) @ VS=+/-15V IL=1mA 69. Output Voltage Swing Low2 3 (V) @ VS=+/-15V IL=1mA 70. Output Voltage Swing Low2 4 (V) @ VS=+/-15V IL=1mA 71. Output Voltage Swing Low3 1 (V) @ VS=+/-15V IL=10mA 72. Output Voltage Swing Low3 2 (V) @ VS=+/-15V IL=10mA 73. Output Voltage Swing Low3 3 (V) @ VS=+/-15V IL=10mA 74. Output Voltage Swing Low3 4 (V) @ VS=+/-15V IL=10mA 75. Large Signal Voltage Gain1 1 (V/mV) @ VO=+/-14.5V, RL=10kΩ 76. Large Signal Voltage Gain1 2 (V/mV) @ VO=+/-14.5V, RL=10kΩ 77. Large Signal Voltage Gain1 3 (V/mV) @ VO=+/-14.5V, RL=10kΩ 78. Large Signal Voltage Gain1 4 (V/mV) @ VO=+/-14.5V, RL=10kΩ 79. Large Signal Voltage Gain2 1 (V/mV) @ VO=+/-10V, RL=2kΩ An ISO 9001:2008 and DSCC Certified Company 7 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 TID Report 12-275 120517 R1.0 80. Large Signal Voltage Gain2 2 (V/mV) @ VO=+/-10V, RL=2kΩ 81. Large Signal Voltage Gain2 3 (V/mV) @ VO=+/-10V, RL=2kΩ 82. Large Signal Voltage Gain2 4 (V/mV) @ VO=+/-10V, RL=2kΩ 83. Common Mode Rejection Ratio1 1 (dB) @ VS=+/-15V, VCM=+/-15V 84. Common Mode Rejection Ratio1 2 (dB) @ VS=+/-15V, VCM=+/-15V 85. Common Mode Rejection Ratio1 3 (dB) @ VS=+/-15V, VCM=+/-15V 86. Common Mode Rejection Ratio1 4 (dB) @ VS=+/-15V, VCM=+/-15V 87. CMRR Match1 1 to 4 (dB) @ VS=+/-15V, VCM=+/-15V 88. CMRR Match1 2 to 3 (dB) @ VS=+/-15V, VCM=+/-15V 89. Power Supply Rejection Ratio1 1 (dB) @ VS=+/-2V to +/-16V 90. Power Supply Rejection Ratio1 2 (dB) @ VS=+/-2V to +/-16V 91. Power Supply Rejection Ratio1 3 (dB) @ VS=+/-2V to +/-16V 92. Power Supply Rejection Ratio1 4 (dB) @ VS=+/-2V to +/-16V 93. PSRR Match1 1 to 4 (dB) @ VS=+/-2V to +/-16V 94. PSRR Match1 2 to 3 (dB) @ VS=+/-2V to +/-16V 95. +Short-Circuit Current1 1 (A) @ VS=+/-15V, VOUT=0V 96. +Short-Circuit Current1 2 (A) @ VS=+/-15V, VOUT=0V 97. +Short-Circuit Current1 3 (A) @ VS=+/-15V, VOUT=0V 98. +Short-Circuit Current1 4 (A) @ VS=+/-15V, VOUT=0V 99. -Short-Circuit Current1 1 (A) @ VS=+/-15V, VOUT=0V 100. -Short-Circuit Current1 2 (A) @ VS=+/-15V, VOUT=0V 101. -Short-Circuit Current1 3 (A) @ VS=+/-15V, VOUT=0V 102. -Short-Circuit Current1 4 (A) @ VS=+/-15V, VOUT=0V 103. +Supply Current (A) @ VS=+5V 104. -Supply Current (A) @ VS=+5V 105. Input Offset Voltage4 1 (V) @ VS=+5V, VCM=0V 106. Input Offset Voltage4 2 (V) @ VS=+5V, VCM=0V 107. Input Offset Voltage4 3 (V) @ VS=+5V, VCM=0V 108. Input Offset Voltage4 4 (V) @ VS=+5V, VCM=0V 109. Input Offset Current4 1 (A) @ VS=+5V, VCM=0V 110. Input Offset Current4 2 (A) @ VS=+5V, VCM=0V 111. Input Offset Current4 3 (A) @ VS=+5V, VCM=0V 112. Input Offset Current4 4 (A) @ VS=+5V, VCM=0V 113. +Input Bias Current BIAS4 1 (A) @ VS=+5V, VCM=0V 114. +Input Bias Current BIAS4 2 (A) @ VS=+5V, VCM=0V 115. +Input Bias Current BIAS4 3 (A) @ VS=+5V, VCM=0V 116. +Input Bias Current BIAS4 4 (A) @ VS=+5V, VCM=0V 117. -Input Bias Current BIAS4 1 (A) @ VS=+5V, VCM=0V 118. -Input Bias Current BIAS4 2 (A) @ VS=+5V, VCM=0V 119. -Input Bias Current BIAS4 3 (A) @ VS=+5V, VCM=0V 120. -Input Bias Current BIAS4 4 (A) @ VS=+5V, VCM=0V 121. Input Offset Voltage5 1 (V) @ VS=+5V, VCM=5V An ISO 9001:2008 and DSCC Certified Company 8 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 TID Report 12-275 120517 R1.0 122. 123. 124. 125. 126. 127. 128. 129. 130. 131. 132. 133. 134. 135. 136. 137. 138. 139. 140. 141. 142. 143. 144. 145. 146. 147. 148. 149. 150. 151. 152. 153. 154. 155. 156. 157. 158. 159. 160. 161. 162. 163. Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Input Offset Voltage5 2 (V) @ VS=+5V, VCM=5V Input Offset Voltage5 3 (V) @ VS=+5V, VCM=5V Input Offset Voltage5 4 (V) @ VS=+5V, VCM=5V Input Offset Current5 1 (A) @ VS=+5V, VCM=5V Input Offset Current5 2 (A) @ VS=+5V, VCM=5V Input Offset Current5 3 (A) @ VS=+5V, VCM=5V Input Offset Current5 4 (A) @ VS=+5V, VCM=5V +Input Bias Current BIAS5 1 (A) @ VS=+5V, VCM=5V +Input Bias Current BIAS5 2 (A) @ VS=+5V, VCM=5V +Input Bias Current BIAS5 3 (A) @ VS=+5V, VCM=5V +Input Bias Current BIAS5 4 (A) @ VS=+5V, VCM=5V -Input Bias Current BIAS5 1 (A) @ VS=+5V, VCM=5V -Input Bias Current BIAS5 2 (A) @ VS=+5V, VCM=5V -Input Bias Current BIAS5 3 (A) @ VS=+5V, VCM=5V -Input Bias Current BIAS5 4 (A) @ VS=+5V, VCM=5V Output Voltage Swing High4 1 (V) @ VS=+5V IL=0mA Output Voltage Swing High4 2 (V) @ VS=+5V IL=0mA Output Voltage Swing High4 3 (V) @ VS=+5V IL=0mA Output Voltage Swing High4 4 (V) @ VS=+5V IL=0mA Output Voltage Swing High5 1 (V) @ VS=+5V IL=1mA Output Voltage Swing High5 2 (V) @ VS=+5V IL=1mA Output Voltage Swing High5 3 (V) @ VS=+5V IL=1mA Output Voltage Swing High5 4 (V) @ VS=+5V IL=1mA Output Voltage Swing High6 1 (V) @ VS=+5V IL=2.5mA Output Voltage Swing High6 2 (V) @ VS=+5V IL=2.5mA Output Voltage Swing High6 3 (V) @ VS=+5V IL=2.5mA Output Voltage Swing High6 4 (V) @ VS=+5V IL=2.5mA Output Voltage Swing Low4 1 (V) @ VS=+5V IL=0mA Output Voltage Swing Low4 2 (V) @ VS=+5V IL=0mA Output Voltage Swing Low4 3 (V) @ VS=+5V IL=0mA Output Voltage Swing Low4 4 (V) @ VS=+5V IL=0mA Output Voltage Swing Low5 1 (V) @ VS=+5V IL=1mA Output Voltage Swing Low5 2 (V) @ VS=+5V IL=1mA Output Voltage Swing Low5 3 (V) @ VS=+5V IL=1mA Output Voltage Swing Low5 4 (V) @ VS=+5V IL=1mA Output Voltage Swing Low6 1 (V) @ VS=+5V IL=2.5mA Output Voltage Swing Low6 2 (V) @ VS=+5V IL=2.5mA Output Voltage Swing Low6 3 (V) @ VS=+5V IL=2.5mA Output Voltage Swing Low6 4 (V) @ VS=+5V IL=2.5mA Large Signal Voltage Gain3 1 (V/mV) @ VO=75mV to 4.8V, RL=10kΩ Large Signal Voltage Gain3 2 (V/mV) @ VO=75mV to 4.8V, RL=10kΩ Large Signal Voltage Gain3 3 (V/mV) @ VO=75mV to 4.8V, RL=10kΩ An ISO 9001:2008 and DSCC Certified Company 9 TID Report 12-275 120517 R1.0 164. 165. 166. 167. 168. 169. 170. 171. 172. 173. 174. 175. 176. 177. 178. 179. 180. 181. 182. 183. 184. Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Large Signal Voltage Gain3 4 (V/mV) @ VO=75mV to 4.8V, RL=10kΩ Common Mode Rejection Ratio2 1 (dB) @ VS=+5V, VCM=0 to +5V Common Mode Rejection Ratio2 2 (dB) @ VS=+5V, VCM=0 to +5V Common Mode Rejection Ratio2 3 (dB) @ VS=+5V, VCM=0 to +5V Common Mode Rejection Ratio2 4 (dB) @ VS=+5V, VCM=0 to +5V CMRR Match2 1 to 4 (dB) @ VS=+5V, VCM=0 to +5V CMRR Match2 2 to 3 (dB) @ VS=+5V, VCM=0 to +5V Power Supply Rejection Ratio2 1 (dB) @ VS=+4.5V to +12V Power Supply Rejection Ratio2 2 (dB) @ VS=+4.5V to +12V Power Supply Rejection Ratio2 3 (dB) @ VS=+4.5V to +12V Power Supply Rejection Ratio2 4 (dB) @ VS=+4.5V to +12V PSRR Match2 1 to 4 (dB) @ VS=+4.5V to +12V PSRR Match2 2 to 3 (dB) @ VS=+4.5V to +12V +Short-Circuit Current2 1 (A) @ VS=+5V +Short-Circuit Current2 2 (A) @ VS=+5V +Short-Circuit Current2 3 (A) @ VS=+5V +Short-Circuit Current2 4 (A) @ VS=+5V -Short-Circuit Current2 1 (A) @ VS=+5V -Short-Circuit Current2 2 (A) @ VS=+5V -Short-Circuit Current2 3 (A) @ VS=+5V -Short-Circuit Current2 4 (A) @ VS=+5V Appendix C details the measured parameters, test conditions, pre-irradiation specification and measurement resolution for each of the measurements. The parametric data was obtained as "read and record" and all the raw data plus an attributes summary are contained in this report as well as in a separate Excel file. The attributes data contains the average, standard deviation and the average with the KTL values applied. The KTL value used in this work is 2.742 per MIL-HDBK-814 using one sided tolerance limits of 90/90 and a 5-piece sample size. The 90/90 KTL values were selected to match the statistical levels specified in the MIL-PRF-38535 sampling plan for the qualification of a radiation hardness assured (RHA) component. Note that the following criteria must be met for a device to pass the total ionizing dose test: following the radiation exposure each of the 5 pieces irradiated under electrical bias shall pass the specification value. The units irradiated without electrical bias and the KTL statistics are included in this report for reference only. If any of the 5 pieces irradiated under electrical bias exceed the device post radiation data sheet specification limits, then the lot could be logged as a failure. An ISO 9001:2008 and DSCC Certified Company 10 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 5.0. Total Ionizing Dose Test Results Based on this criterion the RH1499MW Quad Rail-to-Rail Input and Output Precision C-Load Op Amp (from the lot traceability information provided on the first page of this test report) PASSED the total ionizing dose test to the maximum tested dose level of 200krad(Si) with all parameters remaining within their datasheet specifications. Figures 5.1 through 5.184 show plots of all the measured parameters versus total ionizing dose while Tables 5.1 - 5.184 show the corresponding raw data for each of these parameters. In the data plots the solid diamonds are the average of the measured data points for the sample irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the units irradiated with all pins tied to ground. The black lines (solid or dashed) are the average of the data points after application of the KTL statistics on the sample irradiated in the biased condition while the shaded lines (solid or dashed) are the average of the data points after application of the KTL statistics on the sample irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. The control units, as expected, show no significant changes to any of the parameters. Therefore we can conclude that the electrical testing remained in control throughout the duration of the tests and the observed degradation was due to the radiation exposure. Appendix D lists the figures used in this section to facilitate the location of a particular parameter. An ISO 9001:2008 and DSCC Certified Company 11 TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased +Supply Current (A) @ VS=+/-15V 1.20E-02 1.00E-02 8.00E-03 6.00E-03 4.00E-03 2.00E-03 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.1. Plot of +Supply Current (A) @ VS=+/-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 12 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.1. Raw data for +Supply Current (A) @ VS=+/-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) +Supply Current (A) @ VS=+/-15V Device 0 20 50 100 200 519 7.56E-03 7.41E-03 7.48E-03 7.34E-03 7.36E-03 520 7.58E-03 7.49E-03 7.44E-03 7.43E-03 7.50E-03 521 7.76E-03 7.68E-03 7.63E-03 7.62E-03 7.62E-03 522 7.48E-03 7.37E-03 7.33E-03 7.31E-03 7.31E-03 524 7.64E-03 7.60E-03 7.51E-03 7.50E-03 7.55E-03 536 7.51E-03 7.48E-03 7.43E-03 7.41E-03 7.37E-03 537 7.46E-03 7.41E-03 7.37E-03 7.36E-03 7.32E-03 538 7.38E-03 7.33E-03 7.30E-03 7.29E-03 7.24E-03 539 7.50E-03 7.45E-03 7.42E-03 7.40E-03 7.36E-03 542 7.47E-03 7.43E-03 7.40E-03 7.37E-03 7.33E-03 543 7.30E-03 7.25E-03 7.25E-03 7.25E-03 7.26E-03 544 7.75E-03 7.74E-03 7.74E-03 7.75E-03 7.76E-03 Biased Statistics Average Biased 7.60E-03 7.51E-03 7.48E-03 7.44E-03 7.47E-03 Std Dev Biased 1.06E-04 1.29E-04 1.09E-04 1.27E-04 1.27E-04 Ps90%/90% (+KTL) Biased 7.89E-03 7.86E-03 7.77E-03 7.79E-03 7.82E-03 Ps90%/90% (-KTL) Biased 7.31E-03 7.15E-03 7.18E-03 7.09E-03 7.12E-03 Un-Biased Statistics Average Un-Biased 7.47E-03 7.42E-03 7.39E-03 7.37E-03 7.32E-03 Std Dev Un-Biased 5.17E-05 5.53E-05 5.05E-05 4.68E-05 5.32E-05 Ps90%/90% (+KTL) Un-Biased 7.61E-03 7.57E-03 7.52E-03 7.49E-03 7.47E-03 Ps90%/90% (-KTL) Un-Biased 7.32E-03 7.27E-03 7.25E-03 7.24E-03 7.18E-03 Specification MAX 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 13 TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased -Supply Current (A) @ VS=+/-15V 0.00E+00 -2.00E-03 -4.00E-03 -6.00E-03 -8.00E-03 -1.00E-02 -1.20E-02 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.2. Plot of -Supply Current (A) @ VS=+/-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 14 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.2. Raw data for -Supply Current (A) @ VS=+/-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Supply Current (A) @ VS=+/-15V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 -7.58E-03 -7.60E-03 -7.78E-03 -7.50E-03 -7.67E-03 -7.53E-03 -7.49E-03 -7.40E-03 -7.52E-03 -7.49E-03 -7.32E-03 -7.77E-03 Total 20 -7.43E-03 -7.51E-03 -7.70E-03 -7.39E-03 -7.62E-03 -7.50E-03 -7.44E-03 -7.35E-03 -7.47E-03 -7.45E-03 -7.27E-03 -7.76E-03 Dose (krad(Si)) 50 100 -7.50E-03 -7.36E-03 -7.46E-03 -7.45E-03 -7.65E-03 -7.64E-03 -7.35E-03 -7.33E-03 -7.53E-03 -7.52E-03 -7.45E-03 -7.43E-03 -7.39E-03 -7.39E-03 -7.33E-03 -7.31E-03 -7.44E-03 -7.42E-03 -7.42E-03 -7.39E-03 -7.27E-03 -7.27E-03 -7.76E-03 -7.77E-03 200 -7.38E-03 -7.52E-03 -7.64E-03 -7.33E-03 -7.57E-03 -7.39E-03 -7.34E-03 -7.25E-03 -7.38E-03 -7.34E-03 -7.28E-03 -7.78E-03 -7.62E-03 -7.53E-03 -7.49E-03 -7.46E-03 -7.49E-03 1.06E-04 1.29E-04 1.09E-04 1.27E-04 1.27E-04 -7.33E-03 -7.18E-03 -7.19E-03 -7.11E-03 -7.14E-03 -7.91E-03 -7.88E-03 -7.79E-03 -7.81E-03 -7.84E-03 -7.49E-03 5.20E-05 -7.34E-03 -7.63E-03 -1.00E-02 PASS -7.44E-03 5.54E-05 -7.29E-03 -7.59E-03 -1.00E-02 PASS -7.41E-03 5.01E-05 -7.27E-03 -7.54E-03 -1.00E-02 PASS -7.39E-03 4.66E-05 -7.26E-03 -7.51E-03 -1.00E-02 PASS An ISO 9001:2008 and DSCC Certified Company 15 -7.34E-03 5.33E-05 -7.19E-03 -7.49E-03 -1.00E-02 PASS Input Offset Voltage1 1 (V) @ VS=+/-15V, VCM=0V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.3. Plot of Input Offset Voltage1 1 (V) @ VS=+/-15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 16 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.3. Raw data for Input Offset Voltage1 1 (V) @ VS=+/-15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage1 1 (V) @ VS=+/-15V, VCM=0V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 3.10E-05 1.76E-04 -1.19E-04 -3.01E-04 -8.07E-05 6.98E-05 -1.32E-04 -1.72E-04 -3.56E-04 -3.82E-05 -3.69E-04 -2.36E-04 Total 20 6.57E-06 1.44E-04 -1.28E-04 -3.25E-04 -9.94E-05 5.38E-05 -1.45E-04 -1.68E-04 -3.55E-04 -5.43E-05 -3.69E-04 -2.35E-04 Dose (krad(Si)) 50 100 1.87E-05 5.13E-06 1.42E-04 1.35E-04 -1.33E-04 -1.38E-04 -3.22E-04 -3.30E-04 -9.67E-05 -8.81E-05 4.41E-05 3.50E-05 -1.54E-04 -1.63E-04 -1.79E-04 -1.99E-04 -3.66E-04 -3.74E-04 -6.77E-05 -7.56E-05 -3.70E-04 -3.70E-04 -2.35E-04 -2.35E-04 200 7.66E-06 1.24E-04 -1.46E-04 -3.33E-04 -8.49E-05 1.08E-05 -1.85E-04 -2.18E-04 -3.98E-04 -9.85E-05 -3.69E-04 -2.35E-04 -5.89E-05 -8.04E-05 -7.83E-05 -8.33E-05 -8.63E-05 1.77E-04 1.74E-04 1.74E-04 1.73E-04 1.71E-04 4.28E-04 3.95E-04 3.98E-04 3.90E-04 3.83E-04 -5.45E-04 -5.56E-04 -5.54E-04 -5.57E-04 -5.56E-04 -1.26E-04 1.59E-04 3.10E-04 -5.61E-04 -8.00E-04 PASS 8.00E-04 PASS -1.34E-04 1.51E-04 2.81E-04 -5.49E-04 -9.50E-04 PASS 9.50E-04 PASS -1.45E-04 1.51E-04 2.70E-04 -5.60E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 17 -1.55E-04 1.52E-04 2.61E-04 -5.72E-04 -9.50E-04 PASS 9.50E-04 PASS -1.78E-04 1.52E-04 2.38E-04 -5.93E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Voltage1 2 (V) @ VS=+/-15V, VCM=0V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.4. Plot of Input Offset Voltage1 2 (V) @ VS=+/-15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 18 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.4. Raw data for Input Offset Voltage1 2 (V) @ VS=+/-15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage1 2 (V) @ VS=+/-15V, VCM=0V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -2.36E-04 3.42E-05 -2.10E-04 -2.39E-04 5.79E-05 4.33E-05 -4.84E-04 -1.33E-04 -1.93E-04 -3.13E-04 -2.01E-04 -1.04E-04 Total 20 -2.78E-04 2.44E-05 -2.46E-04 -2.53E-04 2.91E-05 2.67E-05 -5.08E-04 -1.42E-04 -2.02E-04 -3.34E-04 -2.05E-04 -1.04E-04 Dose (krad(Si)) 50 100 -2.68E-04 -2.74E-04 2.43E-05 2.22E-05 -2.49E-04 -2.32E-04 -2.42E-04 -2.39E-04 1.70E-05 2.22E-05 1.68E-05 1.12E-05 -5.16E-04 -5.30E-04 -1.39E-04 -1.37E-04 -2.08E-04 -2.22E-04 -3.40E-04 -3.49E-04 -2.06E-04 -2.06E-04 -1.03E-04 -1.03E-04 200 -2.79E-04 2.41E-05 -2.29E-04 -2.31E-04 2.40E-05 -1.02E-05 -5.43E-04 -1.55E-04 -2.34E-04 -3.63E-04 -2.05E-04 -1.01E-04 -1.19E-04 -1.45E-04 -1.44E-04 -1.40E-04 -1.38E-04 1.51E-04 1.57E-04 1.50E-04 1.49E-04 1.49E-04 2.95E-04 2.86E-04 2.68E-04 2.68E-04 2.72E-04 -5.32E-04 -5.75E-04 -5.55E-04 -5.48E-04 -5.48E-04 -2.16E-04 1.98E-04 3.26E-04 -7.58E-04 -8.00E-04 PASS 8.00E-04 PASS -2.32E-04 2.01E-04 3.21E-04 -7.84E-04 -9.50E-04 PASS 9.50E-04 PASS -2.37E-04 2.02E-04 3.17E-04 -7.91E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 19 -2.45E-04 2.06E-04 3.19E-04 -8.10E-04 -9.50E-04 PASS 9.50E-04 PASS -2.61E-04 2.03E-04 2.95E-04 -8.17E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Voltage1 3 (V) @ VS=+/-15V, VCM=0V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.5. Plot of Input Offset Voltage1 3 (V) @ VS=+/-15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 20 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.5. Raw data for Input Offset Voltage1 3 (V) @ VS=+/-15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage1 3 (V) @ VS=+/-15V, VCM=0V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -5.49E-05 -8.10E-05 -1.47E-04 2.95E-06 -1.69E-04 -5.39E-04 -1.18E-04 -1.98E-04 -4.72E-05 -3.36E-05 -6.68E-05 -1.15E-04 Total 20 -4.93E-05 -1.13E-04 -1.74E-04 -8.40E-06 -1.97E-04 -5.55E-04 -1.49E-04 -2.15E-04 -2.58E-05 -5.13E-05 -6.99E-05 -1.14E-04 Dose (krad(Si)) 50 100 -4.44E-05 -4.64E-05 -1.20E-04 -1.25E-04 -1.73E-04 -1.75E-04 -1.06E-05 -1.42E-05 -2.20E-04 -2.25E-04 -5.60E-04 -5.72E-04 -1.56E-04 -1.71E-04 -2.26E-04 -2.44E-04 -3.85E-05 -5.46E-05 -6.51E-05 -8.47E-05 -7.08E-05 -6.92E-05 -1.16E-04 -1.13E-04 200 -4.22E-05 -1.28E-04 -1.74E-04 -2.01E-05 -2.35E-04 -6.01E-04 -1.90E-04 -2.66E-04 -7.14E-05 -1.11E-04 -6.82E-05 -1.12E-04 -8.98E-05 -1.08E-04 -1.13E-04 -1.17E-04 -1.20E-04 6.97E-05 8.01E-05 8.69E-05 8.73E-05 8.98E-05 1.01E-04 1.11E-04 1.25E-04 1.22E-04 1.26E-04 -2.81E-04 -3.28E-04 -3.52E-04 -3.56E-04 -3.66E-04 -1.87E-04 2.07E-04 3.81E-04 -7.55E-04 -8.00E-04 PASS 8.00E-04 PASS -1.99E-04 2.13E-04 3.85E-04 -7.83E-04 -9.50E-04 PASS 9.50E-04 PASS -2.09E-04 2.10E-04 3.66E-04 -7.84E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 21 -2.25E-04 2.08E-04 3.44E-04 -7.95E-04 -9.50E-04 PASS 9.50E-04 PASS -2.48E-04 2.11E-04 3.31E-04 -8.27E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Voltage1 4 (V) @ VS=+/-15V, VCM=0V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.6. Plot of Input Offset Voltage1 4 (V) @ VS=+/-15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 22 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.6. Raw data for Input Offset Voltage1 4 (V) @ VS=+/-15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage1 4 (V) @ VS=+/-15V, VCM=0V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -1.78E-04 -1.76E-04 -3.63E-05 -1.39E-04 1.18E-05 -1.70E-04 -4.90E-05 8.46E-05 -1.88E-04 -1.01E-05 1.83E-04 -1.00E-04 Total 20 -2.00E-04 -2.20E-04 -7.52E-05 -1.51E-04 -1.12E-05 -1.69E-04 -5.37E-05 7.91E-05 -1.91E-04 -2.80E-05 1.77E-04 -1.00E-04 Dose (krad(Si)) 50 100 -1.96E-04 -1.95E-04 -2.20E-04 -2.24E-04 -7.26E-05 -7.48E-05 -1.43E-04 -1.46E-04 -1.55E-05 -3.20E-06 -1.74E-04 -1.83E-04 -5.93E-05 -6.39E-05 7.48E-05 6.39E-05 -2.00E-04 -2.12E-04 -4.00E-05 -4.96E-05 1.75E-04 1.76E-04 -1.00E-04 -9.99E-05 200 -1.92E-04 -2.23E-04 -7.15E-05 -1.43E-04 1.63E-06 -2.04E-04 -7.78E-05 4.69E-05 -2.34E-04 -5.61E-05 1.79E-04 -9.92E-05 -1.04E-04 -1.31E-04 -1.29E-04 -1.29E-04 -1.25E-04 8.64E-05 8.74E-05 8.52E-05 9.01E-05 9.12E-05 1.33E-04 1.08E-04 1.04E-04 1.19E-04 1.25E-04 -3.41E-04 -3.71E-04 -3.63E-04 -3.76E-04 -3.75E-04 -6.63E-05 1.14E-04 2.45E-04 -3.78E-04 -8.00E-04 PASS 8.00E-04 PASS -7.27E-05 1.11E-04 2.30E-04 -3.76E-04 -9.50E-04 PASS 9.50E-04 PASS -7.98E-05 1.11E-04 2.25E-04 -3.84E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 23 -8.89E-05 1.11E-04 2.16E-04 -3.94E-04 -9.50E-04 PASS 9.50E-04 PASS -1.05E-04 1.15E-04 2.09E-04 -4.19E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Current1 1 (A) @ VS=+/-15V, VCM=0V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.7. Plot of Input Offset Current1 1 (A) @ VS=+/-15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 24 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.7. Raw data for Input Offset Current1 1 (A) @ VS=+/-15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current1 1 (A) @ VS=+/-15V, VCM=0V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 3.75E-09 1.55E-09 -8.40E-10 -3.86E-09 -1.70E-10 2.35E-09 8.40E-10 -3.46E-09 -6.61E-09 -1.28E-09 -1.39E-09 -5.91E-09 Total 20 4.14E-09 7.40E-10 -1.14E-09 -4.42E-09 -4.60E-10 2.75E-09 7.40E-10 -3.23E-09 -6.26E-09 -1.91E-09 -1.39E-09 -5.94E-09 Dose (krad(Si)) 50 100 4.13E-09 5.26E-09 8.90E-10 1.17E-09 -9.70E-10 -6.40E-10 -3.10E-09 -4.05E-09 -7.20E-10 -1.70E-10 3.13E-09 4.26E-09 1.02E-09 1.09E-09 -4.05E-09 -4.06E-09 -7.39E-09 -7.66E-09 -2.33E-09 -2.51E-09 -1.39E-09 -1.37E-09 -5.92E-09 -5.93E-09 200 6.03E-09 -8.60E-10 -2.10E-10 -4.95E-09 -3.00E-10 4.94E-09 1.22E-09 -3.75E-09 -9.18E-09 -2.98E-09 -1.36E-09 -5.89E-09 8.60E-11 -2.28E-10 4.60E-11 3.14E-10 -5.80E-11 2.83E-09 3.10E-09 2.69E-09 3.37E-09 3.93E-09 7.85E-09 8.28E-09 7.42E-09 9.55E-09 1.07E-08 -7.68E-09 -8.73E-09 -7.33E-09 -8.92E-09 -1.08E-08 -1.63E-09 3.54E-09 8.08E-09 -1.13E-08 -7.00E-08 PASS 7.00E-08 PASS -1.58E-09 3.50E-09 8.00E-09 -1.12E-08 -1.00E-07 PASS 1.00E-07 PASS -1.92E-09 4.15E-09 9.45E-09 -1.33E-08 -1.00E-07 PASS 1.00E-07 PASS An ISO 9001:2008 and DSCC Certified Company 25 -1.78E-09 4.61E-09 1.09E-08 -1.44E-08 -1.00E-07 PASS 1.00E-07 PASS -1.95E-09 5.34E-09 1.27E-08 -1.66E-08 -1.00E-07 PASS 1.00E-07 PASS Input Offset Current1 2 (A) @ VS=+/-15V, VCM=0V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.8. Plot of Input Offset Current1 2 (A) @ VS=+/-15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 26 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.8. Raw data for Input Offset Current1 2 (A) @ VS=+/-15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current1 2 (A) @ VS=+/-15V, VCM=0V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 5.10E-10 -2.87E-09 3.47E-09 -9.40E-10 -6.10E-10 3.76E-09 -4.88E-09 -7.50E-10 1.74E-09 -6.13E-09 -2.37E-09 5.98E-09 Total 20 -1.50E-10 -3.20E-09 2.88E-09 -1.00E-09 -7.90E-10 3.78E-09 -5.18E-09 -6.30E-10 2.15E-09 -5.97E-09 -2.36E-09 6.04E-09 Dose (krad(Si)) 50 100 -5.10E-10 -6.50E-10 -3.55E-09 -3.48E-09 3.65E-09 2.87E-09 -1.45E-09 -4.70E-10 -9.30E-10 -5.00E-10 3.75E-09 4.96E-09 -5.16E-09 -5.97E-09 -5.60E-10 -1.57E-09 1.72E-09 1.83E-09 -5.82E-09 -5.13E-09 -2.38E-09 -2.34E-09 6.10E-09 6.04E-09 200 -4.60E-10 -4.11E-09 2.55E-09 -2.90E-10 3.10E-10 3.58E-09 -5.36E-09 -1.26E-09 1.51E-09 -5.92E-09 -2.33E-09 5.95E-09 -8.80E-11 -4.52E-10 -5.58E-10 -4.46E-10 -4.00E-10 2.33E-09 2.19E-09 2.63E-09 2.25E-09 2.40E-09 6.31E-09 5.55E-09 6.64E-09 5.72E-09 6.17E-09 -6.48E-09 -6.45E-09 -7.76E-09 -6.61E-09 -6.97E-09 -1.25E-09 4.22E-09 1.03E-08 -1.28E-08 -7.00E-08 PASS 7.00E-08 PASS -1.17E-09 4.33E-09 1.07E-08 -1.30E-08 -1.00E-07 PASS 1.00E-07 PASS -1.21E-09 4.20E-09 1.03E-08 -1.27E-08 -1.00E-07 PASS 1.00E-07 PASS An ISO 9001:2008 and DSCC Certified Company 27 -1.18E-09 4.62E-09 1.15E-08 -1.39E-08 -1.00E-07 PASS 1.00E-07 PASS -1.49E-09 4.16E-09 9.93E-09 -1.29E-08 -1.00E-07 PASS 1.00E-07 PASS Input Offset Current1 3 (A) @ VS=+/-15V, VCM=0V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.9. Plot of Input Offset Current1 3 (A) @ VS=+/-15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 28 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.9. Raw data for Input Offset Current1 3 (A) @ VS=+/-15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current1 3 (A) @ VS=+/-15V, VCM=0V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 1.81E-09 -1.22E-09 -5.30E-10 -3.00E-10 -4.66E-09 -2.69E-09 -2.80E-09 2.30E-10 3.98E-09 -3.73E-09 -2.22E-09 -1.61E-09 Total 20 2.75E-09 -7.30E-10 5.00E-11 5.30E-10 -4.85E-09 -2.59E-09 -2.82E-09 2.90E-10 4.75E-09 -4.06E-09 -2.19E-09 -1.65E-09 Dose (krad(Si)) 50 100 2.53E-09 3.03E-09 -1.09E-09 -1.11E-09 7.00E-11 -3.20E-10 0.00E+00 1.10E-09 -4.99E-09 -5.84E-09 -3.27E-09 -2.16E-09 -2.59E-09 -2.80E-09 3.10E-10 4.50E-10 4.23E-09 4.18E-09 -4.47E-09 -4.95E-09 -2.23E-09 -2.21E-09 -1.70E-09 -1.66E-09 200 3.15E-09 -1.24E-09 3.00E-11 2.86E-09 -6.07E-09 -2.44E-09 -1.85E-09 -1.00E-10 4.88E-09 -7.08E-09 -2.22E-09 -1.63E-09 -9.80E-10 -4.50E-10 -6.96E-10 -6.28E-10 -2.54E-10 2.35E-09 2.78E-09 2.74E-09 3.31E-09 3.75E-09 5.46E-09 7.17E-09 6.82E-09 8.45E-09 1.00E-08 -7.42E-09 -8.07E-09 -8.21E-09 -9.71E-09 -1.05E-08 -1.00E-09 3.16E-09 7.65E-09 -9.66E-09 -7.00E-08 PASS 7.00E-08 PASS -8.86E-10 3.53E-09 8.80E-09 -1.06E-08 -1.00E-07 PASS 1.00E-07 PASS -1.16E-09 3.49E-09 8.41E-09 -1.07E-08 -1.00E-07 PASS 1.00E-07 PASS An ISO 9001:2008 and DSCC Certified Company 29 -1.06E-09 3.50E-09 8.55E-09 -1.07E-08 -1.00E-07 PASS 1.00E-07 PASS -1.32E-09 4.32E-09 1.05E-08 -1.32E-08 -1.00E-07 PASS 1.00E-07 PASS Input Offset Current1 4 (A) @ VS=+/-15V, VCM=0V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.10. Plot of Input Offset Current1 4 (A) @ VS=+/-15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 30 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.10. Raw data for Input Offset Current1 4 (A) @ VS=+/-15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current1 4 (A) @ VS=+/-15V, VCM=0V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 3.10E-10 -1.45E-09 -5.07E-09 -1.68E-09 1.54E-09 -1.80E-09 2.92E-09 5.70E-10 1.54E-09 5.22E-09 -4.41E-09 -4.73E-09 Total 20 3.00E-10 -1.37E-09 -5.50E-09 -1.73E-09 2.36E-09 -1.97E-09 3.04E-09 2.00E-10 2.26E-09 5.15E-09 -4.47E-09 -4.71E-09 Dose (krad(Si)) 50 100 5.90E-10 0.00E+00 -1.23E-09 -1.86E-09 -4.82E-09 -5.13E-09 -1.49E-09 -1.43E-09 3.22E-09 4.91E-09 -1.26E-09 -3.80E-10 2.89E-09 3.77E-09 -9.00E-11 6.50E-10 2.17E-09 3.04E-09 5.66E-09 4.52E-09 -4.51E-09 -4.49E-09 -4.67E-09 -4.69E-09 200 -3.40E-10 -1.92E-09 -4.40E-09 -1.02E-09 5.35E-09 2.10E-10 3.17E-09 -1.92E-09 2.20E-09 6.54E-09 -4.48E-09 -4.57E-09 -1.27E-09 -1.19E-09 -7.46E-10 -7.02E-10 -4.66E-10 2.50E-09 2.90E-09 2.95E-09 3.66E-09 3.60E-09 5.59E-09 6.77E-09 7.35E-09 9.32E-09 9.40E-09 -8.13E-09 -9.15E-09 -8.85E-09 -1.07E-08 -1.03E-08 1.69E-09 2.62E-09 8.87E-09 -5.49E-09 -7.00E-08 PASS 7.00E-08 PASS 1.74E-09 2.73E-09 9.21E-09 -5.74E-09 -1.00E-07 PASS 1.00E-07 PASS 1.87E-09 2.70E-09 9.27E-09 -5.53E-09 -1.00E-07 PASS 1.00E-07 PASS An ISO 9001:2008 and DSCC Certified Company 31 2.32E-09 2.09E-09 8.06E-09 -3.42E-09 -1.00E-07 PASS 1.00E-07 PASS 2.04E-09 3.19E-09 1.08E-08 -6.69E-09 -1.00E-07 PASS 1.00E-07 PASS +Input Bias Current BIAS1 1 (A) @ VS=+/-15V, VCM=0V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-06 1.00E-06 5.00E-07 0.00E+00 -5.00E-07 -1.00E-06 -1.50E-06 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.11. Plot of +Input Bias Current BIAS1 1 (A) @ VS=+/-15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 32 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.11. Raw data for +Input Bias Current BIAS1 1 (A) @ VS=+/-15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Input Bias Current BIAS1 1 (A) @ VS=+/-15V, VCM=0V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -2.40E-07 -2.50E-07 -2.52E-07 -2.53E-07 -2.36E-07 -2.27E-07 -2.39E-07 -2.28E-07 -2.30E-07 -2.49E-07 -2.45E-07 -2.73E-07 Total 20 -2.53E-07 -2.62E-07 -2.64E-07 -2.66E-07 -2.48E-07 -2.38E-07 -2.51E-07 -2.40E-07 -2.41E-07 -2.60E-07 -2.47E-07 -2.75E-07 Dose (krad(Si)) 50 100 -2.58E-07 -2.75E-07 -2.74E-07 -2.86E-07 -2.77E-07 -2.89E-07 -2.76E-07 -2.89E-07 -2.60E-07 -2.74E-07 -2.53E-07 -2.71E-07 -2.65E-07 -2.83E-07 -2.54E-07 -2.72E-07 -2.56E-07 -2.75E-07 -2.75E-07 -2.94E-07 -2.47E-07 -2.47E-07 -2.75E-07 -2.74E-07 -2.46E-07 -2.59E-07 -2.69E-07 -2.82E-07 -3.05E-07 7.84E-09 7.64E-09 9.31E-09 7.44E-09 8.43E-09 -2.25E-07 -2.38E-07 -2.44E-07 -2.62E-07 -2.81E-07 -2.67E-07 -2.80E-07 -2.95E-07 -3.03E-07 -3.28E-07 -2.35E-07 9.10E-09 -2.10E-07 -2.60E-07 -7.15E-07 PASS 7.15E-07 PASS -2.46E-07 9.37E-09 -2.20E-07 -2.72E-07 -8.15E-07 PASS 8.15E-07 PASS -2.61E-07 9.26E-09 -2.35E-07 -2.86E-07 -8.65E-07 PASS 8.65E-07 PASS An ISO 9001:2008 and DSCC Certified Company 33 200 -2.94E-07 -3.10E-07 -3.11E-07 -3.11E-07 -2.97E-07 -3.02E-07 -3.13E-07 -3.03E-07 -3.05E-07 -3.26E-07 -2.47E-07 -2.73E-07 -2.79E-07 9.66E-09 -2.53E-07 -3.05E-07 -9.15E-07 PASS 9.15E-07 PASS -3.10E-07 1.01E-08 -2.82E-07 -3.38E-07 -9.65E-07 PASS 9.65E-07 PASS +Input Bias Current BIAS1 2 (A) @ VS=+/-15V, VCM=0V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-06 1.00E-06 5.00E-07 0.00E+00 -5.00E-07 -1.00E-06 -1.50E-06 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.12. Plot of +Input Bias Current BIAS1 2 (A) @ VS=+/-15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 34 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.12. Raw data for +Input Bias Current BIAS1 2 (A) @ VS=+/-15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Input Bias Current BIAS1 2 (A) @ VS=+/-15V, VCM=0V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -2.48E-07 -2.43E-07 -2.84E-07 -2.46E-07 -2.18E-07 -2.30E-07 -2.45E-07 -2.27E-07 -2.55E-07 -2.52E-07 -1.88E-07 -2.47E-07 Total 20 -2.60E-07 -2.53E-07 -2.95E-07 -2.57E-07 -2.28E-07 -2.39E-07 -2.56E-07 -2.37E-07 -2.66E-07 -2.62E-07 -1.90E-07 -2.48E-07 Dose (krad(Si)) 50 100 -2.64E-07 -2.80E-07 -2.64E-07 -2.74E-07 -3.06E-07 -3.16E-07 -2.67E-07 -2.76E-07 -2.36E-07 -2.47E-07 -2.52E-07 -2.68E-07 -2.69E-07 -2.86E-07 -2.48E-07 -2.64E-07 -2.79E-07 -2.95E-07 -2.75E-07 -2.92E-07 -1.90E-07 -1.90E-07 -2.48E-07 -2.48E-07 -2.48E-07 -2.59E-07 -2.67E-07 -2.79E-07 -2.97E-07 2.37E-08 2.38E-08 2.47E-08 2.49E-08 2.58E-08 -1.83E-07 -1.93E-07 -2.00E-07 -2.10E-07 -2.27E-07 -3.13E-07 -3.24E-07 -3.35E-07 -3.47E-07 -3.68E-07 -2.42E-07 1.27E-08 -2.07E-07 -2.77E-07 -7.15E-07 PASS 7.15E-07 PASS -2.52E-07 1.32E-08 -2.16E-07 -2.88E-07 -8.15E-07 PASS 8.15E-07 PASS -2.65E-07 1.37E-08 -2.27E-07 -3.02E-07 -8.65E-07 PASS 8.65E-07 PASS An ISO 9001:2008 and DSCC Certified Company 35 200 -2.96E-07 -2.94E-07 -3.37E-07 -2.95E-07 -2.64E-07 -2.94E-07 -3.12E-07 -2.89E-07 -3.22E-07 -3.21E-07 -1.89E-07 -2.46E-07 -2.81E-07 1.41E-08 -2.43E-07 -3.20E-07 -9.15E-07 PASS 9.15E-07 PASS -3.08E-07 1.54E-08 -2.65E-07 -3.50E-07 -9.65E-07 PASS 9.65E-07 PASS +Input Bias Current BIAS1 3 (A) @ VS=+/-15V, VCM=0V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-06 1.00E-06 5.00E-07 0.00E+00 -5.00E-07 -1.00E-06 -1.50E-06 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.13. Plot of +Input Bias Current BIAS1 3 (A) @ VS=+/-15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 36 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.13. Raw data for +Input Bias Current BIAS1 3 (A) @ VS=+/-15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Input Bias Current BIAS1 3 (A) @ VS=+/-15V, VCM=0V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -2.45E-07 -2.29E-07 -2.87E-07 -2.45E-07 -2.22E-07 -2.31E-07 -2.45E-07 -2.31E-07 -2.52E-07 -2.49E-07 -1.88E-07 -2.47E-07 Total 20 -2.59E-07 -2.40E-07 -2.99E-07 -2.56E-07 -2.34E-07 -2.42E-07 -2.57E-07 -2.42E-07 -2.63E-07 -2.61E-07 -1.90E-07 -2.47E-07 Dose (krad(Si)) 50 100 -2.63E-07 -2.80E-07 -2.52E-07 -2.65E-07 -3.11E-07 -3.23E-07 -2.67E-07 -2.77E-07 -2.44E-07 -2.56E-07 -2.57E-07 -2.75E-07 -2.72E-07 -2.91E-07 -2.55E-07 -2.72E-07 -2.78E-07 -2.96E-07 -2.76E-07 -2.96E-07 -1.90E-07 -1.90E-07 -2.47E-07 -2.47E-07 -2.46E-07 -2.58E-07 -2.67E-07 -2.80E-07 -3.02E-07 2.52E-08 2.53E-08 2.62E-08 2.59E-08 2.81E-08 -1.76E-07 -1.88E-07 -1.96E-07 -2.09E-07 -2.25E-07 -3.15E-07 -3.27E-07 -3.39E-07 -3.51E-07 -3.79E-07 -2.42E-07 9.99E-09 -2.14E-07 -2.69E-07 -7.15E-07 PASS 7.15E-07 PASS -2.53E-07 1.04E-08 -2.24E-07 -2.82E-07 -8.15E-07 PASS 8.15E-07 PASS -2.68E-07 1.07E-08 -2.38E-07 -2.97E-07 -8.65E-07 PASS 8.65E-07 PASS An ISO 9001:2008 and DSCC Certified Company 37 200 -2.98E-07 -2.86E-07 -3.50E-07 -2.97E-07 -2.78E-07 -3.05E-07 -3.23E-07 -3.00E-07 -3.25E-07 -3.28E-07 -1.90E-07 -2.46E-07 -2.86E-07 1.16E-08 -2.54E-07 -3.18E-07 -9.15E-07 PASS 9.15E-07 PASS -3.16E-07 1.27E-08 -2.81E-07 -3.51E-07 -9.65E-07 PASS 9.65E-07 PASS +Input Bias Current BIAS1 4 (A) @ VS=+/-15V, VCM=0V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-06 1.00E-06 5.00E-07 0.00E+00 -5.00E-07 -1.00E-06 -1.50E-06 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.14. Plot of +Input Bias Current BIAS1 4 (A) @ VS=+/-15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 38 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.14. Raw data for +Input Bias Current BIAS1 4 (A) @ VS=+/-15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Input Bias Current BIAS1 4 (A) @ VS=+/-15V, VCM=0V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -2.41E-07 -2.52E-07 -2.53E-07 -2.52E-07 -2.41E-07 -2.27E-07 -2.36E-07 -2.25E-07 -2.26E-07 -2.48E-07 -2.47E-07 -2.76E-07 Total 20 -2.54E-07 -2.62E-07 -2.63E-07 -2.64E-07 -2.52E-07 -2.37E-07 -2.46E-07 -2.35E-07 -2.35E-07 -2.58E-07 -2.50E-07 -2.77E-07 Dose (krad(Si)) 50 100 -2.58E-07 -2.74E-07 -2.72E-07 -2.83E-07 -2.74E-07 -2.84E-07 -2.74E-07 -2.85E-07 -2.61E-07 -2.73E-07 -2.49E-07 -2.64E-07 -2.58E-07 -2.72E-07 -2.47E-07 -2.63E-07 -2.47E-07 -2.62E-07 -2.72E-07 -2.89E-07 -2.50E-07 -2.50E-07 -2.77E-07 -2.76E-07 -2.48E-07 -2.59E-07 -2.68E-07 -2.80E-07 -2.99E-07 6.16E-09 5.68E-09 7.74E-09 5.89E-09 6.05E-09 -2.31E-07 -2.43E-07 -2.47E-07 -2.64E-07 -2.82E-07 -2.65E-07 -2.75E-07 -2.89E-07 -2.96E-07 -3.15E-07 -2.32E-07 9.80E-09 -2.05E-07 -2.59E-07 -7.15E-07 PASS 7.15E-07 PASS -2.42E-07 1.01E-08 -2.15E-07 -2.70E-07 -8.15E-07 PASS 8.15E-07 PASS -2.55E-07 1.06E-08 -2.25E-07 -2.84E-07 -8.65E-07 PASS 8.65E-07 PASS An ISO 9001:2008 and DSCC Certified Company 39 200 -2.92E-07 -3.02E-07 -3.03E-07 -3.04E-07 -2.93E-07 -2.90E-07 -2.99E-07 -2.89E-07 -2.87E-07 -3.16E-07 -2.49E-07 -2.75E-07 -2.70E-07 1.13E-08 -2.39E-07 -3.01E-07 -9.15E-07 PASS 9.15E-07 PASS -2.96E-07 1.21E-08 -2.63E-07 -3.30E-07 -9.65E-07 PASS 9.65E-07 PASS -Input Bias Current BIAS1 1 (A) @ VS=+/-15V, VCM=0V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-06 1.00E-06 5.00E-07 0.00E+00 -5.00E-07 -1.00E-06 -1.50E-06 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.15. Plot of -Input Bias Current BIAS1 1 (A) @ VS=+/-15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 40 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.15. Raw data for -Input Bias Current BIAS1 1 (A) @ VS=+/-15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Input Bias Current BIAS1 1 (A) @ VS=+/-15V, VCM=0V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -2.43E-07 -2.51E-07 -2.51E-07 -2.48E-07 -2.35E-07 -2.29E-07 -2.39E-07 -2.24E-07 -2.23E-07 -2.47E-07 -2.43E-07 -2.67E-07 Total 20 -2.57E-07 -2.62E-07 -2.62E-07 -2.61E-07 -2.47E-07 -2.40E-07 -2.51E-07 -2.36E-07 -2.34E-07 -2.58E-07 -2.46E-07 -2.68E-07 Dose (krad(Si)) 50 100 -2.62E-07 -2.79E-07 -2.75E-07 -2.87E-07 -2.75E-07 -2.88E-07 -2.73E-07 -2.84E-07 -2.59E-07 -2.74E-07 -2.55E-07 -2.74E-07 -2.65E-07 -2.83E-07 -2.49E-07 -2.68E-07 -2.48E-07 -2.67E-07 -2.72E-07 -2.91E-07 -2.45E-07 -2.45E-07 -2.68E-07 -2.67E-07 -2.46E-07 -2.58E-07 -2.69E-07 -2.82E-07 -3.04E-07 6.74E-09 6.45E-09 7.73E-09 5.87E-09 5.97E-09 -2.27E-07 -2.40E-07 -2.48E-07 -2.66E-07 -2.88E-07 -2.64E-07 -2.76E-07 -2.90E-07 -2.99E-07 -3.21E-07 -2.33E-07 1.02E-08 -2.04E-07 -2.61E-07 -7.15E-07 PASS 7.15E-07 PASS -2.44E-07 1.02E-08 -2.16E-07 -2.72E-07 -8.15E-07 PASS 8.15E-07 PASS -2.58E-07 1.04E-08 -2.30E-07 -2.87E-07 -8.65E-07 PASS 8.65E-07 PASS An ISO 9001:2008 and DSCC Certified Company 41 200 -3.00E-07 -3.09E-07 -3.10E-07 -3.06E-07 -2.96E-07 -3.06E-07 -3.13E-07 -2.98E-07 -2.95E-07 -3.22E-07 -2.45E-07 -2.66E-07 -2.77E-07 1.03E-08 -2.48E-07 -3.05E-07 -9.15E-07 PASS 9.15E-07 PASS -3.07E-07 1.10E-08 -2.76E-07 -3.37E-07 -9.65E-07 PASS 9.65E-07 PASS -Input Bias Current BIAS1 2 (A) @ VS=+/-15V, VCM=0V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-06 1.00E-06 5.00E-07 0.00E+00 -5.00E-07 -1.00E-06 -1.50E-06 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.16. Plot of -Input Bias Current BIAS1 2 (A) @ VS=+/-15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 42 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.16. Raw data for -Input Bias Current BIAS1 2 (A) @ VS=+/-15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Input Bias Current BIAS1 2 (A) @ VS=+/-15V, VCM=0V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -2.48E-07 -2.40E-07 -2.87E-07 -2.45E-07 -2.17E-07 -2.33E-07 -2.40E-07 -2.26E-07 -2.56E-07 -2.45E-07 -1.86E-07 -2.52E-07 Total 20 -2.60E-07 -2.50E-07 -2.97E-07 -2.56E-07 -2.27E-07 -2.42E-07 -2.50E-07 -2.36E-07 -2.67E-07 -2.56E-07 -1.87E-07 -2.53E-07 Dose (krad(Si)) 50 100 -2.64E-07 -2.79E-07 -2.60E-07 -2.71E-07 -3.09E-07 -3.18E-07 -2.65E-07 -2.75E-07 -2.35E-07 -2.46E-07 -2.56E-07 -2.72E-07 -2.63E-07 -2.79E-07 -2.47E-07 -2.62E-07 -2.80E-07 -2.97E-07 -2.69E-07 -2.86E-07 -1.87E-07 -1.87E-07 -2.53E-07 -2.53E-07 -2.47E-07 -2.58E-07 -2.67E-07 -2.78E-07 -2.96E-07 2.53E-08 2.51E-08 2.66E-08 2.61E-08 2.67E-08 -1.78E-07 -1.89E-07 -1.94E-07 -2.06E-07 -2.23E-07 -3.17E-07 -3.27E-07 -3.39E-07 -3.49E-07 -3.70E-07 -2.40E-07 1.16E-08 -2.08E-07 -2.72E-07 -7.15E-07 PASS 7.15E-07 PASS -2.50E-07 1.21E-08 -2.17E-07 -2.84E-07 -8.15E-07 PASS 8.15E-07 PASS -2.63E-07 1.24E-08 -2.29E-07 -2.97E-07 -8.65E-07 PASS 8.65E-07 PASS An ISO 9001:2008 and DSCC Certified Company 43 200 -2.96E-07 -2.90E-07 -3.38E-07 -2.94E-07 -2.64E-07 -2.97E-07 -3.06E-07 -2.86E-07 -3.23E-07 -3.14E-07 -1.87E-07 -2.52E-07 -2.79E-07 1.31E-08 -2.43E-07 -3.15E-07 -9.15E-07 PASS 9.15E-07 PASS -3.05E-07 1.43E-08 -2.66E-07 -3.44E-07 -9.65E-07 PASS 9.65E-07 PASS -Input Bias Current BIAS1 3 (A) @ VS=+/-15V, VCM=0V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-06 1.00E-06 5.00E-07 0.00E+00 -5.00E-07 -1.00E-06 -1.50E-06 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.17. Plot of -Input Bias Current BIAS1 3 (A) @ VS=+/-15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 44 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.17. Raw data for -Input Bias Current BIAS1 3 (A) @ VS=+/-15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Input Bias Current BIAS1 3 (A) @ VS=+/-15V, VCM=0V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -2.47E-07 -2.27E-07 -2.86E-07 -2.44E-07 -2.17E-07 -2.28E-07 -2.42E-07 -2.31E-07 -2.55E-07 -2.45E-07 -1.86E-07 -2.45E-07 Total 20 -2.61E-07 -2.39E-07 -2.98E-07 -2.56E-07 -2.29E-07 -2.38E-07 -2.54E-07 -2.42E-07 -2.67E-07 -2.56E-07 -1.88E-07 -2.45E-07 Dose (krad(Si)) 50 100 -2.66E-07 -2.82E-07 -2.51E-07 -2.63E-07 -3.11E-07 -3.22E-07 -2.66E-07 -2.78E-07 -2.38E-07 -2.51E-07 -2.53E-07 -2.72E-07 -2.69E-07 -2.88E-07 -2.55E-07 -2.72E-07 -2.81E-07 -2.99E-07 -2.72E-07 -2.90E-07 -1.88E-07 -1.88E-07 -2.45E-07 -2.45E-07 -2.44E-07 -2.57E-07 -2.66E-07 -2.79E-07 -3.01E-07 2.62E-08 2.64E-08 2.73E-08 2.70E-08 2.93E-08 -1.72E-07 -1.84E-07 -1.91E-07 -2.05E-07 -2.21E-07 -3.16E-07 -3.29E-07 -3.41E-07 -3.53E-07 -3.81E-07 -2.40E-07 1.12E-08 -2.09E-07 -2.71E-07 -7.15E-07 PASS 7.15E-07 PASS -2.51E-07 1.15E-08 -2.20E-07 -2.83E-07 -8.15E-07 PASS 8.15E-07 PASS -2.66E-07 1.18E-08 -2.34E-07 -2.98E-07 -8.65E-07 PASS 8.65E-07 PASS An ISO 9001:2008 and DSCC Certified Company 45 200 -3.01E-07 -2.84E-07 -3.49E-07 -3.00E-07 -2.72E-07 -3.01E-07 -3.20E-07 -3.00E-07 -3.29E-07 -3.21E-07 -1.88E-07 -2.44E-07 -2.84E-07 1.19E-08 -2.52E-07 -3.17E-07 -9.15E-07 PASS 9.15E-07 PASS -3.14E-07 1.28E-08 -2.79E-07 -3.49E-07 -9.65E-07 PASS 9.65E-07 PASS -Input Bias Current BIAS1 4 (A) @ VS=+/-15V, VCM=0V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-06 1.00E-06 5.00E-07 0.00E+00 -5.00E-07 -1.00E-06 -1.50E-06 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.18. Plot of -Input Bias Current BIAS1 4 (A) @ VS=+/-15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 46 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.18. Raw data for -Input Bias Current BIAS1 4 (A) @ VS=+/-15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Input Bias Current BIAS1 4 (A) @ VS=+/-15V, VCM=0V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -2.42E-07 -2.50E-07 -2.48E-07 -2.50E-07 -2.42E-07 -2.25E-07 -2.38E-07 -2.25E-07 -2.27E-07 -2.53E-07 -2.42E-07 -2.70E-07 Total 20 -2.54E-07 -2.60E-07 -2.58E-07 -2.62E-07 -2.54E-07 -2.34E-07 -2.48E-07 -2.35E-07 -2.37E-07 -2.63E-07 -2.45E-07 -2.71E-07 Dose (krad(Si)) 50 100 -2.58E-07 -2.74E-07 -2.70E-07 -2.81E-07 -2.69E-07 -2.79E-07 -2.72E-07 -2.83E-07 -2.64E-07 -2.77E-07 -2.47E-07 -2.63E-07 -2.61E-07 -2.76E-07 -2.46E-07 -2.62E-07 -2.49E-07 -2.65E-07 -2.77E-07 -2.93E-07 -2.45E-07 -2.45E-07 -2.72E-07 -2.71E-07 -2.46E-07 -2.57E-07 -2.67E-07 -2.79E-07 -2.98E-07 4.10E-09 3.61E-09 5.59E-09 3.45E-09 4.24E-09 -2.35E-07 -2.48E-07 -2.51E-07 -2.69E-07 -2.86E-07 -2.58E-07 -2.67E-07 -2.82E-07 -2.88E-07 -3.09E-07 -2.34E-07 1.21E-08 -2.00E-07 -2.67E-07 -7.15E-07 PASS 7.15E-07 PASS -2.43E-07 1.22E-08 -2.10E-07 -2.77E-07 -8.15E-07 PASS 8.15E-07 PASS -2.56E-07 1.29E-08 -2.21E-07 -2.91E-07 -8.65E-07 PASS 8.65E-07 PASS An ISO 9001:2008 and DSCC Certified Company 47 200 -2.91E-07 -2.99E-07 -2.98E-07 -3.03E-07 -2.98E-07 -2.89E-07 -3.02E-07 -2.87E-07 -2.89E-07 -3.22E-07 -2.45E-07 -2.70E-07 -2.72E-07 1.30E-08 -2.36E-07 -3.08E-07 -9.15E-07 PASS 9.15E-07 PASS -2.98E-07 1.46E-08 -2.58E-07 -3.38E-07 -9.65E-07 PASS 9.65E-07 PASS Input Offset Voltage2 1 (V) @ VS=+/-15V, VCM=15V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.19. Plot of Input Offset Voltage2 1 (V) @ VS=+/-15V, VCM=15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 48 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.19. Raw data for Input Offset Voltage2 1 (V) @ VS=+/-15V, VCM=15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage2 1 (V) @ VS=+/-15V, VCM=15V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 2.04E-04 3.92E-04 1.41E-04 1.93E-04 2.76E-04 6.49E-05 1.95E-04 7.66E-05 5.84E-06 2.27E-04 7.32E-05 2.32E-04 Total 20 1.78E-04 3.60E-04 1.10E-04 1.76E-04 2.57E-04 4.80E-05 1.81E-04 7.32E-05 1.12E-05 2.14E-04 7.18E-05 2.31E-04 Dose (krad(Si)) 50 100 200 1.89E-04 1.79E-04 1.85E-04 3.62E-04 3.58E-04 3.61E-04 1.09E-04 1.05E-04 1.05E-04 1.86E-04 1.86E-04 1.94E-04 2.55E-04 2.63E-04 2.76E-04 4.12E-05 3.17E-05 1.23E-05 1.75E-04 1.69E-04 1.47E-04 7.04E-05 6.04E-05 5.09E-05 6.82E-06 6.60E-07 -1.90E-05 2.06E-04 2.03E-04 1.94E-04 7.12E-05 7.13E-05 7.18E-05 2.31E-04 2.32E-04 2.33E-04 2.41E-04 2.16E-04 2.20E-04 2.18E-04 2.24E-04 9.73E-05 9.58E-05 9.48E-05 9.62E-05 9.75E-05 5.08E-04 4.79E-04 4.80E-04 4.82E-04 4.92E-04 -2.59E-05 -4.66E-05 -3.99E-05 -4.53E-05 -4.29E-05 1.14E-04 9.33E-05 3.70E-04 -1.42E-04 -8.00E-04 PASS 8.00E-04 PASS 1.05E-04 8.77E-05 3.46E-04 -1.35E-04 -9.50E-04 PASS 9.50E-04 PASS 9.99E-05 8.65E-05 3.37E-04 -1.37E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 49 9.29E-05 8.83E-05 3.35E-04 -1.49E-04 -9.50E-04 PASS 9.50E-04 PASS 7.71E-05 9.04E-05 3.25E-04 -1.71E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Voltage2 2 (V) @ VS=+/-15V, VCM=15V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.20. Plot of Input Offset Voltage2 2 (V) @ VS=+/-15V, VCM=15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 50 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.20. Raw data for Input Offset Voltage2 2 (V) @ VS=+/-15V, VCM=15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage2 2 (V) @ VS=+/-15V, VCM=15V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 1.53E-05 1.85E-04 5.84E-06 3.35E-05 8.63E-05 6.55E-05 -3.62E-05 2.21E-04 1.88E-04 5.72E-05 -3.06E-04 1.01E-04 Total 20 -1.46E-05 1.85E-04 -4.15E-05 1.59E-05 3.58E-05 4.87E-05 -4.55E-05 2.12E-04 1.77E-04 3.98E-05 -3.09E-04 1.01E-04 Dose (krad(Si)) 50 100 -7.07E-06 -8.27E-06 1.87E-04 1.90E-04 -4.14E-05 -2.63E-05 2.94E-05 3.69E-05 2.95E-05 4.51E-05 4.27E-05 4.01E-05 -5.48E-05 -5.84E-05 2.16E-04 2.20E-04 1.75E-04 1.66E-04 3.64E-05 2.70E-05 -3.10E-04 -3.09E-04 1.02E-04 1.02E-04 200 -6.34E-06 1.99E-04 -1.59E-05 5.15E-05 5.99E-05 2.20E-05 -7.19E-05 2.09E-04 1.60E-04 1.80E-05 -3.09E-04 1.03E-04 6.53E-05 3.60E-05 3.95E-05 4.75E-05 5.76E-05 7.41E-05 8.81E-05 8.76E-05 8.51E-05 8.58E-05 2.68E-04 2.78E-04 2.80E-04 2.81E-04 2.93E-04 -1.38E-04 -2.06E-04 -2.01E-04 -1.86E-04 -1.78E-04 9.90E-05 1.05E-04 3.86E-04 -1.88E-04 -8.00E-04 PASS 8.00E-04 PASS 8.63E-05 1.06E-04 3.77E-04 -2.04E-04 -9.50E-04 PASS 9.50E-04 PASS 8.31E-05 1.11E-04 3.87E-04 -2.20E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 51 7.91E-05 1.13E-04 3.88E-04 -2.30E-04 -9.50E-04 PASS 9.50E-04 PASS 6.74E-05 1.15E-04 3.82E-04 -2.47E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Voltage2 3 (V) @ VS=+/-15V, VCM=15V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.21. Plot of Input Offset Voltage2 3 (V) @ VS=+/-15V, VCM=15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 52 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.21. Raw data for Input Offset Voltage2 3 (V) @ VS=+/-15V, VCM=15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage2 3 (V) @ VS=+/-15V, VCM=15V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total Dose (krad(Si)) 0 20 50 100 200 1.72E-04 2.18E-04 2.20E-04 2.13E-04 2.18E-04 3.41E-04 3.03E-04 3.00E-04 3.01E-04 3.07E-04 1.68E-04 1.41E-04 1.28E-04 1.44E-04 1.49E-04 1.58E-04 1.32E-04 1.37E-04 1.40E-04 1.42E-04 1.03E-05 -1.48E-05 -3.04E-05 -2.75E-05 -2.65E-05 -2.23E-04 -2.38E-04 -2.41E-04 -2.47E-04 -2.70E-04 1.38E-04 1.15E-04 1.14E-04 1.04E-04 9.39E-05 1.03E-04 8.84E-05 8.34E-05 7.43E-05 5.80E-05 1.58E-04 1.84E-04 1.75E-04 1.66E-04 1.53E-04 7.50E-05 5.62E-05 4.93E-05 3.86E-05 2.54E-05 1.71E-04 1.70E-04 1.70E-04 1.71E-04 1.72E-04 1.71E-04 1.71E-04 1.71E-04 1.72E-04 1.74E-04 1.70E-04 1.56E-04 1.51E-04 1.54E-04 1.58E-04 1.17E-04 1.18E-04 1.23E-04 1.21E-04 1.23E-04 4.90E-04 4.78E-04 4.89E-04 4.85E-04 4.94E-04 -1.51E-04 -1.67E-04 -1.87E-04 -1.77E-04 -1.78E-04 5.04E-05 1.56E-04 4.78E-04 -3.77E-04 -8.00E-04 PASS 8.00E-04 PASS 4.13E-05 1.63E-04 4.88E-04 -4.06E-04 -9.50E-04 PASS 9.50E-04 PASS 3.62E-05 1.62E-04 4.80E-04 -4.08E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 53 2.71E-05 1.60E-04 4.67E-04 -4.12E-04 -9.50E-04 PASS 9.50E-04 PASS 1.20E-05 1.64E-04 4.63E-04 -4.39E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Voltage2 4 (V) @ VS=+/-15V, VCM=15V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.22. Plot of Input Offset Voltage2 4 (V) @ VS=+/-15V, VCM=15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 54 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.22. Raw data for Input Offset Voltage2 4 (V) @ VS=+/-15V, VCM=15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage2 4 (V) @ VS=+/-15V, VCM=15V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total 0 20 1.15E-04 9.19E-05 7.06E-05 3.55E-05 1.98E-04 1.62E-04 6.98E-05 6.21E-05 2.73E-04 2.53E-04 -6.01E-05 -5.59E-05 2.65E-04 2.62E-04 2.55E-04 2.60E-04 1.33E-05 1.27E-05 5.69E-05 4.65E-05 3.19E-04 3.14E-04 1.68E-04 1.70E-04 Dose (krad(Si)) 50 100 200 9.39E-05 9.40E-05 1.00E-04 3.77E-05 3.76E-05 4.70E-05 1.65E-04 1.66E-04 1.76E-04 6.90E-05 7.14E-05 7.97E-05 2.47E-04 2.60E-04 2.74E-04 -5.80E-05 -6.44E-05 -7.60E-05 2.56E-04 2.49E-04 2.35E-04 2.59E-04 2.50E-04 2.41E-04 7.66E-06 -1.88E-06 -1.91E-05 3.69E-05 3.35E-05 2.26E-05 3.13E-04 3.14E-04 3.16E-04 1.70E-04 1.69E-04 1.70E-04 1.45E-04 1.21E-04 1.22E-04 1.26E-04 1.35E-04 8.84E-05 8.76E-05 8.39E-05 8.83E-05 9.08E-05 3.88E-04 3.61E-04 3.53E-04 3.68E-04 3.84E-04 -9.71E-05 -1.19E-04 -1.08E-04 -1.17E-04 -1.14E-04 1.06E-04 1.47E-04 5.09E-04 -2.96E-04 -8.00E-04 PASS 8.00E-04 PASS 1.05E-04 1.47E-04 5.09E-04 -2.98E-04 -9.50E-04 PASS 9.50E-04 PASS 1.00E-04 1.47E-04 5.04E-04 -3.04E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 55 9.33E-05 1.47E-04 4.96E-04 -3.10E-04 -9.50E-04 PASS 9.50E-04 PASS 8.08E-05 1.48E-04 4.86E-04 -3.25E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Current2 1 (A) @ VS=+/-15V, VCM=15V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.23. Plot of Input Offset Current2 1 (A) @ VS=+/-15V, VCM=15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 56 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.23. Raw data for Input Offset Current2 1 (A) @ VS=+/-15V, VCM=15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current2 1 (A) @ VS=+/-15V, VCM=15V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 5.12E-09 1.88E-09 8.40E-10 6.38E-09 -1.19E-09 -5.70E-10 -8.30E-10 5.88E-09 -5.30E-09 3.05E-09 -1.50E-10 4.00E-10 Total 20 2.85E-09 1.60E-10 -1.60E-10 3.90E-09 -1.52E-09 -1.29E-09 -4.30E-10 4.09E-09 -1.72E-09 3.01E-09 -1.20E-10 1.50E-10 Dose (krad(Si)) 50 100 2.02E-09 1.31E-09 -5.40E-10 -2.23E-09 2.20E-10 -5.00E-11 4.03E-09 5.89E-09 -3.94E-09 -5.81E-09 -8.40E-10 -1.81E-09 -1.10E-09 4.30E-10 5.27E-09 5.03E-09 -3.08E-09 -4.69E-09 1.52E-09 1.41E-09 -1.50E-10 -2.10E-10 2.50E-10 1.80E-10 200 1.86E-09 -2.37E-09 2.65E-09 5.90E-09 -5.00E-09 -1.46E-09 -1.03E-09 5.40E-09 -7.19E-09 1.39E-09 -1.80E-10 2.00E-10 2.61E-09 1.05E-09 3.58E-10 -1.78E-10 6.08E-10 3.11E-09 2.25E-09 2.98E-09 4.33E-09 4.30E-09 1.11E-08 7.21E-09 8.53E-09 1.17E-08 1.24E-08 -5.91E-09 -5.12E-09 -7.82E-09 -1.20E-08 -1.12E-08 4.46E-10 4.24E-09 1.21E-08 -1.12E-08 -7.00E-08 PASS 7.00E-08 PASS 7.32E-10 2.64E-09 7.98E-09 -6.51E-09 -1.00E-07 PASS 1.00E-07 PASS 3.54E-10 3.20E-09 9.12E-09 -8.41E-09 -1.00E-07 PASS 1.00E-07 PASS An ISO 9001:2008 and DSCC Certified Company 57 7.40E-11 3.63E-09 1.00E-08 -9.88E-09 -1.00E-07 PASS 1.00E-07 PASS -5.78E-10 4.59E-09 1.20E-08 -1.32E-08 -1.00E-07 PASS 1.00E-07 PASS Input Offset Current2 2 (A) @ VS=+/-15V, VCM=15V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.24. Plot of Input Offset Current2 2 (A) @ VS=+/-15V, VCM=15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 58 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.24. Raw data for Input Offset Current2 2 (A) @ VS=+/-15V, VCM=15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current2 2 (A) @ VS=+/-15V, VCM=15V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total Dose (krad(Si)) 0 20 50 100 200 8.68E-09 8.37E-09 7.43E-09 6.67E-09 7.71E-09 -1.67E-09 -1.84E-09 -2.90E-09 -3.73E-09 -4.08E-09 1.05E-08 1.89E-09 2.96E-09 5.43E-09 9.84E-09 3.65E-09 2.64E-09 4.00E-09 5.41E-09 4.96E-09 6.65E-09 -2.18E-09 -3.22E-09 -1.73E-09 2.20E-09 2.72E-09 2.21E-09 2.53E-09 3.03E-09 2.16E-09 6.96E-09 5.95E-09 5.35E-09 6.42E-09 4.03E-09 1.06E-08 1.18E-08 1.20E-08 1.39E-08 1.25E-08 1.19E-08 1.11E-08 1.10E-08 9.38E-09 1.29E-08 -5.10E-10 -1.58E-09 -1.57E-09 -1.96E-09 -3.47E-09 1.43E-09 1.16E-09 1.20E-09 1.16E-09 1.14E-09 8.86E-09 8.81E-09 8.82E-09 9.16E-09 9.01E-09 5.57E-09 1.78E-09 1.65E-09 2.41E-09 4.13E-09 4.78E-09 4.27E-09 4.61E-09 4.77E-09 5.41E-09 1.87E-08 1.35E-08 1.43E-08 1.55E-08 1.90E-08 -7.55E-09 -9.94E-09 -1.10E-08 -1.07E-08 -1.07E-08 6.34E-09 5.24E-09 2.07E-08 -8.02E-09 -7.00E-08 PASS 7.00E-08 PASS 5.90E-09 5.74E-09 2.16E-08 -9.83E-09 -1.00E-07 PASS 1.00E-07 PASS 5.85E-09 5.71E-09 2.15E-08 -9.79E-09 -1.00E-07 PASS 1.00E-07 PASS An ISO 9001:2008 and DSCC Certified Company 59 6.15E-09 6.03E-09 2.27E-08 -1.04E-08 -1.00E-07 PASS 1.00E-07 PASS 5.61E-09 7.01E-09 2.48E-08 -1.36E-08 -1.00E-07 PASS 1.00E-07 PASS Input Offset Current2 3 (A) @ VS=+/-15V, VCM=15V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.25. Plot of Input Offset Current2 3 (A) @ VS=+/-15V, VCM=15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 60 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.25. Raw data for Input Offset Current2 3 (A) @ VS=+/-15V, VCM=15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current2 3 (A) @ VS=+/-15V, VCM=15V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -8.80E-10 3.40E-10 1.31E-08 -1.91E-09 -3.20E-10 -6.27E-09 -5.41E-09 1.34E-08 -2.98E-09 4.19E-09 -3.14E-09 -2.94E-09 Total 20 5.16E-09 -4.10E-10 1.27E-08 -4.03E-09 -2.92E-09 -7.27E-09 -7.68E-09 1.34E-08 -3.92E-09 -2.60E-10 -2.12E-09 -3.22E-09 Dose (krad(Si)) 50 100 5.17E-09 3.09E-09 -1.05E-09 -1.45E-09 1.18E-08 1.12E-08 -2.91E-09 1.58E-09 -4.42E-09 -4.24E-09 -8.33E-09 -8.24E-09 -5.44E-09 -5.42E-09 1.44E-08 1.53E-08 -5.31E-09 -3.58E-09 -2.20E-10 6.30E-10 -2.14E-09 -2.07E-09 -3.20E-09 -3.07E-09 200 4.37E-09 4.20E-10 1.30E-08 2.85E-09 -3.09E-09 -8.49E-09 -4.50E-09 1.66E-08 -2.95E-09 1.52E-09 -1.93E-09 -3.08E-09 2.07E-09 2.10E-09 1.72E-09 2.04E-09 3.52E-09 6.23E-09 6.91E-09 6.72E-09 5.85E-09 6.02E-09 1.91E-08 2.10E-08 2.02E-08 1.81E-08 2.00E-08 -1.50E-08 -1.68E-08 -1.67E-08 -1.40E-08 -1.30E-08 5.92E-10 8.27E-09 2.33E-08 -2.21E-08 -7.00E-08 PASS 7.00E-08 PASS -1.14E-09 8.67E-09 2.26E-08 -2.49E-08 -1.00E-07 PASS 1.00E-07 PASS -9.80E-10 9.08E-09 2.39E-08 -2.59E-08 -1.00E-07 PASS 1.00E-07 PASS An ISO 9001:2008 and DSCC Certified Company 61 -2.56E-10 9.29E-09 2.52E-08 -2.57E-08 -1.00E-07 PASS 1.00E-07 PASS 4.30E-10 9.71E-09 2.70E-08 -2.62E-08 -1.00E-07 PASS 1.00E-07 PASS Input Offset Current2 4 (A) @ VS=+/-15V, VCM=15V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.26. Plot of Input Offset Current2 4 (A) @ VS=+/-15V, VCM=15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 62 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.26. Raw data for Input Offset Current2 4 (A) @ VS=+/-15V, VCM=15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current2 4 (A) @ VS=+/-15V, VCM=15V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 6.07E-09 -5.86E-09 -1.40E-08 1.04E-08 2.77E-09 9.30E-10 -1.30E-09 -9.39E-09 6.22E-09 -1.30E-09 -7.00E-11 4.81E-09 Total 20 5.37E-09 -7.05E-09 -1.35E-08 1.01E-08 2.70E-09 6.00E-11 -2.38E-09 -8.55E-09 7.39E-09 -1.23E-09 -2.50E-10 5.00E-09 Dose (krad(Si)) 50 100 2.34E-09 7.20E-10 -7.78E-09 -8.38E-09 -1.53E-08 -1.69E-08 8.42E-09 1.01E-08 -8.90E-10 -3.30E-09 -1.32E-09 -2.06E-09 -2.72E-09 -3.82E-09 -8.61E-09 -8.60E-09 7.27E-09 5.38E-09 -2.07E-09 -1.58E-09 -1.80E-10 -2.10E-10 5.02E-09 4.90E-09 200 2.24E-09 -6.08E-09 -1.60E-08 8.65E-09 -1.43E-09 -8.40E-10 -4.80E-09 -8.80E-09 7.97E-09 -2.65E-09 -2.10E-10 4.91E-09 -1.34E-10 -4.82E-10 -2.65E-09 -3.55E-09 -2.53E-09 9.77E-09 9.60E-09 9.18E-09 1.01E-08 9.27E-09 2.67E-08 2.58E-08 2.25E-08 2.40E-08 2.29E-08 -2.69E-08 -2.68E-08 -2.78E-08 -3.12E-08 -2.79E-08 -9.68E-10 5.62E-09 1.44E-08 -1.64E-08 -7.00E-08 PASS 7.00E-08 PASS -9.42E-10 5.71E-09 1.47E-08 -1.66E-08 -1.00E-07 PASS 1.00E-07 PASS -1.49E-09 5.69E-09 1.41E-08 -1.71E-08 -1.00E-07 PASS 1.00E-07 PASS An ISO 9001:2008 and DSCC Certified Company 63 -2.14E-09 5.04E-09 1.17E-08 -1.59E-08 -1.00E-07 PASS 1.00E-07 PASS -1.82E-09 6.23E-09 1.52E-08 -1.89E-08 -1.00E-07 PASS 1.00E-07 PASS +Input Bias Current BIAS2 1 (A) @ VS=+/-15V, VCM=15V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-06 1.00E-06 5.00E-07 0.00E+00 -5.00E-07 -1.00E-06 -1.50E-06 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.27. Plot of +Input Bias Current BIAS2 1 (A) @ VS=+/-15V, VCM=15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 64 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.27. Raw data for +Input Bias Current BIAS2 1 (A) @ VS=+/-15V, VCM=15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) +Input Bias Current BIAS2 1 (A) @ VS=+/-15V, VCM=15V Device 0 20 50 100 200 519 2.83E-07 3.19E-07 3.59E-07 4.11E-07 4.83E-07 520 3.09E-07 3.44E-07 3.90E-07 4.43E-07 5.19E-07 521 2.93E-07 3.40E-07 3.84E-07 4.36E-07 5.07E-07 522 2.91E-07 3.31E-07 3.73E-07 4.18E-07 4.98E-07 524 2.92E-07 3.26E-07 3.65E-07 4.20E-07 4.98E-07 536 2.81E-07 3.17E-07 3.62E-07 4.18E-07 4.99E-07 537 2.81E-07 3.16E-07 3.58E-07 4.11E-07 4.86E-07 538 2.72E-07 3.14E-07 3.57E-07 4.14E-07 4.87E-07 539 2.75E-07 3.15E-07 3.58E-07 4.12E-07 4.83E-07 542 2.94E-07 3.33E-07 3.80E-07 4.43E-07 5.20E-07 543 2.86E-07 2.88E-07 2.88E-07 2.88E-07 2.87E-07 544 3.15E-07 3.16E-07 3.16E-07 3.16E-07 3.15E-07 Biased Statistics Average Biased 2.94E-07 3.32E-07 3.74E-07 4.26E-07 5.01E-07 Std Dev Biased 9.15E-09 1.01E-08 1.26E-08 1.33E-08 1.34E-08 Ps90%/90% (+KTL) Biased 3.19E-07 3.60E-07 4.09E-07 4.62E-07 5.38E-07 Ps90%/90% (-KTL) Biased 2.68E-07 3.04E-07 3.39E-07 3.89E-07 4.65E-07 Un-Biased Statistics Average Un-Biased 2.80E-07 3.19E-07 3.63E-07 4.20E-07 4.95E-07 Std Dev Un-Biased 8.69E-09 7.92E-09 9.45E-09 1.35E-08 1.51E-08 Ps90%/90% (+KTL) Un-Biased 3.04E-07 3.41E-07 3.89E-07 4.57E-07 5.36E-07 Ps90%/90% (-KTL) Un-Biased 2.57E-07 2.97E-07 3.37E-07 3.83E-07 4.54E-07 Specification MIN -7.15E-07 -8.15E-07 -8.65E-07 -9.15E-07 -9.65E-07 Status PASS PASS PASS PASS PASS Specification MAX 7.15E-07 8.15E-07 8.65E-07 9.15E-07 9.65E-07 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 65 +Input Bias Current BIAS2 2 (A) @ VS=+/-15V, VCM=15V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-06 1.00E-06 5.00E-07 0.00E+00 -5.00E-07 -1.00E-06 -1.50E-06 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.28. Plot of +Input Bias Current BIAS2 2 (A) @ VS=+/-15V, VCM=15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 66 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.28. Raw data for +Input Bias Current BIAS2 2 (A) @ VS=+/-15V, VCM=15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) +Input Bias Current BIAS2 2 (A) @ VS=+/-15V, VCM=15V Device 0 20 50 100 200 519 3.01E-07 3.39E-07 3.81E-07 4.34E-07 5.05E-07 520 2.90E-07 3.27E-07 3.72E-07 4.22E-07 4.98E-07 521 3.24E-07 3.60E-07 4.09E-07 4.65E-07 5.39E-07 522 2.99E-07 3.36E-07 3.78E-07 4.24E-07 5.08E-07 524 2.76E-07 3.07E-07 3.43E-07 3.90E-07 4.60E-07 536 2.91E-07 3.29E-07 3.75E-07 4.33E-07 5.14E-07 537 2.94E-07 3.31E-07 3.76E-07 4.33E-07 5.08E-07 538 2.87E-07 3.25E-07 3.67E-07 4.21E-07 4.87E-07 539 3.15E-07 3.53E-07 4.05E-07 4.63E-07 5.37E-07 542 2.93E-07 3.31E-07 3.79E-07 4.39E-07 5.13E-07 543 2.46E-07 2.47E-07 2.47E-07 2.47E-07 2.46E-07 544 3.04E-07 3.05E-07 3.05E-07 3.04E-07 3.04E-07 Biased Statistics Average Biased 2.98E-07 3.34E-07 3.76E-07 4.27E-07 5.02E-07 Std Dev Biased 1.78E-08 1.92E-08 2.35E-08 2.68E-08 2.82E-08 Ps90%/90% (+KTL) Biased 3.47E-07 3.86E-07 4.41E-07 5.01E-07 5.79E-07 Ps90%/90% (-KTL) Biased 2.49E-07 2.81E-07 3.12E-07 3.54E-07 4.25E-07 Un-Biased Statistics Average Un-Biased 2.96E-07 3.34E-07 3.80E-07 4.38E-07 5.12E-07 Std Dev Un-Biased 1.12E-08 1.11E-08 1.46E-08 1.56E-08 1.76E-08 Ps90%/90% (+KTL) Un-Biased 3.27E-07 3.64E-07 4.20E-07 4.81E-07 5.60E-07 Ps90%/90% (-KTL) Un-Biased 2.65E-07 3.03E-07 3.40E-07 3.95E-07 4.64E-07 Specification MIN -7.15E-07 -8.15E-07 -8.65E-07 -9.15E-07 -9.65E-07 Status PASS PASS PASS PASS PASS Specification MAX 7.15E-07 8.15E-07 8.65E-07 9.15E-07 9.65E-07 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 67 +Input Bias Current BIAS2 3 (A) @ VS=+/-15V, VCM=15V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-06 1.00E-06 5.00E-07 0.00E+00 -5.00E-07 -1.00E-06 -1.50E-06 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.29. Plot of +Input Bias Current BIAS2 3 (A) @ VS=+/-15V, VCM=15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 68 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.29. Raw data for +Input Bias Current BIAS2 3 (A) @ VS=+/-15V, VCM=15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) +Input Bias Current BIAS2 3 (A) @ VS=+/-15V, VCM=15V Device 0 20 50 100 200 519 2.88E-07 3.30E-07 3.71E-07 4.24E-07 4.96E-07 520 2.77E-07 3.11E-07 3.53E-07 4.03E-07 4.75E-07 521 3.30E-07 3.65E-07 4.14E-07 4.74E-07 5.52E-07 522 2.91E-07 3.35E-07 3.77E-07 4.23E-07 5.08E-07 524 2.71E-07 3.08E-07 3.41E-07 3.94E-07 4.65E-07 536 2.81E-07 3.18E-07 3.63E-07 4.19E-07 4.99E-07 537 2.86E-07 3.28E-07 3.73E-07 4.29E-07 5.06E-07 538 2.96E-07 3.35E-07 3.80E-07 4.36E-07 5.08E-07 539 3.08E-07 3.40E-07 3.93E-07 4.51E-07 5.25E-07 542 2.87E-07 3.27E-07 3.72E-07 4.36E-07 5.12E-07 543 2.43E-07 2.44E-07 2.44E-07 2.44E-07 2.44E-07 544 2.89E-07 2.89E-07 2.89E-07 2.89E-07 2.88E-07 Biased Statistics Average Biased 2.91E-07 3.30E-07 3.71E-07 4.23E-07 4.99E-07 Std Dev Biased 2.33E-08 2.29E-08 2.79E-08 3.10E-08 3.40E-08 Ps90%/90% (+KTL) Biased 3.55E-07 3.93E-07 4.48E-07 5.08E-07 5.92E-07 Ps90%/90% (-KTL) Biased 2.28E-07 2.67E-07 2.95E-07 3.38E-07 4.06E-07 Un-Biased Statistics Average Un-Biased 2.92E-07 3.29E-07 3.76E-07 4.34E-07 5.10E-07 Std Dev Un-Biased 1.08E-08 8.50E-09 1.11E-08 1.18E-08 9.67E-09 Ps90%/90% (+KTL) Un-Biased 3.21E-07 3.53E-07 4.07E-07 4.66E-07 5.37E-07 Ps90%/90% (-KTL) Un-Biased 2.62E-07 3.06E-07 3.45E-07 4.02E-07 4.84E-07 Specification MIN -7.15E-07 -8.15E-07 -8.65E-07 -9.15E-07 -9.65E-07 Status PASS PASS PASS PASS PASS Specification MAX 7.15E-07 8.15E-07 8.65E-07 9.15E-07 9.65E-07 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 69 +Input Bias Current BIAS2 4 (A) @ VS=+/-15V, VCM=15V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-06 1.00E-06 5.00E-07 0.00E+00 -5.00E-07 -1.00E-06 -1.50E-06 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.30. Plot of +Input Bias Current BIAS2 4 (A) @ VS=+/-15V, VCM=15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 70 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.30. Raw data for +Input Bias Current BIAS2 4 (A) @ VS=+/-15V, VCM=15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) +Input Bias Current BIAS2 4 (A) @ VS=+/-15V, VCM=15V Device 0 20 50 100 200 519 2.85E-07 3.20E-07 3.58E-07 4.10E-07 4.82E-07 520 2.95E-07 3.31E-07 3.76E-07 4.27E-07 5.06E-07 521 2.93E-07 3.29E-07 3.71E-07 4.22E-07 4.93E-07 522 3.00E-07 3.38E-07 3.78E-07 4.22E-07 5.01E-07 524 3.05E-07 3.40E-07 3.78E-07 4.32E-07 5.08E-07 536 2.74E-07 3.14E-07 3.56E-07 4.13E-07 4.94E-07 537 2.78E-07 3.18E-07 3.59E-07 4.09E-07 4.82E-07 538 2.78E-07 3.17E-07 3.60E-07 4.16E-07 4.89E-07 539 2.81E-07 3.16E-07 3.61E-07 4.15E-07 4.84E-07 542 2.90E-07 3.28E-07 3.76E-07 4.32E-07 5.14E-07 543 2.90E-07 2.91E-07 2.91E-07 2.91E-07 2.91E-07 544 3.25E-07 3.26E-07 3.26E-07 3.26E-07 3.25E-07 Biased Statistics Average Biased 2.96E-07 3.32E-07 3.72E-07 4.23E-07 4.98E-07 Std Dev Biased 7.73E-09 8.01E-09 8.29E-09 8.24E-09 1.08E-08 Ps90%/90% (+KTL) Biased 3.17E-07 3.54E-07 3.95E-07 4.45E-07 5.27E-07 Ps90%/90% (-KTL) Biased 2.74E-07 3.10E-07 3.49E-07 4.00E-07 4.68E-07 Un-Biased Statistics Average Un-Biased 2.80E-07 3.19E-07 3.62E-07 4.17E-07 4.92E-07 Std Dev Un-Biased 6.12E-09 5.53E-09 7.74E-09 9.04E-09 1.28E-08 Ps90%/90% (+KTL) Un-Biased 2.97E-07 3.34E-07 3.84E-07 4.42E-07 5.27E-07 Ps90%/90% (-KTL) Un-Biased 2.63E-07 3.04E-07 3.41E-07 3.92E-07 4.57E-07 Specification MIN -7.15E-07 -8.15E-07 -8.65E-07 -9.15E-07 -9.65E-07 Status PASS PASS PASS PASS PASS Specification MAX 7.15E-07 8.15E-07 8.65E-07 9.15E-07 9.65E-07 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 71 -Input Bias Current BIAS2 1 (A) @ VS=+/-15V, VCM=15V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-06 1.00E-06 5.00E-07 0.00E+00 -5.00E-07 -1.00E-06 -1.50E-06 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.31. Plot of -Input Bias Current BIAS2 1 (A) @ VS=+/-15V, VCM=15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 72 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.31. Raw data for -Input Bias Current BIAS2 1 (A) @ VS=+/-15V, VCM=15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) -Input Bias Current BIAS2 1 (A) @ VS=+/-15V, VCM=15V Device 0 20 50 100 200 519 2.78E-07 3.16E-07 3.55E-07 4.06E-07 4.79E-07 520 3.06E-07 3.42E-07 3.86E-07 4.42E-07 5.18E-07 521 2.92E-07 3.39E-07 3.81E-07 4.34E-07 5.03E-07 522 2.85E-07 3.26E-07 3.68E-07 4.11E-07 4.92E-07 524 2.93E-07 3.27E-07 3.67E-07 4.25E-07 5.01E-07 536 2.81E-07 3.18E-07 3.62E-07 4.18E-07 4.99E-07 537 2.82E-07 3.17E-07 3.57E-07 4.10E-07 4.84E-07 538 2.66E-07 3.10E-07 3.49E-07 4.07E-07 4.79E-07 539 2.80E-07 3.16E-07 3.60E-07 4.15E-07 4.87E-07 542 2.91E-07 3.29E-07 3.77E-07 4.37E-07 5.18E-07 543 2.87E-07 2.88E-07 2.88E-07 2.88E-07 2.87E-07 544 3.15E-07 3.15E-07 3.16E-07 3.15E-07 3.14E-07 Biased Statistics Average Biased 2.91E-07 3.30E-07 3.72E-07 4.24E-07 4.99E-07 Std Dev Biased 1.03E-08 1.04E-08 1.23E-08 1.50E-08 1.42E-08 Ps90%/90% (+KTL) Biased 3.19E-07 3.59E-07 4.05E-07 4.65E-07 5.37E-07 Ps90%/90% (-KTL) Biased 2.63E-07 3.02E-07 3.38E-07 3.82E-07 4.60E-07 Un-Biased Statistics Average Un-Biased 2.80E-07 3.18E-07 3.61E-07 4.18E-07 4.93E-07 Std Dev Un-Biased 9.18E-09 7.13E-09 1.03E-08 1.17E-08 1.56E-08 Ps90%/90% (+KTL) Un-Biased 3.05E-07 3.37E-07 3.89E-07 4.50E-07 5.36E-07 Ps90%/90% (-KTL) Un-Biased 2.55E-07 2.98E-07 3.33E-07 3.85E-07 4.50E-07 Specification MIN -7.15E-07 -8.15E-07 -8.65E-07 -9.15E-07 -9.65E-07 Status PASS PASS PASS PASS PASS Specification MAX 7.15E-07 8.15E-07 8.65E-07 9.15E-07 9.65E-07 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 73 -Input Bias Current BIAS2 2 (A) @ VS=+/-15V, VCM=15V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-06 1.00E-06 5.00E-07 0.00E+00 -5.00E-07 -1.00E-06 -1.50E-06 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.32. Plot of -Input Bias Current BIAS2 2 (A) @ VS=+/-15V, VCM=15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 74 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.32. Raw data for -Input Bias Current BIAS2 2 (A) @ VS=+/-15V, VCM=15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) -Input Bias Current BIAS2 2 (A) @ VS=+/-15V, VCM=15V Device 0 20 50 100 200 519 2.92E-07 3.30E-07 3.70E-07 4.25E-07 4.97E-07 520 2.91E-07 3.29E-07 3.71E-07 4.25E-07 4.99E-07 521 3.14E-07 3.54E-07 4.01E-07 4.54E-07 5.28E-07 522 2.95E-07 3.33E-07 3.72E-07 4.16E-07 4.99E-07 524 2.69E-07 3.09E-07 3.43E-07 3.90E-07 4.56E-07 536 2.88E-07 3.26E-07 3.70E-07 4.27E-07 5.09E-07 537 2.87E-07 3.25E-07 3.67E-07 4.24E-07 5.00E-07 538 2.76E-07 3.13E-07 3.51E-07 4.03E-07 4.71E-07 539 3.04E-07 3.38E-07 3.89E-07 4.48E-07 5.18E-07 542 2.94E-07 3.32E-07 3.78E-07 4.39E-07 5.13E-07 543 2.45E-07 2.46E-07 2.46E-07 2.46E-07 2.45E-07 544 2.95E-07 2.95E-07 2.95E-07 2.95E-07 2.95E-07 Biased Statistics Average Biased 2.92E-07 3.31E-07 3.71E-07 4.22E-07 4.96E-07 Std Dev Biased 1.59E-08 1.60E-08 2.04E-08 2.30E-08 2.57E-08 Ps90%/90% (+KTL) Biased 3.36E-07 3.75E-07 4.27E-07 4.85E-07 5.66E-07 Ps90%/90% (-KTL) Biased 2.49E-07 2.87E-07 3.15E-07 3.59E-07 4.26E-07 Un-Biased Statistics Average Un-Biased 2.90E-07 3.27E-07 3.71E-07 4.28E-07 5.02E-07 Std Dev Un-Biased 1.00E-08 9.41E-09 1.38E-08 1.72E-08 1.85E-08 Ps90%/90% (+KTL) Un-Biased 3.17E-07 3.53E-07 4.09E-07 4.75E-07 5.53E-07 Ps90%/90% (-KTL) Un-Biased 2.62E-07 3.01E-07 3.33E-07 3.81E-07 4.51E-07 Specification MIN -7.15E-07 -8.15E-07 -8.65E-07 -9.15E-07 -9.65E-07 Status PASS PASS PASS PASS PASS Specification MAX 7.15E-07 8.15E-07 8.65E-07 9.15E-07 9.65E-07 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 75 -Input Bias Current BIAS2 3 (A) @ VS=+/-15V, VCM=15V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-06 1.00E-06 5.00E-07 0.00E+00 -5.00E-07 -1.00E-06 -1.50E-06 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.33. Plot of -Input Bias Current BIAS2 3 (A) @ VS=+/-15V, VCM=15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 76 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.33. Raw data for -Input Bias Current BIAS2 3 (A) @ VS=+/-15V, VCM=15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) -Input Bias Current BIAS2 3 (A) @ VS=+/-15V, VCM=15V Device 0 20 50 100 200 519 2.89E-07 3.25E-07 3.64E-07 4.19E-07 4.89E-07 520 2.77E-07 3.11E-07 3.50E-07 4.01E-07 4.74E-07 521 3.17E-07 3.50E-07 4.02E-07 4.60E-07 5.35E-07 522 2.92E-07 3.38E-07 3.76E-07 4.21E-07 5.02E-07 524 2.71E-07 3.10E-07 3.45E-07 3.96E-07 4.68E-07 536 2.87E-07 3.25E-07 3.68E-07 4.25E-07 5.06E-07 537 2.91E-07 3.35E-07 3.78E-07 4.33E-07 5.08E-07 538 2.83E-07 3.22E-07 3.64E-07 4.19E-07 4.86E-07 539 3.11E-07 3.43E-07 3.94E-07 4.52E-07 5.26E-07 542 2.83E-07 3.27E-07 3.72E-07 4.33E-07 5.09E-07 543 2.46E-07 2.46E-07 2.46E-07 2.46E-07 2.45E-07 544 2.91E-07 2.92E-07 2.92E-07 2.92E-07 2.91E-07 Biased Statistics Average Biased 2.89E-07 3.27E-07 3.67E-07 4.19E-07 4.93E-07 Std Dev Biased 1.79E-08 1.73E-08 2.28E-08 2.52E-08 2.68E-08 Ps90%/90% (+KTL) Biased 3.38E-07 3.74E-07 4.30E-07 4.88E-07 5.67E-07 Ps90%/90% (-KTL) Biased 2.40E-07 2.79E-07 3.05E-07 3.50E-07 4.20E-07 Un-Biased Statistics Average Un-Biased 2.91E-07 3.30E-07 3.75E-07 4.32E-07 5.07E-07 Std Dev Un-Biased 1.18E-08 8.49E-09 1.20E-08 1.23E-08 1.43E-08 Ps90%/90% (+KTL) Un-Biased 3.23E-07 3.53E-07 4.08E-07 4.66E-07 5.46E-07 Ps90%/90% (-KTL) Un-Biased 2.58E-07 3.07E-07 3.42E-07 3.98E-07 4.68E-07 Specification MIN -7.15E-07 -8.15E-07 -8.65E-07 -9.15E-07 -9.65E-07 Status PASS PASS PASS PASS PASS Specification MAX 7.15E-07 8.15E-07 8.65E-07 9.15E-07 9.65E-07 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 77 -Input Bias Current BIAS2 4 (A) @ VS=+/-15V, VCM=15V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-06 1.00E-06 5.00E-07 0.00E+00 -5.00E-07 -1.00E-06 -1.50E-06 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.34. Plot of -Input Bias Current BIAS2 4 (A) @ VS=+/-15V, VCM=15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 78 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.34. Raw data for -Input Bias Current BIAS2 4 (A) @ VS=+/-15V, VCM=15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) -Input Bias Current BIAS2 4 (A) @ VS=+/-15V, VCM=15V Device 0 20 50 100 200 519 2.79E-07 3.15E-07 3.54E-07 4.06E-07 4.76E-07 520 3.01E-07 3.37E-07 3.77E-07 4.33E-07 5.07E-07 521 3.06E-07 3.35E-07 3.82E-07 4.36E-07 5.06E-07 522 2.90E-07 3.28E-07 3.66E-07 4.12E-07 4.90E-07 524 3.03E-07 3.37E-07 3.76E-07 4.32E-07 5.09E-07 536 2.73E-07 3.14E-07 3.54E-07 4.13E-07 4.91E-07 537 2.79E-07 3.19E-07 3.57E-07 4.09E-07 4.84E-07 538 2.88E-07 3.25E-07 3.67E-07 4.22E-07 4.94E-07 539 2.74E-07 3.09E-07 3.48E-07 4.04E-07 4.73E-07 542 2.92E-07 3.29E-07 3.75E-07 4.34E-07 5.11E-07 543 2.90E-07 2.91E-07 2.92E-07 2.91E-07 2.91E-07 544 3.20E-07 3.21E-07 3.21E-07 3.20E-07 3.20E-07 Biased Statistics Average Biased 2.96E-07 3.30E-07 3.71E-07 4.24E-07 4.98E-07 Std Dev Biased 1.12E-08 9.65E-09 1.12E-08 1.38E-08 1.42E-08 Ps90%/90% (+KTL) Biased 3.26E-07 3.57E-07 4.02E-07 4.61E-07 5.37E-07 Ps90%/90% (-KTL) Biased 2.65E-07 3.04E-07 3.41E-07 3.86E-07 4.59E-07 Un-Biased Statistics Average Un-Biased 2.81E-07 3.19E-07 3.60E-07 4.17E-07 4.90E-07 Std Dev Un-Biased 8.25E-09 8.34E-09 1.05E-08 1.19E-08 1.41E-08 Ps90%/90% (+KTL) Un-Biased 3.04E-07 3.42E-07 3.89E-07 4.49E-07 5.29E-07 Ps90%/90% (-KTL) Un-Biased 2.58E-07 2.96E-07 3.31E-07 3.84E-07 4.52E-07 Specification MIN -7.15E-07 -8.15E-07 -8.65E-07 -9.15E-07 -9.65E-07 Status PASS PASS PASS PASS PASS Specification MAX 7.15E-07 8.15E-07 8.65E-07 9.15E-07 9.65E-07 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 79 Input Offset Voltage3 1 (V) @ VS=+/-15V, VCM=-15V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.35. Plot of Input Offset Voltage3 1 (V) @ VS=+/-15V, VCM=-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 80 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.35. Raw data for Input Offset Voltage3 1 (V) @ VS=+/-15V, VCM=-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage3 1 (V) @ VS=+/-15V, VCM=-15V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 1.18E-05 2.27E-04 -1.17E-04 -1.40E-04 -8.41E-05 -1.14E-04 -2.01E-04 -4.76E-05 -2.61E-04 5.67E-05 -3.15E-04 -2.04E-04 Total 20 -1.06E-05 1.96E-04 -1.29E-04 -1.66E-04 -1.03E-04 -1.32E-04 -2.14E-04 -4.45E-05 -2.63E-04 4.12E-05 -3.17E-04 -2.04E-04 Dose (krad(Si)) 50 100 5.40E-07 -1.07E-05 1.96E-04 1.87E-04 -1.35E-04 -1.41E-04 -1.61E-04 -1.69E-04 -9.97E-05 -9.10E-05 -1.38E-04 -1.53E-04 -2.21E-04 -2.33E-04 -5.86E-05 -7.26E-05 -2.71E-04 -2.80E-04 2.95E-05 1.77E-05 -3.18E-04 -3.17E-04 -2.05E-04 -2.04E-04 200 -1.11E-05 1.73E-04 -1.50E-04 -1.76E-04 -9.22E-05 -1.77E-04 -2.58E-04 -9.27E-05 -3.06E-04 4.20E-07 -3.17E-04 -2.04E-04 -2.05E-05 -4.24E-05 -3.98E-05 -4.52E-05 -5.12E-05 1.50E-04 1.45E-04 1.45E-04 1.43E-04 1.40E-04 3.91E-04 3.55E-04 3.58E-04 3.47E-04 3.33E-04 -4.32E-04 -4.40E-04 -4.38E-04 -4.37E-04 -4.36E-04 -1.14E-04 1.25E-04 2.30E-04 -4.57E-04 -8.00E-04 PASS 8.00E-04 PASS -1.22E-04 1.24E-04 2.16E-04 -4.61E-04 -9.50E-04 PASS 9.50E-04 PASS -1.32E-04 1.21E-04 2.00E-04 -4.64E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 81 -1.44E-04 1.20E-04 1.85E-04 -4.73E-04 -9.50E-04 PASS 9.50E-04 PASS -1.67E-04 1.24E-04 1.73E-04 -5.06E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Voltage3 2 (V) @ VS=+/-15V, VCM=-15V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.36. Plot of Input Offset Voltage3 2 (V) @ VS=+/-15V, VCM=-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 82 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.36. Raw data for Input Offset Voltage3 2 (V) @ VS=+/-15V, VCM=-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage3 2 (V) @ VS=+/-15V, VCM=-15V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -2.59E-04 1.24E-04 -3.49E-04 -3.41E-04 1.29E-04 4.67E-05 -3.81E-04 -1.41E-04 -1.75E-04 -2.48E-04 -9.06E-05 -6.15E-05 Total 20 -3.00E-04 1.15E-04 -3.86E-04 -3.59E-04 9.87E-05 2.83E-05 -4.08E-04 -1.51E-04 -1.83E-04 -2.71E-04 -9.59E-05 -6.04E-05 Dose (krad(Si)) 50 100 -2.91E-04 -2.95E-04 1.15E-04 1.13E-04 -3.88E-04 -3.74E-04 -3.49E-04 -3.46E-04 8.75E-05 9.22E-05 2.00E-05 1.04E-05 -4.17E-04 -4.27E-04 -1.49E-04 -1.46E-04 -1.91E-04 -2.03E-04 -2.76E-04 -2.85E-04 -9.70E-05 -9.60E-05 -6.18E-05 -6.02E-05 200 -3.02E-04 1.10E-04 -3.72E-04 -3.39E-04 9.28E-05 -1.23E-05 -4.42E-04 -1.64E-04 -2.16E-04 -3.00E-04 -9.60E-05 -5.95E-05 -1.39E-04 -1.66E-04 -1.65E-04 -1.62E-04 -1.62E-04 2.45E-04 2.51E-04 2.46E-04 2.43E-04 2.42E-04 5.33E-04 5.23E-04 5.08E-04 5.05E-04 5.01E-04 -8.12E-04 -8.55E-04 -8.39E-04 -8.29E-04 -8.25E-04 -1.80E-04 1.57E-04 2.50E-04 -6.09E-04 -8.00E-04 PASS 8.00E-04 PASS -1.97E-04 1.60E-04 2.43E-04 -6.37E-04 -9.50E-04 PASS 9.50E-04 PASS -2.03E-04 1.61E-04 2.40E-04 -6.45E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 83 -2.10E-04 1.62E-04 2.35E-04 -6.56E-04 -9.50E-04 PASS 9.50E-04 PASS -2.27E-04 1.59E-04 2.10E-04 -6.64E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Voltage3 3 (V) @ VS=+/-15V, VCM=-15V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.37. Plot of Input Offset Voltage3 3 (V) @ VS=+/-15V, VCM=-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 84 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.37. Raw data for Input Offset Voltage3 3 (V) @ VS=+/-15V, VCM=-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage3 3 (V) @ VS=+/-15V, VCM=-15V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -4.89E-05 -8.57E-05 -2.15E-04 1.85E-05 1.74E-06 -5.25E-04 1.30E-05 -2.13E-04 -1.09E-04 9.84E-05 5.38E-05 -6.29E-05 Total 20 -4.39E-05 -1.19E-04 -2.43E-04 4.27E-06 -2.78E-05 -5.41E-04 -2.00E-05 -2.29E-04 -8.71E-05 8.05E-05 4.89E-05 -6.49E-05 Dose (krad(Si)) 50 100 -3.95E-05 -4.15E-05 -1.24E-04 -1.29E-04 -2.40E-04 -2.42E-04 4.04E-06 3.00E-07 -5.00E-05 -5.54E-05 -5.47E-04 -5.54E-04 -2.54E-05 -3.99E-05 -2.38E-04 -2.56E-04 -9.75E-05 -1.16E-04 6.86E-05 4.73E-05 4.90E-05 4.97E-05 -6.45E-05 -6.49E-05 200 -3.83E-05 -1.35E-04 -2.44E-04 -6.70E-06 -6.82E-05 -5.86E-04 -5.95E-05 -2.80E-04 -1.34E-04 2.34E-05 5.08E-05 -6.25E-05 -6.59E-05 -8.58E-05 -8.99E-05 -9.35E-05 -9.84E-05 9.32E-05 9.87E-05 9.58E-05 9.53E-05 9.40E-05 1.90E-04 1.85E-04 1.73E-04 1.68E-04 1.59E-04 -3.22E-04 -3.57E-04 -3.53E-04 -3.55E-04 -3.56E-04 -1.47E-04 2.42E-04 5.17E-04 -8.11E-04 -8.00E-04 PASS 8.00E-04 PASS -1.59E-04 2.41E-04 5.02E-04 -8.20E-04 -9.50E-04 PASS 9.50E-04 PASS -1.68E-04 2.40E-04 4.89E-04 -8.24E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 85 -1.84E-04 2.35E-04 4.61E-04 -8.28E-04 -9.50E-04 PASS 9.50E-04 PASS -2.07E-04 2.39E-04 4.49E-04 -8.64E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Voltage3 4 (V) @ VS=+/-15V, VCM=-15V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.38. Plot of Input Offset Voltage3 4 (V) @ VS=+/-15V, VCM=-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 86 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.38. Raw data for Input Offset Voltage3 4 (V) @ VS=+/-15V, VCM=-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage3 4 (V) @ VS=+/-15V, VCM=-15V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -1.38E-04 -2.34E-05 1.24E-04 -8.54E-05 1.04E-04 -1.15E-04 -1.70E-04 1.76E-04 -1.74E-04 -8.07E-05 4.14E-04 2.08E-05 Total 20 -1.61E-04 -7.02E-05 8.50E-05 -9.93E-05 7.86E-05 -1.15E-04 -1.73E-04 1.69E-04 -1.76E-04 -9.48E-05 4.05E-04 1.99E-05 Dose (krad(Si)) 50 100 -1.55E-04 -1.55E-04 -6.85E-05 -7.53E-05 8.78E-05 8.51E-05 -9.01E-05 -9.25E-05 7.74E-05 8.82E-05 -1.19E-04 -1.28E-04 -1.78E-04 -1.85E-04 1.64E-04 1.54E-04 -1.85E-04 -1.97E-04 -1.05E-04 -1.15E-04 4.03E-04 4.04E-04 1.91E-05 2.01E-05 200 -1.57E-04 -7.47E-05 8.66E-05 -9.18E-05 9.01E-05 -1.47E-04 -2.00E-04 1.38E-04 -2.18E-04 -1.26E-04 4.08E-04 2.19E-05 -3.67E-06 -3.33E-05 -2.96E-05 -3.00E-05 -2.94E-05 1.15E-04 1.10E-04 1.07E-04 1.11E-04 1.12E-04 3.13E-04 2.69E-04 2.65E-04 2.73E-04 2.77E-04 -3.20E-04 -3.35E-04 -3.24E-04 -3.33E-04 -3.36E-04 -7.27E-05 1.44E-04 3.23E-04 -4.68E-04 -8.00E-04 PASS 8.00E-04 PASS -7.81E-05 1.43E-04 3.13E-04 -4.69E-04 -9.50E-04 PASS 9.50E-04 PASS -8.48E-05 1.43E-04 3.08E-04 -4.78E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 87 -9.40E-05 1.43E-04 2.99E-04 -4.87E-04 -9.50E-04 PASS 9.50E-04 PASS -1.11E-04 1.44E-04 2.84E-04 -5.05E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Current3 1 (A) @ VS=+/-15V, VCM=-15V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.39. Plot of Input Offset Current3 1 (A) @ VS=+/-15V, VCM=-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 88 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.39. Raw data for Input Offset Current3 1 (A) @ VS=+/-15V, VCM=-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current3 1 (A) @ VS=+/-15V, VCM=-15V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 4.25E-09 2.13E-09 -1.01E-09 -2.83E-09 -1.50E-10 8.90E-10 3.30E-10 -2.92E-09 -6.85E-09 -6.90E-10 -1.12E-09 -6.80E-09 Total 20 4.59E-09 1.08E-09 -1.42E-09 -3.37E-09 -5.20E-10 7.60E-10 1.50E-10 -2.82E-09 -6.84E-09 -1.24E-09 -1.09E-09 -6.86E-09 Dose (krad(Si)) 50 100 4.65E-09 5.61E-09 1.46E-09 1.53E-09 -1.46E-09 -9.90E-10 -1.99E-09 -2.90E-09 -7.10E-10 -1.80E-10 1.64E-09 3.00E-09 7.10E-10 1.30E-10 -3.68E-09 -3.09E-09 -7.82E-09 -7.69E-09 -1.66E-09 -1.87E-09 -1.09E-09 -1.08E-09 -6.86E-09 -6.85E-09 200 6.15E-09 -1.04E-09 -1.19E-09 -4.34E-09 -3.50E-10 2.85E-09 -1.70E-10 -3.64E-09 -1.00E-08 -3.18E-09 -1.07E-09 -6.83E-09 4.78E-10 7.20E-11 3.90E-10 6.14E-10 -1.54E-10 2.76E-09 2.99E-09 2.72E-09 3.22E-09 3.85E-09 8.05E-09 8.28E-09 7.85E-09 9.43E-09 1.04E-08 -7.09E-09 -8.14E-09 -7.07E-09 -8.20E-09 -1.07E-08 -1.85E-09 3.15E-09 6.80E-09 -1.05E-08 -7.00E-08 PASS 7.00E-08 PASS -2.00E-09 3.04E-09 6.33E-09 -1.03E-08 -1.00E-07 PASS 1.00E-07 PASS -2.16E-09 3.78E-09 8.21E-09 -1.25E-08 -1.00E-07 PASS 1.00E-07 PASS An ISO 9001:2008 and DSCC Certified Company 89 -1.90E-09 3.97E-09 8.98E-09 -1.28E-08 -1.00E-07 PASS 1.00E-07 PASS -2.83E-09 4.79E-09 1.03E-08 -1.60E-08 -1.00E-07 PASS 1.00E-07 PASS Input Offset Current3 2 (A) @ VS=+/-15V, VCM=-15V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.40. Plot of Input Offset Current3 2 (A) @ VS=+/-15V, VCM=-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 90 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.40. Raw data for Input Offset Current3 2 (A) @ VS=+/-15V, VCM=-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current3 2 (A) @ VS=+/-15V, VCM=-15V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 3.90E-10 -2.14E-09 2.49E-09 -2.19E-09 -9.00E-11 4.57E-09 -4.77E-09 -9.20E-10 2.24E-09 -6.33E-09 -2.03E-09 6.89E-09 Total 20 -3.40E-10 -2.45E-09 1.66E-09 -2.27E-09 2.00E-11 4.89E-09 -5.04E-09 -5.70E-10 2.33E-09 -6.20E-09 -2.01E-09 6.97E-09 Dose (krad(Si)) 50 100 -7.80E-10 -1.00E-09 -2.79E-09 -2.55E-09 2.48E-09 1.68E-09 -3.23E-09 -1.86E-09 -2.80E-10 1.40E-10 4.50E-09 5.42E-09 -5.06E-09 -6.26E-09 -3.90E-10 -8.70E-10 2.05E-09 2.58E-09 -6.17E-09 -5.13E-09 -2.03E-09 -2.02E-09 6.98E-09 6.98E-09 200 -1.04E-09 -3.64E-09 9.00E-10 -1.84E-09 1.02E-09 3.77E-09 -4.78E-09 -1.92E-09 2.55E-09 -5.87E-09 -2.00E-09 6.88E-09 -3.08E-10 -6.76E-10 -9.20E-10 -7.18E-10 -9.20E-10 1.95E-09 1.71E-09 2.28E-09 1.68E-09 1.96E-09 5.05E-09 4.02E-09 5.34E-09 3.88E-09 4.45E-09 -5.66E-09 -5.37E-09 -7.18E-09 -5.31E-09 -6.29E-09 -1.04E-09 4.59E-09 1.15E-08 -1.36E-08 -7.00E-08 PASS 7.00E-08 PASS -9.18E-10 4.72E-09 1.20E-08 -1.39E-08 -1.00E-07 PASS 1.00E-07 PASS -1.01E-09 4.56E-09 1.15E-08 -1.35E-08 -1.00E-07 PASS 1.00E-07 PASS An ISO 9001:2008 and DSCC Certified Company 91 -8.52E-10 4.97E-09 1.28E-08 -1.45E-08 -1.00E-07 PASS 1.00E-07 PASS -1.25E-09 4.30E-09 1.05E-08 -1.30E-08 -1.00E-07 PASS 1.00E-07 PASS Input Offset Current3 3 (A) @ VS=+/-15V, VCM=-15V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.41. Plot of Input Offset Current3 3 (A) @ VS=+/-15V, VCM=-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 92 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.41. Raw data for Input Offset Current3 3 (A) @ VS=+/-15V, VCM=-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current3 3 (A) @ VS=+/-15V, VCM=-15V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 2.26E-09 -1.62E-09 -1.50E-09 -2.80E-10 -4.12E-09 -3.04E-09 -1.95E-09 5.00E-11 4.05E-09 -3.09E-09 -1.73E-09 -1.49E-09 Total 20 3.24E-09 -1.01E-09 -1.10E-09 6.60E-10 -3.71E-09 -3.34E-09 -2.01E-09 1.60E-10 4.37E-09 -3.55E-09 -1.76E-09 -1.57E-09 Dose (krad(Si)) 50 100 3.07E-09 3.43E-09 -1.51E-09 -1.55E-09 -8.00E-10 -1.48E-09 -1.50E-10 1.41E-09 -4.41E-09 -5.29E-09 -4.11E-09 -2.60E-09 -1.36E-09 -1.47E-09 -1.10E-10 2.60E-10 4.18E-09 4.18E-09 -3.74E-09 -4.71E-09 -1.76E-09 -1.74E-09 -1.59E-09 -1.60E-09 200 3.59E-09 -1.91E-09 -1.15E-09 3.43E-09 -5.24E-09 -3.40E-09 -4.50E-10 4.60E-10 3.73E-09 -6.99E-09 -1.74E-09 -1.56E-09 -1.05E-09 -3.84E-10 -7.60E-10 -6.96E-10 -2.56E-10 2.32E-09 2.56E-09 2.69E-09 3.31E-09 3.77E-09 5.31E-09 6.63E-09 6.61E-09 8.39E-09 1.01E-08 -7.41E-09 -7.40E-09 -8.13E-09 -9.78E-09 -1.06E-08 -7.96E-10 2.99E-09 7.41E-09 -9.00E-09 -7.00E-08 PASS 7.00E-08 PASS -8.74E-10 3.28E-09 8.13E-09 -9.87E-09 -1.00E-07 PASS 1.00E-07 PASS -1.03E-09 3.35E-09 8.16E-09 -1.02E-08 -1.00E-07 PASS 1.00E-07 PASS An ISO 9001:2008 and DSCC Certified Company 93 -8.68E-10 3.35E-09 8.32E-09 -1.01E-08 -1.00E-07 PASS 1.00E-07 PASS -1.33E-09 4.06E-09 9.80E-09 -1.25E-08 -1.00E-07 PASS 1.00E-07 PASS Input Offset Current3 4 (A) @ VS=+/-15V, VCM=-15V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.42. Plot of Input Offset Current3 4 (A) @ VS=+/-15V, VCM=-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 94 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.42. Raw data for Input Offset Current3 4 (A) @ VS=+/-15V, VCM=-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current3 4 (A) @ VS=+/-15V, VCM=-15V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 8.10E-10 0.00E+00 -4.34E-09 -1.36E-09 2.85E-09 -1.66E-09 2.17E-09 1.59E-09 2.00E-09 5.25E-09 -3.03E-09 -4.16E-09 Total 20 9.10E-10 2.40E-10 -4.89E-09 -1.36E-09 3.36E-09 -1.64E-09 2.23E-09 1.01E-09 2.51E-09 5.57E-09 -3.07E-09 -4.23E-09 Dose (krad(Si)) 50 100 1.15E-09 5.50E-10 3.40E-10 -4.80E-10 -3.92E-09 -4.24E-09 -1.17E-09 -1.23E-09 4.68E-09 6.59E-09 -1.00E-09 1.80E-10 2.07E-09 3.05E-09 5.00E-10 1.63E-09 3.10E-09 3.13E-09 5.50E-09 4.53E-09 -3.07E-09 -3.11E-09 -4.18E-09 -4.22E-09 200 -1.60E-10 -5.70E-10 -3.45E-09 -1.04E-09 7.52E-09 1.10E-09 1.80E-09 -3.40E-10 3.06E-09 7.09E-09 -3.08E-09 -4.10E-09 -4.08E-10 -3.48E-10 2.16E-10 2.38E-10 4.60E-10 2.68E-09 3.05E-09 3.16E-09 3.97E-09 4.15E-09 6.93E-09 8.03E-09 8.87E-09 1.11E-08 1.18E-08 -7.74E-09 -8.72E-09 -8.44E-09 -1.07E-08 -1.09E-08 1.87E-09 2.45E-09 8.60E-09 -4.86E-09 -7.00E-08 PASS 7.00E-08 PASS 1.94E-09 2.61E-09 9.10E-09 -5.22E-09 -1.00E-07 PASS 1.00E-07 PASS 2.03E-09 2.49E-09 8.85E-09 -4.78E-09 -1.00E-07 PASS 1.00E-07 PASS An ISO 9001:2008 and DSCC Certified Company 95 2.50E-09 1.66E-09 7.04E-09 -2.03E-09 -1.00E-07 PASS 1.00E-07 PASS 2.54E-09 2.82E-09 1.03E-08 -5.20E-09 -1.00E-07 PASS 1.00E-07 PASS +Input Bias Current BIAS3 1 (A) @ VS=+/-15V, VCM=15V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-06 1.00E-06 5.00E-07 0.00E+00 -5.00E-07 -1.00E-06 -1.50E-06 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.43. Plot of +Input Bias Current BIAS3 1 (A) @ VS=+/-15V, VCM=-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 96 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.43. Raw data for +Input Bias Current BIAS3 1 (A) @ VS=+/-15V, VCM=-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Input Bias Current BIAS3 1 (A) @ VS=+/-15V, VCM=-15V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -2.92E-07 -3.08E-07 -3.11E-07 -3.03E-07 -2.95E-07 -2.85E-07 -2.93E-07 -2.81E-07 -2.85E-07 -3.04E-07 -3.04E-07 -3.40E-07 Total 20 -3.06E-07 -3.23E-07 -3.25E-07 -3.18E-07 -3.10E-07 -2.98E-07 -3.06E-07 -2.94E-07 -2.98E-07 -3.18E-07 -3.07E-07 -3.45E-07 Dose (krad(Si)) 50 100 -3.13E-07 -3.32E-07 -3.37E-07 -3.55E-07 -3.40E-07 -3.59E-07 -3.31E-07 -3.49E-07 -3.24E-07 -3.46E-07 -3.14E-07 -3.36E-07 -3.22E-07 -3.48E-07 -3.11E-07 -3.32E-07 -3.15E-07 -3.37E-07 -3.34E-07 -3.61E-07 -3.07E-07 -3.06E-07 -3.45E-07 -3.45E-07 -3.02E-07 -3.16E-07 -3.29E-07 -3.48E-07 -3.77E-07 8.28E-09 7.99E-09 1.06E-08 1.05E-08 1.23E-08 -2.79E-07 -2.95E-07 -3.00E-07 -3.19E-07 -3.44E-07 -3.24E-07 -3.38E-07 -3.58E-07 -3.77E-07 -4.11E-07 -2.90E-07 9.19E-09 -2.64E-07 -3.15E-07 -7.15E-07 PASS 7.15E-07 PASS -3.03E-07 9.51E-09 -2.77E-07 -3.29E-07 -8.15E-07 PASS 8.15E-07 PASS -3.19E-07 9.33E-09 -2.94E-07 -3.45E-07 -8.65E-07 PASS 8.65E-07 PASS An ISO 9001:2008 and DSCC Certified Company 97 200 -3.59E-07 -3.89E-07 -3.89E-07 -3.76E-07 -3.75E-07 -3.74E-07 -3.81E-07 -3.71E-07 -3.77E-07 -3.97E-07 -3.06E-07 -3.40E-07 -3.43E-07 1.19E-08 -3.10E-07 -3.76E-07 -9.15E-07 PASS 9.15E-07 PASS -3.80E-07 9.91E-09 -3.53E-07 -4.07E-07 -9.65E-07 PASS 9.65E-07 PASS +Input Bias Current BIAS3 2 (A) @ VS=+/-15V, VCM=15V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-06 1.00E-06 5.00E-07 0.00E+00 -5.00E-07 -1.00E-06 -1.50E-06 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.44. Plot of +Input Bias Current BIAS3 2 (A) @ VS=+/-15V, VCM=-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 98 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.44. Raw data for +Input Bias Current BIAS3 2 (A) @ VS=+/-15V, VCM=-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Input Bias Current BIAS3 2 (A) @ VS=+/-15V, VCM=-15V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -3.04E-07 -2.99E-07 -3.50E-07 -3.08E-07 -2.75E-07 -2.87E-07 -2.99E-07 -2.85E-07 -3.10E-07 -3.07E-07 -2.43E-07 -3.06E-07 Total 20 -3.18E-07 -3.11E-07 -3.61E-07 -3.21E-07 -2.88E-07 -2.99E-07 -3.12E-07 -2.97E-07 -3.22E-07 -3.19E-07 -2.44E-07 -3.08E-07 Dose (krad(Si)) 50 100 -3.24E-07 -3.40E-07 -3.24E-07 -3.37E-07 -3.75E-07 -3.88E-07 -3.32E-07 -3.45E-07 -2.97E-07 -3.10E-07 -3.13E-07 -3.32E-07 -3.27E-07 -3.52E-07 -3.10E-07 -3.29E-07 -3.37E-07 -3.62E-07 -3.34E-07 -3.54E-07 -2.45E-07 -2.44E-07 -3.08E-07 -3.07E-07 -3.07E-07 -3.20E-07 -3.30E-07 -3.44E-07 -3.69E-07 2.68E-08 2.64E-08 2.84E-08 2.80E-08 2.87E-08 -2.33E-07 -2.47E-07 -2.53E-07 -2.67E-07 -2.91E-07 -3.81E-07 -3.92E-07 -4.08E-07 -4.21E-07 -4.48E-07 -2.98E-07 1.14E-08 -2.67E-07 -3.29E-07 -7.15E-07 PASS 7.15E-07 PASS -3.10E-07 1.17E-08 -2.78E-07 -3.42E-07 -8.15E-07 PASS 8.15E-07 PASS -3.24E-07 1.20E-08 -2.91E-07 -3.57E-07 -8.65E-07 PASS 8.65E-07 PASS An ISO 9001:2008 and DSCC Certified Company 99 200 -3.63E-07 -3.67E-07 -4.13E-07 -3.70E-07 -3.33E-07 -3.64E-07 -3.77E-07 -3.60E-07 -3.90E-07 -3.90E-07 -2.44E-07 -3.06E-07 -3.46E-07 1.45E-08 -3.06E-07 -3.85E-07 -9.15E-07 PASS 9.15E-07 PASS -3.76E-07 1.40E-08 -3.38E-07 -4.15E-07 -9.65E-07 PASS 9.65E-07 PASS +Input Bias Current BIAS3 3 (A) @ VS=+/-15V, VCM=15V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-06 1.00E-06 5.00E-07 0.00E+00 -5.00E-07 -1.00E-06 -1.50E-06 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.45. Plot of +Input Bias Current BIAS3 3 (A) @ VS=+/-15V, VCM=-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 100 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.45. Raw data for +Input Bias Current BIAS3 3 (A) @ VS=+/-15V, VCM=-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Input Bias Current BIAS3 3 (A) @ VS=+/-15V, VCM=-15V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -3.01E-07 -2.84E-07 -3.53E-07 -3.05E-07 -2.81E-07 -2.88E-07 -2.99E-07 -2.89E-07 -3.07E-07 -3.04E-07 -2.44E-07 -3.07E-07 Total 20 -3.16E-07 -2.97E-07 -3.67E-07 -3.19E-07 -2.95E-07 -3.02E-07 -3.13E-07 -3.02E-07 -3.20E-07 -3.17E-07 -2.45E-07 -3.08E-07 Dose (krad(Si)) 50 100 -3.23E-07 -3.40E-07 -3.11E-07 -3.26E-07 -3.82E-07 -3.97E-07 -3.31E-07 -3.48E-07 -3.06E-07 -3.23E-07 -3.19E-07 -3.40E-07 -3.30E-07 -3.57E-07 -3.17E-07 -3.38E-07 -3.36E-07 -3.61E-07 -3.34E-07 -3.61E-07 -2.45E-07 -2.45E-07 -3.08E-07 -3.08E-07 -3.05E-07 -3.19E-07 -3.31E-07 -3.47E-07 -3.75E-07 2.91E-08 2.92E-08 3.04E-08 3.00E-08 2.83E-08 -2.25E-07 -2.39E-07 -2.47E-07 -2.65E-07 -2.97E-07 -3.84E-07 -3.99E-07 -4.14E-07 -4.29E-07 -4.52E-07 -2.97E-07 8.42E-09 -2.74E-07 -3.21E-07 -7.15E-07 PASS 7.15E-07 PASS -3.11E-07 8.38E-09 -2.88E-07 -3.34E-07 -8.15E-07 PASS 8.15E-07 PASS -3.27E-07 8.77E-09 -3.03E-07 -3.51E-07 -8.65E-07 PASS 8.65E-07 PASS An ISO 9001:2008 and DSCC Certified Company 101 200 -3.67E-07 -3.58E-07 -4.24E-07 -3.73E-07 -3.54E-07 -3.76E-07 -3.92E-07 -3.74E-07 -3.97E-07 -4.00E-07 -2.45E-07 -3.07E-07 -3.51E-07 1.15E-08 -3.20E-07 -3.83E-07 -9.15E-07 PASS 9.15E-07 PASS -3.88E-07 1.19E-08 -3.55E-07 -4.20E-07 -9.65E-07 PASS 9.65E-07 PASS +Input Bias Current BIAS3 4 (A) @ VS=+/-15V, VCM=15V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-06 1.00E-06 5.00E-07 0.00E+00 -5.00E-07 -1.00E-06 -1.50E-06 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.46. Plot of +Input Bias Current BIAS3 4 (A) @ VS=+/-15V, VCM=-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 102 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.46. Raw data for +Input Bias Current BIAS3 4 (A) @ VS=+/-15V, VCM=-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Input Bias Current BIAS3 4 (A) @ VS=+/-15V, VCM=-15V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -2.94E-07 -3.10E-07 -3.11E-07 -3.03E-07 -3.02E-07 -2.83E-07 -2.90E-07 -2.78E-07 -2.81E-07 -3.03E-07 -3.06E-07 -3.44E-07 Total 20 -3.07E-07 -3.22E-07 -3.23E-07 -3.17E-07 -3.15E-07 -2.94E-07 -3.01E-07 -2.90E-07 -2.92E-07 -3.15E-07 -3.09E-07 -3.47E-07 Dose (krad(Si)) 50 100 -3.13E-07 -3.30E-07 -3.34E-07 -3.49E-07 -3.36E-07 -3.53E-07 -3.28E-07 -3.44E-07 -3.26E-07 -3.41E-07 -3.08E-07 -3.26E-07 -3.15E-07 -3.31E-07 -3.03E-07 -3.22E-07 -3.06E-07 -3.24E-07 -3.30E-07 -3.52E-07 -3.09E-07 -3.08E-07 -3.46E-07 -3.46E-07 -3.04E-07 -3.17E-07 -3.27E-07 -3.43E-07 -3.71E-07 7.13E-09 6.59E-09 9.15E-09 8.70E-09 8.53E-09 -2.85E-07 -2.99E-07 -3.02E-07 -3.20E-07 -3.47E-07 -3.24E-07 -3.35E-07 -3.52E-07 -3.67E-07 -3.94E-07 -2.87E-07 1.02E-08 -2.59E-07 -3.15E-07 -7.15E-07 PASS 7.15E-07 PASS -2.99E-07 1.04E-08 -2.70E-07 -3.27E-07 -8.15E-07 PASS 8.15E-07 PASS -3.13E-07 1.09E-08 -2.83E-07 -3.42E-07 -8.65E-07 PASS 8.65E-07 PASS An ISO 9001:2008 and DSCC Certified Company 103 200 -3.57E-07 -3.77E-07 -3.78E-07 -3.70E-07 -3.73E-07 -3.56E-07 -3.65E-07 -3.55E-07 -3.55E-07 -3.87E-07 -3.08E-07 -3.44E-07 -3.31E-07 1.24E-08 -2.97E-07 -3.65E-07 -9.15E-07 PASS 9.15E-07 PASS -3.64E-07 1.36E-08 -3.26E-07 -4.01E-07 -9.65E-07 PASS 9.65E-07 PASS -Input Bias Current BIAS3 1 (A) @ VS=+/-15V, VCM=-15V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-06 1.00E-06 5.00E-07 0.00E+00 -5.00E-07 -1.00E-06 -1.50E-06 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.47. Plot of -Input Bias Current BIAS3 1 (A) @ VS=+/-15V, VCM=-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 104 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.47. Raw data for -Input Bias Current BIAS3 1 (A) @ VS=+/-15V, VCM=-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Input Bias Current BIAS3 1 (A) @ VS=+/-15V, VCM=-15V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -2.96E-07 -3.10E-07 -3.09E-07 -3.00E-07 -2.95E-07 -2.85E-07 -2.93E-07 -2.78E-07 -2.78E-07 -3.03E-07 -3.02E-07 -3.33E-07 Total 20 -3.11E-07 -3.23E-07 -3.23E-07 -3.15E-07 -3.09E-07 -2.98E-07 -3.06E-07 -2.91E-07 -2.91E-07 -3.16E-07 -3.05E-07 -3.34E-07 Dose (krad(Si)) 50 100 -3.18E-07 -3.38E-07 -3.38E-07 -3.55E-07 -3.38E-07 -3.60E-07 -3.29E-07 -3.44E-07 -3.23E-07 -3.45E-07 -3.15E-07 -3.38E-07 -3.22E-07 -3.48E-07 -3.07E-07 -3.28E-07 -3.07E-07 -3.28E-07 -3.32E-07 -3.58E-07 -3.05E-07 -3.05E-07 -3.34E-07 -3.34E-07 -3.02E-07 -3.16E-07 -3.29E-07 -3.48E-07 -3.78E-07 7.32E-09 6.74E-09 8.84E-09 8.99E-09 9.08E-09 -2.82E-07 -2.98E-07 -3.05E-07 -3.24E-07 -3.53E-07 -3.22E-07 -3.35E-07 -3.54E-07 -3.73E-07 -4.03E-07 -2.87E-07 1.08E-08 -2.58E-07 -3.17E-07 -7.15E-07 PASS 7.15E-07 PASS -3.00E-07 1.08E-08 -2.71E-07 -3.30E-07 -8.15E-07 PASS 8.15E-07 PASS -3.17E-07 1.08E-08 -2.87E-07 -3.46E-07 -8.65E-07 PASS 8.65E-07 PASS An ISO 9001:2008 and DSCC Certified Company 105 200 -3.66E-07 -3.87E-07 -3.87E-07 -3.73E-07 -3.76E-07 -3.77E-07 -3.80E-07 -3.66E-07 -3.63E-07 -3.95E-07 -3.05E-07 -3.33E-07 -3.40E-07 1.28E-08 -3.05E-07 -3.75E-07 -9.15E-07 PASS 9.15E-07 PASS -3.76E-07 1.27E-08 -3.41E-07 -4.11E-07 -9.65E-07 PASS 9.65E-07 PASS -Input Bias Current BIAS3 2 (A) @ VS=+/-15V, VCM=-15V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-06 1.00E-06 5.00E-07 0.00E+00 -5.00E-07 -1.00E-06 -1.50E-06 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.48. Plot of -Input Bias Current BIAS3 2 (A) @ VS=+/-15V, VCM=-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 106 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.48. Raw data for -Input Bias Current BIAS3 2 (A) @ VS=+/-15V, VCM=-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Input Bias Current BIAS3 2 (A) @ VS=+/-15V, VCM=-15V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -3.04E-07 -2.97E-07 -3.53E-07 -3.05E-07 -2.75E-07 -2.92E-07 -2.95E-07 -2.84E-07 -3.12E-07 -3.01E-07 -2.41E-07 -3.13E-07 Total 20 -3.17E-07 -3.09E-07 -3.65E-07 -3.18E-07 -2.88E-07 -3.03E-07 -3.07E-07 -2.96E-07 -3.25E-07 -3.13E-07 -2.43E-07 -3.14E-07 Dose (krad(Si)) 50 100 -3.24E-07 -3.40E-07 -3.21E-07 -3.34E-07 -3.78E-07 -3.90E-07 -3.29E-07 -3.41E-07 -2.97E-07 -3.10E-07 -3.18E-07 -3.37E-07 -3.21E-07 -3.39E-07 -3.09E-07 -3.27E-07 -3.39E-07 -3.64E-07 -3.27E-07 -3.52E-07 -2.43E-07 -2.43E-07 -3.14E-07 -3.14E-07 -3.07E-07 -3.19E-07 -3.30E-07 -3.43E-07 -3.70E-07 2.85E-08 2.81E-08 2.96E-08 2.90E-08 2.93E-08 -2.29E-07 -2.42E-07 -2.49E-07 -2.64E-07 -2.90E-07 -3.85E-07 -3.97E-07 -4.11E-07 -4.23E-07 -4.51E-07 -2.97E-07 1.05E-08 -2.68E-07 -3.26E-07 -7.15E-07 PASS 7.15E-07 PASS -3.09E-07 1.08E-08 -2.79E-07 -3.38E-07 -8.15E-07 PASS 8.15E-07 PASS -3.23E-07 1.11E-08 -2.92E-07 -3.53E-07 -8.65E-07 PASS 8.65E-07 PASS An ISO 9001:2008 and DSCC Certified Company 107 200 -3.65E-07 -3.66E-07 -4.16E-07 -3.70E-07 -3.34E-07 -3.69E-07 -3.76E-07 -3.60E-07 -3.93E-07 -3.83E-07 -2.42E-07 -3.13E-07 -3.44E-07 1.42E-08 -3.05E-07 -3.83E-07 -9.15E-07 PASS 9.15E-07 PASS -3.76E-07 1.25E-08 -3.42E-07 -4.11E-07 -9.65E-07 PASS 9.65E-07 PASS -Input Bias Current BIAS3 3 (A) @ VS=+/-15V, VCM=-15V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-06 1.00E-06 5.00E-07 0.00E+00 -5.00E-07 -1.00E-06 -1.50E-06 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.49. Plot of -Input Bias Current BIAS3 3 (A) @ VS=+/-15V, VCM=-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 108 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.49. Raw data for -Input Bias Current BIAS3 3 (A) @ VS=+/-15V, VCM=-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Input Bias Current BIAS3 3 (A) @ VS=+/-15V, VCM=-15V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -3.03E-07 -2.82E-07 -3.51E-07 -3.04E-07 -2.77E-07 -2.85E-07 -2.97E-07 -2.89E-07 -3.11E-07 -3.00E-07 -2.42E-07 -3.05E-07 Total 20 -3.19E-07 -2.96E-07 -3.65E-07 -3.19E-07 -2.90E-07 -2.98E-07 -3.11E-07 -3.02E-07 -3.24E-07 -3.13E-07 -2.44E-07 -3.06E-07 Dose (krad(Si)) 50 100 -3.26E-07 -3.45E-07 -3.10E-07 -3.25E-07 -3.80E-07 -3.96E-07 -3.31E-07 -3.48E-07 -3.02E-07 -3.17E-07 -3.14E-07 -3.37E-07 -3.28E-07 -3.55E-07 -3.17E-07 -3.38E-07 -3.40E-07 -3.67E-07 -3.31E-07 -3.55E-07 -2.44E-07 -2.44E-07 -3.06E-07 -3.06E-07 -3.03E-07 -3.18E-07 -3.30E-07 -3.46E-07 -3.75E-07 2.93E-08 2.95E-08 3.03E-08 3.06E-08 2.91E-08 -2.23E-07 -2.37E-07 -2.47E-07 -2.62E-07 -2.95E-07 -3.83E-07 -3.99E-07 -4.13E-07 -4.30E-07 -4.54E-07 -2.96E-07 1.01E-08 -2.69E-07 -3.24E-07 -7.15E-07 PASS 7.15E-07 PASS -3.10E-07 1.01E-08 -2.82E-07 -3.37E-07 -8.15E-07 PASS 8.15E-07 PASS -3.26E-07 1.04E-08 -2.97E-07 -3.55E-07 -8.65E-07 PASS 8.65E-07 PASS An ISO 9001:2008 and DSCC Certified Company 109 200 -3.71E-07 -3.56E-07 -4.22E-07 -3.76E-07 -3.47E-07 -3.73E-07 -3.87E-07 -3.73E-07 -3.97E-07 -3.90E-07 -2.43E-07 -3.05E-07 -3.50E-07 1.29E-08 -3.15E-07 -3.86E-07 -9.15E-07 PASS 9.15E-07 PASS -3.84E-07 1.07E-08 -3.55E-07 -4.14E-07 -9.65E-07 PASS 9.65E-07 PASS -Input Bias Current BIAS3 4 (A) @ VS=+/-15V, VCM=-15V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-06 1.00E-06 5.00E-07 0.00E+00 -5.00E-07 -1.00E-06 -1.50E-06 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.50. Plot of -Input Bias Current BIAS3 4 (A) @ VS=+/-15V, VCM=-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 110 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.50. Raw data for -Input Bias Current BIAS3 4 (A) @ VS=+/-15V, VCM=-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Input Bias Current BIAS3 4 (A) @ VS=+/-15V, VCM=-15V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -2.94E-07 -3.10E-07 -3.07E-07 -3.02E-07 -3.05E-07 -2.81E-07 -2.92E-07 -2.79E-07 -2.83E-07 -3.09E-07 -3.02E-07 -3.36E-07 Total 20 -3.08E-07 -3.22E-07 -3.18E-07 -3.16E-07 -3.18E-07 -2.92E-07 -3.03E-07 -2.91E-07 -2.94E-07 -3.20E-07 -3.05E-07 -3.38E-07 Dose (krad(Si)) 50 100 -3.14E-07 -3.31E-07 -3.34E-07 -3.51E-07 -3.32E-07 -3.50E-07 -3.27E-07 -3.41E-07 -3.31E-07 -3.53E-07 -3.07E-07 -3.26E-07 -3.17E-07 -3.34E-07 -3.04E-07 -3.23E-07 -3.09E-07 -3.27E-07 -3.36E-07 -3.58E-07 -3.06E-07 -3.05E-07 -3.38E-07 -3.37E-07 -3.04E-07 -3.16E-07 -3.28E-07 -3.45E-07 -3.73E-07 5.93E-09 5.38E-09 7.86E-09 9.14E-09 9.19E-09 -2.87E-07 -3.02E-07 -3.06E-07 -3.20E-07 -3.48E-07 -3.20E-07 -3.31E-07 -3.49E-07 -3.70E-07 -3.98E-07 -2.89E-07 1.21E-08 -2.56E-07 -3.22E-07 -7.15E-07 PASS 7.15E-07 PASS -3.00E-07 1.23E-08 -2.66E-07 -3.34E-07 -8.15E-07 PASS 8.15E-07 PASS -3.14E-07 1.29E-08 -2.79E-07 -3.50E-07 -8.65E-07 PASS 8.65E-07 PASS An ISO 9001:2008 and DSCC Certified Company 111 200 -3.58E-07 -3.78E-07 -3.76E-07 -3.72E-07 -3.81E-07 -3.59E-07 -3.69E-07 -3.56E-07 -3.59E-07 -3.94E-07 -3.05E-07 -3.36E-07 -3.34E-07 1.44E-08 -2.94E-07 -3.73E-07 -9.15E-07 PASS 9.15E-07 PASS -3.67E-07 1.57E-08 -3.24E-07 -4.10E-07 -9.65E-07 PASS 9.65E-07 PASS Output Voltage Swing High1 1 (V) @ VS=+/-15V IL=0mA TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX 2.50E-02 2.00E-02 1.50E-02 1.00E-02 5.00E-03 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.51. Plot of Output Voltage Swing High1 1 (V) @ VS=+/-15V IL=0mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 112 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.51. Raw data for Output Voltage Swing High1 1 (V) @ VS=+/-15V IL=0mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Swing High1 1 (V) @ VS=+/-15V IL=0mA Device 0 20 50 100 200 519 5.94E-03 5.78E-03 6.08E-03 6.11E-03 6.38E-03 520 5.62E-03 5.70E-03 5.96E-03 6.11E-03 6.16E-03 521 5.72E-03 5.88E-03 5.91E-03 6.16E-03 6.16E-03 522 5.92E-03 5.97E-03 6.06E-03 6.33E-03 6.46E-03 524 5.52E-03 5.72E-03 5.95E-03 5.97E-03 6.06E-03 536 5.94E-03 6.10E-03 6.32E-03 6.38E-03 6.67E-03 537 5.71E-03 6.00E-03 6.05E-03 6.28E-03 6.70E-03 538 5.79E-03 5.85E-03 6.01E-03 6.24E-03 6.55E-03 539 5.60E-03 5.72E-03 6.00E-03 6.31E-03 6.43E-03 542 5.72E-03 5.70E-03 6.08E-03 6.24E-03 6.55E-03 543 5.64E-03 5.80E-03 5.80E-03 5.71E-03 5.64E-03 544 5.55E-03 5.60E-03 5.63E-03 5.69E-03 5.69E-03 Biased Statistics Average Biased 5.74E-03 5.81E-03 5.99E-03 6.14E-03 6.24E-03 Std Dev Biased 1.84E-04 1.14E-04 7.40E-05 1.30E-04 1.68E-04 Ps90%/90% (+KTL) Biased 6.25E-03 6.12E-03 6.19E-03 6.49E-03 6.71E-03 Ps90%/90% (-KTL) Biased 5.24E-03 5.50E-03 5.79E-03 5.78E-03 5.78E-03 Un-Biased Statistics Average Un-Biased 5.75E-03 5.87E-03 6.09E-03 6.29E-03 6.58E-03 Std Dev Un-Biased 1.25E-04 1.74E-04 1.31E-04 5.83E-05 1.08E-04 Ps90%/90% (+KTL) Un-Biased 6.10E-03 6.35E-03 6.45E-03 6.45E-03 6.88E-03 Ps90%/90% (-KTL) Un-Biased 5.41E-03 5.40E-03 5.73E-03 6.13E-03 6.28E-03 Specification MAX 1.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 113 Output Voltage Swing High1 2 (V) @ VS=+/-15V IL=0mA TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX 2.50E-02 2.00E-02 1.50E-02 1.00E-02 5.00E-03 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.52. Plot of Output Voltage Swing High1 2 (V) @ VS=+/-15V IL=0mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 114 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.52. Raw data for Output Voltage Swing High1 2 (V) @ VS=+/-15V IL=0mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Swing High1 2 (V) @ VS=+/-15V IL=0mA Device 0 20 50 100 200 519 5.91E-03 6.02E-03 6.27E-03 6.23E-03 6.53E-03 520 5.69E-03 5.92E-03 6.05E-03 6.11E-03 6.36E-03 521 5.91E-03 5.92E-03 6.05E-03 6.19E-03 6.41E-03 522 5.84E-03 5.99E-03 6.05E-03 6.26E-03 6.57E-03 524 5.71E-03 5.80E-03 5.93E-03 6.09E-03 6.25E-03 536 6.21E-03 6.29E-03 6.55E-03 6.68E-03 7.00E-03 537 5.94E-03 5.97E-03 6.27E-03 6.33E-03 6.60E-03 538 5.72E-03 5.95E-03 5.93E-03 6.16E-03 6.45E-03 539 5.99E-03 6.02E-03 6.25E-03 6.43E-03 6.75E-03 542 5.84E-03 5.93E-03 6.08E-03 6.38E-03 6.68E-03 543 5.74E-03 5.67E-03 5.73E-03 5.69E-03 5.66E-03 544 5.91E-03 5.83E-03 6.00E-03 6.14E-03 6.14E-03 Biased Statistics Average Biased 5.81E-03 5.93E-03 6.07E-03 6.18E-03 6.42E-03 Std Dev Biased 1.06E-04 8.49E-05 1.23E-04 7.40E-05 1.30E-04 Ps90%/90% (+KTL) Biased 6.10E-03 6.16E-03 6.41E-03 6.38E-03 6.78E-03 Ps90%/90% (-KTL) Biased 5.52E-03 5.70E-03 5.73E-03 5.97E-03 6.07E-03 Un-Biased Statistics Average Un-Biased 5.94E-03 6.03E-03 6.22E-03 6.40E-03 6.70E-03 Std Dev Un-Biased 1.83E-04 1.48E-04 2.32E-04 1.88E-04 2.03E-04 Ps90%/90% (+KTL) Un-Biased 6.44E-03 6.44E-03 6.85E-03 6.91E-03 7.25E-03 Ps90%/90% (-KTL) Un-Biased 5.44E-03 5.63E-03 5.58E-03 5.88E-03 6.14E-03 Specification MAX 1.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 115 Output Voltage Swing High1 3 (V) @ VS=+/-15V IL=0mA TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX 2.50E-02 2.00E-02 1.50E-02 1.00E-02 5.00E-03 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.53. Plot of Output Voltage Swing High1 3 (V) @ VS=+/-15V IL=0mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 116 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.53. Raw data for Output Voltage Swing High1 3 (V) @ VS=+/-15V IL=0mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Swing High1 3 (V) @ VS=+/-15V IL=0mA Device 0 20 50 100 200 519 6.08E-03 6.24E-03 6.32E-03 6.23E-03 6.53E-03 520 6.11E-03 6.12E-03 6.17E-03 6.36E-03 6.46E-03 521 5.92E-03 6.04E-03 6.25E-03 6.23E-03 6.50E-03 522 5.72E-03 5.80E-03 5.95E-03 6.23E-03 6.26E-03 524 5.74E-03 5.83E-03 5.88E-03 6.04E-03 6.28E-03 536 6.24E-03 6.49E-03 6.55E-03 6.75E-03 6.99E-03 537 5.99E-03 5.92E-03 6.23E-03 6.41E-03 6.92E-03 538 5.86E-03 5.90E-03 6.08E-03 6.24E-03 6.50E-03 539 6.06E-03 6.22E-03 6.40E-03 6.61E-03 6.92E-03 542 5.98E-03 5.95E-03 6.32E-03 6.45E-03 6.58E-03 543 5.64E-03 5.87E-03 5.73E-03 5.86E-03 5.89E-03 544 5.69E-03 5.88E-03 5.86E-03 5.87E-03 6.03E-03 Biased Statistics Average Biased 5.91E-03 6.01E-03 6.11E-03 6.22E-03 6.41E-03 Std Dev Biased 1.83E-04 1.89E-04 1.91E-04 1.14E-04 1.27E-04 Ps90%/90% (+KTL) Biased 6.42E-03 6.52E-03 6.64E-03 6.53E-03 6.75E-03 Ps90%/90% (-KTL) Biased 5.41E-03 5.49E-03 5.59E-03 5.90E-03 6.06E-03 Un-Biased Statistics Average Un-Biased 6.03E-03 6.10E-03 6.32E-03 6.49E-03 6.78E-03 Std Dev Un-Biased 1.40E-04 2.56E-04 1.77E-04 1.95E-04 2.25E-04 Ps90%/90% (+KTL) Un-Biased 6.41E-03 6.80E-03 6.80E-03 7.03E-03 7.40E-03 Ps90%/90% (-KTL) Un-Biased 5.64E-03 5.40E-03 5.83E-03 5.96E-03 6.17E-03 Specification MAX 1.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 117 Output Voltage Swing High1 4 (V) @ VS=+/-15V IL=0mA TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX 2.50E-02 2.00E-02 1.50E-02 1.00E-02 5.00E-03 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.54. Plot of Output Voltage Swing High1 4 (V) @ VS=+/-15V IL=0mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 118 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.54. Raw data for Output Voltage Swing High1 4 (V) @ VS=+/-15V IL=0mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Swing High1 4 (V) @ VS=+/-15V IL=0mA Device 0 20 50 100 200 519 6.09E-03 6.20E-03 6.28E-03 6.40E-03 6.65E-03 520 5.89E-03 5.93E-03 6.13E-03 6.28E-03 6.53E-03 521 5.81E-03 5.88E-03 6.03E-03 6.29E-03 6.41E-03 522 6.19E-03 6.22E-03 6.44E-03 6.60E-03 6.68E-03 524 6.28E-03 6.24E-03 6.62E-03 6.67E-03 6.89E-03 536 5.94E-03 6.02E-03 6.05E-03 6.33E-03 6.51E-03 537 5.99E-03 6.09E-03 6.15E-03 6.33E-03 6.68E-03 538 5.86E-03 5.97E-03 6.22E-03 6.23E-03 6.62E-03 539 5.94E-03 5.82E-03 6.10E-03 6.31E-03 6.70E-03 542 6.26E-03 6.17E-03 6.49E-03 6.55E-03 6.90E-03 543 5.74E-03 5.87E-03 5.83E-03 5.76E-03 5.74E-03 544 5.76E-03 5.83E-03 5.80E-03 5.87E-03 5.93E-03 Biased Statistics Average Biased 6.05E-03 6.09E-03 6.30E-03 6.45E-03 6.63E-03 Std Dev Biased 1.98E-04 1.74E-04 2.37E-04 1.79E-04 1.79E-04 Ps90%/90% (+KTL) Biased 6.60E-03 6.57E-03 6.95E-03 6.94E-03 7.12E-03 Ps90%/90% (-KTL) Biased 5.51E-03 5.62E-03 5.65E-03 5.96E-03 6.14E-03 Un-Biased Statistics Average Un-Biased 6.00E-03 6.01E-03 6.20E-03 6.35E-03 6.68E-03 Std Dev Un-Biased 1.54E-04 1.32E-04 1.73E-04 1.19E-04 1.43E-04 Ps90%/90% (+KTL) Un-Biased 6.42E-03 6.38E-03 6.68E-03 6.68E-03 7.07E-03 Ps90%/90% (-KTL) Un-Biased 5.58E-03 5.65E-03 5.73E-03 6.02E-03 6.29E-03 Specification MAX 1.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 119 Output Voltage Swing High2 1 (V) @ VS=+/-15V IL=1mA TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX 1.60E-01 1.40E-01 1.20E-01 1.00E-01 8.00E-02 6.00E-02 4.00E-02 2.00E-02 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.55. Plot of Output Voltage Swing High2 1 (V) @ VS=+/-15V IL=1mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 120 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.55. Raw data for Output Voltage Swing High2 1 (V) @ VS=+/-15V IL=1mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Swing High2 1 (V) @ VS=+/-15V IL=1mA Device 0 20 50 100 200 519 7.22E-02 7.32E-02 7.47E-02 7.50E-02 7.57E-02 520 6.85E-02 6.99E-02 7.05E-02 7.11E-02 7.14E-02 521 6.84E-02 6.99E-02 7.04E-02 7.10E-02 7.16E-02 522 7.35E-02 7.47E-02 7.54E-02 7.60E-02 7.66E-02 524 6.79E-02 6.80E-02 6.93E-02 7.00E-02 7.05E-02 536 6.99E-02 7.02E-02 7.08E-02 7.13E-02 7.21E-02 537 7.16E-02 7.18E-02 7.22E-02 7.28E-02 7.35E-02 538 7.11E-02 7.13E-02 7.20E-02 7.25E-02 7.33E-02 539 6.99E-02 7.02E-02 7.07E-02 7.13E-02 7.20E-02 542 7.06E-02 7.08E-02 7.12E-02 7.19E-02 7.27E-02 543 6.88E-02 6.83E-02 6.84E-02 6.83E-02 6.83E-02 544 6.47E-02 6.46E-02 6.45E-02 6.47E-02 6.47E-02 Biased Statistics Average Biased 7.01E-02 7.11E-02 7.21E-02 7.26E-02 7.32E-02 Std Dev Biased 2.56E-03 2.74E-03 2.81E-03 2.69E-03 2.78E-03 Ps90%/90% (+KTL) Biased 7.71E-02 7.87E-02 7.98E-02 8.00E-02 8.08E-02 Ps90%/90% (-KTL) Biased 6.31E-02 6.36E-02 6.44E-02 6.52E-02 6.56E-02 Un-Biased Statistics Average Un-Biased 7.06E-02 7.09E-02 7.14E-02 7.20E-02 7.27E-02 Std Dev Un-Biased 7.31E-04 7.11E-04 6.86E-04 6.67E-04 6.74E-04 Ps90%/90% (+KTL) Un-Biased 7.26E-02 7.28E-02 7.33E-02 7.38E-02 7.46E-02 Ps90%/90% (-KTL) Un-Biased 6.86E-02 6.89E-02 6.95E-02 7.01E-02 7.09E-02 Specification MAX 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 121 Output Voltage Swing High2 2 (V) @ VS=+/-15V IL=1mA TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX 1.60E-01 1.40E-01 1.20E-01 1.00E-01 8.00E-02 6.00E-02 4.00E-02 2.00E-02 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.56. Plot of Output Voltage Swing High2 2 (V) @ VS=+/-15V IL=1mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 122 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.56. Raw data for Output Voltage Swing High2 2 (V) @ VS=+/-15V IL=1mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Swing High2 2 (V) @ VS=+/-15V IL=1mA Device 0 20 50 100 200 519 7.14E-02 7.20E-02 7.38E-02 7.36E-02 7.44E-02 520 6.94E-02 7.07E-02 7.14E-02 7.20E-02 7.26E-02 521 6.77E-02 6.88E-02 6.94E-02 7.00E-02 7.06E-02 522 6.78E-02 6.85E-02 6.94E-02 7.00E-02 7.07E-02 524 6.72E-02 6.73E-02 6.90E-02 6.95E-02 7.01E-02 536 6.96E-02 6.97E-02 7.01E-02 7.08E-02 7.17E-02 537 7.06E-02 7.07E-02 7.15E-02 7.17E-02 7.27E-02 538 6.78E-02 6.81E-02 6.88E-02 6.93E-02 6.99E-02 539 7.09E-02 7.11E-02 7.18E-02 7.23E-02 7.31E-02 542 7.04E-02 7.08E-02 7.12E-02 7.19E-02 7.26E-02 543 6.93E-02 6.91E-02 6.91E-02 6.91E-02 6.92E-02 544 6.71E-02 6.71E-02 6.70E-02 6.68E-02 6.70E-02 Biased Statistics Average Biased 6.87E-02 6.94E-02 7.06E-02 7.10E-02 7.17E-02 Std Dev Biased 1.71E-03 1.88E-03 2.02E-03 1.75E-03 1.79E-03 Ps90%/90% (+KTL) Biased 7.34E-02 7.46E-02 7.61E-02 7.58E-02 7.66E-02 Ps90%/90% (-KTL) Biased 6.40E-02 6.43E-02 6.50E-02 6.62E-02 6.68E-02 Un-Biased Statistics Average Un-Biased 6.99E-02 7.01E-02 7.07E-02 7.12E-02 7.20E-02 Std Dev Un-Biased 1.23E-03 1.25E-03 1.24E-03 1.19E-03 1.30E-03 Ps90%/90% (+KTL) Un-Biased 7.33E-02 7.35E-02 7.41E-02 7.45E-02 7.55E-02 Ps90%/90% (-KTL) Un-Biased 6.65E-02 6.66E-02 6.73E-02 6.79E-02 6.84E-02 Specification MAX 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 123 Output Voltage Swing High2 3 (V) @ VS=+/-15V IL=1mA TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX 1.60E-01 1.40E-01 1.20E-01 1.00E-01 8.00E-02 6.00E-02 4.00E-02 2.00E-02 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.57. Plot of Output Voltage Swing High2 3 (V) @ VS=+/-15V IL=1mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 124 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.57. Raw data for Output Voltage Swing High2 3 (V) @ VS=+/-15V IL=1mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Swing High2 3 (V) @ VS=+/-15V IL=1mA Device 0 20 50 100 200 519 7.12E-02 7.21E-02 7.36E-02 7.36E-02 7.43E-02 520 7.03E-02 7.15E-02 7.24E-02 7.29E-02 7.36E-02 521 6.78E-02 6.87E-02 6.96E-02 7.02E-02 7.07E-02 522 6.77E-02 6.85E-02 6.93E-02 7.00E-02 7.06E-02 524 6.73E-02 6.74E-02 6.86E-02 6.96E-02 7.01E-02 536 6.94E-02 6.98E-02 7.04E-02 7.09E-02 7.17E-02 537 7.11E-02 7.13E-02 7.17E-02 7.25E-02 7.32E-02 538 6.81E-02 6.79E-02 6.88E-02 6.92E-02 6.99E-02 539 7.10E-02 7.13E-02 7.16E-02 7.22E-02 7.32E-02 542 7.03E-02 7.06E-02 7.12E-02 7.19E-02 7.26E-02 543 7.02E-02 6.96E-02 6.97E-02 6.96E-02 6.98E-02 544 6.75E-02 6.75E-02 6.74E-02 6.75E-02 6.75E-02 Biased Statistics Average Biased 6.88E-02 6.96E-02 7.07E-02 7.13E-02 7.19E-02 Std Dev Biased 1.79E-03 2.05E-03 2.18E-03 1.86E-03 1.94E-03 Ps90%/90% (+KTL) Biased 7.38E-02 7.52E-02 7.67E-02 7.64E-02 7.72E-02 Ps90%/90% (-KTL) Biased 6.39E-02 6.40E-02 6.47E-02 6.62E-02 6.66E-02 Un-Biased Statistics Average Un-Biased 7.00E-02 7.02E-02 7.08E-02 7.13E-02 7.21E-02 Std Dev Un-Biased 1.28E-03 1.43E-03 1.20E-03 1.34E-03 1.37E-03 Ps90%/90% (+KTL) Un-Biased 7.35E-02 7.41E-02 7.40E-02 7.50E-02 7.59E-02 Ps90%/90% (-KTL) Un-Biased 6.65E-02 6.63E-02 6.75E-02 6.76E-02 6.84E-02 Specification MAX 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 125 Output Voltage Swing High2 4 (V) @ VS=+/-15V IL=1mA TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX 1.60E-01 1.40E-01 1.20E-01 1.00E-01 8.00E-02 6.00E-02 4.00E-02 2.00E-02 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.58. Plot of Output Voltage Swing High2 4 (V) @ VS=+/-15V IL=1mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 126 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.58. Raw data for Output Voltage Swing High2 4 (V) @ VS=+/-15V IL=1mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Swing High2 4 (V) @ VS=+/-15V IL=1mA Device 0 20 50 100 200 519 7.30E-02 7.39E-02 7.56E-02 7.55E-02 7.61E-02 520 6.89E-02 7.02E-02 7.08E-02 7.16E-02 7.21E-02 521 6.85E-02 6.99E-02 7.04E-02 7.12E-02 7.17E-02 522 7.35E-02 7.45E-02 7.56E-02 7.59E-02 7.68E-02 524 6.76E-02 6.78E-02 6.90E-02 6.97E-02 7.02E-02 536 7.01E-02 7.03E-02 7.11E-02 7.13E-02 7.22E-02 537 7.10E-02 7.12E-02 7.18E-02 7.25E-02 7.32E-02 538 7.13E-02 7.19E-02 7.23E-02 7.30E-02 7.38E-02 539 7.01E-02 7.04E-02 7.11E-02 7.16E-02 7.24E-02 542 7.04E-02 7.08E-02 7.12E-02 7.19E-02 7.26E-02 543 6.83E-02 6.80E-02 6.81E-02 6.80E-02 6.82E-02 544 6.46E-02 6.44E-02 6.45E-02 6.46E-02 6.47E-02 Biased Statistics Average Biased 7.03E-02 7.12E-02 7.23E-02 7.28E-02 7.34E-02 Std Dev Biased 2.75E-03 2.88E-03 3.09E-03 2.78E-03 2.87E-03 Ps90%/90% (+KTL) Biased 7.78E-02 7.91E-02 8.07E-02 8.04E-02 8.13E-02 Ps90%/90% (-KTL) Biased 6.28E-02 6.33E-02 6.38E-02 6.52E-02 6.55E-02 Un-Biased Statistics Average Un-Biased 7.06E-02 7.09E-02 7.15E-02 7.20E-02 7.28E-02 Std Dev Un-Biased 5.74E-04 6.49E-04 5.16E-04 6.80E-04 6.37E-04 Ps90%/90% (+KTL) Un-Biased 7.22E-02 7.27E-02 7.29E-02 7.39E-02 7.46E-02 Ps90%/90% (-KTL) Un-Biased 6.90E-02 6.91E-02 7.01E-02 7.02E-02 7.11E-02 Specification MAX 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 127 Output Voltage Swing High3 1 (V) @ VS=+/-15V IL=10mA TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX 9.00E-01 8.00E-01 7.00E-01 6.00E-01 5.00E-01 4.00E-01 3.00E-01 2.00E-01 1.00E-01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.59. Plot of Output Voltage Swing High3 1 (V) @ VS=+/-15V IL=10mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 128 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.59. Raw data for Output Voltage Swing High3 1 (V) @ VS=+/-15V IL=10mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Swing High3 1 (V) @ VS=+/-15V IL=10mA Device 0 20 50 100 200 519 3.80E-01 3.81E-01 3.89E-01 3.89E-01 3.94E-01 520 3.61E-01 3.64E-01 3.66E-01 3.69E-01 3.73E-01 521 3.59E-01 3.62E-01 3.64E-01 3.68E-01 3.71E-01 522 3.84E-01 3.86E-01 3.91E-01 3.94E-01 4.01E-01 524 3.59E-01 3.59E-01 3.63E-01 3.66E-01 3.69E-01 536 3.67E-01 3.69E-01 3.71E-01 3.74E-01 3.79E-01 537 3.74E-01 3.75E-01 3.78E-01 3.81E-01 3.86E-01 538 3.74E-01 3.76E-01 3.78E-01 3.82E-01 3.87E-01 539 3.68E-01 3.69E-01 3.72E-01 3.75E-01 3.80E-01 542 3.70E-01 3.71E-01 3.74E-01 3.77E-01 3.82E-01 543 3.60E-01 3.58E-01 3.58E-01 3.57E-01 3.58E-01 544 3.43E-01 3.42E-01 3.42E-01 3.42E-01 3.43E-01 Biased Statistics Average Biased 3.68E-01 3.70E-01 3.75E-01 3.77E-01 3.81E-01 Std Dev Biased 1.22E-02 1.24E-02 1.39E-02 1.32E-02 1.46E-02 Ps90%/90% (+KTL) Biased 4.02E-01 4.04E-01 4.13E-01 4.14E-01 4.21E-01 Ps90%/90% (-KTL) Biased 3.35E-01 3.36E-01 3.36E-01 3.41E-01 3.42E-01 Un-Biased Statistics Average Un-Biased 3.71E-01 3.72E-01 3.74E-01 3.78E-01 3.83E-01 Std Dev Un-Biased 3.27E-03 3.26E-03 3.46E-03 3.70E-03 3.70E-03 Ps90%/90% (+KTL) Un-Biased 3.80E-01 3.81E-01 3.84E-01 3.88E-01 3.93E-01 Ps90%/90% (-KTL) Un-Biased 3.62E-01 3.63E-01 3.65E-01 3.68E-01 3.73E-01 Specification MAX 8.00E-01 8.00E-01 8.00E-01 8.00E-01 8.00E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 129 Output Voltage Swing High3 2 (V) @ VS=+/-15V IL=10mA TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX 9.00E-01 8.00E-01 7.00E-01 6.00E-01 5.00E-01 4.00E-01 3.00E-01 2.00E-01 1.00E-01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.60. Plot of Output Voltage Swing High3 2 (V) @ VS=+/-15V IL=10mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 130 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.60. Raw data for Output Voltage Swing High3 2 (V) @ VS=+/-15V IL=10mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Swing High3 2 (V) @ VS=+/-15V IL=10mA Device 0 20 50 100 200 519 3.74E-01 3.75E-01 3.82E-01 3.82E-01 3.87E-01 520 3.65E-01 3.68E-01 3.71E-01 3.73E-01 3.78E-01 521 3.55E-01 3.57E-01 3.60E-01 3.63E-01 3.66E-01 522 3.54E-01 3.55E-01 3.59E-01 3.61E-01 3.65E-01 524 3.55E-01 3.55E-01 3.59E-01 3.63E-01 3.66E-01 536 3.66E-01 3.67E-01 3.68E-01 3.71E-01 3.76E-01 537 3.70E-01 3.70E-01 3.73E-01 3.77E-01 3.81E-01 538 3.58E-01 3.58E-01 3.61E-01 3.64E-01 3.68E-01 539 3.72E-01 3.73E-01 3.75E-01 3.78E-01 3.84E-01 542 3.69E-01 3.70E-01 3.73E-01 3.77E-01 3.82E-01 543 3.67E-01 3.65E-01 3.65E-01 3.65E-01 3.65E-01 544 3.52E-01 3.51E-01 3.51E-01 3.51E-01 3.52E-01 Biased Statistics Average Biased 3.61E-01 3.62E-01 3.66E-01 3.68E-01 3.72E-01 Std Dev Biased 8.54E-03 8.74E-03 1.03E-02 8.89E-03 9.60E-03 Ps90%/90% (+KTL) Biased 3.84E-01 3.86E-01 3.94E-01 3.93E-01 3.99E-01 Ps90%/90% (-KTL) Biased 3.37E-01 3.38E-01 3.38E-01 3.44E-01 3.46E-01 Un-Biased Statistics Average Un-Biased 3.67E-01 3.68E-01 3.70E-01 3.73E-01 3.78E-01 Std Dev Un-Biased 5.62E-03 5.79E-03 5.80E-03 6.03E-03 6.44E-03 Ps90%/90% (+KTL) Un-Biased 3.82E-01 3.84E-01 3.86E-01 3.90E-01 3.96E-01 Ps90%/90% (-KTL) Un-Biased 3.52E-01 3.52E-01 3.54E-01 3.57E-01 3.60E-01 Specification MAX 8.00E-01 8.00E-01 8.00E-01 8.00E-01 8.00E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 131 Output Voltage Swing High3 3 (V) @ VS=+/-15V IL=10mA TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX 9.00E-01 8.00E-01 7.00E-01 6.00E-01 5.00E-01 4.00E-01 3.00E-01 2.00E-01 1.00E-01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.61. Plot of Output Voltage Swing High3 3 (V) @ VS=+/-15V IL=10mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 132 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.61. Raw data for Output Voltage Swing High3 3 (V) @ VS=+/-15V IL=10mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Swing High3 3 (V) @ VS=+/-15V IL=10mA Device 0 20 50 100 200 519 3.74E-01 3.75E-01 3.83E-01 3.83E-01 3.88E-01 520 3.69E-01 3.72E-01 3.76E-01 3.79E-01 3.83E-01 521 3.55E-01 3.57E-01 3.59E-01 3.63E-01 3.65E-01 522 3.55E-01 3.56E-01 3.59E-01 3.61E-01 3.65E-01 524 3.55E-01 3.55E-01 3.60E-01 3.63E-01 3.66E-01 536 3.66E-01 3.66E-01 3.69E-01 3.72E-01 3.77E-01 537 3.72E-01 3.73E-01 3.76E-01 3.79E-01 3.85E-01 538 3.58E-01 3.59E-01 3.61E-01 3.64E-01 3.68E-01 539 3.72E-01 3.73E-01 3.75E-01 3.78E-01 3.83E-01 542 3.69E-01 3.70E-01 3.73E-01 3.76E-01 3.81E-01 543 3.69E-01 3.67E-01 3.68E-01 3.67E-01 3.68E-01 544 3.54E-01 3.53E-01 3.53E-01 3.53E-01 3.54E-01 Biased Statistics Average Biased 3.62E-01 3.63E-01 3.67E-01 3.70E-01 3.74E-01 Std Dev Biased 9.38E-03 9.81E-03 1.13E-02 1.02E-02 1.10E-02 Ps90%/90% (+KTL) Biased 3.88E-01 3.90E-01 3.98E-01 3.98E-01 4.04E-01 Ps90%/90% (-KTL) Biased 3.36E-01 3.36E-01 3.36E-01 3.42E-01 3.44E-01 Un-Biased Statistics Average Un-Biased 3.67E-01 3.68E-01 3.71E-01 3.74E-01 3.79E-01 Std Dev Un-Biased 5.78E-03 5.97E-03 5.95E-03 6.32E-03 6.62E-03 Ps90%/90% (+KTL) Un-Biased 3.83E-01 3.84E-01 3.87E-01 3.91E-01 3.97E-01 Ps90%/90% (-KTL) Un-Biased 3.52E-01 3.52E-01 3.55E-01 3.57E-01 3.60E-01 Specification MAX 8.00E-01 8.00E-01 8.00E-01 8.00E-01 8.00E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 133 Output Voltage Swing High3 4 (V) @ VS=+/-15V IL=10mA TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX 9.00E-01 8.00E-01 7.00E-01 6.00E-01 5.00E-01 4.00E-01 3.00E-01 2.00E-01 1.00E-01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.62. Plot of Output Voltage Swing High3 4 (V) @ VS=+/-15V IL=10mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 134 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.62. Raw data for Output Voltage Swing High3 4 (V) @ VS=+/-15V IL=10mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Swing High3 4 (V) @ VS=+/-15V IL=10mA Device 0 20 50 100 200 519 3.82E-01 3.84E-01 3.91E-01 3.92E-01 3.97E-01 520 3.62E-01 3.65E-01 3.68E-01 3.71E-01 3.75E-01 521 3.60E-01 3.63E-01 3.65E-01 3.69E-01 3.72E-01 522 3.84E-01 3.87E-01 3.91E-01 3.95E-01 4.01E-01 524 3.57E-01 3.57E-01 3.61E-01 3.64E-01 3.67E-01 536 3.69E-01 3.70E-01 3.73E-01 3.75E-01 3.81E-01 537 3.73E-01 3.73E-01 3.76E-01 3.79E-01 3.84E-01 538 3.76E-01 3.77E-01 3.81E-01 3.84E-01 3.90E-01 539 3.70E-01 3.70E-01 3.74E-01 3.77E-01 3.82E-01 542 3.69E-01 3.70E-01 3.73E-01 3.76E-01 3.81E-01 543 3.58E-01 3.56E-01 3.56E-01 3.56E-01 3.57E-01 544 3.43E-01 3.42E-01 3.42E-01 3.42E-01 3.43E-01 Biased Statistics Average Biased 3.69E-01 3.71E-01 3.75E-01 3.78E-01 3.82E-01 Std Dev Biased 1.28E-02 1.33E-02 1.48E-02 1.43E-02 1.53E-02 Ps90%/90% (+KTL) Biased 4.04E-01 4.08E-01 4.16E-01 4.17E-01 4.24E-01 Ps90%/90% (-KTL) Biased 3.34E-01 3.35E-01 3.35E-01 3.39E-01 3.40E-01 Un-Biased Statistics Average Un-Biased 3.71E-01 3.72E-01 3.75E-01 3.78E-01 3.84E-01 Std Dev Un-Biased 3.02E-03 3.11E-03 3.36E-03 3.68E-03 3.66E-03 Ps90%/90% (+KTL) Un-Biased 3.80E-01 3.81E-01 3.84E-01 3.88E-01 3.94E-01 Ps90%/90% (-KTL) Un-Biased 3.63E-01 3.64E-01 3.66E-01 3.68E-01 3.74E-01 Specification MAX 8.00E-01 8.00E-01 8.00E-01 8.00E-01 8.00E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 135 Output Voltage Swing Low1 1 (V) @ VS=+/-15V IL=0mA TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX 7.00E-02 6.00E-02 5.00E-02 4.00E-02 3.00E-02 2.00E-02 1.00E-02 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.63. Plot of Output Voltage Swing Low1 1 (V) @ VS=+/-15V IL=0mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 136 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.63. Raw data for Output Voltage Swing Low1 1 (V) @ VS=+/-15V IL=0mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Swing Low1 1 (V) @ VS=+/-15V IL=0mA Device 0 20 50 100 200 519 1.87E-02 1.89E-02 1.96E-02 1.95E-02 1.98E-02 520 1.86E-02 1.89E-02 1.90E-02 1.93E-02 1.97E-02 521 1.79E-02 1.82E-02 1.82E-02 1.86E-02 1.88E-02 522 1.78E-02 1.80E-02 1.82E-02 1.84E-02 1.90E-02 524 1.85E-02 1.86E-02 1.91E-02 1.92E-02 1.97E-02 536 1.90E-02 1.91E-02 1.94E-02 1.96E-02 2.00E-02 537 1.92E-02 1.91E-02 1.93E-02 1.96E-02 1.99E-02 538 1.86E-02 1.87E-02 1.88E-02 1.92E-02 1.97E-02 539 1.90E-02 1.91E-02 1.94E-02 1.97E-02 2.01E-02 542 1.80E-02 1.79E-02 1.83E-02 1.88E-02 1.89E-02 543 1.83E-02 1.82E-02 1.82E-02 1.81E-02 1.81E-02 544 1.74E-02 1.72E-02 1.73E-02 1.73E-02 1.73E-02 Biased Statistics Average Biased 1.83E-02 1.85E-02 1.88E-02 1.90E-02 1.94E-02 Std Dev Biased 4.21E-04 3.95E-04 5.98E-04 4.62E-04 4.81E-04 Ps90%/90% (+KTL) Biased 1.95E-02 1.96E-02 2.04E-02 2.03E-02 2.07E-02 Ps90%/90% (-KTL) Biased 1.72E-02 1.74E-02 1.72E-02 1.77E-02 1.81E-02 Un-Biased Statistics Average Un-Biased 1.87E-02 1.88E-02 1.90E-02 1.94E-02 1.97E-02 Std Dev Un-Biased 4.73E-04 4.94E-04 4.94E-04 3.90E-04 4.97E-04 Ps90%/90% (+KTL) Un-Biased 2.00E-02 2.01E-02 2.04E-02 2.04E-02 2.11E-02 Ps90%/90% (-KTL) Un-Biased 1.74E-02 1.74E-02 1.77E-02 1.83E-02 1.83E-02 Specification MAX 3.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 137 Output Voltage Swing Low1 2 (V) @ VS=+/-15V IL=0mA TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX 7.00E-02 6.00E-02 5.00E-02 4.00E-02 3.00E-02 2.00E-02 1.00E-02 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.64. Plot of Output Voltage Swing Low1 2 (V) @ VS=+/-15V IL=0mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 138 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.64. Raw data for Output Voltage Swing Low1 2 (V) @ VS=+/-15V IL=0mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Swing Low1 2 (V) @ VS=+/-15V IL=0mA Device 0 20 50 100 200 519 1.80E-02 1.83E-02 1.86E-02 1.87E-02 1.93E-02 520 1.92E-02 1.95E-02 1.96E-02 1.99E-02 2.04E-02 521 1.78E-02 1.82E-02 1.82E-02 1.84E-02 1.89E-02 522 1.87E-02 1.89E-02 1.91E-02 1.94E-02 1.99E-02 524 1.95E-02 1.97E-02 2.00E-02 2.06E-02 2.08E-02 536 1.90E-02 1.91E-02 1.92E-02 1.97E-02 2.01E-02 537 1.84E-02 1.85E-02 1.87E-02 1.90E-02 1.95E-02 538 1.91E-02 1.93E-02 1.94E-02 1.97E-02 2.02E-02 539 1.82E-02 1.85E-02 1.86E-02 1.88E-02 1.93E-02 542 1.80E-02 1.82E-02 1.83E-02 1.86E-02 1.92E-02 543 2.17E-02 2.15E-02 2.14E-02 2.15E-02 2.15E-02 544 1.91E-02 1.91E-02 1.90E-02 1.91E-02 1.91E-02 Biased Statistics Average Biased 1.86E-02 1.89E-02 1.91E-02 1.94E-02 1.98E-02 Std Dev Biased 7.42E-04 6.75E-04 7.18E-04 8.86E-04 7.83E-04 Ps90%/90% (+KTL) Biased 2.07E-02 2.08E-02 2.11E-02 2.18E-02 2.20E-02 Ps90%/90% (-KTL) Biased 1.66E-02 1.71E-02 1.72E-02 1.70E-02 1.77E-02 Un-Biased Statistics Average Un-Biased 1.86E-02 1.87E-02 1.88E-02 1.91E-02 1.96E-02 Std Dev Un-Biased 4.78E-04 4.68E-04 4.49E-04 4.96E-04 4.69E-04 Ps90%/90% (+KTL) Un-Biased 1.99E-02 2.00E-02 2.01E-02 2.05E-02 2.09E-02 Ps90%/90% (-KTL) Un-Biased 1.72E-02 1.74E-02 1.76E-02 1.78E-02 1.84E-02 Specification MAX 3.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 139 Output Voltage Swing Low1 3 (V) @ VS=+/-15V IL=0mA TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX 7.00E-02 6.00E-02 5.00E-02 4.00E-02 3.00E-02 2.00E-02 1.00E-02 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.65. Plot of Output Voltage Swing Low1 3 (V) @ VS=+/-15V IL=0mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 140 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.65. Raw data for Output Voltage Swing Low1 3 (V) @ VS=+/-15V IL=0mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Swing Low1 3 (V) @ VS=+/-15V IL=0mA Device 0 20 50 100 200 519 1.81E-02 1.83E-02 1.88E-02 1.88E-02 1.93E-02 520 1.90E-02 1.95E-02 1.96E-02 1.99E-02 2.04E-02 521 1.72E-02 1.76E-02 1.77E-02 1.79E-02 1.82E-02 522 1.84E-02 1.85E-02 1.89E-02 1.91E-02 1.95E-02 524 1.94E-02 1.92E-02 1.99E-02 2.00E-02 2.06E-02 536 1.88E-02 1.88E-02 1.91E-02 1.94E-02 1.98E-02 537 1.82E-02 1.82E-02 1.85E-02 1.87E-02 1.91E-02 538 1.89E-02 1.91E-02 1.93E-02 1.94E-02 1.98E-02 539 1.78E-02 1.78E-02 1.81E-02 1.83E-02 1.88E-02 542 1.77E-02 1.78E-02 1.81E-02 1.83E-02 1.86E-02 543 2.12E-02 2.13E-02 2.12E-02 2.12E-02 2.13E-02 544 1.82E-02 1.83E-02 1.81E-02 1.82E-02 1.83E-02 Biased Statistics Average Biased 1.84E-02 1.86E-02 1.90E-02 1.91E-02 1.96E-02 Std Dev Biased 8.45E-04 7.51E-04 8.45E-04 8.59E-04 9.45E-04 Ps90%/90% (+KTL) Biased 2.07E-02 2.07E-02 2.13E-02 2.15E-02 2.22E-02 Ps90%/90% (-KTL) Biased 1.61E-02 1.66E-02 1.67E-02 1.68E-02 1.70E-02 Un-Biased Statistics Average Un-Biased 1.83E-02 1.83E-02 1.86E-02 1.88E-02 1.92E-02 Std Dev Un-Biased 5.41E-04 5.86E-04 5.30E-04 5.46E-04 5.87E-04 Ps90%/90% (+KTL) Un-Biased 1.98E-02 1.99E-02 2.01E-02 2.03E-02 2.08E-02 Ps90%/90% (-KTL) Un-Biased 1.68E-02 1.67E-02 1.71E-02 1.73E-02 1.76E-02 Specification MAX 3.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 141 Output Voltage Swing Low1 4 (V) @ VS=+/-15V IL=0mA TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX 7.00E-02 6.00E-02 5.00E-02 4.00E-02 3.00E-02 2.00E-02 1.00E-02 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.66. Plot of Output Voltage Swing Low1 4 (V) @ VS=+/-15V IL=0mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 142 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.66. Raw data for Output Voltage Swing Low1 4 (V) @ VS=+/-15V IL=0mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Swing Low1 4 (V) @ VS=+/-15V IL=0mA Device 0 20 50 100 200 519 1.87E-02 1.89E-02 1.94E-02 1.93E-02 1.97E-02 520 1.91E-02 1.91E-02 1.94E-02 1.98E-02 2.02E-02 521 1.85E-02 1.90E-02 1.91E-02 1.94E-02 1.98E-02 522 1.81E-02 1.83E-02 1.85E-02 1.87E-02 1.92E-02 524 1.81E-02 1.80E-02 1.84E-02 1.88E-02 1.92E-02 536 1.92E-02 1.93E-02 1.95E-02 1.98E-02 2.04E-02 537 1.93E-02 1.91E-02 1.94E-02 1.99E-02 2.01E-02 538 1.85E-02 1.86E-02 1.88E-02 1.92E-02 1.96E-02 539 1.95E-02 1.96E-02 1.99E-02 2.00E-02 2.05E-02 542 1.81E-02 1.81E-02 1.83E-02 1.88E-02 1.92E-02 543 1.86E-02 1.86E-02 1.84E-02 1.85E-02 1.84E-02 544 1.74E-02 1.72E-02 1.72E-02 1.73E-02 1.74E-02 Biased Statistics Average Biased 1.85E-02 1.87E-02 1.90E-02 1.92E-02 1.96E-02 Std Dev Biased 4.10E-04 4.68E-04 4.71E-04 4.48E-04 4.67E-04 Ps90%/90% (+KTL) Biased 1.96E-02 1.99E-02 2.03E-02 2.04E-02 2.09E-02 Ps90%/90% (-KTL) Biased 1.74E-02 1.74E-02 1.77E-02 1.80E-02 1.83E-02 Un-Biased Statistics Average Un-Biased 1.89E-02 1.90E-02 1.92E-02 1.95E-02 2.00E-02 Std Dev Un-Biased 5.94E-04 6.00E-04 6.41E-04 5.25E-04 5.41E-04 Ps90%/90% (+KTL) Un-Biased 2.05E-02 2.06E-02 2.09E-02 2.10E-02 2.14E-02 Ps90%/90% (-KTL) Un-Biased 1.73E-02 1.73E-02 1.74E-02 1.81E-02 1.85E-02 Specification MAX 3.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 143 Output Voltage Swing Low2 1 (V) @ VS=+/-15V IL=1mA TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX 1.20E-01 1.00E-01 8.00E-02 6.00E-02 4.00E-02 2.00E-02 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.67. Plot of Output Voltage Swing Low2 1 (V) @ VS=+/-15V IL=1mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 144 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.67. Raw data for Output Voltage Swing Low2 1 (V) @ VS=+/-15V IL=1mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Swing Low2 1 (V) @ VS=+/-15V IL=1mA Device 0 20 50 100 200 519 5.30E-02 5.30E-02 5.38E-02 5.38E-02 5.40E-02 520 5.21E-02 5.23E-02 5.26E-02 5.29E-02 5.36E-02 521 5.13E-02 5.16E-02 5.16E-02 5.23E-02 5.23E-02 522 5.21E-02 5.20E-02 5.25E-02 5.28E-02 5.33E-02 524 5.22E-02 5.20E-02 5.25E-02 5.28E-02 5.34E-02 536 5.31E-02 5.32E-02 5.34E-02 5.34E-02 5.38E-02 537 5.31E-02 5.29E-02 5.32E-02 5.34E-02 5.39E-02 538 5.29E-02 5.30E-02 5.31E-02 5.35E-02 5.39E-02 539 5.34E-02 5.33E-02 5.34E-02 5.38E-02 5.41E-02 542 5.19E-02 5.19E-02 5.21E-02 5.24E-02 5.27E-02 543 5.15E-02 5.13E-02 5.13E-02 5.13E-02 5.14E-02 544 4.97E-02 4.96E-02 4.96E-02 4.95E-02 4.98E-02 Biased Statistics Average Biased 5.21E-02 5.22E-02 5.26E-02 5.29E-02 5.33E-02 Std Dev Biased 6.22E-04 5.41E-04 7.61E-04 5.45E-04 6.30E-04 Ps90%/90% (+KTL) Biased 5.39E-02 5.37E-02 5.47E-02 5.44E-02 5.51E-02 Ps90%/90% (-KTL) Biased 5.04E-02 5.07E-02 5.05E-02 5.14E-02 5.16E-02 Un-Biased Statistics Average Un-Biased 5.29E-02 5.28E-02 5.30E-02 5.33E-02 5.37E-02 Std Dev Un-Biased 5.67E-04 5.72E-04 5.19E-04 5.26E-04 5.73E-04 Ps90%/90% (+KTL) Un-Biased 5.44E-02 5.44E-02 5.45E-02 5.47E-02 5.52E-02 Ps90%/90% (-KTL) Un-Biased 5.13E-02 5.13E-02 5.16E-02 5.18E-02 5.21E-02 Specification MAX 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 145 Output Voltage Swing Low2 2 (V) @ VS=+/-15V IL=1mA TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX 1.20E-01 1.00E-01 8.00E-02 6.00E-02 4.00E-02 2.00E-02 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.68. Plot of Output Voltage Swing Low2 2 (V) @ VS=+/-15V IL=1mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 146 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.68. Raw data for Output Voltage Swing Low2 2 (V) @ VS=+/-15V IL=1mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Swing Low2 2 (V) @ VS=+/-15V IL=1mA Device 0 20 50 100 200 519 5.22E-02 5.24E-02 5.32E-02 5.27E-02 5.35E-02 520 5.33E-02 5.36E-02 5.39E-02 5.42E-02 5.48E-02 521 5.09E-02 5.09E-02 5.12E-02 5.16E-02 5.19E-02 522 5.23E-02 5.23E-02 5.27E-02 5.29E-02 5.34E-02 524 5.37E-02 5.35E-02 5.41E-02 5.44E-02 5.50E-02 536 5.32E-02 5.31E-02 5.30E-02 5.34E-02 5.38E-02 537 5.30E-02 5.28E-02 5.29E-02 5.34E-02 5.38E-02 538 5.30E-02 5.30E-02 5.29E-02 5.35E-02 5.36E-02 539 5.21E-02 5.23E-02 5.24E-02 5.27E-02 5.32E-02 542 5.23E-02 5.24E-02 5.23E-02 5.26E-02 5.31E-02 543 5.62E-02 5.57E-02 5.58E-02 5.57E-02 5.57E-02 544 5.28E-02 5.25E-02 5.25E-02 5.25E-02 5.27E-02 Biased Statistics Average Biased 5.25E-02 5.25E-02 5.30E-02 5.32E-02 5.37E-02 Std Dev Biased 1.12E-03 1.09E-03 1.17E-03 1.16E-03 1.26E-03 Ps90%/90% (+KTL) Biased 5.55E-02 5.55E-02 5.62E-02 5.64E-02 5.72E-02 Ps90%/90% (-KTL) Biased 4.94E-02 4.96E-02 4.98E-02 5.00E-02 5.03E-02 Un-Biased Statistics Average Un-Biased 5.27E-02 5.27E-02 5.27E-02 5.31E-02 5.35E-02 Std Dev Un-Biased 4.73E-04 3.67E-04 3.24E-04 4.29E-04 3.37E-04 Ps90%/90% (+KTL) Un-Biased 5.40E-02 5.37E-02 5.36E-02 5.43E-02 5.44E-02 Ps90%/90% (-KTL) Un-Biased 5.14E-02 5.17E-02 5.18E-02 5.19E-02 5.26E-02 Specification MAX 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 147 Output Voltage Swing Low2 3 (V) @ VS=+/-15V IL=1mA TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX 1.20E-01 1.00E-01 8.00E-02 6.00E-02 4.00E-02 2.00E-02 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.69. Plot of Output Voltage Swing Low2 3 (V) @ VS=+/-15V IL=1mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 148 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.69. Raw data for Output Voltage Swing Low2 3 (V) @ VS=+/-15V IL=1mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Swing Low2 3 (V) @ VS=+/-15V IL=1mA Device 0 20 50 100 200 519 5.23E-02 5.21E-02 5.32E-02 5.30E-02 5.32E-02 520 5.34E-02 5.35E-02 5.40E-02 5.41E-02 5.48E-02 521 5.02E-02 5.04E-02 5.07E-02 5.10E-02 5.13E-02 522 5.17E-02 5.16E-02 5.18E-02 5.21E-02 5.25E-02 524 5.30E-02 5.29E-02 5.34E-02 5.38E-02 5.42E-02 536 5.29E-02 5.26E-02 5.28E-02 5.32E-02 5.34E-02 537 5.20E-02 5.21E-02 5.24E-02 5.27E-02 5.31E-02 538 5.25E-02 5.23E-02 5.25E-02 5.28E-02 5.32E-02 539 5.17E-02 5.16E-02 5.19E-02 5.20E-02 5.23E-02 542 5.17E-02 5.16E-02 5.19E-02 5.21E-02 5.26E-02 543 5.57E-02 5.56E-02 5.54E-02 5.53E-02 5.55E-02 544 5.18E-02 5.16E-02 5.15E-02 5.16E-02 5.15E-02 Biased Statistics Average Biased 5.21E-02 5.21E-02 5.26E-02 5.28E-02 5.32E-02 Std Dev Biased 1.23E-03 1.21E-03 1.32E-03 1.28E-03 1.38E-03 Ps90%/90% (+KTL) Biased 5.55E-02 5.54E-02 5.62E-02 5.63E-02 5.70E-02 Ps90%/90% (-KTL) Biased 4.87E-02 4.88E-02 4.90E-02 4.93E-02 4.94E-02 Un-Biased Statistics Average Un-Biased 5.21E-02 5.20E-02 5.23E-02 5.26E-02 5.29E-02 Std Dev Un-Biased 5.24E-04 4.44E-04 4.13E-04 4.93E-04 4.47E-04 Ps90%/90% (+KTL) Un-Biased 5.36E-02 5.33E-02 5.34E-02 5.39E-02 5.41E-02 Ps90%/90% (-KTL) Un-Biased 5.07E-02 5.08E-02 5.12E-02 5.12E-02 5.17E-02 Specification MAX 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 149 Output Voltage Swing Low2 4 (V) @ VS=+/-15V IL=1mA TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX 1.20E-01 1.00E-01 8.00E-02 6.00E-02 4.00E-02 2.00E-02 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.70. Plot of Output Voltage Swing Low2 4 (V) @ VS=+/-15V IL=1mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 150 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.70. Raw data for Output Voltage Swing Low2 4 (V) @ VS=+/-15V IL=1mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Swing Low2 4 (V) @ VS=+/-15V IL=1mA Device 0 20 50 100 200 519 5.35E-02 5.35E-02 5.44E-02 5.41E-02 5.49E-02 520 5.29E-02 5.31E-02 5.33E-02 5.36E-02 5.41E-02 521 5.26E-02 5.28E-02 5.30E-02 5.33E-02 5.38E-02 522 5.23E-02 5.24E-02 5.28E-02 5.32E-02 5.37E-02 524 5.19E-02 5.16E-02 5.21E-02 5.23E-02 5.29E-02 536 5.37E-02 5.36E-02 5.37E-02 5.41E-02 5.44E-02 537 5.36E-02 5.34E-02 5.36E-02 5.39E-02 5.41E-02 538 5.34E-02 5.34E-02 5.34E-02 5.38E-02 5.42E-02 539 5.40E-02 5.40E-02 5.42E-02 5.46E-02 5.48E-02 542 5.24E-02 5.23E-02 5.24E-02 5.30E-02 5.33E-02 543 5.25E-02 5.20E-02 5.19E-02 5.20E-02 5.21E-02 544 5.03E-02 5.01E-02 5.03E-02 5.02E-02 5.03E-02 Biased Statistics Average Biased 5.26E-02 5.27E-02 5.31E-02 5.33E-02 5.39E-02 Std Dev Biased 5.96E-04 7.41E-04 8.40E-04 6.61E-04 7.21E-04 Ps90%/90% (+KTL) Biased 5.43E-02 5.47E-02 5.54E-02 5.51E-02 5.58E-02 Ps90%/90% (-KTL) Biased 5.10E-02 5.07E-02 5.08E-02 5.15E-02 5.19E-02 Un-Biased Statistics Average Un-Biased 5.34E-02 5.33E-02 5.35E-02 5.39E-02 5.42E-02 Std Dev Un-Biased 6.16E-04 6.31E-04 6.44E-04 5.89E-04 5.48E-04 Ps90%/90% (+KTL) Un-Biased 5.51E-02 5.51E-02 5.52E-02 5.55E-02 5.57E-02 Ps90%/90% (-KTL) Un-Biased 5.17E-02 5.16E-02 5.17E-02 5.23E-02 5.27E-02 Specification MAX 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 151 Output Voltage Swing Low3 1 (V) @ VS=+/-15V IL=10mA TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX 6.00E-01 5.00E-01 4.00E-01 3.00E-01 2.00E-01 1.00E-01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.71. Plot of Output Voltage Swing Low3 1 (V) @ VS=+/-15V IL=10mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 152 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.71. Raw data for Output Voltage Swing Low3 1 (V) @ VS=+/-15V IL=10mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Swing Low3 1 (V) @ VS=+/-15V IL=10mA Device 0 20 50 100 200 519 2.19E-01 2.18E-01 2.21E-01 2.19E-01 2.20E-01 520 2.17E-01 2.16E-01 2.17E-01 2.17E-01 2.18E-01 521 2.14E-01 2.14E-01 2.14E-01 2.15E-01 2.15E-01 522 2.17E-01 2.16E-01 2.16E-01 2.17E-01 2.17E-01 524 2.18E-01 2.17E-01 2.17E-01 2.18E-01 2.19E-01 536 2.19E-01 2.19E-01 2.19E-01 2.19E-01 2.20E-01 537 2.18E-01 2.17E-01 2.17E-01 2.18E-01 2.18E-01 538 2.18E-01 2.18E-01 2.18E-01 2.19E-01 2.19E-01 539 2.20E-01 2.19E-01 2.20E-01 2.20E-01 2.21E-01 542 2.16E-01 2.15E-01 2.16E-01 2.16E-01 2.17E-01 543 2.14E-01 2.12E-01 2.12E-01 2.12E-01 2.12E-01 544 2.09E-01 2.09E-01 2.09E-01 2.09E-01 2.09E-01 Biased Statistics Average Biased 2.17E-01 2.16E-01 2.17E-01 2.17E-01 2.18E-01 Std Dev Biased 1.90E-03 1.40E-03 2.49E-03 1.57E-03 2.01E-03 Ps90%/90% (+KTL) Biased 2.22E-01 2.20E-01 2.24E-01 2.21E-01 2.23E-01 Ps90%/90% (-KTL) Biased 2.12E-01 2.12E-01 2.10E-01 2.13E-01 2.12E-01 Un-Biased Statistics Average Un-Biased 2.18E-01 2.17E-01 2.18E-01 2.18E-01 2.19E-01 Std Dev Un-Biased 1.59E-03 1.56E-03 1.53E-03 1.57E-03 1.58E-03 Ps90%/90% (+KTL) Un-Biased 2.23E-01 2.22E-01 2.22E-01 2.23E-01 2.23E-01 Ps90%/90% (-KTL) Un-Biased 2.14E-01 2.13E-01 2.14E-01 2.14E-01 2.15E-01 Specification MAX 5.00E-01 5.00E-01 5.00E-01 5.00E-01 5.00E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 153 Output Voltage Swing Low3 2 (V) @ VS=+/-15V IL=10mA TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX 6.00E-01 5.00E-01 4.00E-01 3.00E-01 2.00E-01 1.00E-01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.72. Plot of Output Voltage Swing Low3 2 (V) @ VS=+/-15V IL=10mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 154 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.72. Raw data for Output Voltage Swing Low3 2 (V) @ VS=+/-15V IL=10mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Swing Low3 2 (V) @ VS=+/-15V IL=10mA Device 0 20 50 100 200 519 2.19E-01 2.18E-01 2.21E-01 2.19E-01 2.20E-01 520 2.21E-01 2.21E-01 2.21E-01 2.21E-01 2.23E-01 521 2.14E-01 2.13E-01 2.14E-01 2.14E-01 2.15E-01 522 2.15E-01 2.14E-01 2.14E-01 2.15E-01 2.16E-01 524 2.19E-01 2.18E-01 2.19E-01 2.20E-01 2.21E-01 536 2.20E-01 2.20E-01 2.20E-01 2.21E-01 2.21E-01 537 2.19E-01 2.18E-01 2.19E-01 2.19E-01 2.20E-01 538 2.17E-01 2.17E-01 2.17E-01 2.17E-01 2.18E-01 539 2.18E-01 2.18E-01 2.18E-01 2.18E-01 2.19E-01 542 2.18E-01 2.17E-01 2.18E-01 2.18E-01 2.19E-01 543 2.22E-01 2.21E-01 2.20E-01 2.21E-01 2.21E-01 544 2.14E-01 2.14E-01 2.14E-01 2.14E-01 2.15E-01 Biased Statistics Average Biased 2.18E-01 2.17E-01 2.18E-01 2.18E-01 2.19E-01 Std Dev Biased 3.11E-03 3.06E-03 3.35E-03 3.02E-03 3.33E-03 Ps90%/90% (+KTL) Biased 2.26E-01 2.25E-01 2.27E-01 2.26E-01 2.28E-01 Ps90%/90% (-KTL) Biased 2.09E-01 2.08E-01 2.08E-01 2.10E-01 2.10E-01 Un-Biased Statistics Average Un-Biased 2.19E-01 2.18E-01 2.18E-01 2.19E-01 2.19E-01 Std Dev Un-Biased 1.31E-03 1.36E-03 1.29E-03 1.31E-03 1.23E-03 Ps90%/90% (+KTL) Un-Biased 2.22E-01 2.22E-01 2.22E-01 2.22E-01 2.23E-01 Ps90%/90% (-KTL) Un-Biased 2.15E-01 2.14E-01 2.15E-01 2.15E-01 2.16E-01 Specification MAX 5.00E-01 5.00E-01 5.00E-01 5.00E-01 5.00E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 155 Output Voltage Swing Low3 3 (V) @ VS=+/-15V IL=10mA TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX 6.00E-01 5.00E-01 4.00E-01 3.00E-01 2.00E-01 1.00E-01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.73. Plot of Output Voltage Swing Low3 3 (V) @ VS=+/-15V IL=10mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 156 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.73. Raw data for Output Voltage Swing Low3 3 (V) @ VS=+/-15V IL=10mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Swing Low3 3 (V) @ VS=+/-15V IL=10mA Device 0 20 50 100 200 519 2.17E-01 2.16E-01 2.19E-01 2.18E-01 2.19E-01 520 2.19E-01 2.19E-01 2.19E-01 2.20E-01 2.21E-01 521 2.12E-01 2.11E-01 2.11E-01 2.12E-01 2.13E-01 522 2.12E-01 2.11E-01 2.12E-01 2.12E-01 2.13E-01 524 2.17E-01 2.16E-01 2.16E-01 2.17E-01 2.18E-01 536 2.19E-01 2.19E-01 2.19E-01 2.19E-01 2.20E-01 537 2.16E-01 2.16E-01 2.16E-01 2.16E-01 2.17E-01 538 2.14E-01 2.14E-01 2.14E-01 2.15E-01 2.15E-01 539 2.16E-01 2.15E-01 2.16E-01 2.16E-01 2.17E-01 542 2.15E-01 2.15E-01 2.15E-01 2.15E-01 2.17E-01 543 2.20E-01 2.19E-01 2.19E-01 2.19E-01 2.19E-01 544 2.12E-01 2.11E-01 2.12E-01 2.12E-01 2.12E-01 Biased Statistics Average Biased 2.15E-01 2.15E-01 2.15E-01 2.16E-01 2.17E-01 Std Dev Biased 3.29E-03 3.29E-03 3.80E-03 3.57E-03 3.72E-03 Ps90%/90% (+KTL) Biased 2.24E-01 2.24E-01 2.26E-01 2.25E-01 2.27E-01 Ps90%/90% (-KTL) Biased 2.06E-01 2.06E-01 2.05E-01 2.06E-01 2.06E-01 Un-Biased Statistics Average Un-Biased 2.16E-01 2.16E-01 2.16E-01 2.16E-01 2.17E-01 Std Dev Un-Biased 1.82E-03 1.92E-03 1.62E-03 1.50E-03 1.63E-03 Ps90%/90% (+KTL) Un-Biased 2.21E-01 2.21E-01 2.20E-01 2.20E-01 2.22E-01 Ps90%/90% (-KTL) Un-Biased 2.11E-01 2.10E-01 2.11E-01 2.12E-01 2.13E-01 Specification MAX 5.00E-01 5.00E-01 5.00E-01 5.00E-01 5.00E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 157 Output Voltage Swing Low3 4 (V) @ VS=+/-15V IL=10mA TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX 6.00E-01 5.00E-01 4.00E-01 3.00E-01 2.00E-01 1.00E-01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.74. Plot of Output Voltage Swing Low3 4 (V) @ VS=+/-15V IL=10mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 158 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.74. Raw data for Output Voltage Swing Low3 4 (V) @ VS=+/-15V IL=10mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Swing Low3 4 (V) @ VS=+/-15V IL=10mA Device 0 20 50 100 200 519 2.21E-01 2.20E-01 2.23E-01 2.22E-01 2.23E-01 520 2.19E-01 2.19E-01 2.20E-01 2.20E-01 2.21E-01 521 2.18E-01 2.18E-01 2.17E-01 2.18E-01 2.19E-01 522 2.19E-01 2.18E-01 2.19E-01 2.19E-01 2.20E-01 524 2.19E-01 2.18E-01 2.18E-01 2.19E-01 2.20E-01 536 2.21E-01 2.21E-01 2.21E-01 2.21E-01 2.22E-01 537 2.20E-01 2.19E-01 2.20E-01 2.21E-01 2.21E-01 538 2.21E-01 2.21E-01 2.21E-01 2.21E-01 2.22E-01 539 2.22E-01 2.22E-01 2.22E-01 2.23E-01 2.23E-01 542 2.18E-01 2.18E-01 2.18E-01 2.18E-01 2.19E-01 543 2.16E-01 2.15E-01 2.15E-01 2.15E-01 2.15E-01 544 2.12E-01 2.12E-01 2.11E-01 2.12E-01 2.12E-01 Biased Statistics Average Biased 2.19E-01 2.19E-01 2.19E-01 2.20E-01 2.21E-01 Std Dev Biased 1.36E-03 1.20E-03 2.37E-03 1.38E-03 1.55E-03 Ps90%/90% (+KTL) Biased 2.23E-01 2.22E-01 2.26E-01 2.23E-01 2.25E-01 Ps90%/90% (-KTL) Biased 2.16E-01 2.15E-01 2.13E-01 2.16E-01 2.16E-01 Un-Biased Statistics Average Un-Biased 2.21E-01 2.20E-01 2.20E-01 2.21E-01 2.21E-01 Std Dev Un-Biased 1.71E-03 1.80E-03 1.60E-03 1.56E-03 1.64E-03 Ps90%/90% (+KTL) Un-Biased 2.25E-01 2.25E-01 2.25E-01 2.25E-01 2.26E-01 Ps90%/90% (-KTL) Un-Biased 2.16E-01 2.15E-01 2.16E-01 2.17E-01 2.17E-01 Specification MAX 5.00E-01 5.00E-01 5.00E-01 5.00E-01 5.00E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 159 Large Signal Voltage Gain1 1 (V/mV) @ VO=+/-14.5V, RL=10kΩ TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 5.00E+03 4.50E+03 4.00E+03 3.50E+03 3.00E+03 2.50E+03 2.00E+03 1.50E+03 1.00E+03 5.00E+02 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.75. Plot of Large Signal Voltage Gain1 1 (V/mV) @ VO=+/-14.5V, RL=10kΩ versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 160 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.75. Raw data for Large Signal Voltage Gain1 1 (V/mV) @ VO=+/-14.5V, RL=10kΩ versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Large Signal Voltage Gain1 1 (V/mV) @ VO=+/-14.5V, RL=10kΩ Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 4.33E+03 4.89E+03 3.86E+03 6.05E+03 3.51E+03 3.52E+03 3.45E+03 5.22E+03 3.19E+03 4.13E+03 5.54E+03 4.52E+03 Total 20 3.80E+03 4.62E+03 4.52E+03 5.59E+03 3.42E+03 3.49E+03 3.37E+03 4.96E+03 3.26E+03 4.16E+03 5.65E+03 4.57E+03 Dose (krad(Si)) 50 100 3.86E+03 3.78E+03 4.54E+03 4.39E+03 3.79E+03 4.18E+03 5.33E+03 4.90E+03 3.12E+03 3.18E+03 3.25E+03 3.22E+03 3.25E+03 2.94E+03 4.71E+03 4.66E+03 3.13E+03 3.15E+03 4.11E+03 3.95E+03 5.64E+03 5.64E+03 4.56E+03 4.62E+03 200 3.64E+03 4.03E+03 4.06E+03 4.63E+03 2.99E+03 3.15E+03 3.05E+03 4.31E+03 2.83E+03 3.52E+03 5.47E+03 4.51E+03 4.53E+03 9.98E+02 7.26E+03 1.79E+03 4.39E+03 8.37E+02 6.68E+03 2.09E+03 4.13E+03 8.40E+02 6.43E+03 1.83E+03 4.09E+03 6.47E+02 5.86E+03 2.31E+03 3.87E+03 6.06E+02 5.53E+03 2.21E+03 3.90E+03 8.14E+02 6.13E+03 1.67E+03 1.00E+03 PASS 3.85E+03 7.15E+02 5.81E+03 1.89E+03 5.00E+02 PASS 3.69E+03 6.90E+02 5.58E+03 1.80E+03 5.00E+02 PASS 3.59E+03 7.13E+02 5.54E+03 1.63E+03 5.00E+02 PASS 3.37E+03 5.82E+02 4.97E+03 1.78E+03 5.00E+02 PASS An ISO 9001:2008 and DSCC Certified Company 161 Large Signal Voltage Gain1 2 (V/mV) @ VO=+/-14.5V, RL=10kΩ TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 7.00E+03 6.00E+03 5.00E+03 4.00E+03 3.00E+03 2.00E+03 1.00E+03 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.76. Plot of Large Signal Voltage Gain1 2 (V/mV) @ VO=+/-14.5V, RL=10kΩ versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 162 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.76. Raw data for Large Signal Voltage Gain1 2 (V/mV) @ VO=+/-14.5V, RL=10kΩ versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Large Signal Voltage Gain1 2 (V/mV) @ VO=+/-14.5V, RL=10kΩ Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 6.56E+03 6.88E+03 4.92E+03 4.34E+03 8.63E+03 6.61E+03 4.69E+03 5.92E+03 6.98E+03 6.65E+03 6.24E+03 5.53E+03 Total 20 6.55E+03 6.51E+03 4.59E+03 4.16E+03 8.61E+03 6.42E+03 3.96E+03 5.93E+03 6.90E+03 6.91E+03 6.07E+03 6.40E+03 Dose (krad(Si)) 50 100 6.23E+03 5.90E+03 6.13E+03 5.91E+03 4.77E+03 4.15E+03 3.97E+03 3.84E+03 8.09E+03 7.05E+03 5.97E+03 5.49E+03 3.97E+03 4.08E+03 5.22E+03 5.00E+03 5.95E+03 5.93E+03 5.30E+03 5.82E+03 6.24E+03 6.05E+03 5.65E+03 5.61E+03 200 5.41E+03 5.64E+03 4.03E+03 3.91E+03 6.73E+03 5.37E+03 4.34E+03 5.06E+03 5.27E+03 5.02E+03 6.28E+03 5.44E+03 6.26E+03 1.70E+03 1.09E+04 1.60E+03 6.08E+03 1.78E+03 1.10E+04 1.19E+03 5.84E+03 1.58E+03 1.02E+04 1.51E+03 5.37E+03 1.35E+03 9.06E+03 1.68E+03 5.15E+03 1.18E+03 8.38E+03 1.91E+03 6.17E+03 9.15E+02 8.68E+03 3.66E+03 1.00E+03 PASS 6.02E+03 1.22E+03 9.38E+03 2.67E+03 5.00E+02 PASS 5.28E+03 8.11E+02 7.51E+03 3.06E+03 5.00E+02 PASS 5.27E+03 7.53E+02 7.33E+03 3.20E+03 5.00E+02 PASS 5.01E+03 4.04E+02 6.12E+03 3.91E+03 5.00E+02 PASS An ISO 9001:2008 and DSCC Certified Company 163 Large Signal Voltage Gain1 3 (V/mV) @ VO=+/-14.5V, RL=10kΩ TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 6.00E+03 5.00E+03 4.00E+03 3.00E+03 2.00E+03 1.00E+03 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.77. Plot of Large Signal Voltage Gain1 3 (V/mV) @ VO=+/-14.5V, RL=10kΩ versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 164 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.77. Raw data for Large Signal Voltage Gain1 3 (V/mV) @ VO=+/-14.5V, RL=10kΩ versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Large Signal Voltage Gain1 3 (V/mV) @ VO=+/-14.5V, RL=10kΩ Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 4.43E+03 4.08E+03 5.42E+03 4.16E+03 3.74E+03 5.30E+03 6.27E+03 5.90E+03 4.27E+03 6.43E+03 6.02E+03 5.29E+03 Total 20 4.16E+03 3.85E+03 5.16E+03 3.96E+03 3.80E+03 5.18E+03 6.38E+03 5.73E+03 4.12E+03 6.43E+03 6.16E+03 5.36E+03 Dose (krad(Si)) 50 100 3.93E+03 3.94E+03 3.73E+03 3.70E+03 4.89E+03 4.83E+03 3.78E+03 3.74E+03 3.51E+03 3.43E+03 5.10E+03 4.62E+03 5.51E+03 5.44E+03 5.87E+03 4.92E+03 3.82E+03 4.04E+03 5.23E+03 6.11E+03 6.17E+03 6.32E+03 5.07E+03 5.42E+03 200 3.63E+03 3.55E+03 4.54E+03 3.46E+03 3.21E+03 4.97E+03 5.60E+03 4.92E+03 3.50E+03 5.30E+03 6.12E+03 5.27E+03 4.37E+03 6.38E+02 6.12E+03 2.62E+03 4.19E+03 5.62E+02 5.73E+03 2.65E+03 3.97E+03 5.38E+02 5.44E+03 2.49E+03 3.93E+03 5.39E+02 5.40E+03 2.45E+03 3.68E+03 5.09E+02 5.07E+03 2.28E+03 5.63E+03 8.76E+02 8.04E+03 3.23E+03 1.00E+03 PASS 5.57E+03 9.61E+02 8.20E+03 2.93E+03 5.00E+02 PASS 5.10E+03 7.76E+02 7.23E+03 2.98E+03 5.00E+02 PASS 5.02E+03 7.92E+02 7.20E+03 2.85E+03 5.00E+02 PASS 4.86E+03 8.07E+02 7.07E+03 2.64E+03 5.00E+02 PASS An ISO 9001:2008 and DSCC Certified Company 165 Large Signal Voltage Gain1 4 (V/mV) @ VO=+/-14.5V, RL=10kΩ TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 6.00E+03 5.00E+03 4.00E+03 3.00E+03 2.00E+03 1.00E+03 0.00E+00 -1.00E+03 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.78. Plot of Large Signal Voltage Gain1 4 (V/mV) @ VO=+/-14.5V, RL=10kΩ versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 166 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.78. Raw data for Large Signal Voltage Gain1 4 (V/mV) @ VO=+/-14.5V, RL=10kΩ versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Large Signal Voltage Gain1 4 (V/mV) @ VO=+/-14.5V, RL=10kΩ Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 3.89E+03 6.19E+03 5.48E+03 4.10E+03 3.96E+03 5.68E+03 4.24E+03 4.25E+03 8.12E+03 4.32E+03 6.58E+03 5.74E+03 Total 20 4.40E+03 5.76E+03 5.23E+03 6.35E+03 3.89E+03 5.50E+03 4.15E+03 4.21E+03 8.76E+03 4.26E+03 6.73E+03 5.93E+03 Dose (krad(Si)) 50 100 4.26E+03 5.30E+03 5.45E+03 5.74E+03 5.60E+03 4.80E+03 6.09E+03 5.91E+03 3.60E+03 3.64E+03 5.17E+03 5.53E+03 4.25E+03 3.96E+03 4.03E+03 3.79E+03 8.19E+03 7.56E+03 4.59E+03 3.89E+03 6.76E+03 6.94E+03 4.62E+03 5.27E+03 200 4.12E+03 4.95E+03 4.66E+03 5.30E+03 3.36E+03 4.53E+03 3.54E+03 3.86E+03 6.82E+03 3.71E+03 6.73E+03 5.68E+03 4.72E+03 1.05E+03 7.59E+03 1.85E+03 5.13E+03 9.94E+02 7.85E+03 2.40E+03 5.00E+03 1.03E+03 7.83E+03 2.17E+03 5.08E+03 9.14E+02 7.58E+03 2.57E+03 4.48E+03 7.61E+02 6.56E+03 2.39E+03 5.32E+03 1.68E+03 9.93E+03 7.17E+02 1.00E+03 PASS 5.37E+03 1.97E+03 1.08E+04 -3.93E+01 5.00E+02 PASS 5.24E+03 1.70E+03 9.90E+03 5.82E+02 5.00E+02 PASS 4.95E+03 1.63E+03 9.41E+03 4.79E+02 5.00E+02 PASS 4.49E+03 1.36E+03 8.21E+03 7.74E+02 5.00E+02 PASS An ISO 9001:2008 and DSCC Certified Company 167 Large Signal Voltage Gain2 1 (V/mV) @ VO=+/-10V, RL=2kΩ TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 1.80E+03 1.60E+03 1.40E+03 1.20E+03 1.00E+03 8.00E+02 6.00E+02 4.00E+02 2.00E+02 0.00E+00 -2.00E+02 -4.00E+02 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.79. Plot of Large Signal Voltage Gain2 1 (V/mV) @ VO=+/-10V, RL=2kΩ versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 168 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.79. Raw data for Large Signal Voltage Gain2 1 (V/mV) @ VO=+/-10V, RL=2kΩ versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Large Signal Voltage Gain2 1 (V/mV) @ VO=+/-10V, RL=2kΩ Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 1.15E+03 1.47E+03 1.49E+03 2.58E+03 1.03E+03 1.03E+03 1.02E+03 2.33E+03 9.87E+02 1.23E+03 2.23E+03 2.03E+03 Total 20 1.09E+03 1.41E+03 1.31E+03 2.30E+03 1.01E+03 1.03E+03 9.99E+02 2.29E+03 9.80E+02 1.20E+03 2.27E+03 2.03E+03 Dose (krad(Si)) 50 100 1.04E+03 1.06E+03 1.41E+03 1.33E+03 1.32E+03 1.34E+03 2.25E+03 2.16E+03 9.65E+02 9.41E+02 9.81E+02 9.70E+02 9.79E+02 9.86E+02 2.18E+03 2.10E+03 9.43E+02 9.35E+02 1.14E+03 1.14E+03 2.26E+03 2.28E+03 2.04E+03 2.07E+03 200 1.02E+03 1.25E+03 1.27E+03 2.06E+03 9.16E+02 9.35E+02 9.20E+02 1.89E+03 9.06E+02 1.07E+03 2.27E+03 2.10E+03 1.54E+03 6.12E+02 3.22E+03 -1.37E+02 1.43E+03 5.15E+02 2.84E+03 1.45E+01 1.39E+03 5.12E+02 2.80E+03 -9.72E+00 1.37E+03 4.76E+02 2.67E+03 5.96E+01 1.31E+03 4.50E+02 2.54E+03 7.22E+01 1.32E+03 5.73E+02 2.89E+03 -2.54E+02 5.00E+02 PASS 1.30E+03 5.62E+02 2.84E+03 -2.39E+02 2.50E+02 PASS 1.24E+03 5.28E+02 2.69E+03 -2.02E+02 2.50E+02 PASS 1.23E+03 4.95E+02 2.58E+03 -1.30E+02 2.50E+02 PASS 1.14E+03 4.22E+02 2.30E+03 -1.31E+01 2.50E+02 PASS An ISO 9001:2008 and DSCC Certified Company 169 Large Signal Voltage Gain2 2 (V/mV) @ VO=+/-10V, RL=2kΩ TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 2.50E+03 2.00E+03 1.50E+03 1.00E+03 5.00E+02 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.80. Plot of Large Signal Voltage Gain2 2 (V/mV) @ VO=+/-10V, RL=2kΩ versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 170 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.80. Raw data for Large Signal Voltage Gain2 2 (V/mV) @ VO=+/-10V, RL=2kΩ versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Large Signal Voltage Gain2 2 (V/mV) @ VO=+/-10V, RL=2kΩ Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 2.56E+03 2.55E+03 1.76E+03 1.42E+03 3.28E+03 2.45E+03 1.50E+03 2.06E+03 2.34E+03 2.37E+03 2.31E+03 2.00E+03 Total 20 2.42E+03 2.28E+03 1.61E+03 1.37E+03 2.91E+03 2.30E+03 1.47E+03 2.06E+03 2.31E+03 2.11E+03 2.29E+03 2.08E+03 Dose (krad(Si)) 50 100 2.25E+03 2.16E+03 2.23E+03 2.17E+03 1.60E+03 1.53E+03 1.33E+03 1.32E+03 2.81E+03 2.77E+03 2.32E+03 2.16E+03 1.37E+03 1.34E+03 2.00E+03 1.79E+03 2.16E+03 2.07E+03 2.32E+03 2.13E+03 2.32E+03 2.30E+03 2.12E+03 2.07E+03 200 2.02E+03 1.96E+03 1.47E+03 1.27E+03 2.33E+03 2.00E+03 1.28E+03 1.84E+03 1.88E+03 1.94E+03 2.31E+03 2.09E+03 2.31E+03 7.38E+02 4.34E+03 2.92E+02 2.12E+03 6.24E+02 3.83E+03 4.05E+02 2.05E+03 5.86E+02 3.65E+03 4.37E+02 1.99E+03 5.75E+02 3.56E+03 4.12E+02 1.81E+03 4.32E+02 3.00E+03 6.24E+02 2.14E+03 3.88E+02 3.21E+03 1.08E+03 5.00E+02 PASS 2.05E+03 3.44E+02 2.99E+03 1.11E+03 2.50E+02 PASS 2.03E+03 3.95E+02 3.12E+03 9.50E+02 2.50E+02 PASS 1.90E+03 3.44E+02 2.84E+03 9.55E+02 2.50E+02 PASS 1.79E+03 2.90E+02 2.58E+03 9.94E+02 2.50E+02 PASS An ISO 9001:2008 and DSCC Certified Company 171 Large Signal Voltage Gain2 3 (V/mV) @ VO=+/-10V, RL=2kΩ TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 2.50E+03 2.00E+03 1.50E+03 1.00E+03 5.00E+02 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.81. Plot of Large Signal Voltage Gain2 3 (V/mV) @ VO=+/-10V, RL=2kΩ versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 172 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.81. Raw data for Large Signal Voltage Gain2 3 (V/mV) @ VO=+/-10V, RL=2kΩ versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Large Signal Voltage Gain2 3 (V/mV) @ VO=+/-10V, RL=2kΩ Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 1.17E+03 1.09E+03 2.10E+03 1.12E+03 1.09E+03 1.98E+03 2.36E+03 2.31E+03 1.14E+03 2.45E+03 2.36E+03 1.60E+03 Total 20 1.11E+03 1.04E+03 2.00E+03 1.07E+03 1.08E+03 1.87E+03 2.31E+03 2.22E+03 1.13E+03 2.34E+03 2.41E+03 1.57E+03 Dose (krad(Si)) 50 100 1.10E+03 1.12E+03 1.01E+03 9.77E+02 1.87E+03 1.84E+03 1.04E+03 1.03E+03 1.03E+03 9.90E+02 1.92E+03 1.83E+03 2.21E+03 2.23E+03 2.24E+03 2.04E+03 1.14E+03 1.06E+03 2.27E+03 2.10E+03 2.35E+03 2.38E+03 1.51E+03 1.54E+03 200 1.07E+03 9.49E+02 1.69E+03 9.99E+02 9.58E+02 1.71E+03 2.02E+03 1.90E+03 1.04E+03 2.03E+03 2.40E+03 1.51E+03 1.31E+03 4.38E+02 2.52E+03 1.11E+02 1.26E+03 4.16E+02 2.40E+03 1.20E+02 1.21E+03 3.73E+02 2.23E+03 1.87E+02 1.19E+03 3.67E+02 2.19E+03 1.84E+02 1.13E+03 3.17E+02 2.00E+03 2.64E+02 2.05E+03 5.37E+02 3.52E+03 5.76E+02 5.00E+02 PASS 1.97E+03 5.07E+02 3.36E+03 5.82E+02 2.50E+02 PASS 1.96E+03 4.76E+02 3.26E+03 6.50E+02 2.50E+02 PASS 1.85E+03 4.63E+02 3.12E+03 5.81E+02 2.50E+02 PASS 1.74E+03 4.16E+02 2.88E+03 6.02E+02 2.50E+02 PASS An ISO 9001:2008 and DSCC Certified Company 173 Large Signal Voltage Gain2 4 (V/mV) @ VO=+/-10V, RL=2kΩ TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 2.00E+03 1.50E+03 1.00E+03 5.00E+02 0.00E+00 -5.00E+02 -1.00E+03 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.82. Plot of Large Signal Voltage Gain2 4 (V/mV) @ VO=+/-10V, RL=2kΩ versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 174 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.82. Raw data for Large Signal Voltage Gain2 4 (V/mV) @ VO=+/-10V, RL=2kΩ versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Large Signal Voltage Gain2 4 (V/mV) @ VO=+/-10V, RL=2kΩ Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 1.18E+03 2.41E+03 1.62E+03 2.34E+03 1.07E+03 2.12E+03 1.10E+03 1.12E+03 3.19E+03 1.20E+03 2.57E+03 2.21E+03 Total 20 1.13E+03 2.23E+03 1.50E+03 2.31E+03 1.05E+03 2.14E+03 1.08E+03 1.09E+03 3.13E+03 1.20E+03 2.46E+03 2.25E+03 Dose (krad(Si)) 50 100 1.10E+03 1.08E+03 2.06E+03 2.04E+03 1.45E+03 1.45E+03 2.24E+03 2.01E+03 9.89E+02 9.63E+02 2.09E+03 2.01E+03 1.09E+03 1.05E+03 1.05E+03 1.01E+03 2.91E+03 2.72E+03 1.16E+03 1.16E+03 2.46E+03 2.52E+03 2.32E+03 2.43E+03 200 1.02E+03 1.95E+03 1.36E+03 1.93E+03 9.30E+02 1.79E+03 9.89E+02 9.63E+02 2.63E+03 1.07E+03 2.48E+03 2.41E+03 1.72E+03 6.29E+02 3.45E+03 -2.13E+00 1.64E+03 5.96E+02 3.28E+03 9.60E+00 1.57E+03 5.62E+02 3.11E+03 2.59E+01 1.51E+03 5.04E+02 2.89E+03 1.25E+02 1.44E+03 4.86E+02 2.77E+03 1.05E+02 1.74E+03 9.15E+02 4.25E+03 -7.64E+02 5.00E+02 PASS 1.73E+03 9.03E+02 4.20E+03 -7.48E+02 2.50E+02 PASS 1.66E+03 8.22E+02 3.91E+03 -5.96E+02 2.50E+02 PASS 1.59E+03 7.53E+02 3.65E+03 -4.76E+02 2.50E+02 PASS 1.49E+03 7.23E+02 3.47E+03 -4.93E+02 2.50E+02 PASS An ISO 9001:2008 and DSCC Certified Company 175 Common Mode Rejection Ratio1 1 (dB) @ VS=+/-15V, VCM=+/-15V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.83. Plot of Common Mode Rejection Ratio1 1 (dB) @ VS=+/-15V, VCM=+/-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 176 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.83. Raw data for Common Mode Rejection Ratio1 1 (dB) @ VS=+/-15V, VCM=+/-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Common Mode Rejection Ratio1 1 (dB) @ VS=+/-15V, VCM=+/-15V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 1.04E+02 1.05E+02 1.01E+02 9.90E+01 9.83E+01 1.05E+02 9.76E+01 1.08E+02 1.01E+02 1.05E+02 9.78E+01 9.67E+01 Total 20 1.04E+02 1.05E+02 1.02E+02 9.88E+01 9.84E+01 1.04E+02 9.76E+01 1.08E+02 1.01E+02 1.04E+02 9.78E+01 9.67E+01 Dose (krad(Si)) 50 100 1.04E+02 1.04E+02 1.05E+02 1.05E+02 1.02E+02 1.02E+02 9.86E+01 9.84E+01 9.85E+01 9.85E+01 1.04E+02 1.04E+02 9.76E+01 9.75E+01 1.07E+02 1.07E+02 1.01E+02 1.00E+02 1.04E+02 1.04E+02 9.78E+01 9.78E+01 9.67E+01 9.67E+01 200 1.04E+02 1.04E+02 1.01E+02 9.81E+01 9.82E+01 1.04E+02 9.74E+01 1.06E+02 1.00E+02 1.03E+02 9.78E+01 9.67E+01 1.01E+02 2.88E+00 1.09E+02 9.36E+01 1.02E+02 2.92E+00 1.10E+02 9.35E+01 1.01E+02 2.89E+00 1.09E+02 9.36E+01 1.01E+02 2.89E+00 1.09E+02 9.34E+01 1.01E+02 2.79E+00 1.09E+02 9.34E+01 1.03E+02 3.92E+00 1.14E+02 9.23E+01 9.00E+01 PASS 1.03E+02 4.02E+00 1.14E+02 9.20E+01 8.60E+01 PASS 1.03E+02 3.81E+00 1.13E+02 9.24E+01 8.60E+01 PASS 1.03E+02 3.71E+00 1.13E+02 9.24E+01 8.60E+01 PASS 1.02E+02 3.52E+00 1.12E+02 9.27E+01 8.60E+01 PASS An ISO 9001:2008 and DSCC Certified Company 177 Common Mode Rejection Ratio1 2 (dB) @ VS=+/-15V, VCM=+/-15V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN 1.60E+02 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.84. Plot of Common Mode Rejection Ratio1 2 (dB) @ VS=+/-15V, VCM=+/-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 178 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.84. Raw data for Common Mode Rejection Ratio1 2 (dB) @ VS=+/-15V, VCM=+/-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Common Mode Rejection Ratio1 2 (dB) @ VS=+/-15V, VCM=+/-15V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 1.01E+02 1.13E+02 9.87E+01 9.80E+01 1.18E+02 1.25E+02 9.87E+01 9.84E+01 9.83E+01 9.99E+01 1.03E+02 1.05E+02 Total 20 1.00E+02 1.12E+02 9.89E+01 9.80E+01 1.14E+02 1.24E+02 9.83E+01 9.83E+01 9.84E+01 9.97E+01 1.03E+02 1.05E+02 Dose (krad(Si)) 50 100 1.00E+02 1.00E+02 1.11E+02 1.11E+02 9.89E+01 9.89E+01 9.79E+01 9.78E+01 1.15E+02 1.17E+02 1.22E+02 1.21E+02 9.82E+01 9.81E+01 9.83E+01 9.82E+01 9.82E+01 9.80E+01 9.96E+01 9.96E+01 1.03E+02 1.03E+02 1.05E+02 1.05E+02 200 1.00E+02 1.10E+02 9.87E+01 9.77E+01 1.20E+02 1.19E+02 9.81E+01 9.80E+01 9.79E+01 9.95E+01 1.03E+02 1.05E+02 1.06E+02 9.09E+00 1.31E+02 8.08E+01 1.05E+02 7.77E+00 1.26E+02 8.34E+01 1.05E+02 8.04E+00 1.27E+02 8.28E+01 1.05E+02 8.60E+00 1.29E+02 8.15E+01 1.05E+02 9.67E+00 1.32E+02 7.89E+01 1.04E+02 1.16E+01 1.36E+02 7.22E+01 9.00E+01 PASS 1.04E+02 1.15E+01 1.35E+02 7.24E+01 8.60E+01 PASS 1.03E+02 1.05E+01 1.32E+02 7.46E+01 8.60E+01 PASS 1.03E+02 1.00E+01 1.30E+02 7.55E+01 8.60E+01 PASS 1.03E+02 9.34E+00 1.28E+02 7.69E+01 8.60E+01 PASS An ISO 9001:2008 and DSCC Certified Company 179 Common Mode Rejection Ratio1 3 (dB) @ VS=+/-15V, VCM=+/-15V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN 1.80E+02 1.60E+02 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.85. Plot of Common Mode Rejection Ratio1 3 (dB) @ VS=+/-15V, VCM=+/-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 180 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.85. Raw data for Common Mode Rejection Ratio1 3 (dB) @ VS=+/-15V, VCM=+/-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Common Mode Rejection Ratio1 3 (dB) @ VS=+/-15V, VCM=+/-15V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 1.02E+02 9.68E+01 9.80E+01 1.06E+02 1.24E+02 9.99E+01 1.07E+02 9.95E+01 1.01E+02 1.24E+02 1.08E+02 1.02E+02 Total 20 1.01E+02 9.68E+01 9.79E+01 1.07E+02 1.22E+02 1.00E+02 1.06E+02 9.95E+01 1.00E+02 1.24E+02 1.07E+02 1.02E+02 Dose (krad(Si)) 50 100 1.01E+02 1.01E+02 9.68E+01 9.67E+01 9.79E+01 9.78E+01 1.06E+02 1.06E+02 1.19E+02 1.17E+02 9.99E+01 9.98E+01 1.06E+02 1.06E+02 9.94E+01 9.92E+01 1.00E+02 1.00E+02 1.29E+02 1.46E+02 1.07E+02 1.07E+02 1.02E+02 1.02E+02 200 1.01E+02 9.65E+01 9.77E+01 1.06E+02 1.15E+02 9.96E+01 1.06E+02 9.91E+01 1.00E+02 1.32E+02 1.08E+02 1.02E+02 1.05E+02 1.09E+01 1.35E+02 7.55E+01 1.05E+02 1.02E+01 1.33E+02 7.68E+01 1.04E+02 9.25E+00 1.30E+02 7.89E+01 1.04E+02 8.29E+00 1.26E+02 8.10E+01 1.03E+02 7.58E+00 1.24E+02 8.24E+01 1.06E+02 1.02E+01 1.34E+02 7.81E+01 9.00E+01 PASS 1.06E+02 1.06E+01 1.35E+02 7.71E+01 8.60E+01 PASS 1.07E+02 1.27E+01 1.42E+02 7.22E+01 8.60E+01 PASS 1.10E+02 2.00E+01 1.65E+02 5.51E+01 8.60E+01 PASS 1.07E+02 1.39E+01 1.45E+02 6.91E+01 8.60E+01 PASS An ISO 9001:2008 and DSCC Certified Company 181 Common Mode Rejection Ratio1 4 (dB) @ VS=+/-15V, VCM=+/-15V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.86. Plot of Common Mode Rejection Ratio1 4 (dB) @ VS=+/-15V, VCM=+/-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 182 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.86. Raw data for Common Mode Rejection Ratio1 4 (dB) @ VS=+/-15V, VCM=+/-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Common Mode Rejection Ratio1 4 (dB) @ VS=+/-15V, VCM=+/-15V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 1.01E+02 1.10E+02 1.11E+02 1.06E+02 1.05E+02 1.15E+02 9.66E+01 1.10E+02 1.04E+02 1.07E+02 1.11E+02 1.06E+02 Total 20 1.01E+02 1.09E+02 1.10E+02 1.05E+02 1.04E+02 1.14E+02 9.66E+01 1.09E+02 1.04E+02 1.06E+02 1.11E+02 1.06E+02 Dose (krad(Si)) 50 100 1.01E+02 1.01E+02 1.08E+02 1.08E+02 1.10E+02 1.10E+02 1.05E+02 1.05E+02 1.04E+02 1.04E+02 1.14E+02 1.13E+02 9.66E+01 9.66E+01 1.09E+02 1.09E+02 1.04E+02 1.03E+02 1.06E+02 1.06E+02 1.12E+02 1.12E+02 1.06E+02 1.06E+02 200 1.01E+02 1.08E+02 1.09E+02 1.05E+02 1.04E+02 1.12E+02 9.66E+01 1.08E+02 1.03E+02 1.06E+02 1.11E+02 1.06E+02 1.06E+02 3.90E+00 1.17E+02 9.57E+01 1.06E+02 3.63E+00 1.16E+02 9.60E+01 1.06E+02 3.54E+00 1.16E+02 9.62E+01 1.06E+02 3.27E+00 1.15E+02 9.67E+01 1.05E+02 3.20E+00 1.14E+02 9.65E+01 1.06E+02 6.78E+00 1.25E+02 8.78E+01 9.00E+01 PASS 1.06E+02 6.47E+00 1.24E+02 8.82E+01 8.60E+01 PASS 1.06E+02 6.37E+00 1.23E+02 8.83E+01 8.60E+01 PASS 1.06E+02 6.12E+00 1.22E+02 8.88E+01 8.60E+01 PASS 1.05E+02 5.81E+00 1.21E+02 8.93E+01 8.60E+01 PASS An ISO 9001:2008 and DSCC Certified Company 183 CMRR Match1 1 to 4 (dB) @ VS=+/-15V, VCM=+/-15V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN 1.60E+02 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.87. Plot of CMRR Match1 1 to 4 (dB) @ VS=+/-15V, VCM=+/-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 184 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.87. Raw data for CMRR Match1 1 to 4 (dB) @ VS=+/-15V, VCM=+/-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). CMRR Match1 1 to 4 (dB) @ VS=+/-15V, VCM=+/-15V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 1.13E+02 1.12E+02 1.05E+02 1.04E+02 1.04E+02 1.08E+02 1.16E+02 1.20E+02 1.11E+02 1.18E+02 9.61E+01 1.00E+02 Total 20 1.13E+02 1.14E+02 1.06E+02 1.04E+02 1.05E+02 1.08E+02 1.15E+02 1.27E+02 1.11E+02 1.18E+02 9.61E+01 1.00E+02 Dose (krad(Si)) 50 100 1.13E+02 1.14E+02 1.14E+02 1.14E+02 1.06E+02 1.06E+02 1.04E+02 1.04E+02 1.05E+02 1.05E+02 1.08E+02 1.08E+02 1.16E+02 1.17E+02 1.23E+02 1.23E+02 1.11E+02 1.11E+02 1.18E+02 1.16E+02 9.62E+01 9.61E+01 1.00E+02 1.00E+02 200 1.13E+02 1.13E+02 1.06E+02 1.04E+02 1.05E+02 1.08E+02 1.17E+02 1.22E+02 1.11E+02 1.15E+02 9.61E+01 1.00E+02 1.08E+02 4.56E+00 1.20E+02 9.53E+01 1.08E+02 4.72E+00 1.21E+02 9.54E+01 1.08E+02 4.82E+00 1.22E+02 9.51E+01 1.08E+02 5.03E+00 1.22E+02 9.47E+01 1.08E+02 4.70E+00 1.21E+02 9.53E+01 1.15E+02 5.03E+00 1.29E+02 1.01E+02 8.40E+01 PASS 1.16E+02 7.16E+00 1.36E+02 9.63E+01 8.30E+01 PASS 1.15E+02 5.85E+00 1.31E+02 9.92E+01 8.30E+01 PASS 1.15E+02 5.91E+00 1.31E+02 9.89E+01 8.30E+01 PASS 1.15E+02 5.42E+00 1.30E+02 9.98E+01 8.30E+01 PASS An ISO 9001:2008 and DSCC Certified Company 185 CMRR Match1 2 to 3 (dB) @ VS=+/-15V, VCM=+/-15V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN 1.60E+02 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.88. Plot of CMRR Match1 2 to 3 (dB) @ VS=+/-15V, VCM=+/-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 186 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.88. Raw data for CMRR Match1 2 to 3 (dB) @ VS=+/-15V, VCM=+/-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). CMRR Match1 2 to 3 (dB) @ VS=+/-15V, VCM=+/-15V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 1.17E+02 9.82E+01 1.20E+02 1.02E+02 1.14E+02 1.00E+02 1.03E+02 1.16E+02 1.11E+02 9.93E+01 9.90E+01 1.12E+02 Total 20 1.27E+02 9.85E+01 1.17E+02 1.02E+02 1.11E+02 1.01E+02 1.03E+02 1.16E+02 1.12E+02 9.92E+01 9.90E+01 1.12E+02 Dose (krad(Si)) 50 100 1.25E+02 1.22E+02 9.85E+01 9.85E+01 1.17E+02 1.17E+02 1.02E+02 1.02E+02 1.11E+02 1.11E+02 1.01E+02 1.01E+02 1.03E+02 1.03E+02 1.17E+02 1.17E+02 1.12E+02 1.11E+02 9.93E+01 9.95E+01 9.90E+01 9.90E+01 1.12E+02 1.12E+02 200 1.20E+02 9.85E+01 1.17E+02 1.02E+02 1.11E+02 1.01E+02 1.03E+02 1.17E+02 1.11E+02 9.97E+01 9.90E+01 1.12E+02 1.10E+02 9.54E+00 1.36E+02 8.42E+01 1.11E+02 1.15E+01 1.43E+02 7.96E+01 1.11E+02 1.08E+01 1.40E+02 8.11E+01 1.10E+02 9.78E+00 1.37E+02 8.33E+01 1.10E+02 9.32E+00 1.35E+02 8.43E+01 1.06E+02 7.39E+00 1.26E+02 8.57E+01 8.40E+01 PASS 1.06E+02 7.60E+00 1.27E+02 8.53E+01 8.30E+01 PASS 1.06E+02 7.58E+00 1.27E+02 8.54E+01 8.30E+01 PASS 1.06E+02 7.71E+00 1.27E+02 8.51E+01 8.30E+01 PASS 1.06E+02 7.60E+00 1.27E+02 8.55E+01 8.30E+01 PASS An ISO 9001:2008 and DSCC Certified Company 187 Power Supply Rejection Ratio1 1 (dB) @ VS=+/-2V to +/16V TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.89. Plot of Power Supply Rejection Ratio1 1 (dB) @ VS=+/-2V to +/-16V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 188 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.89. Raw data for Power Supply Rejection Ratio1 1 (dB) @ VS=+/-2V to +/-16V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Power Supply Rejection Ratio1 1 (dB) @ VS=+/-2V to +/-16V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 1.17E+02 1.04E+02 1.16E+02 1.06E+02 1.10E+02 1.13E+02 1.30E+02 1.05E+02 1.08E+02 1.09E+02 1.09E+02 1.26E+02 Total 20 1.17E+02 1.04E+02 1.16E+02 1.06E+02 1.10E+02 1.13E+02 1.29E+02 1.05E+02 1.08E+02 1.09E+02 1.09E+02 1.25E+02 Dose (krad(Si)) 50 100 1.17E+02 1.16E+02 1.04E+02 1.04E+02 1.16E+02 1.16E+02 1.06E+02 1.06E+02 1.10E+02 1.10E+02 1.12E+02 1.12E+02 1.28E+02 1.28E+02 1.06E+02 1.06E+02 1.08E+02 1.08E+02 1.09E+02 1.10E+02 1.09E+02 1.09E+02 1.25E+02 1.25E+02 200 1.16E+02 1.04E+02 1.17E+02 1.06E+02 1.10E+02 1.12E+02 1.26E+02 1.06E+02 1.08E+02 1.10E+02 1.09E+02 1.25E+02 1.10E+02 5.82E+00 1.26E+02 9.44E+01 1.10E+02 5.83E+00 1.26E+02 9.45E+01 1.11E+02 5.86E+00 1.27E+02 9.45E+01 1.10E+02 5.66E+00 1.26E+02 9.49E+01 1.11E+02 5.65E+00 1.26E+02 9.51E+01 1.13E+02 9.76E+00 1.40E+02 8.64E+01 9.00E+01 PASS 1.13E+02 9.28E+00 1.38E+02 8.75E+01 9.00E+01 PASS 1.13E+02 8.98E+00 1.37E+02 8.82E+01 9.00E+01 PASS 1.13E+02 8.79E+00 1.37E+02 8.87E+01 9.00E+01 PASS 1.13E+02 8.14E+00 1.35E+02 9.02E+01 9.00E+01 PASS An ISO 9001:2008 and DSCC Certified Company 189 Power Supply Rejection Ratio1 2 (dB) @ VS=+/-2V to +/16V TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.90. Plot of Power Supply Rejection Ratio1 2 (dB) @ VS=+/-2V to +/-16V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 190 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.90. Raw data for Power Supply Rejection Ratio1 2 (dB) @ VS=+/-2V to +/-16V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Power Supply Rejection Ratio1 2 (dB) @ VS=+/-2V to +/-16V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 1.12E+02 1.06E+02 1.03E+02 1.10E+02 1.02E+02 1.07E+02 1.12E+02 1.11E+02 1.13E+02 1.03E+02 1.01E+02 1.24E+02 Total 20 1.12E+02 1.06E+02 1.03E+02 1.10E+02 1.02E+02 1.07E+02 1.12E+02 1.11E+02 1.13E+02 1.03E+02 1.01E+02 1.25E+02 Dose (krad(Si)) 50 100 1.12E+02 1.12E+02 1.06E+02 1.06E+02 1.03E+02 1.03E+02 1.10E+02 1.10E+02 1.02E+02 1.02E+02 1.07E+02 1.07E+02 1.12E+02 1.12E+02 1.11E+02 1.11E+02 1.13E+02 1.13E+02 1.03E+02 1.03E+02 1.01E+02 1.01E+02 1.25E+02 1.25E+02 200 1.12E+02 1.06E+02 1.04E+02 1.10E+02 1.02E+02 1.07E+02 1.12E+02 1.11E+02 1.13E+02 1.03E+02 1.01E+02 1.25E+02 1.07E+02 4.20E+00 1.18E+02 9.52E+01 1.07E+02 4.15E+00 1.18E+02 9.54E+01 1.07E+02 4.19E+00 1.18E+02 9.53E+01 1.07E+02 4.19E+00 1.18E+02 9.53E+01 1.07E+02 4.25E+00 1.18E+02 9.52E+01 1.09E+02 4.00E+00 1.20E+02 9.83E+01 9.00E+01 PASS 1.09E+02 4.00E+00 1.20E+02 9.84E+01 9.00E+01 PASS 1.09E+02 4.01E+00 1.20E+02 9.84E+01 9.00E+01 PASS 1.09E+02 4.00E+00 1.20E+02 9.84E+01 9.00E+01 PASS 1.09E+02 3.96E+00 1.20E+02 9.84E+01 9.00E+01 PASS An ISO 9001:2008 and DSCC Certified Company 191 Power Supply Rejection Ratio1 3 (dB) @ VS=+/-2V to +/16V TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.91. Plot of Power Supply Rejection Ratio1 3 (dB) @ VS=+/-2V to +/-16V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 192 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.91. Raw data for Power Supply Rejection Ratio1 3 (dB) @ VS=+/-2V to +/-16V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Power Supply Rejection Ratio1 3 (dB) @ VS=+/-2V to +/-16V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 1.18E+02 1.03E+02 1.12E+02 1.20E+02 1.09E+02 1.37E+02 1.07E+02 1.11E+02 1.27E+02 1.05E+02 1.02E+02 1.06E+02 Total 20 1.18E+02 1.03E+02 1.12E+02 1.20E+02 1.09E+02 1.37E+02 1.07E+02 1.11E+02 1.27E+02 1.05E+02 1.02E+02 1.06E+02 Dose (krad(Si)) 50 100 1.17E+02 1.17E+02 1.03E+02 1.03E+02 1.12E+02 1.12E+02 1.21E+02 1.20E+02 1.09E+02 1.09E+02 1.37E+02 1.38E+02 1.07E+02 1.07E+02 1.11E+02 1.11E+02 1.27E+02 1.27E+02 1.05E+02 1.06E+02 1.02E+02 1.02E+02 1.06E+02 1.06E+02 200 1.17E+02 1.03E+02 1.13E+02 1.21E+02 1.10E+02 1.38E+02 1.07E+02 1.12E+02 1.28E+02 1.06E+02 1.02E+02 1.06E+02 1.12E+02 7.01E+00 1.31E+02 9.30E+01 1.12E+02 7.06E+00 1.32E+02 9.30E+01 1.12E+02 7.05E+00 1.32E+02 9.31E+01 1.12E+02 6.88E+00 1.31E+02 9.35E+01 1.13E+02 6.89E+00 1.31E+02 9.36E+01 1.18E+02 1.39E+01 1.56E+02 7.94E+01 9.00E+01 PASS 1.18E+02 1.38E+01 1.55E+02 7.98E+01 9.00E+01 PASS 1.18E+02 1.40E+01 1.56E+02 7.94E+01 9.00E+01 PASS 1.18E+02 1.42E+01 1.57E+02 7.90E+01 9.00E+01 PASS 1.18E+02 1.42E+01 1.57E+02 7.90E+01 9.00E+01 PASS An ISO 9001:2008 and DSCC Certified Company 193 Power Supply Rejection Ratio1 4 (dB) @ VS=+/-2V to +/16V TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.92. Plot of Power Supply Rejection Ratio1 4 (dB) @ VS=+/-2V to +/-16V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 194 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.92. Raw data for Power Supply Rejection Ratio1 4 (dB) @ VS=+/-2V to +/-16V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Power Supply Rejection Ratio1 4 (dB) @ VS=+/-2V to +/-16V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 1.04E+02 1.01E+02 1.01E+02 1.03E+02 1.06E+02 1.09E+02 1.23E+02 1.06E+02 1.02E+02 1.13E+02 1.02E+02 1.18E+02 Total 20 1.04E+02 1.02E+02 1.01E+02 1.03E+02 1.06E+02 1.09E+02 1.23E+02 1.06E+02 1.02E+02 1.13E+02 1.02E+02 1.18E+02 Dose (krad(Si)) 50 100 1.04E+02 1.04E+02 1.02E+02 1.02E+02 1.01E+02 1.01E+02 1.03E+02 1.03E+02 1.06E+02 1.06E+02 1.09E+02 1.09E+02 1.24E+02 1.24E+02 1.06E+02 1.06E+02 1.02E+02 1.02E+02 1.13E+02 1.13E+02 1.02E+02 1.02E+02 1.18E+02 1.18E+02 200 1.04E+02 1.02E+02 1.01E+02 1.03E+02 1.06E+02 1.09E+02 1.25E+02 1.06E+02 1.02E+02 1.13E+02 1.02E+02 1.18E+02 1.03E+02 1.81E+00 1.08E+02 9.80E+01 1.03E+02 1.83E+00 1.08E+02 9.81E+01 1.03E+02 1.82E+00 1.08E+02 9.81E+01 1.03E+02 1.81E+00 1.08E+02 9.81E+01 1.03E+02 1.74E+00 1.08E+02 9.83E+01 1.11E+02 7.99E+00 1.33E+02 8.89E+01 9.00E+01 PASS 1.11E+02 8.09E+00 1.33E+02 8.87E+01 9.00E+01 PASS 1.11E+02 8.30E+00 1.34E+02 8.82E+01 9.00E+01 PASS 1.11E+02 8.26E+00 1.34E+02 8.83E+01 9.00E+01 PASS 1.11E+02 8.68E+00 1.35E+02 8.73E+01 9.00E+01 PASS An ISO 9001:2008 and DSCC Certified Company 195 TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased PSRR Match1 1 to 4 (dB) @ VS=+/-2V to +/-16V 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.93. Plot of PSRR Match1 1 to 4 (dB) @ VS=+/-2V to +/-16V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 196 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.93. Raw data for PSRR Match1 1 to 4 (dB) @ VS=+/-2V to +/-16V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). PSRR Match1 1 to 4 (dB) @ VS=+/-2V to +/-16V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 1.06E+02 1.15E+02 1.03E+02 1.14E+02 1.14E+02 1.05E+02 1.29E+02 1.27E+02 1.09E+02 1.18E+02 1.07E+02 1.15E+02 Total 20 1.06E+02 1.15E+02 1.03E+02 1.14E+02 1.14E+02 1.05E+02 1.30E+02 1.27E+02 1.08E+02 1.18E+02 1.07E+02 1.15E+02 Dose (krad(Si)) 50 100 1.06E+02 1.06E+02 1.15E+02 1.15E+02 1.03E+02 1.03E+02 1.14E+02 1.14E+02 1.14E+02 1.14E+02 1.05E+02 1.05E+02 1.32E+02 1.32E+02 1.28E+02 1.27E+02 1.08E+02 1.08E+02 1.18E+02 1.19E+02 1.07E+02 1.07E+02 1.15E+02 1.15E+02 200 1.06E+02 1.14E+02 1.03E+02 1.13E+02 1.14E+02 1.04E+02 1.41E+02 1.29E+02 1.08E+02 1.20E+02 1.07E+02 1.15E+02 1.10E+02 5.57E+00 1.26E+02 9.51E+01 1.10E+02 5.53E+00 1.26E+02 9.52E+01 1.10E+02 5.48E+00 1.25E+02 9.53E+01 1.10E+02 5.41E+00 1.25E+02 9.54E+01 1.10E+02 5.10E+00 1.24E+02 9.61E+01 1.17E+02 1.06E+01 1.46E+02 8.82E+01 8.30E+01 PASS 1.18E+02 1.11E+01 1.48E+02 8.71E+01 8.30E+01 PASS 1.18E+02 1.20E+01 1.51E+02 8.55E+01 8.30E+01 PASS 1.18E+02 1.20E+01 1.51E+02 8.54E+01 8.30E+01 PASS 1.20E+02 1.49E+01 1.61E+02 7.94E+01 8.30E+01 PASS An ISO 9001:2008 and DSCC Certified Company 197 TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased PSRR Match1 2 to 3 (dB) @ VS=+/-2V to +/-16V 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.94. Plot of PSRR Match1 2 to 3 (dB) @ VS=+/-2V to +/-16V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 198 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.94. Raw data for PSRR Match1 2 to 3 (dB) @ VS=+/-2V to +/-16V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). PSRR Match1 2 to 3 (dB) @ VS=+/-2V to +/-16V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 1.18E+02 1.12E+02 1.08E+02 1.08E+02 1.08E+02 1.07E+02 1.14E+02 1.05E+02 1.12E+02 1.18E+02 1.19E+02 1.07E+02 Total 20 1.19E+02 1.12E+02 1.07E+02 1.08E+02 1.08E+02 1.07E+02 1.14E+02 1.05E+02 1.12E+02 1.18E+02 1.19E+02 1.07E+02 Dose (krad(Si)) 50 100 1.19E+02 1.20E+02 1.12E+02 1.12E+02 1.07E+02 1.07E+02 1.07E+02 1.07E+02 1.07E+02 1.07E+02 1.08E+02 1.08E+02 1.14E+02 1.14E+02 1.05E+02 1.05E+02 1.12E+02 1.12E+02 1.17E+02 1.17E+02 1.19E+02 1.19E+02 1.07E+02 1.07E+02 200 1.20E+02 1.12E+02 1.07E+02 1.08E+02 1.07E+02 1.08E+02 1.15E+02 1.05E+02 1.12E+02 1.17E+02 1.19E+02 1.07E+02 1.11E+02 4.77E+00 1.24E+02 9.76E+01 1.11E+02 4.86E+00 1.24E+02 9.73E+01 1.11E+02 5.21E+00 1.25E+02 9.64E+01 1.11E+02 5.40E+00 1.26E+02 9.59E+01 1.11E+02 5.70E+00 1.26E+02 9.52E+01 1.11E+02 5.04E+00 1.25E+02 9.73E+01 8.30E+01 PASS 1.11E+02 5.02E+00 1.25E+02 9.74E+01 8.30E+01 PASS 1.11E+02 4.91E+00 1.25E+02 9.77E+01 8.30E+01 PASS 1.11E+02 4.82E+00 1.24E+02 9.79E+01 8.30E+01 PASS 1.11E+02 4.89E+00 1.25E+02 9.78E+01 8.30E+01 PASS An ISO 9001:2008 and DSCC Certified Company 199 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased +Short-Circuit Current1 1 (A) @ VS=+/-15V, VOUT=0V Specification MAX 0.00E+00 -5.00E-03 -1.00E-02 -1.50E-02 -2.00E-02 -2.50E-02 -3.00E-02 -3.50E-02 -4.00E-02 -4.50E-02 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.95. Plot of +Short-Circuit Current1 1 (A) @ VS=+/-15V, VOUT=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 200 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.95. Raw data for +Short-Circuit Current1 1 (A) @ VS=+/-15V, VOUT=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Short-Circuit Current1 1 (A) @ VS=+/-15V, VOUT=0V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MAX Status 0 -3.85E-02 -4.10E-02 -4.16E-02 -3.80E-02 -4.42E-02 -4.02E-02 -3.77E-02 -4.02E-02 -4.03E-02 -4.04E-02 -3.97E-02 -4.48E-02 Total 20 -3.72E-02 -3.96E-02 -4.02E-02 -3.64E-02 -4.32E-02 -3.92E-02 -3.68E-02 -3.93E-02 -3.95E-02 -3.95E-02 -3.92E-02 -4.45E-02 Dose (krad(Si)) 50 100 -3.65E-02 -3.56E-02 -3.85E-02 -3.77E-02 -3.92E-02 -3.83E-02 -3.55E-02 -3.46E-02 -4.17E-02 -4.08E-02 -3.84E-02 -3.76E-02 -3.61E-02 -3.54E-02 -3.85E-02 -3.77E-02 -3.87E-02 -3.79E-02 -3.87E-02 -3.79E-02 -3.92E-02 -3.92E-02 -4.44E-02 -4.45E-02 200 -3.45E-02 -3.71E-02 -3.75E-02 -3.38E-02 -4.05E-02 -3.64E-02 -3.44E-02 -3.66E-02 -3.68E-02 -3.68E-02 -3.93E-02 -4.46E-02 -4.07E-02 -3.93E-02 -3.83E-02 -3.74E-02 -3.67E-02 2.53E-03 2.68E-03 2.43E-03 2.45E-03 2.65E-03 -3.37E-02 -3.20E-02 -3.16E-02 -3.07E-02 -2.94E-02 -4.76E-02 -4.66E-02 -4.49E-02 -4.41E-02 -4.40E-02 -3.97E-02 1.16E-03 -3.66E-02 -4.29E-02 -1.50E-02 PASS -3.89E-02 1.14E-03 -3.57E-02 -4.20E-02 -1.00E-02 PASS -3.81E-02 1.10E-03 -3.51E-02 -4.11E-02 -1.00E-02 PASS An ISO 9001:2008 and DSCC Certified Company 201 -3.73E-02 1.04E-03 -3.44E-02 -4.01E-02 -1.00E-02 PASS -3.62E-02 9.94E-04 -3.35E-02 -3.89E-02 -1.00E-02 PASS TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased +Short-Circuit Current1 2 (A) @ VS=+/-15V, VOUT=0V Specification MAX 0.00E+00 -5.00E-03 -1.00E-02 -1.50E-02 -2.00E-02 -2.50E-02 -3.00E-02 -3.50E-02 -4.00E-02 -4.50E-02 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.96. Plot of +Short-Circuit Current1 2 (A) @ VS=+/-15V, VOUT=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 202 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.96. Raw data for +Short-Circuit Current1 2 (A) @ VS=+/-15V, VOUT=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Short-Circuit Current1 2 (A) @ VS=+/-15V, VOUT=0V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MAX Status 0 -4.01E-02 -4.07E-02 -4.19E-02 -4.01E-02 -4.30E-02 -4.14E-02 -4.09E-02 -4.13E-02 -4.03E-02 -4.07E-02 -3.85E-02 -4.09E-02 Total 20 -3.88E-02 -3.93E-02 -4.06E-02 -3.85E-02 -4.19E-02 -4.05E-02 -4.00E-02 -4.04E-02 -3.96E-02 -3.98E-02 -3.80E-02 -4.07E-02 Dose (krad(Si)) 50 100 -3.81E-02 -3.72E-02 -3.83E-02 -3.75E-02 -3.97E-02 -3.89E-02 -3.76E-02 -3.67E-02 -4.03E-02 -3.94E-02 -3.97E-02 -3.89E-02 -3.92E-02 -3.84E-02 -3.96E-02 -3.88E-02 -3.88E-02 -3.80E-02 -3.90E-02 -3.81E-02 -3.79E-02 -3.79E-02 -4.06E-02 -4.07E-02 200 -3.60E-02 -3.69E-02 -3.79E-02 -3.59E-02 -3.88E-02 -3.76E-02 -3.73E-02 -3.77E-02 -3.70E-02 -3.70E-02 -3.80E-02 -4.08E-02 -4.12E-02 -3.98E-02 -3.88E-02 -3.79E-02 -3.71E-02 1.29E-03 1.42E-03 1.16E-03 1.15E-03 1.27E-03 -3.76E-02 -3.60E-02 -3.56E-02 -3.48E-02 -3.36E-02 -4.47E-02 -4.37E-02 -4.20E-02 -4.11E-02 -4.06E-02 -4.09E-02 4.39E-04 -3.97E-02 -4.21E-02 -1.50E-02 PASS -4.00E-02 3.94E-04 -3.89E-02 -4.11E-02 -1.00E-02 PASS -3.92E-02 3.88E-04 -3.82E-02 -4.03E-02 -1.00E-02 PASS An ISO 9001:2008 and DSCC Certified Company 203 -3.84E-02 4.05E-04 -3.73E-02 -3.95E-02 -1.00E-02 PASS -3.73E-02 3.48E-04 -3.64E-02 -3.83E-02 -1.00E-02 PASS TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased +Short-Circuit Current1 3 (A) @ VS=+/-15V, VOUT=0V Specification MAX 0.00E+00 -5.00E-03 -1.00E-02 -1.50E-02 -2.00E-02 -2.50E-02 -3.00E-02 -3.50E-02 -4.00E-02 -4.50E-02 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.97. Plot of +Short-Circuit Current1 3 (A) @ VS=+/-15V, VOUT=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 204 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.97. Raw data for +Short-Circuit Current1 3 (A) @ VS=+/-15V, VOUT=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Short-Circuit Current1 3 (A) @ VS=+/-15V, VOUT=0V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MAX Status 0 -4.02E-02 -3.96E-02 -4.28E-02 -4.07E-02 -4.36E-02 -4.22E-02 -4.05E-02 -4.17E-02 -4.10E-02 -4.15E-02 -3.83E-02 -4.05E-02 Total 20 -3.90E-02 -3.82E-02 -4.15E-02 -3.91E-02 -4.25E-02 -4.12E-02 -3.95E-02 -4.08E-02 -4.02E-02 -4.05E-02 -3.78E-02 -4.02E-02 Dose (krad(Si)) 50 100 -3.82E-02 -3.73E-02 -3.71E-02 -3.63E-02 -4.05E-02 -3.97E-02 -3.81E-02 -3.72E-02 -4.09E-02 -4.00E-02 -4.04E-02 -3.96E-02 -3.88E-02 -3.80E-02 -4.00E-02 -3.92E-02 -3.94E-02 -3.86E-02 -3.97E-02 -3.88E-02 -3.78E-02 -3.77E-02 -4.02E-02 -4.02E-02 200 -3.61E-02 -3.57E-02 -3.87E-02 -3.63E-02 -3.93E-02 -3.83E-02 -3.68E-02 -3.81E-02 -3.76E-02 -3.77E-02 -3.78E-02 -4.03E-02 -4.14E-02 -4.00E-02 -3.90E-02 -3.81E-02 -3.72E-02 1.74E-03 1.86E-03 1.65E-03 1.63E-03 1.66E-03 -3.66E-02 -3.50E-02 -3.45E-02 -3.36E-02 -3.27E-02 -4.61E-02 -4.51E-02 -4.35E-02 -4.26E-02 -4.18E-02 -4.14E-02 6.66E-04 -3.95E-02 -4.32E-02 -1.50E-02 PASS -4.05E-02 6.40E-04 -3.87E-02 -4.22E-02 -1.00E-02 PASS -3.97E-02 6.29E-04 -3.79E-02 -4.14E-02 -1.00E-02 PASS An ISO 9001:2008 and DSCC Certified Company 205 -3.88E-02 6.15E-04 -3.71E-02 -4.05E-02 -1.00E-02 PASS -3.77E-02 5.76E-04 -3.61E-02 -3.93E-02 -1.00E-02 PASS TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased +Short-Circuit Current1 4 (A) @ VS=+/-15V, VOUT=0V Specification MAX 0.00E+00 -5.00E-03 -1.00E-02 -1.50E-02 -2.00E-02 -2.50E-02 -3.00E-02 -3.50E-02 -4.00E-02 -4.50E-02 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.98. Plot of +Short-Circuit Current1 4 (A) @ VS=+/-15V, VOUT=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 206 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.98. Raw data for +Short-Circuit Current1 4 (A) @ VS=+/-15V, VOUT=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Short-Circuit Current1 4 (A) @ VS=+/-15V, VOUT=0V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MAX Status 0 -3.85E-02 -4.14E-02 -4.25E-02 -3.87E-02 -4.60E-02 -4.04E-02 -3.94E-02 -4.04E-02 -4.09E-02 -4.16E-02 -4.13E-02 -4.59E-02 Total 20 -3.72E-02 -4.00E-02 -4.11E-02 -3.71E-02 -4.49E-02 -3.95E-02 -3.85E-02 -3.95E-02 -4.01E-02 -4.07E-02 -4.08E-02 -4.56E-02 Dose (krad(Si)) 50 100 -3.65E-02 -3.56E-02 -3.90E-02 -3.82E-02 -4.01E-02 -3.92E-02 -3.62E-02 -3.54E-02 -4.34E-02 -4.26E-02 -3.87E-02 -3.79E-02 -3.78E-02 -3.70E-02 -3.87E-02 -3.78E-02 -3.93E-02 -3.85E-02 -3.99E-02 -3.90E-02 -4.08E-02 -4.08E-02 -4.56E-02 -4.56E-02 200 -3.45E-02 -3.75E-02 -3.83E-02 -3.45E-02 -4.21E-02 -3.66E-02 -3.60E-02 -3.67E-02 -3.74E-02 -3.79E-02 -4.08E-02 -4.57E-02 -4.14E-02 -4.01E-02 -3.90E-02 -3.82E-02 -3.74E-02 3.06E-03 3.20E-03 2.95E-03 2.95E-03 3.13E-03 -3.30E-02 -3.13E-02 -3.09E-02 -3.01E-02 -2.88E-02 -4.98E-02 -4.89E-02 -4.71E-02 -4.63E-02 -4.60E-02 -4.05E-02 8.11E-04 -3.83E-02 -4.28E-02 -1.50E-02 PASS -3.96E-02 8.08E-04 -3.74E-02 -4.19E-02 -1.00E-02 PASS -3.89E-02 7.83E-04 -3.67E-02 -4.10E-02 -1.00E-02 PASS An ISO 9001:2008 and DSCC Certified Company 207 -3.80E-02 7.26E-04 -3.60E-02 -4.00E-02 -1.00E-02 PASS -3.69E-02 7.29E-04 -3.49E-02 -3.89E-02 -1.00E-02 PASS -Short-Circuit Current1 1 (A) @ VS=+/-15V, VOUT=0V TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 7.00E-02 6.00E-02 5.00E-02 4.00E-02 3.00E-02 2.00E-02 1.00E-02 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.99. Plot of -Short-Circuit Current1 1 (A) @ VS=+/-15V, VOUT=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 208 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.99. Raw data for -Short-Circuit Current1 1 (A) @ VS=+/-15V, VOUT=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) -Short-Circuit Current1 1 (A) @ VS=+/-15V, VOUT=0V Device 0 20 50 100 200 519 5.92E-02 5.91E-02 5.88E-02 5.88E-02 5.89E-02 520 5.94E-02 5.94E-02 5.94E-02 5.93E-02 5.90E-02 521 6.03E-02 6.03E-02 6.04E-02 6.01E-02 6.00E-02 522 5.99E-02 6.03E-02 6.02E-02 6.01E-02 5.98E-02 524 5.94E-02 6.00E-02 5.98E-02 5.96E-02 5.92E-02 536 5.83E-02 5.88E-02 5.88E-02 5.86E-02 5.84E-02 537 5.98E-02 6.02E-02 6.02E-02 6.00E-02 5.97E-02 538 5.99E-02 6.01E-02 6.01E-02 5.99E-02 5.96E-02 539 5.86E-02 5.88E-02 5.88E-02 5.86E-02 5.82E-02 542 6.04E-02 6.08E-02 6.07E-02 6.06E-02 6.02E-02 543 6.05E-02 6.13E-02 6.13E-02 6.14E-02 6.12E-02 544 6.17E-02 6.21E-02 6.22E-02 6.22E-02 6.21E-02 Biased Statistics Average Biased 5.96E-02 5.98E-02 5.97E-02 5.96E-02 5.94E-02 Std Dev Biased 4.36E-04 5.36E-04 6.49E-04 5.80E-04 4.84E-04 Ps90%/90% (+KTL) Biased 6.08E-02 6.13E-02 6.15E-02 6.12E-02 6.07E-02 Ps90%/90% (-KTL) Biased 5.84E-02 5.83E-02 5.79E-02 5.80E-02 5.81E-02 Un-Biased Statistics Average Un-Biased 5.94E-02 5.97E-02 5.97E-02 5.95E-02 5.92E-02 Std Dev Un-Biased 8.85E-04 9.08E-04 8.75E-04 9.05E-04 8.54E-04 Ps90%/90% (+KTL) Un-Biased 6.18E-02 6.22E-02 6.21E-02 6.20E-02 6.15E-02 Ps90%/90% (-KTL) Un-Biased 5.69E-02 5.73E-02 5.73E-02 5.70E-02 5.69E-02 Specification MIN 1.50E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 209 -Short-Circuit Current1 2 (A) @ VS=+/-15V, VOUT=0V TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 7.00E-02 6.00E-02 5.00E-02 4.00E-02 3.00E-02 2.00E-02 1.00E-02 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.100. Plot of -Short-Circuit Current1 2 (A) @ VS=+/-15V, VOUT=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 210 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.100. Raw data for -Short-Circuit Current1 2 (A) @ VS=+/-15V, VOUT=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) -Short-Circuit Current1 2 (A) @ VS=+/-15V, VOUT=0V Device 0 20 50 100 200 519 5.89E-02 5.87E-02 5.83E-02 5.84E-02 5.85E-02 520 5.77E-02 5.76E-02 5.77E-02 5.75E-02 5.72E-02 521 5.98E-02 5.98E-02 5.98E-02 5.96E-02 5.95E-02 522 5.92E-02 5.95E-02 5.94E-02 5.93E-02 5.89E-02 524 5.77E-02 5.82E-02 5.80E-02 5.78E-02 5.73E-02 536 5.74E-02 5.78E-02 5.79E-02 5.77E-02 5.75E-02 537 5.88E-02 5.93E-02 5.92E-02 5.89E-02 5.87E-02 538 5.91E-02 5.94E-02 5.94E-02 5.92E-02 5.88E-02 539 5.91E-02 5.93E-02 5.93E-02 5.91E-02 5.87E-02 542 5.91E-02 5.95E-02 5.95E-02 5.93E-02 5.89E-02 543 5.73E-02 5.80E-02 5.82E-02 5.82E-02 5.80E-02 544 5.94E-02 5.98E-02 5.99E-02 5.99E-02 5.97E-02 Biased Statistics Average Biased 5.86E-02 5.88E-02 5.86E-02 5.85E-02 5.83E-02 Std Dev Biased 9.31E-04 9.02E-04 9.29E-04 9.14E-04 9.90E-04 Ps90%/90% (+KTL) Biased 6.12E-02 6.12E-02 6.12E-02 6.10E-02 6.10E-02 Ps90%/90% (-KTL) Biased 5.61E-02 5.63E-02 5.61E-02 5.60E-02 5.56E-02 Un-Biased Statistics Average Un-Biased 5.87E-02 5.91E-02 5.90E-02 5.88E-02 5.85E-02 Std Dev Un-Biased 7.35E-04 7.00E-04 6.54E-04 6.74E-04 5.99E-04 Ps90%/90% (+KTL) Un-Biased 6.07E-02 6.10E-02 6.08E-02 6.07E-02 6.02E-02 Ps90%/90% (-KTL) Un-Biased 5.67E-02 5.71E-02 5.72E-02 5.70E-02 5.69E-02 Specification MIN 1.50E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 211 -Short-Circuit Current1 3 (A) @ VS=+/-15V, VOUT=0V TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 7.00E-02 6.00E-02 5.00E-02 4.00E-02 3.00E-02 2.00E-02 1.00E-02 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.101. Plot of -Short-Circuit Current1 3 (A) @ VS=+/-15V, VOUT=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 212 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.101. Raw data for -Short-Circuit Current1 3 (A) @ VS=+/-15V, VOUT=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) -Short-Circuit Current1 3 (A) @ VS=+/-15V, VOUT=0V Device 0 20 50 100 200 519 5.84E-02 5.82E-02 5.79E-02 5.79E-02 5.80E-02 520 5.73E-02 5.73E-02 5.73E-02 5.71E-02 5.69E-02 521 5.98E-02 5.98E-02 5.98E-02 5.96E-02 5.95E-02 522 5.92E-02 5.95E-02 5.95E-02 5.94E-02 5.89E-02 524 5.77E-02 5.83E-02 5.81E-02 5.79E-02 5.74E-02 536 5.75E-02 5.79E-02 5.79E-02 5.77E-02 5.75E-02 537 5.90E-02 5.94E-02 5.93E-02 5.91E-02 5.88E-02 538 5.90E-02 5.93E-02 5.93E-02 5.90E-02 5.88E-02 539 5.90E-02 5.92E-02 5.92E-02 5.90E-02 5.87E-02 542 5.91E-02 5.95E-02 5.94E-02 5.92E-02 5.88E-02 543 5.73E-02 5.79E-02 5.80E-02 5.80E-02 5.79E-02 544 5.92E-02 5.96E-02 5.97E-02 5.97E-02 5.96E-02 Biased Statistics Average Biased 5.85E-02 5.86E-02 5.85E-02 5.84E-02 5.81E-02 Std Dev Biased 1.02E-03 1.04E-03 1.08E-03 1.06E-03 1.05E-03 Ps90%/90% (+KTL) Biased 6.13E-02 6.15E-02 6.15E-02 6.13E-02 6.10E-02 Ps90%/90% (-KTL) Biased 5.57E-02 5.58E-02 5.55E-02 5.55E-02 5.53E-02 Un-Biased Statistics Average Un-Biased 5.87E-02 5.90E-02 5.90E-02 5.88E-02 5.85E-02 Std Dev Un-Biased 7.05E-04 6.64E-04 6.23E-04 6.31E-04 5.67E-04 Ps90%/90% (+KTL) Un-Biased 6.06E-02 6.09E-02 6.07E-02 6.05E-02 6.01E-02 Ps90%/90% (-KTL) Un-Biased 5.68E-02 5.72E-02 5.73E-02 5.71E-02 5.70E-02 Specification MIN 1.50E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 213 -Short-Circuit Current1 4 (A) @ VS=+/-15V, VOUT=0V TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 7.00E-02 6.00E-02 5.00E-02 4.00E-02 3.00E-02 2.00E-02 1.00E-02 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.102. Plot of -Short-Circuit Current1 4 (A) @ VS=+/-15V, VOUT=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 214 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.102. Raw data for -Short-Circuit Current1 4 (A) @ VS=+/-15V, VOUT=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) -Short-Circuit Current1 4 (A) @ VS=+/-15V, VOUT=0V Device 0 20 50 100 200 519 5.71E-02 5.69E-02 5.66E-02 5.66E-02 5.68E-02 520 5.71E-02 5.71E-02 5.71E-02 5.69E-02 5.66E-02 521 5.79E-02 5.79E-02 5.79E-02 5.77E-02 5.76E-02 522 5.75E-02 5.78E-02 5.77E-02 5.76E-02 5.72E-02 524 5.73E-02 5.78E-02 5.76E-02 5.74E-02 5.70E-02 536 5.60E-02 5.64E-02 5.64E-02 5.62E-02 5.60E-02 537 5.71E-02 5.75E-02 5.75E-02 5.72E-02 5.70E-02 538 5.75E-02 5.77E-02 5.76E-02 5.74E-02 5.71E-02 539 5.65E-02 5.67E-02 5.67E-02 5.65E-02 5.61E-02 542 5.80E-02 5.84E-02 5.83E-02 5.82E-02 5.78E-02 543 5.78E-02 5.85E-02 5.86E-02 5.86E-02 5.85E-02 544 5.93E-02 5.97E-02 5.97E-02 5.97E-02 5.96E-02 Biased Statistics Average Biased 5.74E-02 5.75E-02 5.74E-02 5.72E-02 5.70E-02 Std Dev Biased 3.36E-04 4.58E-04 5.37E-04 4.65E-04 3.83E-04 Ps90%/90% (+KTL) Biased 5.83E-02 5.87E-02 5.88E-02 5.85E-02 5.81E-02 Ps90%/90% (-KTL) Biased 5.64E-02 5.62E-02 5.59E-02 5.60E-02 5.60E-02 Un-Biased Statistics Average Un-Biased 5.70E-02 5.73E-02 5.73E-02 5.71E-02 5.68E-02 Std Dev Un-Biased 7.88E-04 8.13E-04 7.53E-04 7.89E-04 7.39E-04 Ps90%/90% (+KTL) Un-Biased 5.92E-02 5.96E-02 5.94E-02 5.93E-02 5.88E-02 Ps90%/90% (-KTL) Un-Biased 5.48E-02 5.51E-02 5.52E-02 5.50E-02 5.48E-02 Specification MIN 1.50E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 215 TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 1.00E-02 +Supply Current (A) @ VS=+5V 9.00E-03 8.00E-03 7.00E-03 6.00E-03 5.00E-03 4.00E-03 3.00E-03 2.00E-03 1.00E-03 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.103. Plot of +Supply Current (A) @ VS=+5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 216 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.103. Raw data for +Supply Current (A) @ VS=+5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) +Supply Current (A) @ VS=+5V Device 0 20 50 100 200 519 7.50E-03 7.38E-03 7.40E-03 7.31E-03 7.29E-03 520 7.52E-03 7.41E-03 7.36E-03 7.34E-03 7.37E-03 521 7.61E-03 7.52E-03 7.46E-03 7.43E-03 7.40E-03 522 7.44E-03 7.33E-03 7.28E-03 7.25E-03 7.23E-03 524 7.53E-03 7.47E-03 7.38E-03 7.35E-03 7.37E-03 536 7.48E-03 7.44E-03 7.40E-03 7.37E-03 7.31E-03 537 7.51E-03 7.46E-03 7.43E-03 7.40E-03 7.35E-03 538 7.33E-03 7.28E-03 7.25E-03 7.22E-03 7.17E-03 539 7.47E-03 7.42E-03 7.39E-03 7.36E-03 7.31E-03 542 7.45E-03 7.40E-03 7.37E-03 7.34E-03 7.28E-03 543 7.44E-03 7.40E-03 7.40E-03 7.40E-03 7.41E-03 544 7.49E-03 7.48E-03 7.47E-03 7.48E-03 7.49E-03 Biased Statistics Average Biased 7.52E-03 7.42E-03 7.37E-03 7.34E-03 7.33E-03 Std Dev Biased 6.05E-05 7.57E-05 6.46E-05 6.75E-05 7.18E-05 Ps90%/90% (+KTL) Biased 7.68E-03 7.63E-03 7.55E-03 7.52E-03 7.53E-03 Ps90%/90% (-KTL) Biased 7.35E-03 7.22E-03 7.20E-03 7.15E-03 7.14E-03 Un-Biased Statistics Average Un-Biased 7.45E-03 7.40E-03 7.37E-03 7.34E-03 7.29E-03 Std Dev Un-Biased 6.86E-05 6.97E-05 6.65E-05 6.87E-05 6.83E-05 Ps90%/90% (+KTL) Un-Biased 7.64E-03 7.59E-03 7.55E-03 7.53E-03 7.47E-03 Ps90%/90% (-KTL) Un-Biased 7.26E-03 7.21E-03 7.18E-03 7.15E-03 7.10E-03 Specification MAX 8.80E-03 8.80E-03 8.80E-03 8.80E-03 8.80E-03 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 217 TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 0.00E+00 -Supply Current (A) @ VS=+5V -1.00E-03 -2.00E-03 -3.00E-03 -4.00E-03 -5.00E-03 -6.00E-03 -7.00E-03 -8.00E-03 -9.00E-03 -1.00E-02 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.104. Plot of -Supply Current (A) @ VS=+5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 218 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.104. Raw data for -Supply Current (A) @ VS=+5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Supply Current (A) @ VS=+5V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 -7.50E-03 -7.52E-03 -7.61E-03 -7.44E-03 -7.53E-03 -7.48E-03 -7.51E-03 -7.33E-03 -7.47E-03 -7.44E-03 -7.44E-03 -7.49E-03 Total 20 -7.38E-03 -7.41E-03 -7.52E-03 -7.33E-03 -7.47E-03 -7.43E-03 -7.46E-03 -7.28E-03 -7.42E-03 -7.40E-03 -7.40E-03 -7.47E-03 Dose (krad(Si)) 50 100 -7.39E-03 -7.31E-03 -7.35E-03 -7.33E-03 -7.46E-03 -7.43E-03 -7.28E-03 -7.24E-03 -7.38E-03 -7.35E-03 -7.40E-03 -7.36E-03 -7.42E-03 -7.40E-03 -7.25E-03 -7.22E-03 -7.39E-03 -7.36E-03 -7.36E-03 -7.33E-03 -7.40E-03 -7.40E-03 -7.47E-03 -7.47E-03 200 -7.28E-03 -7.37E-03 -7.40E-03 -7.23E-03 -7.37E-03 -7.31E-03 -7.35E-03 -7.17E-03 -7.31E-03 -7.28E-03 -7.41E-03 -7.48E-03 -7.52E-03 -7.42E-03 -7.37E-03 -7.33E-03 -7.33E-03 6.01E-05 7.51E-05 6.39E-05 6.77E-05 7.31E-05 -7.35E-03 -7.22E-03 -7.20E-03 -7.15E-03 -7.13E-03 -7.68E-03 -7.63E-03 -7.55E-03 -7.52E-03 -7.53E-03 -7.45E-03 6.89E-05 -7.26E-03 -7.64E-03 -8.80E-03 PASS -7.40E-03 6.91E-05 -7.21E-03 -7.59E-03 -8.80E-03 PASS -7.36E-03 6.67E-05 -7.18E-03 -7.55E-03 -8.80E-03 PASS -7.33E-03 6.81E-05 -7.15E-03 -7.52E-03 -8.80E-03 PASS An ISO 9001:2008 and DSCC Certified Company 219 -7.28E-03 6.83E-05 -7.10E-03 -7.47E-03 -8.80E-03 PASS Input Offset Voltage4 1 (V) @ VS=+5V, VCM=0V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.105. Plot of Input Offset Voltage4 1 (V) @ VS=+5V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 220 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.105. Raw data for Input Offset Voltage4 1 (V) @ VS=+5V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage4 1 (V) @ VS=+5V, VCM=0V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 8.30E-05 3.82E-04 -5.21E-05 -1.16E-04 1.08E-05 2.44E-05 -1.36E-04 6.81E-06 -2.32E-04 1.05E-04 -2.60E-04 -2.02E-04 Total 20 5.99E-05 3.47E-04 -6.61E-05 -1.42E-04 -1.03E-05 4.64E-06 -1.51E-04 6.69E-06 -2.35E-04 8.73E-05 -2.62E-04 -2.02E-04 Dose (krad(Si)) 50 100 6.98E-05 6.08E-05 3.45E-04 3.36E-04 -7.44E-05 -8.04E-05 -1.39E-04 -1.48E-04 -7.91E-06 2.11E-06 -3.56E-06 -1.66E-05 -1.58E-04 -1.70E-04 -6.58E-06 -2.24E-05 -2.44E-04 -2.53E-04 7.54E-05 6.34E-05 -2.63E-04 -2.62E-04 -2.03E-04 -2.02E-04 200 6.13E-05 3.22E-04 -8.95E-05 -1.56E-04 1.38E-06 -4.41E-05 -1.94E-04 -4.47E-05 -2.78E-04 4.21E-05 -2.63E-04 -2.02E-04 6.16E-05 3.76E-05 3.86E-05 3.41E-05 2.79E-05 1.94E-04 1.88E-04 1.88E-04 1.86E-04 1.84E-04 5.93E-04 5.53E-04 5.54E-04 5.45E-04 5.33E-04 -4.69E-04 -4.78E-04 -4.77E-04 -4.77E-04 -4.78E-04 -4.64E-05 1.35E-04 3.25E-04 -4.18E-04 -8.00E-04 PASS 8.00E-04 PASS -5.74E-05 1.31E-04 3.03E-04 -4.18E-04 -9.50E-04 PASS 9.50E-04 PASS -6.72E-05 1.30E-04 2.89E-04 -4.23E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 221 -7.98E-05 1.29E-04 2.73E-04 -4.32E-04 -9.50E-04 PASS 9.50E-04 PASS -1.04E-04 1.29E-04 2.50E-04 -4.57E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Voltage4 2 (V) @ VS=+5V, VCM=0V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.106. Plot of Input Offset Voltage4 2 (V) @ VS=+5V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 222 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.106. Raw data for Input Offset Voltage4 2 (V) @ VS=+5V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage4 2 (V) @ VS=+5V, VCM=0V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -1.62E-04 2.07E-04 -4.04E-04 -3.06E-04 2.91E-04 1.70E-04 -3.87E-04 -1.87E-04 -1.07E-04 -1.13E-04 6.84E-05 -6.10E-05 Total 20 -2.06E-04 1.96E-04 -4.41E-04 -3.24E-04 2.59E-04 1.49E-04 -4.16E-04 -2.00E-04 -1.16E-04 -1.36E-04 6.13E-05 -6.03E-05 Dose (krad(Si)) 50 100 -1.97E-04 -2.02E-04 1.95E-04 1.93E-04 -4.34E-04 -4.29E-04 -3.14E-04 -3.09E-04 2.46E-04 2.54E-04 1.41E-04 1.33E-04 -4.21E-04 -4.33E-04 -1.97E-04 -1.97E-04 -1.23E-04 -1.35E-04 -1.43E-04 -1.55E-04 6.07E-05 6.11E-05 -6.18E-05 -6.01E-05 200 -2.09E-04 1.92E-04 -4.25E-04 -3.03E-04 2.54E-04 1.10E-04 -4.44E-04 -2.11E-04 -1.50E-04 -1.68E-04 6.21E-05 -5.92E-05 -7.49E-05 -1.03E-04 -1.01E-04 -9.86E-05 -9.81E-05 3.09E-04 3.14E-04 3.06E-04 3.05E-04 3.04E-04 7.72E-04 7.57E-04 7.37E-04 7.39E-04 7.34E-04 -9.22E-04 -9.64E-04 -9.39E-04 -9.36E-04 -9.31E-04 -1.25E-04 2.00E-04 4.23E-04 -6.73E-04 -8.00E-04 PASS 8.00E-04 PASS -1.44E-04 2.02E-04 4.11E-04 -6.99E-04 -9.50E-04 PASS 9.50E-04 PASS -1.49E-04 2.01E-04 4.02E-04 -6.99E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 223 -1.57E-04 2.01E-04 3.95E-04 -7.09E-04 -9.50E-04 PASS 9.50E-04 PASS -1.73E-04 1.97E-04 3.68E-04 -7.13E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Voltage4 3 (V) @ VS=+5V, VCM=0V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.107. Plot of Input Offset Voltage4 3 (V) @ VS=+5V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 224 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.107. Raw data for Input Offset Voltage4 3 (V) @ VS=+5V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage4 3 (V) @ VS=+5V, VCM=0V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -3.33E-06 1.20E-04 -2.23E-04 5.70E-05 -1.47E-05 -5.24E-04 4.42E-05 -1.22E-04 -5.68E-05 1.61E-04 1.84E-04 4.85E-05 Total 20 2.83E-06 8.56E-05 -2.49E-04 4.29E-05 -4.62E-05 -5.40E-04 9.71E-06 -1.39E-04 -3.56E-05 1.42E-04 1.79E-04 4.79E-05 Dose (krad(Si)) 50 100 6.70E-06 6.57E-06 7.96E-05 7.38E-05 -2.46E-04 -2.48E-04 4.05E-05 3.62E-05 -7.09E-05 -8.12E-05 -5.46E-04 -5.56E-04 2.47E-06 -1.11E-05 -1.47E-04 -1.64E-04 -4.76E-05 -6.39E-05 1.27E-04 1.06E-04 1.78E-04 1.79E-04 4.76E-05 4.79E-05 200 1.06E-05 6.68E-05 -2.48E-04 2.96E-05 -9.50E-05 -5.86E-04 -2.75E-05 -1.87E-04 -8.22E-05 7.99E-05 1.81E-04 4.94E-05 -1.26E-05 -3.27E-05 -3.80E-05 -4.26E-05 -4.72E-05 1.29E-04 1.30E-04 1.29E-04 1.28E-04 1.27E-04 3.42E-04 3.25E-04 3.15E-04 3.09E-04 3.02E-04 -3.67E-04 -3.90E-04 -3.91E-04 -3.95E-04 -3.96E-04 -9.96E-05 2.61E-04 6.15E-04 -8.14E-04 -8.00E-04 PASS 8.00E-04 PASS -1.12E-04 2.59E-04 5.98E-04 -8.23E-04 -9.50E-04 PASS 9.50E-04 PASS -1.22E-04 2.57E-04 5.82E-04 -8.26E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 225 -1.38E-04 2.53E-04 5.56E-04 -8.32E-04 -9.50E-04 PASS 9.50E-04 PASS -1.61E-04 2.57E-04 5.43E-04 -8.64E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Voltage4 4 (V) @ VS=+5V, VCM=0V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.108. Plot of Input Offset Voltage4 4 (V) @ VS=+5V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 226 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.108. Raw data for Input Offset Voltage4 4 (V) @ VS=+5V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage4 4 (V) @ VS=+5V, VCM=0V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 1.20E-05 9.13E-05 2.64E-04 7.04E-05 1.92E-04 -5.66E-05 -7.37E-05 2.55E-04 1.43E-05 3.93E-05 4.74E-04 -1.15E-05 Total 20 -1.14E-05 4.33E-05 2.21E-04 5.49E-05 1.65E-04 -5.75E-05 -7.82E-05 2.46E-04 1.21E-05 2.09E-05 4.67E-04 -1.12E-05 Dose (krad(Si)) 50 100 -4.65E-06 -7.07E-06 4.42E-05 3.78E-05 2.23E-04 2.18E-04 6.40E-05 6.37E-05 1.61E-04 1.71E-04 -6.33E-05 -7.09E-05 -8.22E-05 -8.81E-05 2.44E-04 2.30E-04 5.01E-06 -7.31E-06 1.36E-05 3.68E-06 4.64E-04 4.65E-04 -1.15E-05 -9.84E-06 200 -8.27E-06 3.76E-05 2.16E-04 6.61E-05 1.75E-04 -8.93E-05 -1.01E-04 2.13E-04 -2.25E-05 -4.65E-06 4.68E-04 -9.84E-06 1.26E-04 9.45E-05 9.76E-05 9.68E-05 9.72E-05 1.01E-04 9.53E-05 9.24E-05 9.44E-05 9.46E-05 4.02E-04 3.56E-04 3.51E-04 3.55E-04 3.57E-04 -1.50E-04 -1.67E-04 -1.56E-04 -1.62E-04 -1.62E-04 3.57E-05 1.31E-04 3.96E-04 -3.25E-04 -8.00E-04 PASS 8.00E-04 PASS 2.87E-05 1.29E-04 3.82E-04 -3.25E-04 -9.50E-04 PASS 9.50E-04 PASS 2.35E-05 1.30E-04 3.81E-04 -3.34E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 227 1.34E-05 1.27E-04 3.62E-04 -3.35E-04 -9.50E-04 PASS 9.50E-04 PASS -1.08E-06 1.26E-04 3.46E-04 -3.48E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Current4 1 (A) @ VS=+5V, VCM=0V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 8.00E-08 6.00E-08 4.00E-08 2.00E-08 0.00E+00 -2.00E-08 -4.00E-08 -6.00E-08 -8.00E-08 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.109. Plot of Input Offset Current4 1 (A) @ VS=+5V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 228 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.109. Raw data for Input Offset Current4 1 (A) @ VS=+5V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current4 1 (A) @ VS=+5V, VCM=0V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 4.86E-09 3.15E-09 -6.50E-10 -2.82E-09 3.60E-10 1.78E-09 8.40E-10 -2.70E-09 -6.85E-09 -4.40E-10 -7.90E-10 -6.22E-09 Total 20 5.21E-09 2.15E-09 -1.02E-09 -3.26E-09 2.00E-10 1.85E-09 7.20E-10 -2.77E-09 -6.83E-09 -1.14E-09 -7.90E-10 -6.23E-09 Dose (krad(Si)) 50 100 5.31E-09 6.56E-09 2.35E-09 2.85E-09 -1.14E-09 -5.60E-10 -1.70E-09 -2.67E-09 -3.20E-10 8.50E-10 2.39E-09 3.10E-09 1.52E-09 1.60E-09 -3.01E-09 -2.94E-09 -7.95E-09 -7.61E-09 -1.41E-09 -1.23E-09 -7.70E-10 -8.00E-10 -6.26E-09 -6.29E-09 200 7.51E-09 1.26E-09 -2.60E-10 -3.49E-09 1.10E-09 4.70E-09 9.00E-10 -2.70E-09 -1.04E-08 -1.37E-09 -7.50E-10 -6.24E-09 9.80E-10 6.56E-10 9.00E-10 1.41E-09 1.22E-09 3.05E-09 3.21E-09 2.91E-09 3.52E-09 4.00E-09 9.35E-09 9.47E-09 8.89E-09 1.10E-08 1.22E-08 -7.39E-09 -8.16E-09 -7.09E-09 -8.23E-09 -9.74E-09 -1.47E-09 3.44E-09 7.97E-09 -1.09E-08 -6.50E-08 PASS 6.50E-08 PASS -1.63E-09 3.40E-09 7.69E-09 -1.10E-08 -6.50E-08 PASS 6.50E-08 PASS -1.69E-09 4.12E-09 9.61E-09 -1.30E-08 -6.50E-08 PASS 6.50E-08 PASS An ISO 9001:2008 and DSCC Certified Company 229 -1.42E-09 4.19E-09 1.01E-08 -1.29E-08 -6.50E-08 PASS 6.50E-08 PASS -1.76E-09 5.56E-09 1.35E-08 -1.70E-08 -6.50E-08 PASS 6.50E-08 PASS Input Offset Current4 2 (A) @ VS=+5V, VCM=0V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 8.00E-08 6.00E-08 4.00E-08 2.00E-08 0.00E+00 -2.00E-08 -4.00E-08 -6.00E-08 -8.00E-08 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.110. Plot of Input Offset Current4 2 (A) @ VS=+5V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 230 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.110. Raw data for Input Offset Current4 2 (A) @ VS=+5V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current4 2 (A) @ VS=+5V, VCM=0V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 9.80E-10 -1.58E-09 1.83E-09 -1.93E-09 9.00E-10 5.33E-09 -4.95E-09 -1.31E-09 2.72E-09 -5.49E-09 -1.54E-09 6.72E-09 Total 20 9.00E-11 -1.93E-09 8.60E-10 -2.05E-09 1.12E-09 5.70E-09 -5.35E-09 -1.26E-09 2.66E-09 -5.35E-09 -1.51E-09 6.80E-09 Dose (krad(Si)) 50 100 -5.00E-11 -2.10E-10 -2.36E-09 -1.80E-09 2.02E-09 1.14E-09 -2.90E-09 -1.56E-09 6.30E-10 1.38E-09 5.18E-09 6.29E-09 -5.47E-09 -5.91E-09 -8.70E-10 -1.14E-09 2.88E-09 3.15E-09 -5.14E-09 -4.78E-09 -1.52E-09 -1.48E-09 6.89E-09 6.88E-09 200 -2.20E-10 -2.23E-09 8.20E-10 -1.35E-09 2.46E-09 5.77E-09 -5.01E-09 -1.12E-09 2.34E-09 -4.52E-09 -1.53E-09 6.78E-09 4.00E-11 -3.82E-10 -5.32E-10 -2.10E-10 -1.04E-10 1.68E-09 1.52E-09 2.06E-09 1.47E-09 1.84E-09 4.66E-09 3.78E-09 5.13E-09 3.83E-09 4.94E-09 -4.58E-09 -4.54E-09 -6.19E-09 -4.25E-09 -5.14E-09 -7.40E-10 4.73E-09 1.22E-08 -1.37E-08 -6.50E-08 PASS 6.50E-08 PASS -7.20E-10 4.89E-09 1.27E-08 -1.41E-08 -6.50E-08 PASS 6.50E-08 PASS -6.84E-10 4.74E-09 1.23E-08 -1.37E-08 -6.50E-08 PASS 6.50E-08 PASS An ISO 9001:2008 and DSCC Certified Company 231 -4.78E-10 5.18E-09 1.37E-08 -1.47E-08 -6.50E-08 PASS 6.50E-08 PASS -5.08E-10 4.59E-09 1.21E-08 -1.31E-08 -6.50E-08 PASS 6.50E-08 PASS Input Offset Current4 3 (A) @ VS=+5V, VCM=0V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 8.00E-08 6.00E-08 4.00E-08 2.00E-08 0.00E+00 -2.00E-08 -4.00E-08 -6.00E-08 -8.00E-08 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.111. Plot of Input Offset Current4 3 (A) @ VS=+5V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 232 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.111. Raw data for Input Offset Current4 3 (A) @ VS=+5V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current4 3 (A) @ VS=+5V, VCM=0V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 2.59E-09 -3.20E-10 -1.62E-09 -1.10E-10 -4.29E-09 -3.10E-09 -1.89E-09 6.20E-10 4.48E-09 -2.79E-09 -1.35E-09 -8.40E-10 Total 20 3.39E-09 5.00E-10 -1.17E-09 8.30E-10 -4.10E-09 -3.36E-09 -2.06E-09 4.50E-10 4.58E-09 -2.76E-09 -1.36E-09 -8.60E-10 Dose (krad(Si)) 50 100 3.76E-09 3.92E-09 1.30E-10 -2.10E-10 -1.00E-09 -1.38E-09 2.60E-10 1.69E-09 -4.52E-09 -5.41E-09 -3.74E-09 -3.19E-09 -1.55E-09 -8.60E-10 6.00E-10 5.10E-10 4.77E-09 4.54E-09 -2.94E-09 -4.58E-09 -1.44E-09 -1.35E-09 -9.00E-10 -9.10E-10 200 4.45E-09 -4.00E-11 -9.80E-10 3.96E-09 -5.33E-09 -3.37E-09 -7.60E-10 1.81E-09 4.46E-09 -5.66E-09 -1.36E-09 -9.10E-10 -7.50E-10 -1.10E-10 -2.74E-10 -2.78E-10 4.12E-10 2.50E-09 2.76E-09 2.97E-09 3.50E-09 4.00E-09 6.11E-09 7.47E-09 7.87E-09 9.32E-09 1.14E-08 -7.61E-09 -7.69E-09 -8.42E-09 -9.88E-09 -1.06E-08 -5.36E-10 3.16E-09 8.13E-09 -9.21E-09 -6.50E-08 PASS 6.50E-08 PASS -6.30E-10 3.25E-09 8.29E-09 -9.55E-09 -6.50E-08 PASS 6.50E-08 PASS -5.72E-10 3.41E-09 8.78E-09 -9.92E-09 -6.50E-08 PASS 6.50E-08 PASS An ISO 9001:2008 and DSCC Certified Company 233 -7.16E-10 3.54E-09 9.00E-09 -1.04E-08 -6.50E-08 PASS 6.50E-08 PASS -7.04E-10 4.02E-09 1.03E-08 -1.17E-08 -6.50E-08 PASS 6.50E-08 PASS Input Offset Current4 4 (A) @ VS=+5V, VCM=0V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 8.00E-08 6.00E-08 4.00E-08 2.00E-08 0.00E+00 -2.00E-08 -4.00E-08 -6.00E-08 -8.00E-08 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.112. Plot of Input Offset Current4 4 (A) @ VS=+5V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 234 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.112. Raw data for Input Offset Current4 4 (A) @ VS=+5V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current4 4 (A) @ VS=+5V, VCM=0V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 1.81E-09 7.10E-10 -3.56E-09 -4.20E-10 3.27E-09 -1.39E-09 3.03E-09 2.06E-09 3.11E-09 6.07E-09 -2.76E-09 -3.95E-09 Total 20 1.83E-09 8.80E-10 -4.02E-09 -3.50E-10 3.83E-09 -1.38E-09 2.92E-09 1.32E-09 3.72E-09 6.14E-09 -2.89E-09 -3.98E-09 Dose (krad(Si)) 50 100 200 2.28E-09 1.81E-09 8.70E-10 1.12E-09 4.40E-10 4.10E-10 -2.94E-09 -3.19E-09 -2.19E-09 1.20E-10 -6.00E-11 4.90E-10 5.16E-09 6.99E-09 8.17E-09 -4.30E-10 3.30E-10 8.20E-10 3.04E-09 3.84E-09 2.81E-09 1.00E-09 1.28E-09 1.90E-10 4.66E-09 4.48E-09 4.49E-09 6.32E-09 6.29E-09 8.06E-09 -2.83E-09 -2.84E-09 -2.86E-09 -4.00E-09 -3.98E-09 -3.86E-09 3.62E-10 4.34E-10 1.15E-09 1.20E-09 1.55E-09 2.58E-09 2.92E-09 2.96E-09 3.72E-09 3.90E-09 7.44E-09 8.44E-09 9.28E-09 1.14E-08 1.22E-08 -6.72E-09 -7.58E-09 -6.98E-09 -9.00E-09 -9.13E-09 2.58E-09 2.68E-09 9.92E-09 -4.77E-09 -6.50E-08 PASS 6.50E-08 PASS 2.54E-09 2.80E-09 1.02E-08 -5.13E-09 -6.50E-08 PASS 6.50E-08 PASS 2.92E-09 2.72E-09 1.04E-08 -4.53E-09 -6.50E-08 PASS 6.50E-08 PASS An ISO 9001:2008 and DSCC Certified Company 235 3.24E-09 2.42E-09 9.89E-09 -3.40E-09 -6.50E-08 PASS 6.50E-08 PASS 3.27E-09 3.17E-09 1.20E-08 -5.41E-09 -6.50E-08 PASS 6.50E-08 PASS +Input Bias Current BIAS4 1 (A) @ VS=+5V, VCM=0V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-06 1.00E-06 5.00E-07 0.00E+00 -5.00E-07 -1.00E-06 -1.50E-06 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.113. Plot of +Input Bias Current BIAS4 1 (A) @ VS=+5V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 236 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.113. Raw data for +Input Bias Current BIAS4 1 (A) @ VS=+5V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Input Bias Current BIAS4 1 (A) @ VS=+5V, VCM=0V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -3.03E-07 -3.14E-07 -3.17E-07 -3.10E-07 -2.97E-07 -2.93E-07 -3.12E-07 -2.89E-07 -2.93E-07 -3.07E-07 -3.09E-07 -3.13E-07 Total 20 -3.16E-07 -3.28E-07 -3.30E-07 -3.24E-07 -3.11E-07 -3.05E-07 -3.25E-07 -3.02E-07 -3.05E-07 -3.20E-07 -3.12E-07 -3.14E-07 Dose (krad(Si)) 50 100 -3.24E-07 -3.41E-07 -3.45E-07 -3.59E-07 -3.47E-07 -3.63E-07 -3.37E-07 -3.55E-07 -3.25E-07 -3.45E-07 -3.21E-07 -3.47E-07 -3.46E-07 -3.67E-07 -3.17E-07 -3.38E-07 -3.22E-07 -3.48E-07 -3.37E-07 -3.62E-07 -3.12E-07 -3.12E-07 -3.14E-07 -3.14E-07 200 -3.69E-07 -3.89E-07 -3.92E-07 -3.82E-07 -3.72E-07 -3.78E-07 -4.00E-07 -3.76E-07 -3.81E-07 -3.95E-07 -3.11E-07 -3.13E-07 -3.08E-07 -3.22E-07 -3.36E-07 -3.53E-07 -3.81E-07 8.26E-09 8.13E-09 1.09E-08 9.51E-09 1.02E-08 -2.85E-07 -2.99E-07 -3.06E-07 -3.27E-07 -3.53E-07 -3.31E-07 -3.44E-07 -3.66E-07 -3.79E-07 -4.09E-07 -2.99E-07 1.04E-08 -2.70E-07 -3.27E-07 -6.50E-07 PASS 6.50E-07 PASS -3.12E-07 1.06E-08 -2.82E-07 -3.41E-07 -7.50E-07 PASS 7.50E-07 PASS -3.29E-07 1.21E-08 -2.95E-07 -3.62E-07 -8.00E-07 PASS 8.00E-07 PASS An ISO 9001:2008 and DSCC Certified Company 237 -3.52E-07 1.19E-08 -3.20E-07 -3.85E-07 -8.50E-07 PASS 8.50E-07 PASS -3.86E-07 1.07E-08 -3.56E-07 -4.15E-07 -9.50E-07 PASS 9.50E-07 PASS +Input Bias Current BIAS4 2 (A) @ VS=+5V, VCM=0V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-06 1.00E-06 5.00E-07 0.00E+00 -5.00E-07 -1.00E-06 -1.50E-06 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.114. Plot of +Input Bias Current BIAS4 2 (A) @ VS=+5V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 238 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.114. Raw data for +Input Bias Current BIAS4 2 (A) @ VS=+5V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Input Bias Current BIAS4 2 (A) @ VS=+5V, VCM=0V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -3.12E-07 -2.98E-07 -3.34E-07 -3.13E-07 -2.84E-07 -2.95E-07 -3.07E-07 -2.92E-07 -3.15E-07 -3.12E-07 -2.85E-07 -3.11E-07 Total 20 -3.24E-07 -3.09E-07 -3.49E-07 -3.26E-07 -2.96E-07 -3.06E-07 -3.20E-07 -3.04E-07 -3.27E-07 -3.23E-07 -2.87E-07 -3.12E-07 Dose (krad(Si)) 50 100 -3.31E-07 -3.49E-07 -3.21E-07 -3.32E-07 -3.60E-07 -3.72E-07 -3.37E-07 -3.51E-07 -3.05E-07 -3.17E-07 -3.20E-07 -3.38E-07 -3.34E-07 -3.58E-07 -3.16E-07 -3.34E-07 -3.46E-07 -3.66E-07 -3.37E-07 -3.60E-07 -2.88E-07 -2.87E-07 -3.12E-07 -3.12E-07 200 -3.71E-07 -3.62E-07 -3.95E-07 -3.74E-07 -3.38E-07 -3.69E-07 -3.83E-07 -3.64E-07 -3.94E-07 -3.91E-07 -2.87E-07 -3.11E-07 -3.08E-07 -3.21E-07 -3.31E-07 -3.44E-07 -3.68E-07 1.86E-08 1.97E-08 2.02E-08 2.08E-08 2.05E-08 -2.57E-07 -2.67E-07 -2.75E-07 -2.87E-07 -3.12E-07 -3.59E-07 -3.75E-07 -3.86E-07 -4.01E-07 -4.24E-07 -3.04E-07 1.02E-08 -2.76E-07 -3.32E-07 -6.50E-07 PASS 6.50E-07 PASS -3.16E-07 1.05E-08 -2.87E-07 -3.45E-07 -7.50E-07 PASS 7.50E-07 PASS -3.31E-07 1.24E-08 -2.97E-07 -3.65E-07 -8.00E-07 PASS 8.00E-07 PASS An ISO 9001:2008 and DSCC Certified Company 239 -3.51E-07 1.40E-08 -3.13E-07 -3.90E-07 -8.50E-07 PASS 8.50E-07 PASS -3.80E-07 1.33E-08 -3.44E-07 -4.17E-07 -9.50E-07 PASS 9.50E-07 PASS +Input Bias Current BIAS4 3 (A) @ VS=+5V, VCM=0V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-06 1.00E-06 5.00E-07 0.00E+00 -5.00E-07 -1.00E-06 -1.50E-06 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.115. Plot of +Input Bias Current BIAS4 3 (A) @ VS=+5V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 240 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.115. Raw data for +Input Bias Current BIAS4 3 (A) @ VS=+5V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Input Bias Current BIAS4 3 (A) @ VS=+5V, VCM=0V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -3.09E-07 -2.93E-07 -3.35E-07 -3.10E-07 -2.88E-07 -2.97E-07 -3.07E-07 -2.97E-07 -3.13E-07 -3.10E-07 -2.86E-07 -3.12E-07 Total 20 -3.22E-07 -3.06E-07 -3.52E-07 -3.23E-07 -3.01E-07 -3.10E-07 -3.20E-07 -3.10E-07 -3.25E-07 -3.23E-07 -2.88E-07 -3.13E-07 Dose (krad(Si)) 50 100 -3.30E-07 -3.48E-07 -3.19E-07 -3.33E-07 -3.64E-07 -3.77E-07 -3.35E-07 -3.52E-07 -3.12E-07 -3.28E-07 -3.26E-07 -3.51E-07 -3.36E-07 -3.63E-07 -3.25E-07 -3.50E-07 -3.41E-07 -3.66E-07 -3.40E-07 -3.68E-07 -2.88E-07 -2.88E-07 -3.13E-07 -3.13E-07 200 -3.72E-07 -3.64E-07 -4.01E-07 -3.75E-07 -3.56E-07 -3.81E-07 -3.95E-07 -3.78E-07 -3.97E-07 -4.03E-07 -2.87E-07 -3.12E-07 -3.07E-07 -3.21E-07 -3.32E-07 -3.48E-07 -3.74E-07 1.85E-08 2.00E-08 1.97E-08 1.94E-08 1.67E-08 -2.56E-07 -2.66E-07 -2.78E-07 -2.94E-07 -3.28E-07 -3.58E-07 -3.76E-07 -3.86E-07 -4.01E-07 -4.19E-07 -3.05E-07 7.43E-09 -2.84E-07 -3.25E-07 -6.50E-07 PASS 6.50E-07 PASS -3.18E-07 7.27E-09 -2.98E-07 -3.38E-07 -7.50E-07 PASS 7.50E-07 PASS -3.34E-07 7.64E-09 -3.13E-07 -3.55E-07 -8.00E-07 PASS 8.00E-07 PASS An ISO 9001:2008 and DSCC Certified Company 241 -3.60E-07 8.64E-09 -3.36E-07 -3.84E-07 -8.50E-07 PASS 8.50E-07 PASS -3.91E-07 1.06E-08 -3.62E-07 -4.20E-07 -9.50E-07 PASS 9.50E-07 PASS +Input Bias Current BIAS4 4 (A) @ VS=+5V, VCM=0V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-06 1.00E-06 5.00E-07 0.00E+00 -5.00E-07 -1.00E-06 -1.50E-06 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.116. Plot of +Input Bias Current BIAS4 4 (A) @ VS=+5V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 242 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.116. Raw data for +Input Bias Current BIAS4 4 (A) @ VS=+5V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Input Bias Current BIAS4 4 (A) @ VS=+5V, VCM=0V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -3.05E-07 -3.18E-07 -3.19E-07 -3.11E-07 -2.96E-07 -2.92E-07 -3.10E-07 -2.87E-07 -2.90E-07 -3.10E-07 -3.13E-07 -3.16E-07 Total 20 -3.17E-07 -3.29E-07 -3.30E-07 -3.24E-07 -3.08E-07 -3.03E-07 -3.22E-07 -2.99E-07 -3.00E-07 -3.21E-07 -3.16E-07 -3.17E-07 Dose (krad(Si)) 50 100 -3.24E-07 -3.40E-07 -3.40E-07 -3.55E-07 -3.47E-07 -3.61E-07 -3.35E-07 -3.53E-07 -3.18E-07 -3.32E-07 -3.17E-07 -3.34E-07 -3.35E-07 -3.57E-07 -3.12E-07 -3.30E-07 -3.13E-07 -3.31E-07 -3.36E-07 -3.59E-07 -3.16E-07 -3.16E-07 -3.17E-07 -3.17E-07 200 -3.64E-07 -3.82E-07 -3.83E-07 -3.76E-07 -3.61E-07 -3.63E-07 -3.86E-07 -3.63E-07 -3.64E-07 -3.88E-07 -3.16E-07 -3.16E-07 -3.10E-07 -3.22E-07 -3.33E-07 -3.48E-07 -3.73E-07 9.34E-09 9.09E-09 1.17E-08 1.19E-08 1.04E-08 -2.84E-07 -2.97E-07 -3.01E-07 -3.15E-07 -3.45E-07 -3.35E-07 -3.47E-07 -3.65E-07 -3.81E-07 -4.02E-07 -2.98E-07 1.13E-08 -2.67E-07 -3.29E-07 -6.50E-07 PASS 6.50E-07 PASS -3.09E-07 1.14E-08 -2.78E-07 -3.40E-07 -7.50E-07 PASS 7.50E-07 PASS -3.22E-07 1.20E-08 -2.90E-07 -3.55E-07 -8.00E-07 PASS 8.00E-07 PASS An ISO 9001:2008 and DSCC Certified Company 243 -3.42E-07 1.47E-08 -3.02E-07 -3.82E-07 -8.50E-07 PASS 8.50E-07 PASS -3.73E-07 1.28E-08 -3.38E-07 -4.08E-07 -9.50E-07 PASS 9.50E-07 PASS -Input Bias Current BIAS4 1 (A) @ VS=+5V, VCM=0V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-06 1.00E-06 5.00E-07 0.00E+00 -5.00E-07 -1.00E-06 -1.50E-06 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.117. Plot of -Input Bias Current BIAS4 1 (A) @ VS=+5V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 244 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.117. Raw data for -Input Bias Current BIAS4 1 (A) @ VS=+5V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Input Bias Current BIAS4 1 (A) @ VS=+5V, VCM=0V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -3.09E-07 -3.19E-07 -3.17E-07 -3.08E-07 -2.98E-07 -2.96E-07 -3.15E-07 -2.87E-07 -2.87E-07 -3.08E-07 -3.10E-07 -3.08E-07 Total 20 -3.23E-07 -3.32E-07 -3.31E-07 -3.23E-07 -3.12E-07 -3.08E-07 -3.28E-07 -3.00E-07 -3.00E-07 -3.21E-07 -3.13E-07 -3.09E-07 Dose (krad(Si)) 50 100 -3.31E-07 -3.51E-07 -3.48E-07 -3.63E-07 -3.49E-07 -3.65E-07 -3.37E-07 -3.53E-07 -3.26E-07 -3.48E-07 -3.25E-07 -3.51E-07 -3.47E-07 -3.70E-07 -3.16E-07 -3.37E-07 -3.16E-07 -3.37E-07 -3.36E-07 -3.62E-07 -3.13E-07 -3.13E-07 -3.09E-07 -3.09E-07 200 -3.78E-07 -3.93E-07 -3.92E-07 -3.80E-07 -3.75E-07 -3.83E-07 -4.00E-07 -3.74E-07 -3.71E-07 -3.93E-07 -3.12E-07 -3.08E-07 -3.10E-07 -3.24E-07 -3.38E-07 -3.56E-07 -3.83E-07 8.17E-09 7.78E-09 1.03E-08 7.62E-09 8.28E-09 -2.88E-07 -3.03E-07 -3.10E-07 -3.35E-07 -3.61E-07 -3.33E-07 -3.45E-07 -3.66E-07 -3.77E-07 -4.06E-07 -2.99E-07 1.24E-08 -2.65E-07 -3.33E-07 -6.50E-07 PASS 6.50E-07 PASS -3.11E-07 1.26E-08 -2.77E-07 -3.46E-07 -7.50E-07 PASS 7.50E-07 PASS -3.28E-07 1.35E-08 -2.91E-07 -3.65E-07 -8.00E-07 PASS 8.00E-07 PASS An ISO 9001:2008 and DSCC Certified Company 245 -3.51E-07 1.48E-08 -3.11E-07 -3.92E-07 -8.50E-07 PASS 8.50E-07 PASS -3.84E-07 1.23E-08 -3.50E-07 -4.18E-07 -9.50E-07 PASS 9.50E-07 PASS -Input Bias Current BIAS4 2 (A) @ VS=+5V, VCM=0V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-06 1.00E-06 5.00E-07 0.00E+00 -5.00E-07 -1.00E-06 -1.50E-06 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.118. Plot of -Input Bias Current BIAS4 2 (A) @ VS=+5V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 246 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.118. Raw data for -Input Bias Current BIAS4 2 (A) @ VS=+5V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Input Bias Current BIAS4 2 (A) @ VS=+5V, VCM=0V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -3.14E-07 -2.98E-07 -3.37E-07 -3.13E-07 -2.86E-07 -3.02E-07 -3.04E-07 -2.92E-07 -3.20E-07 -3.08E-07 -2.85E-07 -3.19E-07 Total 20 -3.26E-07 -3.09E-07 -3.52E-07 -3.26E-07 -2.98E-07 -3.13E-07 -3.16E-07 -3.04E-07 -3.31E-07 -3.19E-07 -2.87E-07 -3.21E-07 Dose (krad(Si)) 50 100 -3.33E-07 -3.49E-07 -3.20E-07 -3.32E-07 -3.62E-07 -3.76E-07 -3.36E-07 -3.52E-07 -3.07E-07 -3.20E-07 -3.27E-07 -3.51E-07 -3.30E-07 -3.52E-07 -3.17E-07 -3.34E-07 -3.50E-07 -3.69E-07 -3.33E-07 -3.56E-07 -2.87E-07 -2.87E-07 -3.21E-07 -3.20E-07 200 -3.72E-07 -3.60E-07 -3.97E-07 -3.73E-07 -3.45E-07 -3.76E-07 -3.81E-07 -3.63E-07 -3.96E-07 -3.88E-07 -2.87E-07 -3.20E-07 -3.10E-07 -3.22E-07 -3.32E-07 -3.46E-07 -3.69E-07 1.93E-08 2.04E-08 2.06E-08 2.11E-08 1.92E-08 -2.57E-07 -2.66E-07 -2.75E-07 -2.88E-07 -3.17E-07 -3.63E-07 -3.78E-07 -3.88E-07 -4.04E-07 -4.22E-07 -3.05E-07 9.98E-09 -2.78E-07 -3.32E-07 -6.50E-07 PASS 6.50E-07 PASS -3.17E-07 1.00E-08 -2.89E-07 -3.44E-07 -7.50E-07 PASS 7.50E-07 PASS -3.31E-07 1.19E-08 -2.99E-07 -3.64E-07 -8.00E-07 PASS 8.00E-07 PASS An ISO 9001:2008 and DSCC Certified Company 247 -3.53E-07 1.24E-08 -3.18E-07 -3.87E-07 -8.50E-07 PASS 8.50E-07 PASS -3.81E-07 1.26E-08 -3.46E-07 -4.15E-07 -9.50E-07 PASS 9.50E-07 PASS -Input Bias Current BIAS4 3 (A) @ VS=+5V, VCM=0V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-06 1.00E-06 5.00E-07 0.00E+00 -5.00E-07 -1.00E-06 -1.50E-06 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.119. Plot of -Input Bias Current BIAS4 3 (A) @ VS=+5V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 248 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.119. Raw data for -Input Bias Current BIAS4 3 (A) @ VS=+5V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Input Bias Current BIAS4 3 (A) @ VS=+5V, VCM=0V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -3.13E-07 -2.94E-07 -3.35E-07 -3.11E-07 -2.85E-07 -2.95E-07 -3.07E-07 -2.99E-07 -3.19E-07 -3.09E-07 -2.85E-07 -3.12E-07 Total 20 -3.27E-07 -3.08E-07 -3.52E-07 -3.26E-07 -2.98E-07 -3.08E-07 -3.20E-07 -3.12E-07 -3.31E-07 -3.22E-07 -2.88E-07 -3.13E-07 Dose (krad(Si)) 50 100 -3.35E-07 -3.53E-07 -3.21E-07 -3.35E-07 -3.64E-07 -3.78E-07 -3.37E-07 -3.53E-07 -3.09E-07 -3.24E-07 -3.24E-07 -3.50E-07 -3.37E-07 -3.63E-07 -3.27E-07 -3.53E-07 -3.52E-07 -3.72E-07 -3.39E-07 -3.63E-07 -2.88E-07 -2.88E-07 -3.13E-07 -3.13E-07 200 -3.79E-07 -3.66E-07 -4.01E-07 -3.80E-07 -3.52E-07 -3.80E-07 -3.94E-07 -3.81E-07 -4.03E-07 -3.97E-07 -2.88E-07 -3.12E-07 -3.08E-07 -3.22E-07 -3.33E-07 -3.48E-07 -3.76E-07 1.94E-08 2.09E-08 2.06E-08 2.05E-08 1.82E-08 -2.54E-07 -2.65E-07 -2.77E-07 -2.92E-07 -3.26E-07 -3.61E-07 -3.79E-07 -3.90E-07 -4.05E-07 -4.26E-07 -3.06E-07 9.13E-09 -2.81E-07 -3.31E-07 -6.50E-07 PASS 6.50E-07 PASS -3.18E-07 9.10E-09 -2.94E-07 -3.43E-07 -7.50E-07 PASS 7.50E-07 PASS -3.36E-07 1.11E-08 -3.05E-07 -3.66E-07 -8.00E-07 PASS 8.00E-07 PASS An ISO 9001:2008 and DSCC Certified Company 249 -3.60E-07 8.75E-09 -3.36E-07 -3.84E-07 -8.50E-07 PASS 8.50E-07 PASS -3.91E-07 1.04E-08 -3.62E-07 -4.19E-07 -9.50E-07 PASS 9.50E-07 PASS -Input Bias Current BIAS4 4 (A) @ VS=+5V, VCM=0V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-06 1.00E-06 5.00E-07 0.00E+00 -5.00E-07 -1.00E-06 -1.50E-06 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.120. Plot of -Input Bias Current BIAS4 4 (A) @ VS=+5V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 250 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.120. Raw data for -Input Bias Current BIAS4 4 (A) @ VS=+5V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Input Bias Current BIAS4 4 (A) @ VS=+5V, VCM=0V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -3.08E-07 -3.20E-07 -3.16E-07 -3.12E-07 -3.01E-07 -2.92E-07 -3.14E-07 -2.90E-07 -2.94E-07 -3.17E-07 -3.12E-07 -3.13E-07 Total 20 -3.20E-07 -3.31E-07 -3.28E-07 -3.25E-07 -3.13E-07 -3.03E-07 -3.26E-07 -3.01E-07 -3.05E-07 -3.29E-07 -3.14E-07 -3.15E-07 Dose (krad(Si)) 50 100 -3.28E-07 -3.45E-07 -3.47E-07 -3.57E-07 -3.40E-07 -3.58E-07 -3.37E-07 -3.52E-07 -3.25E-07 -3.40E-07 -3.17E-07 -3.35E-07 -3.40E-07 -3.61E-07 -3.14E-07 -3.32E-07 -3.20E-07 -3.37E-07 -3.47E-07 -3.67E-07 -3.15E-07 -3.15E-07 -3.15E-07 -3.15E-07 200 -3.69E-07 -3.82E-07 -3.82E-07 -3.79E-07 -3.69E-07 -3.65E-07 -3.87E-07 -3.62E-07 -3.68E-07 -3.96E-07 -3.14E-07 -3.14E-07 -3.11E-07 -3.24E-07 -3.35E-07 -3.50E-07 -3.76E-07 7.31E-09 7.05E-09 9.08E-09 7.57E-09 6.73E-09 -2.91E-07 -3.04E-07 -3.10E-07 -3.30E-07 -3.58E-07 -3.31E-07 -3.43E-07 -3.60E-07 -3.71E-07 -3.95E-07 -3.02E-07 1.31E-08 -2.66E-07 -3.37E-07 -6.50E-07 PASS 6.50E-07 PASS -3.13E-07 1.33E-08 -2.76E-07 -3.49E-07 -7.50E-07 PASS 7.50E-07 PASS -3.28E-07 1.48E-08 -2.87E-07 -3.68E-07 -8.00E-07 PASS 8.00E-07 PASS An ISO 9001:2008 and DSCC Certified Company 251 -3.46E-07 1.62E-08 -3.02E-07 -3.91E-07 -8.50E-07 PASS 8.50E-07 PASS -3.75E-07 1.51E-08 -3.34E-07 -4.17E-07 -9.50E-07 PASS 9.50E-07 PASS Input Offset Voltage5 1 (V) @ VS=+5V, VCM=5V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.121. Plot of Input Offset Voltage5 1 (V) @ VS=+5V, VCM=5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 252 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.121. Raw data for Input Offset Voltage5 1 (V) @ VS=+5V, VCM=5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage5 1 (V) @ VS=+5V, VCM=5V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 2.56E-04 5.22E-04 1.81E-04 1.69E-04 3.50E-04 1.89E-04 2.05E-04 8.43E-05 8.98E-06 2.41E-04 1.00E-04 2.12E-04 Total 20 2.34E-04 4.90E-04 1.52E-04 1.52E-04 3.28E-04 1.70E-04 1.89E-04 8.09E-05 1.24E-05 2.26E-04 9.80E-05 2.11E-04 Dose (krad(Si)) 50 100 200 2.43E-04 2.35E-04 2.39E-04 4.90E-04 4.84E-04 4.85E-04 1.50E-04 1.44E-04 1.40E-04 1.61E-04 1.64E-04 1.70E-04 3.26E-04 3.35E-04 3.45E-04 1.66E-04 1.57E-04 1.37E-04 1.83E-04 1.75E-04 1.56E-04 7.62E-05 6.79E-05 5.76E-05 8.75E-06 2.95E-06 -1.30E-05 2.21E-04 2.16E-04 2.06E-04 9.75E-05 9.83E-05 9.77E-05 2.11E-04 2.11E-04 2.12E-04 2.95E-04 2.71E-04 2.74E-04 2.72E-04 2.76E-04 1.46E-04 1.42E-04 1.40E-04 1.40E-04 1.41E-04 6.95E-04 6.61E-04 6.58E-04 6.56E-04 6.62E-04 -1.04E-04 -1.19E-04 -1.10E-04 -1.11E-04 -1.10E-04 1.46E-04 9.61E-05 4.09E-04 -1.18E-04 -8.00E-04 PASS 8.00E-04 PASS 1.36E-04 8.72E-05 3.75E-04 -1.03E-04 -9.50E-04 PASS 9.50E-04 PASS 1.31E-04 8.66E-05 3.68E-04 -1.06E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 253 1.24E-04 8.65E-05 3.61E-04 -1.13E-04 -9.50E-04 PASS 9.50E-04 PASS 1.09E-04 8.64E-05 3.46E-04 -1.28E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Voltage5 2 (V) @ VS=+5V, VCM=5V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.122. Plot of Input Offset Voltage5 2 (V) @ VS=+5V, VCM=5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 254 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.122. Raw data for Input Offset Voltage5 2 (V) @ VS=+5V, VCM=5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage5 2 (V) @ VS=+5V, VCM=5V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total Dose (krad(Si)) 0 20 50 100 200 7.71E-05 4.86E-05 5.60E-05 5.47E-05 5.54E-05 2.32E-04 2.30E-04 2.35E-04 2.36E-04 2.45E-04 -1.56E-04 -2.04E-04 -1.99E-04 -1.92E-04 -1.85E-04 4.01E-05 2.19E-05 3.77E-05 4.59E-05 5.92E-05 2.55E-04 2.04E-04 2.01E-04 2.17E-04 2.31E-04 1.53E-04 1.34E-04 1.31E-04 1.29E-04 1.14E-04 -7.98E-05 -9.07E-05 -9.58E-05 -1.01E-04 -1.08E-04 1.39E-04 1.29E-04 1.33E-04 1.38E-04 1.27E-04 2.20E-04 2.09E-04 2.08E-04 2.03E-04 1.96E-04 1.61E-04 1.44E-04 1.41E-04 1.33E-04 1.22E-04 -2.20E-04 -2.22E-04 -2.23E-04 -2.22E-04 -2.22E-04 6.56E-05 6.66E-05 6.56E-05 6.68E-05 6.77E-05 8.97E-05 6.01E-05 6.63E-05 7.24E-05 8.09E-05 1.66E-04 1.74E-04 1.72E-04 1.72E-04 1.74E-04 5.46E-04 5.37E-04 5.37E-04 5.45E-04 5.58E-04 -3.66E-04 -4.17E-04 -4.05E-04 -4.00E-04 -3.96E-04 1.19E-04 1.15E-04 4.35E-04 -1.97E-04 -8.00E-04 PASS 8.00E-04 PASS 1.05E-04 1.14E-04 4.18E-04 -2.08E-04 -9.50E-04 PASS 9.50E-04 PASS 1.03E-04 1.16E-04 4.21E-04 -2.14E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 255 1.00E-04 1.17E-04 4.21E-04 -2.20E-04 -9.50E-04 PASS 9.50E-04 PASS 9.02E-05 1.16E-04 4.07E-04 -2.27E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Voltage5 3 (V) @ VS=+5V, VCM=5V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.123. Plot of Input Offset Voltage5 3 (V) @ VS=+5V, VCM=5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 256 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.123. Raw data for Input Offset Voltage5 3 (V) @ VS=+5V, VCM=5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage5 3 (V) @ VS=+5V, VCM=5V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total Dose (krad(Si)) 0 20 50 100 200 1.92E-04 2.41E-04 2.41E-04 2.35E-04 2.42E-04 5.29E-04 4.91E-04 4.89E-04 4.89E-04 4.93E-04 1.27E-04 1.01E-04 1.05E-04 1.04E-04 1.08E-04 1.69E-04 1.44E-04 1.50E-04 1.51E-04 1.53E-04 -4.78E-05 -7.32E-05 -8.99E-05 -9.01E-05 -9.30E-05 -2.50E-04 -2.66E-04 -2.69E-04 -2.74E-04 -2.95E-04 1.24E-04 1.02E-04 9.99E-05 9.18E-05 8.28E-05 1.66E-04 1.52E-04 1.50E-04 1.41E-04 1.24E-04 1.87E-04 2.14E-04 2.08E-04 1.97E-04 1.83E-04 9.24E-05 7.33E-05 6.67E-05 5.46E-05 4.38E-05 2.30E-04 2.29E-04 2.29E-04 2.29E-04 2.30E-04 2.56E-04 2.54E-04 2.55E-04 2.55E-04 2.56E-04 1.94E-04 1.81E-04 1.79E-04 1.78E-04 1.80E-04 2.09E-04 2.07E-04 2.12E-04 2.11E-04 2.13E-04 7.68E-04 7.50E-04 7.59E-04 7.56E-04 7.65E-04 -3.81E-04 -3.88E-04 -4.01E-04 -4.00E-04 -4.04E-04 6.38E-05 1.79E-04 5.56E-04 -4.28E-04 -8.00E-04 PASS 8.00E-04 PASS 5.50E-05 1.87E-04 5.68E-04 -4.58E-04 -9.50E-04 PASS 9.50E-04 PASS 5.11E-05 1.87E-04 5.63E-04 -4.61E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 257 4.21E-05 1.85E-04 5.48E-04 -4.64E-04 -9.50E-04 PASS 9.50E-04 PASS 2.77E-05 1.88E-04 5.42E-04 -4.87E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Voltage5 4 (V) @ VS=+5V, VCM=5V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.124. Plot of Input Offset Voltage5 4 (V) @ VS=+5V, VCM=5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 258 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.124. Raw data for Input Offset Voltage5 4 (V) @ VS=+5V, VCM=5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage5 4 (V) @ VS=+5V, VCM=5V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total 0 20 2.38E-04 2.16E-04 1.40E-04 1.05E-04 2.99E-04 2.63E-04 1.92E-04 1.84E-04 3.30E-04 3.09E-04 -4.11E-05 -3.69E-05 3.73E-04 3.70E-04 3.03E-04 3.07E-04 2.71E-04 2.73E-04 1.59E-04 1.44E-04 3.16E-04 3.13E-04 1.20E-04 1.22E-04 Dose (krad(Si)) 50 100 200 2.21E-04 2.18E-04 2.26E-04 1.09E-04 1.08E-04 1.17E-04 2.65E-04 2.63E-04 2.68E-04 1.94E-04 1.96E-04 2.06E-04 3.03E-04 3.16E-04 3.26E-04 -3.98E-05 -4.41E-05 -5.50E-05 3.64E-04 3.58E-04 3.46E-04 3.06E-04 2.97E-04 2.90E-04 2.71E-04 2.63E-04 2.54E-04 1.39E-04 1.34E-04 1.27E-04 3.13E-04 3.12E-04 3.15E-04 1.21E-04 1.22E-04 1.22E-04 2.40E-04 7.73E-05 4.52E-04 2.77E-05 2.15E-04 7.78E-05 4.29E-04 2.25E-06 2.18E-04 7.40E-05 4.21E-04 1.56E-05 2.20E-04 7.79E-05 4.34E-04 6.76E-06 2.29E-04 7.76E-05 4.42E-04 1.60E-05 2.13E-04 1.62E-04 6.57E-04 -2.31E-04 -8.00E-04 PASS 8.00E-04 PASS 2.11E-04 1.62E-04 6.54E-04 -2.31E-04 -9.50E-04 PASS 9.50E-04 PASS 2.08E-04 1.61E-04 6.51E-04 -2.35E-04 -9.50E-04 PASS 9.50E-04 PASS 2.02E-04 1.60E-04 6.41E-04 -2.37E-04 -9.50E-04 PASS 9.50E-04 PASS 1.92E-04 1.60E-04 6.31E-04 -2.46E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 259 Input Offset Current5 1 (A) @ VS=+5V, VCM=5V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 8.00E-08 6.00E-08 4.00E-08 2.00E-08 0.00E+00 -2.00E-08 -4.00E-08 -6.00E-08 -8.00E-08 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.125. Plot of Input Offset Current5 1 (A) @ VS=+5V, VCM=5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 260 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.125. Raw data for Input Offset Current5 1 (A) @ VS=+5V, VCM=5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current5 1 (A) @ VS=+5V, VCM=5V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 5.81E-09 2.87E-09 1.30E-09 6.44E-09 -7.60E-10 1.50E-10 -9.00E-10 5.79E-09 -5.41E-09 3.30E-09 1.80E-10 2.60E-10 Total 20 4.08E-09 1.35E-09 1.21E-09 4.87E-09 -5.80E-10 -8.00E-11 -3.20E-10 4.12E-09 -1.72E-09 3.45E-09 2.10E-10 9.00E-11 Dose (krad(Si)) 50 100 3.38E-09 2.25E-09 1.02E-09 -1.40E-09 1.37E-09 1.13E-09 4.59E-09 6.30E-09 -2.58E-09 -4.96E-09 -1.10E-10 -6.70E-10 -5.50E-10 -6.40E-10 5.44E-09 5.04E-09 -3.36E-09 -4.55E-09 1.59E-09 3.01E-09 1.70E-10 2.00E-10 1.30E-10 7.00E-11 200 2.76E-09 -1.08E-09 3.35E-09 6.29E-09 -3.13E-09 1.15E-09 -2.80E-10 5.14E-09 -5.43E-09 2.35E-09 1.20E-10 1.10E-10 3.13E-09 2.19E-09 1.56E-09 6.64E-10 1.64E-09 3.03E-09 2.24E-09 2.74E-09 4.19E-09 3.74E-09 1.14E-08 8.33E-09 9.06E-09 1.22E-08 1.19E-08 -5.17E-09 -3.96E-09 -5.95E-09 -1.08E-08 -8.62E-09 5.86E-10 4.27E-09 1.23E-08 -1.11E-08 -6.50E-08 PASS 6.50E-08 PASS 1.09E-09 2.55E-09 8.08E-09 -5.90E-09 -6.50E-08 PASS 6.50E-08 PASS 6.02E-10 3.24E-09 9.48E-09 -8.27E-09 -6.50E-08 PASS 6.50E-08 PASS An ISO 9001:2008 and DSCC Certified Company 261 4.38E-10 3.71E-09 1.06E-08 -9.74E-09 -6.50E-08 PASS 6.50E-08 PASS 5.86E-10 3.91E-09 1.13E-08 -1.01E-08 -6.50E-08 PASS 6.50E-08 PASS Input Offset Current5 2 (A) @ VS=+5V, VCM=5V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 8.00E-08 6.00E-08 4.00E-08 2.00E-08 0.00E+00 -2.00E-08 -4.00E-08 -6.00E-08 -8.00E-08 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.126. Plot of Input Offset Current5 2 (A) @ VS=+5V, VCM=5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 262 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.126. Raw data for Input Offset Current5 2 (A) @ VS=+5V, VCM=5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current5 2 (A) @ VS=+5V, VCM=5V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total Dose (krad(Si)) 0 20 50 100 200 9.80E-09 1.01E-08 8.95E-09 8.12E-09 9.33E-09 -1.04E-09 -1.11E-09 -1.82E-09 -3.88E-09 -3.06E-09 9.18E-09 1.11E-09 1.70E-09 4.79E-09 7.88E-09 4.17E-09 3.37E-09 5.05E-09 6.14E-09 5.41E-09 8.23E-09 -7.70E-10 -1.90E-09 5.20E-10 4.23E-09 3.68E-09 3.47E-09 3.79E-09 4.36E-09 3.57E-09 6.96E-09 6.60E-09 4.64E-09 6.10E-09 4.96E-09 1.04E-08 1.12E-08 1.15E-08 1.36E-08 1.14E-08 1.24E-08 1.18E-08 1.19E-08 1.19E-08 1.37E-08 1.70E-10 -3.10E-10 -4.10E-10 -1.67E-09 -1.30E-09 1.43E-09 1.64E-09 1.59E-09 1.60E-09 1.55E-09 8.78E-09 8.78E-09 9.10E-09 8.72E-09 8.99E-09 6.07E-09 2.54E-09 2.40E-09 3.14E-09 4.76E-09 4.54E-09 4.59E-09 4.66E-09 4.81E-09 4.81E-09 1.85E-08 1.51E-08 1.52E-08 1.63E-08 1.79E-08 -6.38E-09 -1.00E-08 -1.04E-08 -1.01E-08 -8.43E-09 6.72E-09 4.95E-09 2.03E-08 -6.85E-09 -6.50E-08 PASS 6.50E-08 PASS 6.55E-09 5.13E-09 2.06E-08 -7.53E-09 -6.50E-08 PASS 6.50E-08 PASS 6.27E-09 5.28E-09 2.08E-08 -8.22E-09 -6.50E-08 PASS 6.50E-08 PASS An ISO 9001:2008 and DSCC Certified Company 263 6.85E-09 6.12E-09 2.36E-08 -9.94E-09 -6.50E-08 PASS 6.50E-08 PASS 6.46E-09 6.07E-09 2.31E-08 -1.02E-08 -6.50E-08 PASS 6.50E-08 PASS Input Offset Current5 3 (A) @ VS=+5V, VCM=5V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 8.00E-08 6.00E-08 4.00E-08 2.00E-08 0.00E+00 -2.00E-08 -4.00E-08 -6.00E-08 -8.00E-08 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.127. Plot of Input Offset Current5 3 (A) @ VS=+5V, VCM=5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 264 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.127. Raw data for Input Offset Current5 3 (A) @ VS=+5V, VCM=5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current5 3 (A) @ VS=+5V, VCM=5V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -7.20E-10 1.64E-09 1.26E-08 -1.42E-09 -5.10E-10 -6.36E-09 -5.31E-09 1.43E-08 -2.51E-09 4.60E-09 -2.82E-09 -2.07E-09 Total 20 6.30E-09 1.56E-09 1.27E-08 -2.99E-09 -2.73E-09 -7.53E-09 -7.03E-09 1.46E-08 -2.80E-09 -1.90E-10 -1.57E-09 -2.39E-09 Dose (krad(Si)) 50 100 6.27E-09 3.13E-09 1.70E-09 8.80E-10 1.21E-08 1.11E-08 -1.17E-09 2.35E-09 -4.31E-09 -4.61E-09 -7.75E-09 -7.98E-09 -6.73E-09 -5.49E-09 1.55E-08 1.64E-08 -3.49E-09 -3.07E-09 -2.10E-10 -2.30E-10 -1.48E-09 -1.52E-09 -2.45E-09 -2.38E-09 200 5.02E-09 1.44E-09 1.40E-08 3.68E-09 -4.33E-09 -9.28E-09 -5.02E-09 1.79E-08 -1.79E-09 9.60E-10 -1.48E-09 -2.27E-09 2.31E-09 2.98E-09 2.92E-09 2.57E-09 3.96E-09 5.85E-09 6.64E-09 6.44E-09 5.65E-09 6.66E-09 1.83E-08 2.12E-08 2.06E-08 1.81E-08 2.22E-08 -1.37E-08 -1.52E-08 -1.47E-08 -1.29E-08 -1.43E-08 9.42E-10 8.60E-09 2.45E-08 -2.26E-08 -6.50E-08 PASS 6.50E-08 PASS -5.94E-10 9.01E-09 2.41E-08 -2.53E-08 -6.50E-08 PASS 6.50E-08 PASS -5.32E-10 9.45E-09 2.54E-08 -2.64E-08 -6.50E-08 PASS 6.50E-08 PASS An ISO 9001:2008 and DSCC Certified Company 265 -7.00E-11 9.66E-09 2.64E-08 -2.65E-08 -6.50E-08 PASS 6.50E-08 PASS 5.52E-10 1.04E-08 2.91E-08 -2.80E-08 -6.50E-08 PASS 6.50E-08 PASS Input Offset Current5 4 (A) @ VS=+5V, VCM=5V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 8.00E-08 6.00E-08 4.00E-08 2.00E-08 0.00E+00 -2.00E-08 -4.00E-08 -6.00E-08 -8.00E-08 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.128. Plot of Input Offset Current5 4 (A) @ VS=+5V, VCM=5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 266 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.128. Raw data for Input Offset Current5 4 (A) @ VS=+5V, VCM=5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current5 4 (A) @ VS=+5V, VCM=5V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 7.27E-09 -5.44E-09 -1.36E-08 1.18E-08 2.89E-09 1.23E-09 -5.30E-10 -9.65E-09 8.16E-09 -5.60E-10 8.00E-11 4.35E-09 Total 20 6.92E-09 -5.86E-09 -1.23E-08 1.17E-08 2.89E-09 7.40E-10 -1.22E-09 -8.02E-09 9.12E-09 -3.00E-10 -1.00E-10 4.43E-09 Dose (krad(Si)) 50 100 4.70E-09 1.65E-09 -6.81E-09 -7.33E-09 -1.45E-08 -1.58E-08 1.09E-08 1.08E-08 -1.90E-10 -1.80E-09 3.20E-10 -1.07E-09 -2.34E-09 -2.56E-09 -8.83E-09 -7.87E-09 9.98E-09 9.64E-09 -1.14E-09 1.70E-10 -1.00E-10 -1.00E-10 4.53E-09 4.41E-09 200 3.26E-09 -5.36E-09 -1.50E-08 1.14E-08 -1.43E-09 1.10E-10 -3.53E-09 -7.51E-09 9.55E-09 -1.27E-09 -1.20E-10 4.46E-09 5.84E-10 6.74E-10 -1.18E-09 -2.49E-09 -1.44E-09 1.02E-08 9.70E-09 9.90E-09 9.96E-09 9.82E-09 2.84E-08 2.73E-08 2.60E-08 2.48E-08 2.55E-08 -2.73E-08 -2.59E-08 -2.83E-08 -2.98E-08 -2.84E-08 -2.70E-10 6.35E-09 1.72E-08 -1.77E-08 -6.50E-08 PASS 6.50E-08 PASS 6.40E-11 6.12E-09 1.68E-08 -1.67E-08 -6.50E-08 PASS 6.50E-08 PASS -4.02E-10 6.78E-09 1.82E-08 -1.90E-08 -6.50E-08 PASS 6.50E-08 PASS An ISO 9001:2008 and DSCC Certified Company 267 -3.38E-10 6.36E-09 1.71E-08 -1.78E-08 -6.50E-08 PASS 6.50E-08 PASS -5.30E-10 6.33E-09 1.68E-08 -1.79E-08 -6.50E-08 PASS 6.50E-08 PASS +Input Bias Current BIAS5 1 (A) @ VS=+5V, VCM=5V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-06 1.00E-06 5.00E-07 0.00E+00 -5.00E-07 -1.00E-06 -1.50E-06 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.129. Plot of +Input Bias Current BIAS5 1 (A) @ VS=+5V, VCM=5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 268 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.129. Raw data for +Input Bias Current BIAS5 1 (A) @ VS=+5V, VCM=5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) +Input Bias Current BIAS5 1 (A) @ VS=+5V, VCM=5V Device 0 20 50 100 200 519 3.02E-07 3.38E-07 3.79E-07 4.30E-07 5.03E-07 520 3.24E-07 3.58E-07 4.05E-07 4.57E-07 5.31E-07 521 3.07E-07 3.48E-07 3.98E-07 4.51E-07 5.22E-07 522 3.06E-07 3.40E-07 3.86E-07 4.34E-07 5.14E-07 524 3.03E-07 3.38E-07 3.75E-07 4.30E-07 5.05E-07 536 2.98E-07 3.35E-07 3.80E-07 4.37E-07 5.18E-07 537 3.08E-07 3.39E-07 3.88E-07 4.43E-07 5.19E-07 538 2.87E-07 3.30E-07 3.74E-07 4.32E-07 5.02E-07 539 2.91E-07 3.31E-07 3.74E-07 4.30E-07 5.00E-07 542 3.06E-07 3.40E-07 3.92E-07 4.53E-07 5.29E-07 543 3.01E-07 3.02E-07 3.03E-07 3.03E-07 3.02E-07 544 2.99E-07 3.00E-07 3.00E-07 3.00E-07 2.99E-07 Biased Statistics Average Biased 3.08E-07 3.45E-07 3.89E-07 4.40E-07 5.15E-07 Std Dev Biased 8.94E-09 8.87E-09 1.24E-08 1.28E-08 1.18E-08 Ps90%/90% (+KTL) Biased 3.33E-07 3.69E-07 4.23E-07 4.75E-07 5.47E-07 Ps90%/90% (-KTL) Biased 2.84E-07 3.20E-07 3.55E-07 4.05E-07 4.83E-07 Un-Biased Statistics Average Un-Biased 2.98E-07 3.35E-07 3.82E-07 4.39E-07 5.13E-07 Std Dev Un-Biased 9.06E-09 4.38E-09 8.03E-09 9.20E-09 1.23E-08 Ps90%/90% (+KTL) Un-Biased 3.23E-07 3.47E-07 4.04E-07 4.64E-07 5.47E-07 Ps90%/90% (-KTL) Un-Biased 2.73E-07 3.23E-07 3.60E-07 4.14E-07 4.80E-07 Specification MIN -6.50E-07 -7.50E-07 -8.00E-07 -8.50E-07 -9.50E-07 Status PASS PASS PASS PASS PASS Specification MAX 6.50E-07 7.50E-07 8.00E-07 8.50E-07 9.50E-07 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 269 +Input Bias Current BIAS5 2 (A) @ VS=+5V, VCM=5V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-06 1.00E-06 5.00E-07 0.00E+00 -5.00E-07 -1.00E-06 -1.50E-06 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.130. Plot of +Input Bias Current BIAS5 2 (A) @ VS=+5V, VCM=5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 270 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.130. Raw data for +Input Bias Current BIAS5 2 (A) @ VS=+5V, VCM=5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) +Input Bias Current BIAS5 2 (A) @ VS=+5V, VCM=5V Device 0 20 50 100 200 519 3.17E-07 3.54E-07 3.96E-07 4.49E-07 5.21E-07 520 2.98E-07 3.35E-07 3.77E-07 4.25E-07 5.01E-07 521 3.21E-07 3.51E-07 3.99E-07 4.52E-07 5.21E-07 522 3.13E-07 3.45E-07 3.93E-07 4.40E-07 5.18E-07 524 2.95E-07 3.27E-07 3.61E-07 4.11E-07 4.80E-07 536 3.08E-07 3.41E-07 3.95E-07 4.51E-07 5.31E-07 537 3.10E-07 3.42E-07 3.92E-07 4.47E-07 5.23E-07 538 3.03E-07 3.41E-07 3.81E-07 4.36E-07 5.01E-07 539 3.30E-07 3.65E-07 4.18E-07 4.74E-07 5.47E-07 542 3.07E-07 3.39E-07 3.92E-07 4.51E-07 5.26E-07 543 2.99E-07 3.01E-07 3.01E-07 3.01E-07 3.00E-07 544 3.17E-07 3.17E-07 3.18E-07 3.17E-07 3.17E-07 Biased Statistics Average Biased 3.09E-07 3.43E-07 3.85E-07 4.35E-07 5.08E-07 Std Dev Biased 1.17E-08 1.14E-08 1.59E-08 1.72E-08 1.81E-08 Ps90%/90% (+KTL) Biased 3.41E-07 3.74E-07 4.29E-07 4.82E-07 5.58E-07 Ps90%/90% (-KTL) Biased 2.77E-07 3.11E-07 3.42E-07 3.88E-07 4.59E-07 Un-Biased Statistics Average Un-Biased 3.11E-07 3.45E-07 3.96E-07 4.52E-07 5.26E-07 Std Dev Un-Biased 1.05E-08 1.10E-08 1.37E-08 1.39E-08 1.65E-08 Ps90%/90% (+KTL) Un-Biased 3.40E-07 3.75E-07 4.33E-07 4.90E-07 5.71E-07 Ps90%/90% (-KTL) Un-Biased 2.83E-07 3.15E-07 3.58E-07 4.14E-07 4.81E-07 Specification MIN -6.50E-07 -7.50E-07 -8.00E-07 -8.50E-07 -9.50E-07 Status PASS PASS PASS PASS PASS Specification MAX 6.50E-07 7.50E-07 8.00E-07 8.50E-07 9.50E-07 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 271 +Input Bias Current BIAS5 3 (A) @ VS=+5V, VCM=5V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-06 1.00E-06 5.00E-07 0.00E+00 -5.00E-07 -1.00E-06 -1.50E-06 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.131. Plot of +Input Bias Current BIAS5 3 (A) @ VS=+5V, VCM=5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 272 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.131. Raw data for +Input Bias Current BIAS5 3 (A) @ VS=+5V, VCM=5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) +Input Bias Current BIAS5 3 (A) @ VS=+5V, VCM=5V Device 0 20 50 100 200 519 3.03E-07 3.45E-07 3.87E-07 4.38E-07 5.10E-07 520 2.95E-07 3.30E-07 3.71E-07 4.21E-07 4.93E-07 521 3.25E-07 3.57E-07 4.05E-07 4.60E-07 5.33E-07 522 3.05E-07 3.43E-07 3.91E-07 4.38E-07 5.20E-07 524 2.87E-07 3.24E-07 3.59E-07 4.10E-07 4.80E-07 536 2.98E-07 3.36E-07 3.80E-07 4.38E-07 5.17E-07 537 3.02E-07 3.39E-07 3.87E-07 4.45E-07 5.22E-07 538 3.13E-07 3.48E-07 3.97E-07 4.53E-07 5.24E-07 539 3.22E-07 3.54E-07 4.05E-07 4.62E-07 5.36E-07 542 3.02E-07 3.36E-07 3.89E-07 4.49E-07 5.24E-07 543 2.96E-07 2.98E-07 2.98E-07 2.98E-07 2.98E-07 544 3.02E-07 3.03E-07 3.03E-07 3.03E-07 3.02E-07 Biased Statistics Average Biased 3.03E-07 3.40E-07 3.83E-07 4.33E-07 5.07E-07 Std Dev Biased 1.44E-08 1.31E-08 1.78E-08 1.90E-08 2.08E-08 Ps90%/90% (+KTL) Biased 3.43E-07 3.76E-07 4.31E-07 4.86E-07 5.64E-07 Ps90%/90% (-KTL) Biased 2.64E-07 3.04E-07 3.34E-07 3.81E-07 4.50E-07 Un-Biased Statistics Average Un-Biased 3.07E-07 3.43E-07 3.92E-07 4.49E-07 5.25E-07 Std Dev Un-Biased 1.02E-08 7.98E-09 9.41E-09 8.84E-09 7.05E-09 Ps90%/90% (+KTL) Un-Biased 3.35E-07 3.65E-07 4.17E-07 4.74E-07 5.44E-07 Ps90%/90% (-KTL) Un-Biased 2.79E-07 3.21E-07 3.66E-07 4.25E-07 5.05E-07 Specification MIN -6.50E-07 -7.50E-07 -8.00E-07 -8.50E-07 -9.50E-07 Status PASS PASS PASS PASS PASS Specification MAX 6.50E-07 7.50E-07 8.00E-07 8.50E-07 9.50E-07 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 273 +Input Bias Current BIAS5 4 (A) @ VS=+5V, VCM=5V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-06 1.00E-06 5.00E-07 0.00E+00 -5.00E-07 -1.00E-06 -1.50E-06 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.132. Plot of +Input Bias Current BIAS5 4 (A) @ VS=+5V, VCM=5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 274 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.132. Raw data for +Input Bias Current BIAS5 4 (A) @ VS=+5V, VCM=5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) +Input Bias Current BIAS5 4 (A) @ VS=+5V, VCM=5V Device 0 20 50 100 200 519 3.04E-07 3.38E-07 3.78E-07 4.25E-07 4.99E-07 520 3.11E-07 3.44E-07 3.90E-07 4.42E-07 5.19E-07 521 3.08E-07 3.39E-07 3.86E-07 4.37E-07 5.06E-07 522 3.16E-07 3.49E-07 3.95E-07 4.40E-07 5.16E-07 524 3.09E-07 3.36E-07 3.78E-07 4.30E-07 5.03E-07 536 2.92E-07 3.34E-07 3.76E-07 4.32E-07 5.11E-07 537 3.05E-07 3.41E-07 3.88E-07 4.41E-07 5.15E-07 538 2.96E-07 3.36E-07 3.79E-07 4.36E-07 5.07E-07 539 2.98E-07 3.35E-07 3.77E-07 4.31E-07 5.01E-07 542 3.05E-07 3.41E-07 3.91E-07 4.50E-07 5.26E-07 543 3.05E-07 3.07E-07 3.07E-07 3.07E-07 3.06E-07 544 3.09E-07 3.10E-07 3.10E-07 3.10E-07 3.10E-07 Biased Statistics Average Biased 3.10E-07 3.41E-07 3.85E-07 4.35E-07 5.09E-07 Std Dev Biased 4.42E-09 5.06E-09 7.37E-09 7.13E-09 8.51E-09 Ps90%/90% (+KTL) Biased 3.22E-07 3.55E-07 4.06E-07 4.54E-07 5.32E-07 Ps90%/90% (-KTL) Biased 2.98E-07 3.27E-07 3.65E-07 4.15E-07 4.85E-07 Un-Biased Statistics Average Un-Biased 2.99E-07 3.37E-07 3.82E-07 4.38E-07 5.12E-07 Std Dev Un-Biased 5.65E-09 3.49E-09 6.73E-09 7.68E-09 9.35E-09 Ps90%/90% (+KTL) Un-Biased 3.15E-07 3.47E-07 4.01E-07 4.59E-07 5.38E-07 Ps90%/90% (-KTL) Un-Biased 2.84E-07 3.28E-07 3.64E-07 4.17E-07 4.86E-07 Specification MIN -6.50E-07 -7.50E-07 -8.00E-07 -8.50E-07 -9.50E-07 Status PASS PASS PASS PASS PASS Specification MAX 6.50E-07 7.50E-07 8.00E-07 8.50E-07 9.50E-07 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 275 -Input Bias Current BIAS5 1 (A) @ VS=+5V, VCM=5V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-06 1.00E-06 5.00E-07 0.00E+00 -5.00E-07 -1.00E-06 -1.50E-06 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.133. Plot of -Input Bias Current BIAS5 1 (A) @ VS=+5V, VCM=5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 276 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.133. Raw data for -Input Bias Current BIAS5 1 (A) @ VS=+5V, VCM=5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) -Input Bias Current BIAS5 1 (A) @ VS=+5V, VCM=5V Device 0 20 50 100 200 519 2.98E-07 3.35E-07 3.75E-07 4.28E-07 4.99E-07 520 3.22E-07 3.58E-07 4.05E-07 4.59E-07 5.35E-07 521 3.07E-07 3.46E-07 3.98E-07 4.50E-07 5.19E-07 522 3.00E-07 3.36E-07 3.83E-07 4.29E-07 5.07E-07 524 3.05E-07 3.40E-07 3.80E-07 4.36E-07 5.12E-07 536 2.99E-07 3.37E-07 3.80E-07 4.38E-07 5.17E-07 537 3.10E-07 3.40E-07 3.89E-07 4.43E-07 5.20E-07 538 2.82E-07 3.27E-07 3.70E-07 4.26E-07 4.96E-07 539 2.98E-07 3.34E-07 3.78E-07 4.35E-07 5.06E-07 542 3.04E-07 3.37E-07 3.92E-07 4.52E-07 5.26E-07 543 3.02E-07 3.03E-07 3.04E-07 3.03E-07 3.03E-07 544 3.00E-07 3.01E-07 3.01E-07 3.01E-07 3.00E-07 Biased Statistics Average Biased 3.06E-07 3.43E-07 3.88E-07 4.40E-07 5.14E-07 Std Dev Biased 9.46E-09 9.68E-09 1.26E-08 1.36E-08 1.36E-08 Ps90%/90% (+KTL) Biased 3.32E-07 3.69E-07 4.23E-07 4.78E-07 5.52E-07 Ps90%/90% (-KTL) Biased 2.81E-07 3.16E-07 3.54E-07 4.03E-07 4.77E-07 Un-Biased Statistics Average Un-Biased 2.99E-07 3.35E-07 3.82E-07 4.39E-07 5.13E-07 Std Dev Un-Biased 1.03E-08 4.79E-09 8.91E-09 9.58E-09 1.20E-08 Ps90%/90% (+KTL) Un-Biased 3.27E-07 3.48E-07 4.06E-07 4.65E-07 5.46E-07 Ps90%/90% (-KTL) Un-Biased 2.71E-07 3.22E-07 3.57E-07 4.12E-07 4.80E-07 Specification MIN -6.50E-07 -7.50E-07 -8.00E-07 -8.50E-07 -9.50E-07 Status PASS PASS PASS PASS PASS Specification MAX 6.50E-07 7.50E-07 8.00E-07 8.50E-07 9.50E-07 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 277 -Input Bias Current BIAS5 2 (A) @ VS=+5V, VCM=5V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-06 1.00E-06 5.00E-07 0.00E+00 -5.00E-07 -1.00E-06 -1.50E-06 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.134. Plot of -Input Bias Current BIAS5 2 (A) @ VS=+5V, VCM=5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 278 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.134. Raw data for -Input Bias Current BIAS5 2 (A) @ VS=+5V, VCM=5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) -Input Bias Current BIAS5 2 (A) @ VS=+5V, VCM=5V Device 0 20 50 100 200 519 3.08E-07 3.42E-07 3.87E-07 4.41E-07 5.13E-07 520 3.00E-07 3.37E-07 3.78E-07 4.31E-07 5.03E-07 521 3.13E-07 3.51E-07 3.97E-07 4.47E-07 5.14E-07 522 3.10E-07 3.42E-07 3.87E-07 4.33E-07 5.14E-07 524 2.88E-07 3.28E-07 3.64E-07 4.11E-07 4.78E-07 536 3.05E-07 3.40E-07 3.89E-07 4.47E-07 5.27E-07 537 3.04E-07 3.37E-07 3.87E-07 4.43E-07 5.19E-07 538 2.93E-07 3.31E-07 3.71E-07 4.23E-07 4.91E-07 539 3.18E-07 3.55E-07 4.05E-07 4.63E-07 5.34E-07 542 3.08E-07 3.40E-07 3.95E-07 4.53E-07 5.28E-07 543 2.99E-07 3.00E-07 3.00E-07 3.00E-07 3.00E-07 544 3.09E-07 3.10E-07 3.10E-07 3.10E-07 3.09E-07 Biased Statistics Average Biased 3.04E-07 3.40E-07 3.83E-07 4.32E-07 5.04E-07 Std Dev Biased 1.02E-08 8.31E-09 1.25E-08 1.34E-08 1.55E-08 Ps90%/90% (+KTL) Biased 3.32E-07 3.63E-07 4.17E-07 4.69E-07 5.47E-07 Ps90%/90% (-KTL) Biased 2.76E-07 3.17E-07 3.49E-07 3.96E-07 4.62E-07 Un-Biased Statistics Average Un-Biased 3.06E-07 3.41E-07 3.89E-07 4.46E-07 5.20E-07 Std Dev Un-Biased 8.93E-09 8.88E-09 1.24E-08 1.51E-08 1.71E-08 Ps90%/90% (+KTL) Un-Biased 3.30E-07 3.65E-07 4.23E-07 4.87E-07 5.67E-07 Ps90%/90% (-KTL) Un-Biased 2.81E-07 3.16E-07 3.55E-07 4.04E-07 4.73E-07 Specification MIN -6.50E-07 -7.50E-07 -8.00E-07 -8.50E-07 -9.50E-07 Status PASS PASS PASS PASS PASS Specification MAX 6.50E-07 7.50E-07 8.00E-07 8.50E-07 9.50E-07 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 279 -Input Bias Current BIAS5 3 (A) @ VS=+5V, VCM=5V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-06 1.00E-06 5.00E-07 0.00E+00 -5.00E-07 -1.00E-06 -1.50E-06 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.135. Plot of -Input Bias Current BIAS5 3 (A) @ VS=+5V, VCM=5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 280 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.135. Raw data for -Input Bias Current BIAS5 3 (A) @ VS=+5V, VCM=5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) -Input Bias Current BIAS5 3 (A) @ VS=+5V, VCM=5V Device 0 20 50 100 200 519 3.05E-07 3.41E-07 3.81E-07 4.34E-07 5.05E-07 520 2.95E-07 3.30E-07 3.69E-07 4.21E-07 4.92E-07 521 3.14E-07 3.46E-07 3.94E-07 4.49E-07 5.21E-07 522 3.07E-07 3.46E-07 3.92E-07 4.36E-07 5.17E-07 524 2.88E-07 3.28E-07 3.63E-07 4.16E-07 4.86E-07 536 3.05E-07 3.39E-07 3.89E-07 4.46E-07 5.25E-07 537 3.08E-07 3.46E-07 3.97E-07 4.52E-07 5.27E-07 538 3.00E-07 3.40E-07 3.82E-07 4.38E-07 5.07E-07 539 3.26E-07 3.59E-07 4.10E-07 4.67E-07 5.40E-07 542 2.98E-07 3.37E-07 3.91E-07 4.50E-07 5.24E-07 543 3.00E-07 3.01E-07 3.01E-07 3.00E-07 3.00E-07 544 3.05E-07 3.06E-07 3.06E-07 3.06E-07 3.06E-07 Biased Statistics Average Biased 3.02E-07 3.38E-07 3.80E-07 4.31E-07 5.04E-07 Std Dev Biased 1.04E-08 8.53E-09 1.37E-08 1.30E-08 1.51E-08 Ps90%/90% (+KTL) Biased 3.30E-07 3.61E-07 4.17E-07 4.67E-07 5.46E-07 Ps90%/90% (-KTL) Biased 2.73E-07 3.15E-07 3.42E-07 3.96E-07 4.63E-07 Un-Biased Statistics Average Un-Biased 3.07E-07 3.44E-07 3.94E-07 4.50E-07 5.25E-07 Std Dev Un-Biased 1.11E-08 8.88E-09 1.06E-08 1.05E-08 1.17E-08 Ps90%/90% (+KTL) Un-Biased 3.38E-07 3.68E-07 4.23E-07 4.79E-07 5.57E-07 Ps90%/90% (-KTL) Un-Biased 2.77E-07 3.20E-07 3.65E-07 4.22E-07 4.92E-07 Specification MIN -6.50E-07 -7.50E-07 -8.00E-07 -8.50E-07 -9.50E-07 Status PASS PASS PASS PASS PASS Specification MAX 6.50E-07 7.50E-07 8.00E-07 8.50E-07 9.50E-07 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 281 -Input Bias Current BIAS5 4 (A) @ VS=+5V, VCM=5V TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-06 1.00E-06 5.00E-07 0.00E+00 -5.00E-07 -1.00E-06 -1.50E-06 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.136. Plot of -Input Bias Current BIAS5 4 (A) @ VS=+5V, VCM=5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 282 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.136. Raw data for -Input Bias Current BIAS5 4 (A) @ VS=+5V, VCM=5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) -Input Bias Current BIAS5 4 (A) @ VS=+5V, VCM=5V Device 0 20 50 100 200 519 2.98E-07 3.33E-07 3.73E-07 4.27E-07 4.96E-07 520 3.18E-07 3.50E-07 3.98E-07 4.51E-07 5.25E-07 521 3.23E-07 3.53E-07 4.01E-07 4.54E-07 5.24E-07 522 3.05E-07 3.38E-07 3.83E-07 4.30E-07 5.07E-07 524 3.07E-07 3.41E-07 3.79E-07 4.34E-07 5.06E-07 536 2.92E-07 3.34E-07 3.77E-07 4.34E-07 5.11E-07 537 3.07E-07 3.43E-07 3.92E-07 4.45E-07 5.19E-07 538 3.07E-07 3.39E-07 3.88E-07 4.44E-07 5.15E-07 539 2.91E-07 3.27E-07 3.69E-07 4.23E-07 4.93E-07 542 3.07E-07 3.39E-07 3.93E-07 4.50E-07 5.26E-07 543 3.07E-07 3.08E-07 3.08E-07 3.08E-07 3.08E-07 544 3.06E-07 3.07E-07 3.07E-07 3.07E-07 3.06E-07 Biased Statistics Average Biased 3.10E-07 3.43E-07 3.87E-07 4.39E-07 5.12E-07 Std Dev Biased 1.00E-08 8.42E-09 1.21E-08 1.25E-08 1.26E-08 Ps90%/90% (+KTL) Biased 3.38E-07 3.66E-07 4.20E-07 4.73E-07 5.46E-07 Ps90%/90% (-KTL) Biased 2.83E-07 3.20E-07 3.54E-07 4.05E-07 4.77E-07 Un-Biased Statistics Average Un-Biased 3.01E-07 3.36E-07 3.84E-07 4.39E-07 5.13E-07 Std Dev Un-Biased 8.31E-09 6.44E-09 1.04E-08 1.07E-08 1.25E-08 Ps90%/90% (+KTL) Un-Biased 3.23E-07 3.54E-07 4.12E-07 4.69E-07 5.47E-07 Ps90%/90% (-KTL) Un-Biased 2.78E-07 3.19E-07 3.55E-07 4.10E-07 4.78E-07 Specification MIN -6.50E-07 -7.50E-07 -8.00E-07 -8.50E-07 -9.50E-07 Status PASS PASS PASS PASS PASS Specification MAX 6.50E-07 7.50E-07 8.00E-07 8.50E-07 9.50E-07 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 283 Output Voltage Swing High4 1 (V) @ VS=+5V IL=0mA TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 2.50E-02 2.00E-02 1.50E-02 1.00E-02 5.00E-03 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.137. Plot of Output Voltage Swing High4 1 (V) @ VS=+5V IL=0mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 284 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.137. Raw data for Output Voltage Swing High4 1 (V) @ VS=+5V IL=0mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Swing High4 1 (V) @ VS=+5V IL=0mA Device 0 20 50 100 200 519 4.43E-03 4.54E-03 4.85E-03 4.78E-03 5.03E-03 520 4.61E-03 4.59E-03 4.60E-03 4.76E-03 5.05E-03 521 4.49E-03 4.57E-03 4.73E-03 4.88E-03 4.97E-03 522 4.73E-03 4.74E-03 4.73E-03 4.91E-03 5.13E-03 524 4.56E-03 4.54E-03 4.72E-03 4.76E-03 4.97E-03 536 4.64E-03 4.62E-03 4.82E-03 4.96E-03 5.25E-03 537 4.64E-03 4.65E-03 4.87E-03 4.96E-03 5.29E-03 538 4.34E-03 4.47E-03 4.60E-03 4.83E-03 5.10E-03 539 4.49E-03 4.59E-03 4.73E-03 4.88E-03 5.17E-03 542 4.64E-03 4.65E-03 4.97E-03 5.03E-03 5.30E-03 543 4.46E-03 4.52E-03 4.43E-03 4.51E-03 4.58E-03 544 4.38E-03 4.47E-03 4.60E-03 4.49E-03 4.63E-03 Biased Statistics Average Biased 4.56E-03 4.60E-03 4.73E-03 4.82E-03 5.03E-03 Std Dev Biased 1.15E-04 8.32E-05 8.85E-05 7.16E-05 6.63E-05 Ps90%/90% (+KTL) Biased 4.88E-03 4.82E-03 4.97E-03 5.01E-03 5.21E-03 Ps90%/90% (-KTL) Biased 4.25E-03 4.37E-03 4.48E-03 4.62E-03 4.85E-03 Un-Biased Statistics Average Un-Biased 4.55E-03 4.60E-03 4.80E-03 4.93E-03 5.22E-03 Std Dev Un-Biased 1.34E-04 7.47E-05 1.41E-04 7.79E-05 8.53E-05 Ps90%/90% (+KTL) Un-Biased 4.92E-03 4.80E-03 5.18E-03 5.15E-03 5.46E-03 Ps90%/90% (-KTL) Un-Biased 4.18E-03 4.39E-03 4.41E-03 4.72E-03 4.99E-03 Specification MAX 1.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 285 Output Voltage Swing High4 2 (V) @ VS=+5V IL=0mA TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 2.50E-02 2.00E-02 1.50E-02 1.00E-02 5.00E-03 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.138. Plot of Output Voltage Swing High4 2 (V) @ VS=+5V IL=0mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 286 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.138. Raw data for Output Voltage Swing High4 2 (V) @ VS=+5V IL=0mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Swing High4 2 (V) @ VS=+5V IL=0mA Device 0 20 50 100 200 519 4.85E-03 4.65E-03 4.97E-03 4.98E-03 5.18E-03 520 4.63E-03 4.69E-03 4.63E-03 4.93E-03 4.95E-03 521 4.64E-03 4.67E-03 4.82E-03 4.83E-03 5.05E-03 522 4.54E-03 4.52E-03 4.70E-03 4.69E-03 4.93E-03 524 4.61E-03 4.42E-03 4.68E-03 4.80E-03 4.90E-03 536 4.71E-03 4.86E-03 4.89E-03 5.05E-03 5.37E-03 537 4.75E-03 4.70E-03 4.97E-03 5.17E-03 5.22E-03 538 4.49E-03 4.57E-03 4.92E-03 4.90E-03 5.08E-03 539 4.64E-03 4.67E-03 5.05E-03 5.15E-03 5.37E-03 542 4.63E-03 4.52E-03 4.89E-03 5.01E-03 5.30E-03 543 4.51E-03 4.37E-03 4.52E-03 4.46E-03 4.49E-03 544 4.48E-03 4.64E-03 4.72E-03 4.80E-03 4.63E-03 Biased Statistics Average Biased 4.65E-03 4.59E-03 4.76E-03 4.85E-03 5.00E-03 Std Dev Biased 1.16E-04 1.16E-04 1.37E-04 1.14E-04 1.14E-04 Ps90%/90% (+KTL) Biased 4.97E-03 4.91E-03 5.13E-03 5.16E-03 5.32E-03 Ps90%/90% (-KTL) Biased 4.34E-03 4.27E-03 4.39E-03 4.53E-03 4.69E-03 Un-Biased Statistics Average Un-Biased 4.64E-03 4.66E-03 4.94E-03 5.06E-03 5.27E-03 Std Dev Un-Biased 9.94E-05 1.32E-04 6.77E-05 1.10E-04 1.22E-04 Ps90%/90% (+KTL) Un-Biased 4.92E-03 5.02E-03 5.13E-03 5.36E-03 5.60E-03 Ps90%/90% (-KTL) Un-Biased 4.37E-03 4.30E-03 4.76E-03 4.75E-03 4.93E-03 Specification MAX 1.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 287 Output Voltage Swing High4 3 (V) @ VS=+5V IL=0mA TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 2.50E-02 2.00E-02 1.50E-02 1.00E-02 5.00E-03 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.139. Plot of Output Voltage Swing High4 3 (V) @ VS=+5V IL=0mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 288 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.139. Raw data for Output Voltage Swing High4 3 (V) @ VS=+5V IL=0mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Swing High4 3 (V) @ VS=+5V IL=0mA Device 0 20 50 100 200 519 4.83E-03 4.89E-03 5.02E-03 5.03E-03 5.22E-03 520 4.59E-03 4.82E-03 4.73E-03 4.98E-03 5.07E-03 521 4.64E-03 4.64E-03 4.77E-03 5.01E-03 5.03E-03 522 4.46E-03 4.50E-03 4.72E-03 4.85E-03 4.85E-03 524 4.56E-03 4.54E-03 4.68E-03 4.83E-03 4.97E-03 536 4.58E-03 4.82E-03 4.90E-03 5.10E-03 5.45E-03 537 4.80E-03 4.82E-03 4.94E-03 5.10E-03 5.27E-03 538 4.41E-03 4.59E-03 4.78E-03 4.96E-03 5.13E-03 539 4.85E-03 4.86E-03 4.99E-03 5.20E-03 5.45E-03 542 4.63E-03 4.76E-03 5.02E-03 4.88E-03 5.27E-03 543 4.41E-03 4.38E-03 4.58E-03 4.49E-03 4.48E-03 544 4.49E-03 4.52E-03 4.68E-03 4.63E-03 4.70E-03 Biased Statistics Average Biased 4.62E-03 4.68E-03 4.78E-03 4.94E-03 5.03E-03 Std Dev Biased 1.36E-04 1.71E-04 1.36E-04 9.33E-05 1.36E-04 Ps90%/90% (+KTL) Biased 4.99E-03 5.15E-03 5.16E-03 5.20E-03 5.40E-03 Ps90%/90% (-KTL) Biased 4.24E-03 4.21E-03 4.41E-03 4.68E-03 4.66E-03 Un-Biased Statistics Average Un-Biased 4.65E-03 4.77E-03 4.93E-03 5.05E-03 5.31E-03 Std Dev Un-Biased 1.77E-04 1.07E-04 9.37E-05 1.27E-04 1.37E-04 Ps90%/90% (+KTL) Un-Biased 5.14E-03 5.06E-03 5.18E-03 5.40E-03 5.69E-03 Ps90%/90% (-KTL) Un-Biased 4.17E-03 4.48E-03 4.67E-03 4.70E-03 4.94E-03 Specification MAX 1.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 289 Output Voltage Swing High4 4 (V) @ VS=+5V IL=0mA TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 2.50E-02 2.00E-02 1.50E-02 1.00E-02 5.00E-03 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.140. Plot of Output Voltage Swing High4 4 (V) @ VS=+5V IL=0mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 290 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.140. Raw data for Output Voltage Swing High4 4 (V) @ VS=+5V IL=0mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Swing High4 4 (V) @ VS=+5V IL=0mA Device 0 20 50 100 200 519 4.70E-03 4.86E-03 4.85E-03 4.95E-03 5.02E-03 520 4.73E-03 4.72E-03 4.89E-03 5.10E-03 4.98E-03 521 4.70E-03 4.74E-03 4.75E-03 4.93E-03 5.02E-03 522 4.78E-03 4.74E-03 4.99E-03 4.98E-03 5.18E-03 524 4.66E-03 4.77E-03 4.80E-03 4.78E-03 5.05E-03 536 4.64E-03 4.77E-03 4.94E-03 4.98E-03 5.32E-03 537 4.58E-03 4.81E-03 4.94E-03 5.03E-03 5.40E-03 538 4.63E-03 4.70E-03 4.72E-03 4.95E-03 5.15E-03 539 4.61E-03 4.65E-03 4.84E-03 4.98E-03 5.20E-03 542 4.68E-03 4.76E-03 4.87E-03 5.15E-03 5.30E-03 543 4.51E-03 4.57E-03 4.57E-03 4.56E-03 4.68E-03 544 4.56E-03 4.67E-03 4.63E-03 4.66E-03 4.59E-03 Biased Statistics Average Biased 4.71E-03 4.77E-03 4.86E-03 4.95E-03 5.05E-03 Std Dev Biased 4.45E-05 5.55E-05 9.15E-05 1.15E-04 7.68E-05 Ps90%/90% (+KTL) Biased 4.84E-03 4.92E-03 5.11E-03 5.26E-03 5.26E-03 Ps90%/90% (-KTL) Biased 4.59E-03 4.61E-03 4.60E-03 4.63E-03 4.84E-03 Un-Biased Statistics Average Un-Biased 4.63E-03 4.74E-03 4.86E-03 5.02E-03 5.27E-03 Std Dev Un-Biased 3.70E-05 6.30E-05 9.07E-05 7.92E-05 9.94E-05 Ps90%/90% (+KTL) Un-Biased 4.73E-03 4.91E-03 5.11E-03 5.24E-03 5.55E-03 Ps90%/90% (-KTL) Un-Biased 4.53E-03 4.57E-03 4.61E-03 4.80E-03 5.00E-03 Specification MAX 1.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 291 Output Voltage Swing High5 1 (V) @ VS=+5V IL=1mA TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 1.60E-01 1.40E-01 1.20E-01 1.00E-01 8.00E-02 6.00E-02 4.00E-02 2.00E-02 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.141. Plot of Output Voltage Swing High5 1 (V) @ VS=+5V IL=1mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 292 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.141. Raw data for Output Voltage Swing High5 1 (V) @ VS=+5V IL=1mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Swing High5 1 (V) @ VS=+5V IL=1mA Device 0 20 50 100 200 519 6.98E-02 7.10E-02 7.22E-02 7.25E-02 7.32E-02 520 6.63E-02 6.75E-02 6.85E-02 6.93E-02 6.99E-02 521 6.62E-02 6.75E-02 6.81E-02 6.88E-02 6.95E-02 522 7.12E-02 7.23E-02 7.31E-02 7.38E-02 7.47E-02 524 6.60E-02 6.61E-02 6.76E-02 6.84E-02 6.90E-02 536 6.76E-02 6.77E-02 6.81E-02 6.87E-02 6.95E-02 537 6.85E-02 6.85E-02 6.90E-02 6.97E-02 7.03E-02 538 6.86E-02 6.90E-02 6.95E-02 7.01E-02 7.09E-02 539 6.76E-02 6.81E-02 6.84E-02 6.91E-02 6.98E-02 542 6.86E-02 6.89E-02 6.94E-02 7.00E-02 7.08E-02 543 6.67E-02 6.63E-02 6.62E-02 6.62E-02 6.64E-02 544 6.47E-02 6.46E-02 6.44E-02 6.47E-02 6.46E-02 Biased Statistics Average Biased 6.79E-02 6.89E-02 6.99E-02 7.06E-02 7.12E-02 Std Dev Biased 2.43E-03 2.62E-03 2.54E-03 2.41E-03 2.52E-03 Ps90%/90% (+KTL) Biased 7.45E-02 7.60E-02 7.69E-02 7.72E-02 7.82E-02 Ps90%/90% (-KTL) Biased 6.12E-02 6.17E-02 6.29E-02 6.39E-02 6.43E-02 Un-Biased Statistics Average Un-Biased 6.82E-02 6.84E-02 6.89E-02 6.95E-02 7.03E-02 Std Dev Un-Biased 5.23E-04 5.34E-04 6.20E-04 6.02E-04 6.23E-04 Ps90%/90% (+KTL) Un-Biased 6.96E-02 6.99E-02 7.06E-02 7.12E-02 7.20E-02 Ps90%/90% (-KTL) Un-Biased 6.67E-02 6.70E-02 6.72E-02 6.79E-02 6.85E-02 Specification MAX 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 293 Output Voltage Swing High5 2 (V) @ VS=+5V IL=1mA TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 1.60E-01 1.40E-01 1.20E-01 1.00E-01 8.00E-02 6.00E-02 4.00E-02 2.00E-02 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.142. Plot of Output Voltage Swing High5 2 (V) @ VS=+5V IL=1mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 294 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.142. Raw data for Output Voltage Swing High5 2 (V) @ VS=+5V IL=1mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Swing High5 2 (V) @ VS=+5V IL=1mA Device 0 20 50 100 200 519 6.90E-02 7.00E-02 7.13E-02 7.14E-02 7.23E-02 520 6.77E-02 6.90E-02 6.97E-02 7.06E-02 7.12E-02 521 6.68E-02 6.79E-02 6.86E-02 6.93E-02 7.00E-02 522 6.57E-02 6.67E-02 6.74E-02 6.79E-02 6.87E-02 524 6.48E-02 6.51E-02 6.65E-02 6.74E-02 6.81E-02 536 6.71E-02 6.76E-02 6.76E-02 6.84E-02 6.92E-02 537 6.85E-02 6.86E-02 6.89E-02 6.96E-02 7.04E-02 538 6.55E-02 6.60E-02 6.65E-02 6.69E-02 6.78E-02 539 6.89E-02 6.90E-02 6.95E-02 7.02E-02 7.10E-02 542 6.84E-02 6.88E-02 6.92E-02 6.99E-02 7.06E-02 543 6.44E-02 6.41E-02 6.41E-02 6.40E-02 6.41E-02 544 6.52E-02 6.50E-02 6.49E-02 6.49E-02 6.49E-02 Biased Statistics Average Biased 6.68E-02 6.77E-02 6.87E-02 6.93E-02 7.01E-02 Std Dev Biased 1.65E-03 1.92E-03 1.89E-03 1.71E-03 1.72E-03 Ps90%/90% (+KTL) Biased 7.13E-02 7.30E-02 7.39E-02 7.40E-02 7.48E-02 Ps90%/90% (-KTL) Biased 6.23E-02 6.25E-02 6.35E-02 6.47E-02 6.53E-02 Un-Biased Statistics Average Un-Biased 6.77E-02 6.80E-02 6.83E-02 6.90E-02 6.98E-02 Std Dev Un-Biased 1.39E-03 1.23E-03 1.25E-03 1.34E-03 1.31E-03 Ps90%/90% (+KTL) Un-Biased 7.15E-02 7.14E-02 7.18E-02 7.27E-02 7.34E-02 Ps90%/90% (-KTL) Un-Biased 6.39E-02 6.46E-02 6.49E-02 6.53E-02 6.62E-02 Specification MAX 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 295 Output Voltage Swing High5 3 (V) @ VS=+5V IL=1mA TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 1.60E-01 1.40E-01 1.20E-01 1.00E-01 8.00E-02 6.00E-02 4.00E-02 2.00E-02 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.143. Plot of Output Voltage Swing High5 3 (V) @ VS=+5V IL=1mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 296 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.143. Raw data for Output Voltage Swing High5 3 (V) @ VS=+5V IL=1mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Swing High5 3 (V) @ VS=+5V IL=1mA Device 0 20 50 100 200 519 6.89E-02 7.02E-02 7.15E-02 7.18E-02 7.23E-02 520 6.79E-02 6.91E-02 6.98E-02 7.10E-02 7.16E-02 521 6.68E-02 6.81E-02 6.89E-02 6.94E-02 7.02E-02 522 6.56E-02 6.65E-02 6.74E-02 6.80E-02 6.86E-02 524 6.51E-02 6.52E-02 6.67E-02 6.74E-02 6.82E-02 536 6.73E-02 6.73E-02 6.78E-02 6.84E-02 6.90E-02 537 6.88E-02 6.91E-02 6.94E-02 7.01E-02 7.09E-02 538 6.56E-02 6.60E-02 6.62E-02 6.69E-02 6.77E-02 539 6.88E-02 6.91E-02 6.95E-02 7.02E-02 7.10E-02 542 6.81E-02 6.83E-02 6.90E-02 6.95E-02 7.02E-02 543 6.50E-02 6.47E-02 6.47E-02 6.46E-02 6.47E-02 544 6.56E-02 6.53E-02 6.54E-02 6.55E-02 6.56E-02 Biased Statistics Average Biased 6.69E-02 6.78E-02 6.88E-02 6.95E-02 7.02E-02 Std Dev Biased 1.59E-03 2.00E-03 1.92E-03 1.87E-03 1.79E-03 Ps90%/90% (+KTL) Biased 7.12E-02 7.33E-02 7.41E-02 7.46E-02 7.51E-02 Ps90%/90% (-KTL) Biased 6.25E-02 6.23E-02 6.36E-02 6.44E-02 6.53E-02 Un-Biased Statistics Average Un-Biased 6.77E-02 6.80E-02 6.84E-02 6.90E-02 6.98E-02 Std Dev Un-Biased 1.33E-03 1.31E-03 1.38E-03 1.40E-03 1.40E-03 Ps90%/90% (+KTL) Un-Biased 7.14E-02 7.15E-02 7.22E-02 7.28E-02 7.36E-02 Ps90%/90% (-KTL) Un-Biased 6.41E-02 6.44E-02 6.46E-02 6.52E-02 6.59E-02 Specification MAX 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 297 Output Voltage Swing High5 4 (V) @ VS=+5V IL=1mA TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 1.60E-01 1.40E-01 1.20E-01 1.00E-01 8.00E-02 6.00E-02 4.00E-02 2.00E-02 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.144. Plot of Output Voltage Swing High5 4 (V) @ VS=+5V IL=1mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 298 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.144. Raw data for Output Voltage Swing High5 4 (V) @ VS=+5V IL=1mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Swing High5 4 (V) @ VS=+5V IL=1mA Device 0 20 50 100 200 519 7.04E-02 7.14E-02 7.28E-02 7.31E-02 7.36E-02 520 6.66E-02 6.81E-02 6.86E-02 6.92E-02 6.98E-02 521 6.62E-02 6.76E-02 6.83E-02 6.93E-02 6.98E-02 522 7.11E-02 7.24E-02 7.32E-02 7.39E-02 7.46E-02 524 6.61E-02 6.63E-02 6.76E-02 6.85E-02 6.92E-02 536 6.78E-02 6.79E-02 6.84E-02 6.91E-02 6.99E-02 537 6.79E-02 6.78E-02 6.84E-02 6.91E-02 6.98E-02 538 6.90E-02 6.92E-02 6.98E-02 7.03E-02 7.13E-02 539 6.77E-02 6.81E-02 6.87E-02 6.91E-02 6.98E-02 542 6.82E-02 6.85E-02 6.90E-02 6.98E-02 7.04E-02 543 6.63E-02 6.58E-02 6.59E-02 6.59E-02 6.60E-02 544 6.47E-02 6.43E-02 6.43E-02 6.43E-02 6.45E-02 Biased Statistics Average Biased 6.81E-02 6.92E-02 7.01E-02 7.08E-02 7.14E-02 Std Dev Biased 2.44E-03 2.62E-03 2.67E-03 2.50E-03 2.51E-03 Ps90%/90% (+KTL) Biased 7.48E-02 7.63E-02 7.74E-02 7.76E-02 7.83E-02 Ps90%/90% (-KTL) Biased 6.14E-02 6.20E-02 6.28E-02 6.39E-02 6.45E-02 Un-Biased Statistics Average Un-Biased 6.81E-02 6.83E-02 6.89E-02 6.95E-02 7.03E-02 Std Dev Un-Biased 5.38E-04 5.73E-04 5.66E-04 5.67E-04 6.39E-04 Ps90%/90% (+KTL) Un-Biased 6.96E-02 6.99E-02 7.04E-02 7.10E-02 7.20E-02 Ps90%/90% (-KTL) Un-Biased 6.66E-02 6.67E-02 6.73E-02 6.79E-02 6.85E-02 Specification MAX 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 299 Output Voltage Swing High6 1 (V) @ VS=+5V IL=2.5mA TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 3.00E-01 2.50E-01 2.00E-01 1.50E-01 1.00E-01 5.00E-02 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.145. Plot of Output Voltage Swing High6 1 (V) @ VS=+5V IL=2.5mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 300 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.145. Raw data for Output Voltage Swing High6 1 (V) @ VS=+5V IL=2.5mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Swing High6 1 (V) @ VS=+5V IL=2.5mA Device 0 20 50 100 200 519 1.27E-01 1.28E-01 1.30E-01 1.30E-01 1.31E-01 520 1.22E-01 1.23E-01 1.24E-01 1.25E-01 1.26E-01 521 1.22E-01 1.23E-01 1.24E-01 1.25E-01 1.26E-01 522 1.29E-01 1.30E-01 1.30E-01 1.31E-01 1.33E-01 524 1.22E-01 1.22E-01 1.23E-01 1.24E-01 1.26E-01 536 1.24E-01 1.24E-01 1.24E-01 1.25E-01 1.26E-01 537 1.25E-01 1.25E-01 1.25E-01 1.26E-01 1.27E-01 538 1.26E-01 1.26E-01 1.26E-01 1.27E-01 1.28E-01 539 1.24E-01 1.24E-01 1.25E-01 1.25E-01 1.26E-01 542 1.25E-01 1.25E-01 1.26E-01 1.27E-01 1.28E-01 543 1.22E-01 1.21E-01 1.21E-01 1.21E-01 1.22E-01 544 1.20E-01 1.19E-01 1.19E-01 1.19E-01 1.19E-01 Biased Statistics Average Biased 1.24E-01 1.25E-01 1.26E-01 1.27E-01 1.28E-01 Std Dev Biased 3.43E-03 3.38E-03 3.47E-03 3.23E-03 3.35E-03 Ps90%/90% (+KTL) Biased 1.34E-01 1.34E-01 1.36E-01 1.36E-01 1.37E-01 Ps90%/90% (-KTL) Biased 1.15E-01 1.16E-01 1.17E-01 1.18E-01 1.19E-01 Un-Biased Statistics Average Un-Biased 1.25E-01 1.25E-01 1.25E-01 1.26E-01 1.27E-01 Std Dev Un-Biased 8.31E-04 7.02E-04 8.57E-04 9.15E-04 8.81E-04 Ps90%/90% (+KTL) Un-Biased 1.27E-01 1.27E-01 1.28E-01 1.29E-01 1.30E-01 Ps90%/90% (-KTL) Un-Biased 1.22E-01 1.23E-01 1.23E-01 1.24E-01 1.25E-01 Specification MAX 2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 301 Output Voltage Swing High6 2 (V) @ VS=+5V IL=2.5mA TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 3.00E-01 2.50E-01 2.00E-01 1.50E-01 1.00E-01 5.00E-02 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.146. Plot of Output Voltage Swing High6 2 (V) @ VS=+5V IL=2.5mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 302 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.146. Raw data for Output Voltage Swing High6 2 (V) @ VS=+5V IL=2.5mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Swing High6 2 (V) @ VS=+5V IL=2.5mA Device 0 20 50 100 200 519 1.26E-01 1.27E-01 1.29E-01 1.29E-01 1.29E-01 520 1.24E-01 1.25E-01 1.26E-01 1.27E-01 1.28E-01 521 1.22E-01 1.23E-01 1.24E-01 1.25E-01 1.26E-01 522 1.21E-01 1.21E-01 1.22E-01 1.23E-01 1.24E-01 524 1.20E-01 1.20E-01 1.22E-01 1.23E-01 1.24E-01 536 1.24E-01 1.23E-01 1.24E-01 1.25E-01 1.26E-01 537 1.25E-01 1.25E-01 1.26E-01 1.26E-01 1.27E-01 538 1.21E-01 1.21E-01 1.22E-01 1.22E-01 1.23E-01 539 1.25E-01 1.26E-01 1.26E-01 1.27E-01 1.28E-01 542 1.25E-01 1.25E-01 1.26E-01 1.26E-01 1.28E-01 543 1.19E-01 1.19E-01 1.19E-01 1.19E-01 1.19E-01 544 1.20E-01 1.20E-01 1.19E-01 1.19E-01 1.20E-01 Biased Statistics Average Biased 1.22E-01 1.23E-01 1.25E-01 1.25E-01 1.26E-01 Std Dev Biased 2.38E-03 2.75E-03 2.86E-03 2.62E-03 2.46E-03 Ps90%/90% (+KTL) Biased 1.29E-01 1.31E-01 1.32E-01 1.32E-01 1.33E-01 Ps90%/90% (-KTL) Biased 1.16E-01 1.16E-01 1.17E-01 1.18E-01 1.20E-01 Un-Biased Statistics Average Un-Biased 1.24E-01 1.24E-01 1.25E-01 1.25E-01 1.26E-01 Std Dev Un-Biased 1.79E-03 1.86E-03 1.98E-03 1.85E-03 1.88E-03 Ps90%/90% (+KTL) Un-Biased 1.29E-01 1.29E-01 1.30E-01 1.30E-01 1.31E-01 Ps90%/90% (-KTL) Un-Biased 1.19E-01 1.19E-01 1.19E-01 1.20E-01 1.21E-01 Specification MAX 2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 303 Output Voltage Swing High6 3 (V) @ VS=+5V IL=2.5mA TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 3.00E-01 2.50E-01 2.00E-01 1.50E-01 1.00E-01 5.00E-02 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.147. Plot of Output Voltage Swing High6 3 (V) @ VS=+5V IL=2.5mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 304 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.147. Raw data for Output Voltage Swing High6 3 (V) @ VS=+5V IL=2.5mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Swing High6 3 (V) @ VS=+5V IL=2.5mA Device 0 20 50 100 200 519 1.26E-01 1.27E-01 1.29E-01 1.29E-01 1.30E-01 520 1.24E-01 1.25E-01 1.26E-01 1.27E-01 1.28E-01 521 1.22E-01 1.23E-01 1.24E-01 1.25E-01 1.26E-01 522 1.21E-01 1.21E-01 1.22E-01 1.23E-01 1.24E-01 524 1.20E-01 1.20E-01 1.22E-01 1.23E-01 1.24E-01 536 1.23E-01 1.24E-01 1.24E-01 1.25E-01 1.26E-01 537 1.25E-01 1.25E-01 1.26E-01 1.27E-01 1.28E-01 538 1.21E-01 1.21E-01 1.22E-01 1.22E-01 1.24E-01 539 1.26E-01 1.26E-01 1.26E-01 1.27E-01 1.28E-01 542 1.25E-01 1.24E-01 1.25E-01 1.26E-01 1.27E-01 543 1.20E-01 1.19E-01 1.19E-01 1.19E-01 1.19E-01 544 1.21E-01 1.20E-01 1.20E-01 1.20E-01 1.20E-01 Biased Statistics Average Biased 1.23E-01 1.23E-01 1.25E-01 1.25E-01 1.27E-01 Std Dev Biased 2.30E-03 2.75E-03 2.80E-03 2.60E-03 2.43E-03 Ps90%/90% (+KTL) Biased 1.29E-01 1.31E-01 1.32E-01 1.33E-01 1.33E-01 Ps90%/90% (-KTL) Biased 1.16E-01 1.16E-01 1.17E-01 1.18E-01 1.20E-01 Un-Biased Statistics Average Un-Biased 1.24E-01 1.24E-01 1.25E-01 1.25E-01 1.26E-01 Std Dev Un-Biased 1.88E-03 1.82E-03 1.87E-03 1.93E-03 1.90E-03 Ps90%/90% (+KTL) Un-Biased 1.29E-01 1.29E-01 1.30E-01 1.31E-01 1.32E-01 Ps90%/90% (-KTL) Un-Biased 1.19E-01 1.19E-01 1.19E-01 1.20E-01 1.21E-01 Specification MAX 2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 305 Output Voltage Swing High6 4 (V) @ VS=+5V IL=2.5mA TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 3.00E-01 2.50E-01 2.00E-01 1.50E-01 1.00E-01 5.00E-02 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.148. Plot of Output Voltage Swing High6 4 (V) @ VS=+5V IL=2.5mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 306 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.148. Raw data for Output Voltage Swing High6 4 (V) @ VS=+5V IL=2.5mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Swing High6 4 (V) @ VS=+5V IL=2.5mA Device 0 20 50 100 200 519 1.28E-01 1.29E-01 1.31E-01 1.31E-01 1.32E-01 520 1.22E-01 1.24E-01 1.25E-01 1.26E-01 1.26E-01 521 1.22E-01 1.23E-01 1.24E-01 1.25E-01 1.26E-01 522 1.29E-01 1.30E-01 1.31E-01 1.31E-01 1.33E-01 524 1.22E-01 1.22E-01 1.23E-01 1.24E-01 1.26E-01 536 1.24E-01 1.24E-01 1.25E-01 1.25E-01 1.26E-01 537 1.24E-01 1.24E-01 1.25E-01 1.26E-01 1.27E-01 538 1.26E-01 1.26E-01 1.27E-01 1.28E-01 1.29E-01 539 1.24E-01 1.24E-01 1.25E-01 1.26E-01 1.27E-01 542 1.25E-01 1.25E-01 1.25E-01 1.26E-01 1.27E-01 543 1.22E-01 1.21E-01 1.21E-01 1.21E-01 1.21E-01 544 1.19E-01 1.19E-01 1.19E-01 1.19E-01 1.19E-01 Biased Statistics Average Biased 1.25E-01 1.25E-01 1.27E-01 1.27E-01 1.28E-01 Std Dev Biased 3.37E-03 3.49E-03 3.69E-03 3.33E-03 3.45E-03 Ps90%/90% (+KTL) Biased 1.34E-01 1.35E-01 1.37E-01 1.37E-01 1.38E-01 Ps90%/90% (-KTL) Biased 1.15E-01 1.16E-01 1.16E-01 1.18E-01 1.19E-01 Un-Biased Statistics Average Un-Biased 1.25E-01 1.25E-01 1.25E-01 1.26E-01 1.27E-01 Std Dev Un-Biased 8.19E-04 8.19E-04 8.19E-04 8.67E-04 8.53E-04 Ps90%/90% (+KTL) Un-Biased 1.27E-01 1.27E-01 1.28E-01 1.28E-01 1.30E-01 Ps90%/90% (-KTL) Un-Biased 1.22E-01 1.23E-01 1.23E-01 1.24E-01 1.25E-01 Specification MAX 2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 307 Output Voltage Swing Low4 1 (V) @ VS=+5V IL=0mA TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 7.00E-02 6.00E-02 5.00E-02 4.00E-02 3.00E-02 2.00E-02 1.00E-02 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.149. Plot of Output Voltage Swing Low4 1 (V) @ VS=+5V IL=0mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 308 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.149. Raw data for Output Voltage Swing Low4 1 (V) @ VS=+5V IL=0mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Swing Low4 1 (V) @ VS=+5V IL=0mA Device 0 20 50 100 200 519 1.46E-02 1.46E-02 1.50E-02 1.48E-02 1.50E-02 520 1.45E-02 1.48E-02 1.48E-02 1.48E-02 1.51E-02 521 1.41E-02 1.42E-02 1.44E-02 1.43E-02 1.44E-02 522 1.43E-02 1.44E-02 1.45E-02 1.45E-02 1.48E-02 524 1.46E-02 1.46E-02 1.47E-02 1.48E-02 1.51E-02 536 1.47E-02 1.45E-02 1.48E-02 1.51E-02 1.56E-02 537 1.47E-02 1.47E-02 1.49E-02 1.52E-02 1.55E-02 538 1.43E-02 1.45E-02 1.47E-02 1.49E-02 1.53E-02 539 1.46E-02 1.46E-02 1.49E-02 1.51E-02 1.56E-02 542 1.41E-02 1.43E-02 1.45E-02 1.48E-02 1.52E-02 543 1.43E-02 1.41E-02 1.41E-02 1.43E-02 1.43E-02 544 1.43E-02 1.42E-02 1.41E-02 1.41E-02 1.42E-02 Biased Statistics Average Biased 1.44E-02 1.45E-02 1.47E-02 1.46E-02 1.49E-02 Std Dev Biased 2.13E-04 2.09E-04 2.34E-04 2.02E-04 2.88E-04 Ps90%/90% (+KTL) Biased 1.50E-02 1.51E-02 1.53E-02 1.52E-02 1.57E-02 Ps90%/90% (-KTL) Biased 1.38E-02 1.39E-02 1.40E-02 1.41E-02 1.41E-02 Un-Biased Statistics Average Un-Biased 1.45E-02 1.45E-02 1.48E-02 1.50E-02 1.54E-02 Std Dev Un-Biased 2.69E-04 1.68E-04 1.73E-04 1.68E-04 1.67E-04 Ps90%/90% (+KTL) Un-Biased 1.52E-02 1.50E-02 1.52E-02 1.55E-02 1.59E-02 Ps90%/90% (-KTL) Un-Biased 1.37E-02 1.41E-02 1.43E-02 1.45E-02 1.50E-02 Specification MAX 3.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 309 Output Voltage Swing Low4 2 (V) @ VS=+5V IL=0mA TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 7.00E-02 6.00E-02 5.00E-02 4.00E-02 3.00E-02 2.00E-02 1.00E-02 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.150. Plot of Output Voltage Swing Low4 2 (V) @ VS=+5V IL=0mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 310 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.150. Raw data for Output Voltage Swing Low4 2 (V) @ VS=+5V IL=0mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Swing Low4 2 (V) @ VS=+5V IL=0mA Device 0 20 50 100 200 519 1.46E-02 1.46E-02 1.49E-02 1.47E-02 1.49E-02 520 1.51E-02 1.52E-02 1.53E-02 1.51E-02 1.56E-02 521 1.46E-02 1.47E-02 1.49E-02 1.49E-02 1.52E-02 522 1.45E-02 1.47E-02 1.48E-02 1.49E-02 1.52E-02 524 1.46E-02 1.46E-02 1.48E-02 1.50E-02 1.51E-02 536 1.48E-02 1.48E-02 1.50E-02 1.53E-02 1.58E-02 537 1.45E-02 1.44E-02 1.48E-02 1.50E-02 1.54E-02 538 1.46E-02 1.47E-02 1.49E-02 1.51E-02 1.53E-02 539 1.46E-02 1.48E-02 1.48E-02 1.51E-02 1.54E-02 542 1.43E-02 1.43E-02 1.47E-02 1.48E-02 1.53E-02 543 1.45E-02 1.45E-02 1.45E-02 1.45E-02 1.46E-02 544 1.46E-02 1.47E-02 1.47E-02 1.48E-02 1.49E-02 Biased Statistics Average Biased 1.47E-02 1.48E-02 1.49E-02 1.49E-02 1.52E-02 Std Dev Biased 2.18E-04 2.65E-04 2.09E-04 1.24E-04 2.43E-04 Ps90%/90% (+KTL) Biased 1.53E-02 1.55E-02 1.55E-02 1.52E-02 1.59E-02 Ps90%/90% (-KTL) Biased 1.41E-02 1.40E-02 1.44E-02 1.46E-02 1.45E-02 Un-Biased Statistics Average Un-Biased 1.45E-02 1.46E-02 1.48E-02 1.51E-02 1.54E-02 Std Dev Un-Biased 1.82E-04 2.46E-04 1.20E-04 1.77E-04 1.75E-04 Ps90%/90% (+KTL) Un-Biased 1.50E-02 1.53E-02 1.51E-02 1.55E-02 1.59E-02 Ps90%/90% (-KTL) Un-Biased 1.40E-02 1.39E-02 1.45E-02 1.46E-02 1.50E-02 Specification MAX 3.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 311 Output Voltage Swing Low4 3 (V) @ VS=+5V IL=0mA TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 7.00E-02 6.00E-02 5.00E-02 4.00E-02 3.00E-02 2.00E-02 1.00E-02 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.151. Plot of Output Voltage Swing Low4 3 (V) @ VS=+5V IL=0mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 312 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.151. Raw data for Output Voltage Swing Low4 3 (V) @ VS=+5V IL=0mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Swing Low4 3 (V) @ VS=+5V IL=0mA Device 0 20 50 100 200 519 1.44E-02 1.44E-02 1.48E-02 1.47E-02 1.48E-02 520 1.47E-02 1.47E-02 1.49E-02 1.48E-02 1.51E-02 521 1.42E-02 1.45E-02 1.45E-02 1.47E-02 1.47E-02 522 1.43E-02 1.44E-02 1.46E-02 1.46E-02 1.48E-02 524 1.44E-02 1.45E-02 1.47E-02 1.47E-02 1.49E-02 536 1.46E-02 1.46E-02 1.47E-02 1.51E-02 1.54E-02 537 1.42E-02 1.41E-02 1.46E-02 1.48E-02 1.51E-02 538 1.42E-02 1.42E-02 1.45E-02 1.47E-02 1.53E-02 539 1.41E-02 1.43E-02 1.46E-02 1.47E-02 1.51E-02 542 1.41E-02 1.40E-02 1.43E-02 1.47E-02 1.50E-02 543 1.43E-02 1.44E-02 1.43E-02 1.43E-02 1.44E-02 544 1.42E-02 1.41E-02 1.41E-02 1.41E-02 1.42E-02 Biased Statistics Average Biased 1.44E-02 1.45E-02 1.47E-02 1.47E-02 1.48E-02 Std Dev Biased 1.72E-04 1.28E-04 1.56E-04 7.71E-05 1.43E-04 Ps90%/90% (+KTL) Biased 1.49E-02 1.48E-02 1.51E-02 1.49E-02 1.52E-02 Ps90%/90% (-KTL) Biased 1.39E-02 1.41E-02 1.42E-02 1.45E-02 1.45E-02 Un-Biased Statistics Average Un-Biased 1.42E-02 1.42E-02 1.45E-02 1.48E-02 1.52E-02 Std Dev Un-Biased 2.19E-04 2.15E-04 1.68E-04 1.58E-04 1.67E-04 Ps90%/90% (+KTL) Un-Biased 1.48E-02 1.48E-02 1.50E-02 1.52E-02 1.56E-02 Ps90%/90% (-KTL) Un-Biased 1.36E-02 1.37E-02 1.41E-02 1.44E-02 1.47E-02 Specification MAX 3.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 313 Output Voltage Swing Low4 4 (V) @ VS=+5V IL=0mA TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 7.00E-02 6.00E-02 5.00E-02 4.00E-02 3.00E-02 2.00E-02 1.00E-02 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.152. Plot of Output Voltage Swing Low4 4 (V) @ VS=+5V IL=0mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 314 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.152. Raw data for Output Voltage Swing Low4 4 (V) @ VS=+5V IL=0mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Swing Low4 4 (V) @ VS=+5V IL=0mA Device 0 20 50 100 200 519 1.47E-02 1.49E-02 1.51E-02 1.51E-02 1.52E-02 520 1.49E-02 1.50E-02 1.52E-02 1.51E-02 1.54E-02 521 1.45E-02 1.47E-02 1.48E-02 1.48E-02 1.49E-02 522 1.46E-02 1.46E-02 1.48E-02 1.46E-02 1.52E-02 524 1.47E-02 1.44E-02 1.49E-02 1.48E-02 1.49E-02 536 1.48E-02 1.48E-02 1.51E-02 1.53E-02 1.58E-02 537 1.48E-02 1.49E-02 1.49E-02 1.53E-02 1.58E-02 538 1.45E-02 1.45E-02 1.46E-02 1.49E-02 1.54E-02 539 1.50E-02 1.50E-02 1.53E-02 1.56E-02 1.59E-02 542 1.44E-02 1.44E-02 1.47E-02 1.51E-02 1.54E-02 543 1.47E-02 1.44E-02 1.44E-02 1.44E-02 1.45E-02 544 1.44E-02 1.43E-02 1.41E-02 1.42E-02 1.43E-02 Biased Statistics Average Biased 1.47E-02 1.47E-02 1.50E-02 1.49E-02 1.51E-02 Std Dev Biased 1.53E-04 2.52E-04 1.90E-04 2.07E-04 2.11E-04 Ps90%/90% (+KTL) Biased 1.51E-02 1.54E-02 1.55E-02 1.54E-02 1.57E-02 Ps90%/90% (-KTL) Biased 1.43E-02 1.40E-02 1.44E-02 1.43E-02 1.45E-02 Un-Biased Statistics Average Un-Biased 1.47E-02 1.47E-02 1.49E-02 1.52E-02 1.57E-02 Std Dev Un-Biased 2.53E-04 2.50E-04 2.63E-04 2.63E-04 2.40E-04 Ps90%/90% (+KTL) Un-Biased 1.54E-02 1.54E-02 1.56E-02 1.60E-02 1.63E-02 Ps90%/90% (-KTL) Un-Biased 1.40E-02 1.40E-02 1.42E-02 1.45E-02 1.50E-02 Specification MAX 3.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 315 Output Voltage Swing Low5 1 (V) @ VS=+5V IL=1mA TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 1.20E-01 1.00E-01 8.00E-02 6.00E-02 4.00E-02 2.00E-02 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.153. Plot of Output Voltage Swing Low5 1 (V) @ VS=+5V IL=1mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 316 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.153. Raw data for Output Voltage Swing Low5 1 (V) @ VS=+5V IL=1mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Swing Low5 1 (V) @ VS=+5V IL=1mA Device 0 20 50 100 200 519 3.35E-02 3.37E-02 3.40E-02 3.38E-02 3.44E-02 520 3.32E-02 3.33E-02 3.35E-02 3.35E-02 3.41E-02 521 3.27E-02 3.28E-02 3.28E-02 3.31E-02 3.32E-02 522 3.32E-02 3.31E-02 3.36E-02 3.36E-02 3.40E-02 524 3.32E-02 3.31E-02 3.35E-02 3.35E-02 3.41E-02 536 3.37E-02 3.36E-02 3.37E-02 3.40E-02 3.44E-02 537 3.33E-02 3.33E-02 3.34E-02 3.38E-02 3.41E-02 538 3.35E-02 3.35E-02 3.36E-02 3.41E-02 3.45E-02 539 3.37E-02 3.36E-02 3.39E-02 3.42E-02 3.47E-02 542 3.30E-02 3.32E-02 3.34E-02 3.35E-02 3.41E-02 543 3.29E-02 3.27E-02 3.27E-02 3.25E-02 3.28E-02 544 3.27E-02 3.28E-02 3.27E-02 3.28E-02 3.27E-02 Biased Statistics Average Biased 3.31E-02 3.32E-02 3.35E-02 3.35E-02 3.39E-02 Std Dev Biased 3.01E-04 3.22E-04 4.35E-04 2.35E-04 4.55E-04 Ps90%/90% (+KTL) Biased 3.40E-02 3.41E-02 3.47E-02 3.41E-02 3.52E-02 Ps90%/90% (-KTL) Biased 3.23E-02 3.23E-02 3.23E-02 3.29E-02 3.27E-02 Un-Biased Statistics Average Un-Biased 3.34E-02 3.35E-02 3.36E-02 3.39E-02 3.43E-02 Std Dev Un-Biased 2.85E-04 1.92E-04 2.04E-04 2.62E-04 2.64E-04 Ps90%/90% (+KTL) Un-Biased 3.42E-02 3.40E-02 3.41E-02 3.46E-02 3.51E-02 Ps90%/90% (-KTL) Un-Biased 3.27E-02 3.29E-02 3.30E-02 3.32E-02 3.36E-02 Specification MAX 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 317 Output Voltage Swing Low5 2 (V) @ VS=+5V IL=1mA TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 1.20E-01 1.00E-01 8.00E-02 6.00E-02 4.00E-02 2.00E-02 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.154. Plot of Output Voltage Swing Low5 2 (V) @ VS=+5V IL=1mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 318 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.154. Raw data for Output Voltage Swing Low5 2 (V) @ VS=+5V IL=1mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Swing Low5 2 (V) @ VS=+5V IL=1mA Device 0 20 50 100 200 519 3.35E-02 3.35E-02 3.40E-02 3.40E-02 3.42E-02 520 3.44E-02 3.46E-02 3.47E-02 3.46E-02 3.52E-02 521 3.32E-02 3.32E-02 3.35E-02 3.36E-02 3.39E-02 522 3.33E-02 3.35E-02 3.37E-02 3.37E-02 3.41E-02 524 3.38E-02 3.36E-02 3.41E-02 3.44E-02 3.46E-02 536 3.37E-02 3.36E-02 3.39E-02 3.39E-02 3.44E-02 537 3.37E-02 3.38E-02 3.38E-02 3.42E-02 3.47E-02 538 3.37E-02 3.36E-02 3.38E-02 3.40E-02 3.44E-02 539 3.35E-02 3.36E-02 3.37E-02 3.38E-02 3.44E-02 542 3.33E-02 3.33E-02 3.36E-02 3.40E-02 3.43E-02 543 3.37E-02 3.34E-02 3.35E-02 3.35E-02 3.34E-02 544 3.37E-02 3.35E-02 3.36E-02 3.36E-02 3.36E-02 Biased Statistics Average Biased 3.36E-02 3.37E-02 3.40E-02 3.41E-02 3.44E-02 Std Dev Biased 4.99E-04 5.22E-04 4.54E-04 4.47E-04 5.18E-04 Ps90%/90% (+KTL) Biased 3.50E-02 3.51E-02 3.52E-02 3.53E-02 3.58E-02 Ps90%/90% (-KTL) Biased 3.23E-02 3.22E-02 3.28E-02 3.28E-02 3.30E-02 Un-Biased Statistics Average Un-Biased 3.36E-02 3.36E-02 3.38E-02 3.40E-02 3.44E-02 Std Dev Un-Biased 1.69E-04 1.55E-04 1.09E-04 1.38E-04 1.45E-04 Ps90%/90% (+KTL) Un-Biased 3.40E-02 3.40E-02 3.41E-02 3.44E-02 3.48E-02 Ps90%/90% (-KTL) Un-Biased 3.31E-02 3.32E-02 3.35E-02 3.36E-02 3.40E-02 Specification MAX 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 319 Output Voltage Swing Low5 3 (V) @ VS=+5V IL=1mA TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 1.20E-01 1.00E-01 8.00E-02 6.00E-02 4.00E-02 2.00E-02 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.155. Plot of Output Voltage Swing Low5 3 (V) @ VS=+5V IL=1mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 320 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.155. Raw data for Output Voltage Swing Low5 3 (V) @ VS=+5V IL=1mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Swing Low5 3 (V) @ VS=+5V IL=1mA Device 0 20 50 100 200 519 3.33E-02 3.34E-02 3.40E-02 3.38E-02 3.41E-02 520 3.39E-02 3.39E-02 3.43E-02 3.41E-02 3.45E-02 521 3.28E-02 3.28E-02 3.32E-02 3.34E-02 3.36E-02 522 3.29E-02 3.30E-02 3.32E-02 3.34E-02 3.37E-02 524 3.33E-02 3.34E-02 3.36E-02 3.37E-02 3.41E-02 536 3.34E-02 3.33E-02 3.36E-02 3.38E-02 3.41E-02 537 3.33E-02 3.32E-02 3.34E-02 3.36E-02 3.39E-02 538 3.32E-02 3.32E-02 3.32E-02 3.34E-02 3.37E-02 539 3.30E-02 3.31E-02 3.33E-02 3.35E-02 3.39E-02 542 3.31E-02 3.31E-02 3.32E-02 3.34E-02 3.39E-02 543 3.34E-02 3.34E-02 3.32E-02 3.32E-02 3.31E-02 544 3.29E-02 3.28E-02 3.27E-02 3.29E-02 3.28E-02 Biased Statistics Average Biased 3.32E-02 3.33E-02 3.37E-02 3.37E-02 3.40E-02 Std Dev Biased 4.42E-04 4.26E-04 4.70E-04 3.04E-04 3.78E-04 Ps90%/90% (+KTL) Biased 3.45E-02 3.45E-02 3.50E-02 3.45E-02 3.50E-02 Ps90%/90% (-KTL) Biased 3.20E-02 3.22E-02 3.24E-02 3.29E-02 3.29E-02 Un-Biased Statistics Average Un-Biased 3.32E-02 3.32E-02 3.33E-02 3.35E-02 3.39E-02 Std Dev Un-Biased 1.73E-04 8.07E-05 1.54E-04 1.68E-04 1.28E-04 Ps90%/90% (+KTL) Un-Biased 3.36E-02 3.34E-02 3.37E-02 3.40E-02 3.43E-02 Ps90%/90% (-KTL) Un-Biased 3.27E-02 3.29E-02 3.29E-02 3.31E-02 3.35E-02 Specification MAX 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 321 Output Voltage Swing Low5 4 (V) @ VS=+5V IL=1mA TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 1.20E-01 1.00E-01 8.00E-02 6.00E-02 4.00E-02 2.00E-02 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.156. Plot of Output Voltage Swing Low5 4 (V) @ VS=+5V IL=1mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 322 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.156. Raw data for Output Voltage Swing Low5 4 (V) @ VS=+5V IL=1mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Swing Low5 4 (V) @ VS=+5V IL=1mA Device 0 20 50 100 200 519 3.41E-02 3.41E-02 3.47E-02 3.46E-02 3.49E-02 520 3.38E-02 3.39E-02 3.40E-02 3.41E-02 3.46E-02 521 3.35E-02 3.35E-02 3.38E-02 3.39E-02 3.42E-02 522 3.36E-02 3.36E-02 3.38E-02 3.40E-02 3.46E-02 524 3.34E-02 3.33E-02 3.37E-02 3.38E-02 3.40E-02 536 3.40E-02 3.41E-02 3.42E-02 3.44E-02 3.48E-02 537 3.38E-02 3.37E-02 3.39E-02 3.41E-02 3.45E-02 538 3.39E-02 3.38E-02 3.40E-02 3.42E-02 3.47E-02 539 3.43E-02 3.43E-02 3.45E-02 3.47E-02 3.51E-02 542 3.34E-02 3.34E-02 3.36E-02 3.39E-02 3.42E-02 543 3.34E-02 3.34E-02 3.31E-02 3.33E-02 3.33E-02 544 3.32E-02 3.31E-02 3.29E-02 3.31E-02 3.31E-02 Biased Statistics Average Biased 3.37E-02 3.37E-02 3.40E-02 3.41E-02 3.44E-02 Std Dev Biased 3.02E-04 3.33E-04 4.03E-04 2.94E-04 3.73E-04 Ps90%/90% (+KTL) Biased 3.45E-02 3.46E-02 3.51E-02 3.49E-02 3.55E-02 Ps90%/90% (-KTL) Biased 3.28E-02 3.27E-02 3.29E-02 3.33E-02 3.34E-02 Un-Biased Statistics Average Un-Biased 3.39E-02 3.39E-02 3.40E-02 3.42E-02 3.46E-02 Std Dev Un-Biased 3.11E-04 3.38E-04 3.47E-04 3.18E-04 3.43E-04 Ps90%/90% (+KTL) Un-Biased 3.47E-02 3.48E-02 3.50E-02 3.51E-02 3.56E-02 Ps90%/90% (-KTL) Un-Biased 3.30E-02 3.29E-02 3.31E-02 3.34E-02 3.37E-02 Specification MAX 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 323 Output Voltage Swing Low6 1 (V) @ VS=+5V IL=2.5mA TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 2.50E-01 2.00E-01 1.50E-01 1.00E-01 5.00E-02 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.157. Plot of Output Voltage Swing Low6 1 (V) @ VS=+5V IL=2.5mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 324 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.157. Raw data for Output Voltage Swing Low6 1 (V) @ VS=+5V IL=2.5mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Swing Low6 1 (V) @ VS=+5V IL=2.5mA Device 0 20 50 100 200 519 7.36E-02 7.37E-02 7.44E-02 7.42E-02 7.44E-02 520 7.28E-02 7.29E-02 7.31E-02 7.34E-02 7.39E-02 521 7.19E-02 7.21E-02 7.20E-02 7.23E-02 7.27E-02 522 7.32E-02 7.30E-02 7.33E-02 7.35E-02 7.41E-02 524 7.31E-02 7.28E-02 7.31E-02 7.34E-02 7.43E-02 536 7.37E-02 7.35E-02 7.37E-02 7.41E-02 7.45E-02 537 7.30E-02 7.28E-02 7.30E-02 7.34E-02 7.36E-02 538 7.36E-02 7.37E-02 7.37E-02 7.43E-02 7.45E-02 539 7.41E-02 7.39E-02 7.41E-02 7.44E-02 7.48E-02 542 7.28E-02 7.27E-02 7.29E-02 7.32E-02 7.37E-02 543 7.22E-02 7.17E-02 7.17E-02 7.17E-02 7.17E-02 544 7.18E-02 7.16E-02 7.15E-02 7.17E-02 7.18E-02 Biased Statistics Average Biased 7.29E-02 7.29E-02 7.32E-02 7.33E-02 7.39E-02 Std Dev Biased 6.14E-04 5.55E-04 8.43E-04 6.76E-04 6.83E-04 Ps90%/90% (+KTL) Biased 7.46E-02 7.44E-02 7.55E-02 7.52E-02 7.57E-02 Ps90%/90% (-KTL) Biased 7.12E-02 7.14E-02 7.09E-02 7.15E-02 7.20E-02 Un-Biased Statistics Average Un-Biased 7.35E-02 7.33E-02 7.34E-02 7.39E-02 7.42E-02 Std Dev Un-Biased 5.36E-04 5.40E-04 5.07E-04 5.66E-04 5.50E-04 Ps90%/90% (+KTL) Un-Biased 7.49E-02 7.48E-02 7.48E-02 7.54E-02 7.57E-02 Ps90%/90% (-KTL) Un-Biased 7.20E-02 7.18E-02 7.21E-02 7.23E-02 7.27E-02 Specification MAX 2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 325 Output Voltage Swing Low6 2 (V) @ VS=+5V IL=2.5mA TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 2.50E-01 2.00E-01 1.50E-01 1.00E-01 5.00E-02 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.158. Plot of Output Voltage Swing Low6 2 (V) @ VS=+5V IL=2.5mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 326 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.158. Raw data for Output Voltage Swing Low6 2 (V) @ VS=+5V IL=2.5mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Swing Low6 2 (V) @ VS=+5V IL=2.5mA Device 0 20 50 100 200 519 7.33E-02 7.33E-02 7.41E-02 7.38E-02 7.42E-02 520 7.48E-02 7.48E-02 7.50E-02 7.51E-02 7.59E-02 521 7.24E-02 7.25E-02 7.25E-02 7.30E-02 7.33E-02 522 7.28E-02 7.28E-02 7.29E-02 7.30E-02 7.37E-02 524 7.39E-02 7.37E-02 7.43E-02 7.44E-02 7.50E-02 536 7.38E-02 7.36E-02 7.36E-02 7.39E-02 7.44E-02 537 7.40E-02 7.37E-02 7.40E-02 7.42E-02 7.45E-02 538 7.35E-02 7.32E-02 7.35E-02 7.36E-02 7.42E-02 539 7.34E-02 7.33E-02 7.33E-02 7.37E-02 7.42E-02 542 7.33E-02 7.32E-02 7.34E-02 7.36E-02 7.41E-02 543 7.36E-02 7.32E-02 7.32E-02 7.32E-02 7.34E-02 544 7.31E-02 7.28E-02 7.28E-02 7.29E-02 7.28E-02 Biased Statistics Average Biased 7.34E-02 7.34E-02 7.38E-02 7.39E-02 7.44E-02 Std Dev Biased 9.64E-04 9.14E-04 1.02E-03 9.13E-04 1.04E-03 Ps90%/90% (+KTL) Biased 7.61E-02 7.59E-02 7.66E-02 7.64E-02 7.73E-02 Ps90%/90% (-KTL) Biased 7.08E-02 7.09E-02 7.10E-02 7.13E-02 7.16E-02 Un-Biased Statistics Average Un-Biased 7.36E-02 7.34E-02 7.35E-02 7.38E-02 7.43E-02 Std Dev Un-Biased 3.13E-04 2.33E-04 2.58E-04 2.75E-04 1.79E-04 Ps90%/90% (+KTL) Un-Biased 7.44E-02 7.40E-02 7.43E-02 7.46E-02 7.48E-02 Ps90%/90% (-KTL) Un-Biased 7.27E-02 7.28E-02 7.28E-02 7.30E-02 7.38E-02 Specification MAX 2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 327 Output Voltage Swing Low6 3 (V) @ VS=+5V IL=2.5mA TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 2.50E-01 2.00E-01 1.50E-01 1.00E-01 5.00E-02 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.159. Plot of Output Voltage Swing Low6 3 (V) @ VS=+5V IL=2.5mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 328 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.159. Raw data for Output Voltage Swing Low6 3 (V) @ VS=+5V IL=2.5mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Swing Low6 3 (V) @ VS=+5V IL=2.5mA Device 0 20 50 100 200 519 7.30E-02 7.30E-02 7.38E-02 7.35E-02 7.39E-02 520 7.39E-02 7.41E-02 7.44E-02 7.43E-02 7.51E-02 521 7.19E-02 7.19E-02 7.22E-02 7.25E-02 7.26E-02 522 7.19E-02 7.17E-02 7.20E-02 7.24E-02 7.26E-02 524 7.30E-02 7.29E-02 7.34E-02 7.36E-02 7.41E-02 536 7.33E-02 7.31E-02 7.31E-02 7.35E-02 7.39E-02 537 7.28E-02 7.26E-02 7.29E-02 7.32E-02 7.36E-02 538 7.23E-02 7.23E-02 7.24E-02 7.28E-02 7.31E-02 539 7.25E-02 7.25E-02 7.28E-02 7.29E-02 7.36E-02 542 7.25E-02 7.26E-02 7.27E-02 7.30E-02 7.35E-02 543 7.31E-02 7.26E-02 7.26E-02 7.28E-02 7.28E-02 544 7.21E-02 7.18E-02 7.18E-02 7.18E-02 7.18E-02 Biased Statistics Average Biased 7.28E-02 7.27E-02 7.31E-02 7.33E-02 7.36E-02 Std Dev Biased 8.54E-04 9.61E-04 1.03E-03 8.18E-04 1.08E-03 Ps90%/90% (+KTL) Biased 7.51E-02 7.53E-02 7.60E-02 7.55E-02 7.66E-02 Ps90%/90% (-KTL) Biased 7.04E-02 7.01E-02 7.03E-02 7.10E-02 7.07E-02 Un-Biased Statistics Average Un-Biased 7.27E-02 7.26E-02 7.28E-02 7.31E-02 7.35E-02 Std Dev Un-Biased 3.92E-04 2.87E-04 2.75E-04 2.83E-04 3.03E-04 Ps90%/90% (+KTL) Un-Biased 7.37E-02 7.34E-02 7.35E-02 7.39E-02 7.44E-02 Ps90%/90% (-KTL) Un-Biased 7.16E-02 7.18E-02 7.20E-02 7.23E-02 7.27E-02 Specification MAX 2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 329 Output Voltage Swing Low6 4 (V) @ VS=+5V IL=2.5mA TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 2.50E-01 2.00E-01 1.50E-01 1.00E-01 5.00E-02 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.160. Plot of Output Voltage Swing Low6 4 (V) @ VS=+5V IL=2.5mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 330 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.160. Raw data for Output Voltage Swing Low6 4 (V) @ VS=+5V IL=2.5mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Swing Low6 4 (V) @ VS=+5V IL=2.5mA Device 0 20 50 100 200 519 7.45E-02 7.46E-02 7.52E-02 7.51E-02 7.55E-02 520 7.35E-02 7.37E-02 7.40E-02 7.40E-02 7.47E-02 521 7.31E-02 7.33E-02 7.34E-02 7.37E-02 7.40E-02 522 7.36E-02 7.36E-02 7.38E-02 7.40E-02 7.47E-02 524 7.35E-02 7.32E-02 7.35E-02 7.37E-02 7.43E-02 536 7.43E-02 7.43E-02 7.42E-02 7.46E-02 7.50E-02 537 7.37E-02 7.36E-02 7.37E-02 7.39E-02 7.44E-02 538 7.42E-02 7.41E-02 7.43E-02 7.47E-02 7.50E-02 539 7.49E-02 7.45E-02 7.48E-02 7.51E-02 7.56E-02 542 7.34E-02 7.31E-02 7.35E-02 7.37E-02 7.42E-02 543 7.30E-02 7.25E-02 7.25E-02 7.25E-02 7.26E-02 544 7.25E-02 7.23E-02 7.23E-02 7.23E-02 7.24E-02 Biased Statistics Average Biased 7.36E-02 7.37E-02 7.40E-02 7.41E-02 7.47E-02 Std Dev Biased 5.08E-04 5.33E-04 7.39E-04 5.58E-04 5.71E-04 Ps90%/90% (+KTL) Biased 7.50E-02 7.51E-02 7.60E-02 7.56E-02 7.62E-02 Ps90%/90% (-KTL) Biased 7.22E-02 7.22E-02 7.19E-02 7.26E-02 7.31E-02 Un-Biased Statistics Average Un-Biased 7.41E-02 7.39E-02 7.41E-02 7.44E-02 7.48E-02 Std Dev Un-Biased 5.70E-04 5.72E-04 5.34E-04 5.95E-04 5.72E-04 Ps90%/90% (+KTL) Un-Biased 7.57E-02 7.55E-02 7.56E-02 7.60E-02 7.64E-02 Ps90%/90% (-KTL) Un-Biased 7.25E-02 7.23E-02 7.26E-02 7.27E-02 7.32E-02 Specification MAX 2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 331 Large Signal Voltage Gain3 1 (V/mV) @ VO=75mV to 4.8V, RL=10kΩ TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 1.00E+05 5.00E+04 0.00E+00 -5.00E+04 -1.00E+05 -1.50E+05 -2.00E+05 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.161. Plot of Large Signal Voltage Gain3 1 (V/mV) @ VO=75mV to 4.8V, RL=10kΩ versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 332 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.161. Raw data for Large Signal Voltage Gain3 1 (V/mV) @ VO=75mV to 4.8V, RL=10kΩ versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Large Signal Voltage Gain3 1 (V/mV) @ VO=75mV to 4.8V, RL=10kΩ Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 7.40E+03 4.47E+03 4.92E+03 2.20E+04 1.67E+04 1.15E+04 9.15E+04 1.49E+04 1.21E+04 4.24E+03 2.70E+04 9.94E+03 Total 20 4.33E+03 5.70E+03 3.17E+03 4.56E+04 3.75E+04 1.10E+04 9.01E+03 3.12E+04 2.05E+04 3.26E+03 2.68E+06 7.40E+03 200 2.99E+03 2.90E+03 4.22E+03 8.78E+03 1.03E+04 6.61E+03 4.90E+03 4.26E+03 2.06E+04 2.48E+03 3.33E+04 7.39E+03 1.11E+04 7.86E+03 3.27E+04 -1.04E+04 1.93E+04 2.06E+04 7.56E+04 -3.71E+04 1.51E+04 2.05E+04 7.14E+04 -4.11E+04 7.08E+03 3.54E+03 1.68E+04 -2.62E+03 5.83E+03 3.45E+03 1.53E+04 -3.63E+03 2.68E+04 3.63E+04 1.26E+05 -7.28E+04 6.00E+02 PASS 1.50E+04 1.10E+04 4.51E+04 -1.51E+04 3.00E+02 PASS 8.81E+03 4.11E+03 2.01E+04 -2.46E+03 3.00E+02 PASS 5.26E+04 7.20E+04 2.50E+05 -1.45E+05 3.00E+02 PASS 7.77E+03 7.31E+03 2.78E+04 -1.23E+04 3.00E+02 PASS An ISO 9001:2008 and DSCC Certified Company 333 Dose (krad(Si)) 50 100 3.53E+03 3.54E+03 3.54E+03 6.41E+03 5.10E+03 4.63E+03 5.13E+04 1.25E+04 1.23E+04 8.27E+03 6.57E+03 5.70E+04 9.05E+03 1.67E+04 1.15E+04 1.04E+04 1.37E+04 1.76E+05 3.22E+03 2.94E+03 4.07E+04 7.30E+04 8.41E+03 7.58E+03 Large Signal Voltage Gain3 2 (V/mV) @ VO=75mV to 4.8V, RL=10kΩ TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 6.00E+03 5.00E+03 4.00E+03 3.00E+03 2.00E+03 1.00E+03 0.00E+00 -1.00E+03 -2.00E+03 -3.00E+03 -4.00E+03 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.162. Plot of Large Signal Voltage Gain3 2 (V/mV) @ VO=75mV to 4.8V, RL=10kΩ versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 334 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.162. Raw data for Large Signal Voltage Gain3 2 (V/mV) @ VO=75mV to 4.8V, RL=10kΩ versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Large Signal Voltage Gain3 2 (V/mV) @ VO=75mV to 4.8V, RL=10kΩ Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 4.47E+03 2.69E+03 4.07E+03 3.75E+03 2.68E+03 3.66E+03 2.34E+03 2.86E+03 3.04E+03 4.01E+03 2.92E+03 3.04E+03 Total 20 4.67E+03 2.53E+03 5.55E+03 4.07E+03 3.19E+03 3.60E+03 5.60E+03 2.99E+03 3.39E+03 4.38E+03 2.59E+03 3.27E+03 Dose (krad(Si)) 50 100 5.69E+03 5.04E+03 2.72E+03 2.48E+03 4.30E+03 9.14E+03 3.22E+03 4.20E+03 2.23E+03 2.53E+03 2.53E+03 3.90E+03 3.43E+03 4.80E+03 2.64E+03 3.33E+03 3.08E+03 1.88E+03 3.61E+03 5.68E+03 2.76E+03 3.05E+03 3.13E+03 3.31E+03 200 4.14E+03 2.80E+03 3.74E+03 2.83E+03 3.28E+03 2.16E+03 3.94E+03 2.05E+03 2.64E+03 3.27E+03 2.56E+03 3.15E+03 3.53E+03 8.12E+02 5.75E+03 1.30E+03 4.00E+03 1.19E+03 7.26E+03 7.39E+02 3.63E+03 1.38E+03 7.42E+03 -1.60E+02 4.68E+03 2.73E+03 1.22E+04 -2.80E+03 3.36E+03 5.81E+02 4.95E+03 1.76E+03 3.18E+03 6.63E+02 5.00E+03 1.36E+03 6.00E+02 PASS 3.99E+03 1.03E+03 6.83E+03 1.16E+03 3.00E+02 PASS 3.06E+03 4.74E+02 4.36E+03 1.76E+03 3.00E+02 PASS 3.92E+03 1.45E+03 7.88E+03 -5.22E+01 3.00E+02 PASS 2.81E+03 7.96E+02 4.99E+03 6.26E+02 3.00E+02 PASS An ISO 9001:2008 and DSCC Certified Company 335 Large Signal Voltage Gain3 3 (V/mV) @ VO=75mV to 4.8V, RL=10kΩ TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 4.00E+03 3.50E+03 3.00E+03 2.50E+03 2.00E+03 1.50E+03 1.00E+03 5.00E+02 0.00E+00 -5.00E+02 -1.00E+03 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.163. Plot of Large Signal Voltage Gain3 3 (V/mV) @ VO=75mV to 4.8V, RL=10kΩ versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 336 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.163. Raw data for Large Signal Voltage Gain3 3 (V/mV) @ VO=75mV to 4.8V, RL=10kΩ versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Large Signal Voltage Gain3 3 (V/mV) @ VO=75mV to 4.8V, RL=10kΩ Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 2.40E+03 2.36E+03 5.01E+03 2.26E+03 2.31E+03 4.46E+03 3.70E+03 4.85E+03 1.78E+03 2.88E+03 2.52E+03 1.93E+03 Total 20 2.56E+03 2.36E+03 3.64E+03 2.31E+03 1.95E+03 4.45E+03 4.56E+03 4.04E+03 1.93E+03 2.89E+03 2.94E+03 3.30E+03 Dose (krad(Si)) 50 100 2.92E+03 2.77E+03 1.98E+03 2.60E+03 4.09E+03 3.56E+03 2.46E+03 2.10E+03 2.33E+03 1.71E+03 3.77E+03 3.59E+03 3.25E+03 2.62E+03 3.98E+03 2.89E+03 3.59E+03 1.68E+03 3.15E+03 3.79E+03 3.17E+03 3.34E+03 2.85E+03 3.48E+03 200 1.95E+03 2.05E+03 2.75E+03 2.22E+03 1.97E+03 3.36E+03 4.90E+03 2.09E+03 2.10E+03 3.23E+03 3.80E+03 2.10E+03 2.87E+03 1.20E+03 6.16E+03 -4.20E+02 2.56E+03 6.40E+02 4.32E+03 8.10E+02 2.75E+03 8.17E+02 4.99E+03 5.11E+02 2.55E+03 7.04E+02 4.48E+03 6.18E+02 2.19E+03 3.31E+02 3.09E+03 1.28E+03 3.53E+03 1.24E+03 6.93E+03 1.37E+02 6.00E+02 PASS 3.57E+03 1.13E+03 6.68E+03 4.65E+02 3.00E+02 PASS 3.55E+03 3.46E+02 4.50E+03 2.60E+03 3.00E+02 PASS 2.91E+03 8.40E+02 5.22E+03 6.09E+02 3.00E+02 PASS 3.14E+03 1.16E+03 6.31E+03 -3.46E+01 3.00E+02 PASS An ISO 9001:2008 and DSCC Certified Company 337 Large Signal Voltage Gain3 4 (V/mV) @ VO=75mV to 4.8V, RL=10kΩ TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 1.50E+04 1.00E+04 5.00E+03 0.00E+00 -5.00E+03 -1.00E+04 -1.50E+04 -2.00E+04 -2.50E+04 -3.00E+04 -3.50E+04 -4.00E+04 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.164. Plot of Large Signal Voltage Gain3 4 (V/mV) @ VO=75mV to 4.8V, RL=10kΩ versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 338 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.164. Raw data for Large Signal Voltage Gain3 4 (V/mV) @ VO=75mV to 4.8V, RL=10kΩ versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Large Signal Voltage Gain3 4 (V/mV) @ VO=75mV to 4.8V, RL=10kΩ Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 1.66E+03 3.79E+03 1.84E+03 3.48E+03 2.23E+03 1.29E+03 2.30E+03 1.76E+03 2.71E+03 2.72E+03 2.80E+03 2.77E+03 Total 20 3.80E+04 3.44E+03 2.14E+03 3.13E+03 2.22E+03 3.54E+03 2.35E+03 2.32E+03 2.74E+03 2.84E+03 2.95E+03 2.12E+03 200 2.74E+03 2.78E+03 1.68E+03 2.82E+03 1.75E+03 3.71E+03 1.89E+03 1.83E+03 2.42E+03 3.23E+03 2.69E+03 2.89E+03 2.60E+03 9.73E+02 5.27E+03 -6.76E+01 9.78E+03 1.58E+04 5.30E+04 -3.34E+04 2.55E+03 1.01E+03 5.31E+03 -2.21E+02 3.20E+03 2.12E+03 9.01E+03 -2.61E+03 2.35E+03 5.83E+02 3.95E+03 7.54E+02 2.16E+03 6.23E+02 3.87E+03 4.48E+02 6.00E+02 PASS 2.76E+03 4.94E+02 4.11E+03 1.40E+03 3.00E+02 PASS 3.12E+03 1.49E+03 7.20E+03 -9.53E+02 3.00E+02 PASS 2.50E+03 3.81E+02 3.55E+03 1.46E+03 3.00E+02 PASS 2.62E+03 8.29E+02 4.89E+03 3.41E+02 3.00E+02 PASS An ISO 9001:2008 and DSCC Certified Company 339 Dose (krad(Si)) 50 100 1.45E+03 1.50E+03 3.94E+03 2.67E+03 1.85E+03 2.56E+03 3.17E+03 6.90E+03 2.32E+03 2.36E+03 5.66E+03 3.14E+03 2.39E+03 2.16E+03 2.28E+03 2.30E+03 3.22E+03 2.52E+03 2.06E+03 2.39E+03 2.66E+03 3.02E+03 1.21E+04 2.91E+03 Common Mode Rejection Ratio2 1 (dB) @ VS=+5V, VCM=0 to +5V TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 1.00E+02 9.00E+01 8.00E+01 7.00E+01 6.00E+01 5.00E+01 4.00E+01 3.00E+01 2.00E+01 1.00E+01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.165. Plot of Common Mode Rejection Ratio2 1 (dB) @ VS=+5V, VCM=0 to +5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 340 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.165. Raw data for Common Mode Rejection Ratio2 1 (dB) @ VS=+5V, VCM=0 to +5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Common Mode Rejection Ratio2 1 (dB) @ VS=+5V, VCM=0 to +5V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 8.85E+01 9.02E+01 8.61E+01 8.45E+01 8.31E+01 8.90E+01 8.30E+01 9.52E+01 8.60E+01 9.04E+01 8.26E+01 8.14E+01 Total 20 8.85E+01 9.01E+01 8.67E+01 8.43E+01 8.31E+01 8.89E+01 8.31E+01 9.55E+01 8.58E+01 9.02E+01 8.26E+01 8.15E+01 Dose (krad(Si)) 50 100 8.85E+01 8.84E+01 8.99E+01 8.97E+01 8.65E+01 8.65E+01 8.41E+01 8.38E+01 8.32E+01 8.32E+01 8.88E+01 8.86E+01 8.30E+01 8.29E+01 9.45E+01 9.39E+01 8.57E+01 8.55E+01 8.98E+01 8.94E+01 8.26E+01 8.26E+01 8.14E+01 8.14E+01 200 8.82E+01 8.90E+01 8.62E+01 8.34E+01 8.30E+01 8.83E+01 8.28E+01 9.31E+01 8.53E+01 8.90E+01 8.26E+01 8.14E+01 8.65E+01 2.90E+00 9.44E+01 7.85E+01 8.65E+01 2.89E+00 9.44E+01 7.86E+01 8.64E+01 2.83E+00 9.42E+01 7.87E+01 8.63E+01 2.82E+00 9.41E+01 7.86E+01 8.60E+01 2.72E+00 9.34E+01 7.85E+01 8.87E+01 4.61E+00 1.01E+02 7.61E+01 7.60E+01 PASS 8.87E+01 4.72E+00 1.02E+02 7.58E+01 7.00E+01 PASS 8.84E+01 4.34E+00 1.00E+02 7.65E+01 7.00E+01 PASS 8.81E+01 4.15E+00 9.95E+01 7.67E+01 7.00E+01 PASS 8.77E+01 3.90E+00 9.84E+01 7.70E+01 7.00E+01 PASS An ISO 9001:2008 and DSCC Certified Company 341 Common Mode Rejection Ratio2 2 (dB) @ VS=+5V, VCM=0 to +5V TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 1.00E+02 9.00E+01 8.00E+01 7.00E+01 6.00E+01 5.00E+01 4.00E+01 3.00E+01 2.00E+01 1.00E+01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.166. Plot of Common Mode Rejection Ratio2 2 (dB) @ VS=+5V, VCM=0 to +5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 342 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.166. Raw data for Common Mode Rejection Ratio2 2 (dB) @ VS=+5V, VCM=0 to +5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Common Mode Rejection Ratio2 2 (dB) @ VS=+5V, VCM=0 to +5V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 8.61E+01 1.03E+02 8.60E+01 8.31E+01 1.05E+02 1.14E+02 8.41E+01 8.35E+01 8.34E+01 8.50E+01 8.50E+01 9.16E+01 Total 20 8.57E+01 1.01E+02 8.64E+01 8.31E+01 1.01E+02 1.15E+02 8.36E+01 8.35E+01 8.35E+01 8.48E+01 8.51E+01 9.16E+01 Dose (krad(Si)) 50 100 8.57E+01 8.56E+01 9.97E+01 9.91E+01 8.65E+01 8.65E+01 8.29E+01 8.29E+01 1.03E+02 1.06E+02 1.29E+02 1.38E+02 8.35E+01 8.34E+01 8.34E+01 8.33E+01 8.33E+01 8.31E+01 8.47E+01 8.46E+01 8.51E+01 8.51E+01 9.15E+01 9.16E+01 200 8.52E+01 9.77E+01 8.63E+01 8.27E+01 1.12E+02 1.14E+02 8.33E+01 8.32E+01 8.30E+01 8.45E+01 8.51E+01 9.16E+01 9.28E+01 1.06E+01 1.22E+02 6.37E+01 9.14E+01 8.73E+00 1.15E+02 6.74E+01 9.15E+01 9.06E+00 1.16E+02 6.67E+01 9.20E+01 1.00E+01 1.19E+02 6.45E+01 9.27E+01 1.20E+01 1.26E+02 5.98E+01 9.00E+01 1.34E+01 1.27E+02 5.32E+01 7.60E+01 PASS 9.02E+01 1.42E+01 1.29E+02 5.13E+01 7.00E+01 PASS 9.28E+01 2.02E+01 1.48E+02 3.75E+01 7.00E+01 PASS 9.45E+01 2.43E+01 1.61E+02 2.78E+01 7.00E+01 PASS 8.95E+01 1.35E+01 1.27E+02 5.24E+01 7.00E+01 PASS An ISO 9001:2008 and DSCC Certified Company 343 Common Mode Rejection Ratio2 3 (dB) @ VS=+5V, VCM=0 to +5V TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.167. Plot of Common Mode Rejection Ratio2 3 (dB) @ VS=+5V, VCM=0 to +5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 344 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.167. Raw data for Common Mode Rejection Ratio2 3 (dB) @ VS=+5V, VCM=0 to +5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Common Mode Rejection Ratio2 3 (dB) @ VS=+5V, VCM=0 to +5V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 8.79E+01 8.16E+01 8.31E+01 9.25E+01 1.06E+02 8.53E+01 9.57E+01 8.47E+01 8.60E+01 9.80E+01 9.94E+01 8.74E+01 Total 20 8.63E+01 8.17E+01 8.31E+01 9.34E+01 1.09E+02 8.53E+01 9.44E+01 8.46E+01 8.58E+01 9.84E+01 9.89E+01 8.74E+01 Dose (krad(Si)) 50 100 8.64E+01 8.66E+01 8.16E+01 8.14E+01 8.31E+01 8.30E+01 9.28E+01 9.23E+01 1.15E+02 1.40E+02 8.51E+01 8.50E+01 9.41E+01 9.35E+01 8.45E+01 8.43E+01 8.56E+01 8.55E+01 9.96E+01 1.02E+02 9.88E+01 9.89E+01 8.73E+01 8.73E+01 200 8.65E+01 8.13E+01 8.29E+01 9.17E+01 1.14E+02 8.49E+01 9.29E+01 8.41E+01 8.53E+01 1.04E+02 9.89E+01 8.73E+01 9.02E+01 9.78E+00 1.17E+02 6.34E+01 9.06E+01 1.11E+01 1.21E+02 6.01E+01 9.17E+01 1.35E+01 1.29E+02 5.46E+01 9.66E+01 2.44E+01 1.63E+02 2.97E+01 9.13E+01 1.33E+01 1.28E+02 5.49E+01 8.99E+01 6.38E+00 1.07E+02 7.24E+01 7.60E+01 PASS 8.97E+01 6.30E+00 1.07E+02 7.24E+01 7.00E+01 PASS 8.98E+01 6.76E+00 1.08E+02 7.13E+01 7.00E+01 PASS 9.00E+01 7.52E+00 1.11E+02 6.94E+01 7.00E+01 PASS 9.03E+01 8.61E+00 1.14E+02 6.67E+01 7.00E+01 PASS An ISO 9001:2008 and DSCC Certified Company 345 Common Mode Rejection Ratio2 4 (dB) @ VS=+5V, VCM=0 to +5V TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 1.00E+02 9.00E+01 8.00E+01 7.00E+01 6.00E+01 5.00E+01 4.00E+01 3.00E+01 2.00E+01 1.00E+01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.168. Plot of Common Mode Rejection Ratio2 4 (dB) @ VS=+5V, VCM=0 to +5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 346 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.168. Raw data for Common Mode Rejection Ratio2 4 (dB) @ VS=+5V, VCM=0 to +5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Common Mode Rejection Ratio2 4 (dB) @ VS=+5V, VCM=0 to +5V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 8.67E+01 9.94E+01 1.00E+02 9.19E+01 9.07E+01 1.10E+02 8.09E+01 9.92E+01 8.56E+01 9.20E+01 9.06E+01 9.13E+01 Total 20 8.67E+01 9.74E+01 9.95E+01 9.14E+01 9.03E+01 1.07E+02 8.08E+01 9.74E+01 8.55E+01 9.18E+01 9.08E+01 9.12E+01 Dose (krad(Si)) 50 100 8.66E+01 8.67E+01 9.70E+01 9.62E+01 9.91E+01 9.84E+01 9.13E+01 9.10E+01 9.03E+01 9.02E+01 1.06E+02 1.05E+02 8.09E+01 8.09E+01 9.72E+01 9.62E+01 8.53E+01 8.52E+01 9.16E+01 9.15E+01 9.09E+01 9.09E+01 9.11E+01 9.12E+01 200 8.65E+01 9.53E+01 9.74E+01 9.06E+01 8.98E+01 1.03E+02 8.09E+01 9.56E+01 8.50E+01 9.13E+01 9.08E+01 9.12E+01 9.38E+01 5.89E+00 1.10E+02 7.77E+01 9.30E+01 5.28E+00 1.08E+02 7.86E+01 9.29E+01 5.13E+00 1.07E+02 7.88E+01 9.25E+01 4.72E+00 1.05E+02 7.96E+01 9.19E+01 4.40E+00 1.04E+02 7.98E+01 9.34E+01 1.13E+01 1.24E+02 6.24E+01 7.60E+01 PASS 9.26E+01 1.03E+01 1.21E+02 6.43E+01 7.00E+01 PASS 9.22E+01 9.94E+00 1.19E+02 6.50E+01 7.00E+01 PASS 9.17E+01 9.30E+00 1.17E+02 6.62E+01 7.00E+01 PASS 9.11E+01 8.62E+00 1.15E+02 6.75E+01 7.00E+01 PASS An ISO 9001:2008 and DSCC Certified Company 347 CMRR Match2 1 to 4 (dB) @ VS=+5V, VCM=0 to +5V TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.169. Plot of CMRR Match2 1 to 4 (dB) @ VS=+5V, VCM=0 to +5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 348 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.169. Raw data for CMRR Match2 1 to 4 (dB) @ VS=+5V, VCM=0 to +5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). CMRR Match2 1 to 4 (dB) @ VS=+5V, VCM=0 to +5V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 1.01E+02 9.39E+01 8.80E+01 8.94E+01 8.77E+01 8.99E+01 9.39E+01 1.04E+02 1.13E+02 1.06E+02 7.97E+01 8.48E+01 Total 20 1.01E+02 9.50E+01 8.89E+01 8.93E+01 8.81E+01 9.01E+01 9.38E+01 1.10E+02 1.14E+02 1.05E+02 7.98E+01 8.49E+01 Dose (krad(Si)) 50 100 1.01E+02 1.02E+02 9.49E+01 9.52E+01 8.88E+01 8.90E+01 8.91E+01 8.87E+01 8.83E+01 8.84E+01 9.00E+01 9.01E+01 9.41E+01 9.44E+01 1.06E+02 1.06E+02 1.13E+02 1.14E+02 1.05E+02 1.03E+02 7.98E+01 7.98E+01 8.49E+01 8.49E+01 200 1.01E+02 9.47E+01 8.90E+01 8.85E+01 8.83E+01 9.01E+01 9.47E+01 1.05E+02 1.15E+02 1.01E+02 7.98E+01 8.48E+01 9.21E+01 5.80E+00 1.08E+02 7.62E+01 9.25E+01 5.49E+00 1.08E+02 7.74E+01 9.23E+01 5.33E+00 1.07E+02 7.77E+01 9.26E+01 5.86E+00 1.09E+02 7.65E+01 9.24E+01 5.66E+00 1.08E+02 7.68E+01 1.01E+02 9.55E+00 1.28E+02 7.53E+01 7.50E+01 PASS 1.03E+02 1.04E+01 1.31E+02 7.42E+01 7.00E+01 PASS 1.02E+02 9.34E+00 1.27E+02 7.59E+01 7.00E+01 PASS 1.02E+02 9.45E+00 1.27E+02 7.56E+01 7.00E+01 PASS 1.01E+02 9.55E+00 1.27E+02 7.51E+01 7.00E+01 PASS An ISO 9001:2008 and DSCC Certified Company 349 CMRR Match2 2 to 3 (dB) @ VS=+5V, VCM=0 to +5V TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.170. Plot of CMRR Match2 2 to 3 (dB) @ VS=+5V, VCM=0 to +5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 350 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.170. Raw data for CMRR Match2 2 to 3 (dB) @ VS=+5V, VCM=0 to +5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). CMRR Match2 2 to 3 (dB) @ VS=+5V, VCM=0 to +5V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 1.01E+02 8.24E+01 9.40E+01 8.67E+01 1.28E+02 8.49E+01 8.67E+01 1.01E+02 9.53E+01 8.33E+01 8.35E+01 9.57E+01 Total 20 1.09E+02 8.27E+01 9.29E+01 8.62E+01 1.05E+02 8.50E+01 8.65E+01 1.01E+02 9.63E+01 8.32E+01 8.35E+01 9.59E+01 Dose (krad(Si)) 50 100 1.08E+02 1.05E+02 8.27E+01 8.27E+01 9.28E+01 9.26E+01 8.63E+01 8.64E+01 1.05E+02 1.06E+02 8.51E+01 8.50E+01 8.66E+01 8.66E+01 1.02E+02 1.02E+02 9.60E+01 9.55E+01 8.33E+01 8.35E+01 8.35E+01 8.35E+01 9.55E+01 9.56E+01 200 1.03E+02 8.27E+01 9.26E+01 8.65E+01 1.07E+02 8.52E+01 8.67E+01 1.03E+02 9.54E+01 8.36E+01 8.35E+01 9.56E+01 9.84E+01 1.82E+01 1.48E+02 4.86E+01 9.52E+01 1.16E+01 1.27E+02 6.35E+01 9.50E+01 1.12E+01 1.26E+02 6.42E+01 9.45E+01 1.06E+01 1.23E+02 6.56E+01 9.42E+01 1.02E+01 1.22E+02 6.61E+01 9.03E+01 7.64E+00 1.11E+02 6.93E+01 7.50E+01 PASS 9.05E+01 7.95E+00 1.12E+02 6.87E+01 7.00E+01 PASS 9.06E+01 8.04E+00 1.13E+02 6.85E+01 7.00E+01 PASS 9.06E+01 8.08E+00 1.13E+02 6.85E+01 7.00E+01 PASS 9.08E+01 8.18E+00 1.13E+02 6.83E+01 7.00E+01 PASS An ISO 9001:2008 and DSCC Certified Company 351 Power Supply Rejection Ratio2 1 (dB) @ VS=+4.5V to +12V TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.171. Plot of Power Supply Rejection Ratio2 1 (dB) @ VS=+4.5V to +12V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 352 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.171. Raw data for Power Supply Rejection Ratio2 1 (dB) @ VS=+4.5V to +12V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Power Supply Rejection Ratio2 1 (dB) @ VS=+4.5V to +12V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 1.12E+02 1.06E+02 1.13E+02 1.25E+02 1.09E+02 1.07E+02 1.07E+02 1.15E+02 1.18E+02 1.16E+02 1.15E+02 1.25E+02 Total 20 1.12E+02 1.06E+02 1.13E+02 1.26E+02 1.09E+02 1.07E+02 1.07E+02 1.15E+02 1.18E+02 1.16E+02 1.15E+02 1.26E+02 Dose (krad(Si)) 50 100 1.12E+02 1.12E+02 1.06E+02 1.06E+02 1.13E+02 1.13E+02 1.28E+02 1.28E+02 1.10E+02 1.09E+02 1.07E+02 1.07E+02 1.07E+02 1.07E+02 1.15E+02 1.15E+02 1.18E+02 1.18E+02 1.16E+02 1.16E+02 1.14E+02 1.15E+02 1.26E+02 1.25E+02 200 1.12E+02 1.06E+02 1.13E+02 1.29E+02 1.09E+02 1.07E+02 1.07E+02 1.16E+02 1.19E+02 1.17E+02 1.15E+02 1.25E+02 1.13E+02 7.17E+00 1.33E+02 9.35E+01 1.13E+02 7.68E+00 1.35E+02 9.24E+01 1.14E+02 8.09E+00 1.36E+02 9.17E+01 1.14E+02 8.44E+00 1.37E+02 9.07E+01 1.14E+02 8.86E+00 1.38E+02 8.96E+01 1.12E+02 5.31E+00 1.27E+02 9.78E+01 8.80E+01 PASS 1.13E+02 5.41E+00 1.27E+02 9.77E+01 8.80E+01 PASS 1.13E+02 5.40E+00 1.27E+02 9.78E+01 8.80E+01 PASS 1.13E+02 5.52E+00 1.28E+02 9.76E+01 8.80E+01 PASS 1.13E+02 5.80E+00 1.29E+02 9.72E+01 8.80E+01 PASS An ISO 9001:2008 and DSCC Certified Company 353 Power Supply Rejection Ratio2 2 (dB) @ VS=+4.5V to +12V TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.172. Plot of Power Supply Rejection Ratio2 2 (dB) @ VS=+4.5V to +12V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 354 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.172. Raw data for Power Supply Rejection Ratio2 2 (dB) @ VS=+4.5V to +12V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Power Supply Rejection Ratio2 2 (dB) @ VS=+4.5V to +12V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 1.10E+02 1.12E+02 1.30E+02 1.17E+02 1.11E+02 1.08E+02 1.46E+02 1.17E+02 1.14E+02 1.07E+02 1.07E+02 1.36E+02 Total 20 1.11E+02 1.12E+02 1.31E+02 1.17E+02 1.11E+02 1.08E+02 1.43E+02 1.17E+02 1.14E+02 1.07E+02 1.08E+02 1.39E+02 Dose (krad(Si)) 50 100 1.11E+02 1.11E+02 1.12E+02 1.12E+02 1.31E+02 1.29E+02 1.17E+02 1.17E+02 1.11E+02 1.11E+02 1.08E+02 1.08E+02 1.49E+02 1.43E+02 1.17E+02 1.17E+02 1.14E+02 1.14E+02 1.07E+02 1.08E+02 1.07E+02 1.08E+02 1.39E+02 1.38E+02 200 1.11E+02 1.12E+02 1.27E+02 1.16E+02 1.11E+02 1.08E+02 1.35E+02 1.17E+02 1.14E+02 1.07E+02 1.08E+02 1.37E+02 1.16E+02 8.36E+00 1.39E+02 9.30E+01 1.16E+02 8.56E+00 1.40E+02 9.28E+01 1.16E+02 8.53E+00 1.40E+02 9.30E+01 1.16E+02 7.87E+00 1.37E+02 9.43E+01 1.15E+02 7.08E+00 1.35E+02 9.60E+01 1.18E+02 1.60E+01 1.62E+02 7.45E+01 8.80E+01 PASS 1.18E+02 1.47E+01 1.58E+02 7.76E+01 8.80E+01 PASS 1.19E+02 1.74E+01 1.67E+02 7.14E+01 8.80E+01 PASS 1.18E+02 1.47E+01 1.58E+02 7.76E+01 8.80E+01 PASS 1.16E+02 1.10E+01 1.46E+02 8.60E+01 8.80E+01 PASS An ISO 9001:2008 and DSCC Certified Company 355 Power Supply Rejection Ratio2 3 (dB) @ VS=+4.5V to +12V TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.173. Plot of Power Supply Rejection Ratio2 3 (dB) @ VS=+4.5V to +12V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 356 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.173. Raw data for Power Supply Rejection Ratio2 3 (dB) @ VS=+4.5V to +12V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Power Supply Rejection Ratio2 3 (dB) @ VS=+4.5V to +12V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 1.16E+02 1.04E+02 1.24E+02 1.18E+02 1.39E+02 1.66E+02 1.21E+02 1.10E+02 1.15E+02 1.14E+02 1.09E+02 1.08E+02 Total 20 1.16E+02 1.04E+02 1.24E+02 1.18E+02 1.34E+02 1.65E+02 1.20E+02 1.10E+02 1.15E+02 1.15E+02 1.09E+02 1.09E+02 Dose (krad(Si)) 50 100 1.16E+02 1.15E+02 1.04E+02 1.04E+02 1.24E+02 1.24E+02 1.18E+02 1.18E+02 1.30E+02 1.29E+02 1.55E+02 1.50E+02 1.21E+02 1.21E+02 1.10E+02 1.10E+02 1.15E+02 1.15E+02 1.15E+02 1.15E+02 1.09E+02 1.09E+02 1.09E+02 1.09E+02 200 1.15E+02 1.04E+02 1.25E+02 1.18E+02 1.27E+02 1.44E+02 1.22E+02 1.11E+02 1.15E+02 1.15E+02 1.09E+02 1.09E+02 1.20E+02 1.27E+01 1.55E+02 8.51E+01 1.19E+02 1.13E+01 1.50E+02 8.83E+01 1.18E+02 9.76E+00 1.45E+02 9.16E+01 1.18E+02 9.61E+00 1.44E+02 9.16E+01 1.18E+02 9.42E+00 1.44E+02 9.20E+01 1.25E+02 2.30E+01 1.88E+02 6.20E+01 8.80E+01 PASS 1.25E+02 2.29E+01 1.88E+02 6.22E+01 8.80E+01 PASS 1.23E+02 1.82E+01 1.73E+02 7.33E+01 8.80E+01 PASS 1.22E+02 1.61E+01 1.66E+02 7.80E+01 8.80E+01 PASS 1.21E+02 1.33E+01 1.58E+02 8.49E+01 8.80E+01 PASS An ISO 9001:2008 and DSCC Certified Company 357 Power Supply Rejection Ratio2 4 (dB) @ VS=+4.5V to +12V TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.174. Plot of Power Supply Rejection Ratio2 4 (dB) @ VS=+4.5V to +12V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 358 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.174. Raw data for Power Supply Rejection Ratio2 4 (dB) @ VS=+4.5V to +12V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Power Supply Rejection Ratio2 4 (dB) @ VS=+4.5V to +12V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 1.06E+02 1.09E+02 1.07E+02 1.06E+02 1.10E+02 1.15E+02 1.10E+02 1.11E+02 1.13E+02 1.08E+02 1.15E+02 1.38E+02 Total 20 1.06E+02 1.09E+02 1.08E+02 1.06E+02 1.11E+02 1.15E+02 1.10E+02 1.12E+02 1.13E+02 1.08E+02 1.15E+02 1.42E+02 Dose (krad(Si)) 50 100 1.06E+02 1.06E+02 1.09E+02 1.09E+02 1.08E+02 1.08E+02 1.06E+02 1.06E+02 1.11E+02 1.11E+02 1.15E+02 1.15E+02 1.10E+02 1.10E+02 1.12E+02 1.11E+02 1.13E+02 1.13E+02 1.08E+02 1.08E+02 1.15E+02 1.15E+02 1.39E+02 1.38E+02 200 1.06E+02 1.09E+02 1.08E+02 1.06E+02 1.10E+02 1.15E+02 1.10E+02 1.11E+02 1.13E+02 1.08E+02 1.15E+02 1.38E+02 1.08E+02 1.88E+00 1.13E+02 1.03E+02 1.08E+02 1.87E+00 1.13E+02 1.03E+02 1.08E+02 2.00E+00 1.13E+02 1.02E+02 1.08E+02 1.94E+00 1.13E+02 1.03E+02 1.08E+02 1.85E+00 1.13E+02 1.03E+02 1.11E+02 2.62E+00 1.19E+02 1.04E+02 8.80E+01 PASS 1.12E+02 2.69E+00 1.19E+02 1.04E+02 8.80E+01 PASS 1.12E+02 2.81E+00 1.19E+02 1.04E+02 8.80E+01 PASS 1.11E+02 2.76E+00 1.19E+02 1.04E+02 8.80E+01 PASS 1.11E+02 2.91E+00 1.19E+02 1.03E+02 8.80E+01 PASS An ISO 9001:2008 and DSCC Certified Company 359 TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased PSRR Match2 1 to 4 (dB) @ VS=+4.5V to +12V 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.175. Plot of PSRR Match2 1 to 4 (dB) @ VS=+4.5V to +12V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 360 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.175. Raw data for PSRR Match2 1 to 4 (dB) @ VS=+4.5V to +12V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). PSRR Match2 1 to 4 (dB) @ VS=+4.5V to +12V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 1.12E+02 1.17E+02 1.14E+02 1.07E+02 1.29E+02 1.11E+02 1.17E+02 1.20E+02 1.20E+02 1.13E+02 1.52E+02 1.27E+02 Total 20 1.12E+02 1.17E+02 1.14E+02 1.07E+02 1.27E+02 1.11E+02 1.17E+02 1.21E+02 1.20E+02 1.13E+02 1.43E+02 1.27E+02 Dose (krad(Si)) 50 100 1.11E+02 1.12E+02 1.17E+02 1.17E+02 1.14E+02 1.14E+02 1.07E+02 1.07E+02 1.30E+02 1.27E+02 1.11E+02 1.11E+02 1.18E+02 1.17E+02 1.21E+02 1.20E+02 1.21E+02 1.20E+02 1.12E+02 1.12E+02 1.39E+02 1.47E+02 1.28E+02 1.28E+02 200 1.13E+02 1.17E+02 1.14E+02 1.07E+02 1.28E+02 1.11E+02 1.18E+02 1.19E+02 1.20E+02 1.11E+02 1.53E+02 1.27E+02 1.16E+02 8.00E+00 1.38E+02 9.37E+01 1.16E+02 7.22E+00 1.35E+02 9.59E+01 1.16E+02 8.68E+00 1.40E+02 9.21E+01 1.16E+02 7.50E+00 1.36E+02 9.51E+01 1.16E+02 7.64E+00 1.37E+02 9.48E+01 1.16E+02 4.39E+00 1.28E+02 1.04E+02 8.20E+01 PASS 1.16E+02 4.58E+00 1.29E+02 1.04E+02 8.20E+01 PASS 1.16E+02 4.65E+00 1.29E+02 1.04E+02 8.20E+01 PASS 1.16E+02 4.31E+00 1.28E+02 1.04E+02 8.20E+01 PASS 1.16E+02 4.28E+00 1.28E+02 1.04E+02 8.20E+01 PASS An ISO 9001:2008 and DSCC Certified Company 361 TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased PSRR Match2 2 to 3 (dB) @ VS=+4.5V to +12V 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.176. Plot of PSRR Match2 2 to 3 (dB) @ VS=+4.5V to +12V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 362 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.176. Raw data for PSRR Match2 2 to 3 (dB) @ VS=+4.5V to +12V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). PSRR Match2 2 to 3 (dB) @ VS=+4.5V to +12V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 1.17E+02 1.08E+02 1.20E+02 1.37E+02 1.10E+02 1.08E+02 1.21E+02 1.07E+02 1.32E+02 1.12E+02 1.25E+02 1.09E+02 Total 20 1.17E+02 1.08E+02 1.21E+02 1.35E+02 1.10E+02 1.08E+02 1.21E+02 1.07E+02 1.33E+02 1.12E+02 1.25E+02 1.09E+02 Dose (krad(Si)) 50 100 1.17E+02 1.18E+02 1.08E+02 1.08E+02 1.21E+02 1.20E+02 1.37E+02 1.34E+02 1.10E+02 1.10E+02 1.08E+02 1.08E+02 1.21E+02 1.22E+02 1.07E+02 1.07E+02 1.32E+02 1.32E+02 1.12E+02 1.12E+02 1.24E+02 1.24E+02 1.09E+02 1.09E+02 200 1.18E+02 1.08E+02 1.20E+02 1.32E+02 1.10E+02 1.08E+02 1.24E+02 1.07E+02 1.29E+02 1.12E+02 1.24E+02 1.09E+02 1.19E+02 1.16E+01 1.50E+02 8.68E+01 1.18E+02 1.08E+01 1.48E+02 8.87E+01 1.19E+02 1.14E+01 1.50E+02 8.74E+01 1.18E+02 1.04E+01 1.47E+02 8.95E+01 1.18E+02 9.58E+00 1.44E+02 9.13E+01 1.16E+02 1.05E+01 1.45E+02 8.72E+01 8.20E+01 PASS 1.16E+02 1.08E+01 1.46E+02 8.66E+01 8.20E+01 PASS 1.16E+02 1.07E+01 1.45E+02 8.70E+01 8.20E+01 PASS 1.16E+02 1.06E+01 1.45E+02 8.72E+01 8.20E+01 PASS 1.16E+02 1.00E+01 1.44E+02 8.88E+01 8.20E+01 PASS An ISO 9001:2008 and DSCC Certified Company 363 TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased +Short-Circuit Current2 1 (A) @ VS=+5V 0.00E+00 -5.00E-03 -1.00E-02 -1.50E-02 -2.00E-02 -2.50E-02 -3.00E-02 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.177. Plot of +Short-Circuit Current2 1 (A) @ VS=+5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 364 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.177. Raw data for +Short-Circuit Current2 1 (A) @ VS=+5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Short-Circuit Current2 1 (A) @ VS=+5V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MAX Status 0 -2.49E-02 -2.68E-02 -2.69E-02 -2.42E-02 -2.70E-02 -2.63E-02 -2.57E-02 -2.54E-02 -2.61E-02 -2.56E-02 -2.67E-02 -2.80E-02 Total 20 -2.45E-02 -2.63E-02 -2.65E-02 -2.38E-02 -2.68E-02 -2.61E-02 -2.55E-02 -2.52E-02 -2.59E-02 -2.54E-02 -2.67E-02 -2.80E-02 Dose (krad(Si)) 50 100 -2.42E-02 -2.37E-02 -2.60E-02 -2.54E-02 -2.62E-02 -2.56E-02 -2.36E-02 -2.32E-02 -2.63E-02 -2.59E-02 -2.58E-02 -2.55E-02 -2.53E-02 -2.50E-02 -2.50E-02 -2.47E-02 -2.56E-02 -2.54E-02 -2.52E-02 -2.49E-02 -2.67E-02 -2.67E-02 -2.80E-02 -2.80E-02 200 -2.33E-02 -2.50E-02 -2.51E-02 -2.28E-02 -2.55E-02 -2.51E-02 -2.46E-02 -2.43E-02 -2.50E-02 -2.45E-02 -2.67E-02 -2.80E-02 -2.60E-02 -2.56E-02 -2.53E-02 -2.47E-02 -2.43E-02 1.30E-03 1.33E-03 1.29E-03 1.22E-03 1.23E-03 -2.24E-02 -2.19E-02 -2.17E-02 -2.14E-02 -2.10E-02 -2.95E-02 -2.93E-02 -2.88E-02 -2.81E-02 -2.77E-02 -2.58E-02 3.59E-04 -2.48E-02 -2.68E-02 -1.25E-02 PASS -2.56E-02 3.58E-04 -2.46E-02 -2.66E-02 -8.00E-03 PASS -2.54E-02 3.54E-04 -2.44E-02 -2.63E-02 -8.00E-03 PASS An ISO 9001:2008 and DSCC Certified Company 365 -2.51E-02 3.57E-04 -2.41E-02 -2.61E-02 -8.00E-03 PASS -2.47E-02 3.31E-04 -2.38E-02 -2.56E-02 -8.00E-03 PASS TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased +Short-Circuit Current2 2 (A) @ VS=+5V 0.00E+00 -5.00E-03 -1.00E-02 -1.50E-02 -2.00E-02 -2.50E-02 -3.00E-02 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.178. Plot of +Short-Circuit Current2 2 (A) @ VS=+5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 366 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.178. Raw data for +Short-Circuit Current2 2 (A) @ VS=+5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Short-Circuit Current2 2 (A) @ VS=+5V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MAX Status 0 -2.54E-02 -2.60E-02 -2.66E-02 -2.74E-02 -2.79E-02 -2.65E-02 -2.57E-02 -2.73E-02 -2.53E-02 -2.56E-02 -2.81E-02 -2.78E-02 Total 20 -2.50E-02 -2.56E-02 -2.62E-02 -2.70E-02 -2.76E-02 -2.63E-02 -2.55E-02 -2.71E-02 -2.52E-02 -2.54E-02 -2.81E-02 -2.78E-02 Dose (krad(Si)) 50 100 -2.47E-02 -2.43E-02 -2.52E-02 -2.46E-02 -2.58E-02 -2.54E-02 -2.66E-02 -2.60E-02 -2.71E-02 -2.66E-02 -2.60E-02 -2.57E-02 -2.53E-02 -2.50E-02 -2.68E-02 -2.65E-02 -2.49E-02 -2.47E-02 -2.52E-02 -2.49E-02 -2.80E-02 -2.80E-02 -2.78E-02 -2.78E-02 200 -2.38E-02 -2.42E-02 -2.49E-02 -2.54E-02 -2.58E-02 -2.53E-02 -2.46E-02 -2.61E-02 -2.43E-02 -2.44E-02 -2.80E-02 -2.77E-02 -2.66E-02 -2.63E-02 -2.59E-02 -2.53E-02 -2.48E-02 1.02E-03 1.06E-03 9.75E-04 9.60E-04 8.48E-04 -2.39E-02 -2.34E-02 -2.32E-02 -2.27E-02 -2.25E-02 -2.94E-02 -2.92E-02 -2.86E-02 -2.80E-02 -2.71E-02 -2.61E-02 7.90E-04 -2.39E-02 -2.82E-02 -1.25E-02 PASS -2.59E-02 7.75E-04 -2.38E-02 -2.80E-02 -8.00E-03 PASS -2.56E-02 7.65E-04 -2.35E-02 -2.77E-02 -8.00E-03 PASS An ISO 9001:2008 and DSCC Certified Company 367 -2.53E-02 7.59E-04 -2.33E-02 -2.74E-02 -8.00E-03 PASS -2.49E-02 7.39E-04 -2.29E-02 -2.70E-02 -8.00E-03 PASS TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased +Short-Circuit Current2 3 (A) @ VS=+5V 0.00E+00 -5.00E-03 -1.00E-02 -1.50E-02 -2.00E-02 -2.50E-02 -3.00E-02 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.179. Plot of +Short-Circuit Current2 3 (A) @ VS=+5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 368 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.179. Raw data for +Short-Circuit Current2 3 (A) @ VS=+5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Short-Circuit Current2 3 (A) @ VS=+5V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MAX Status 0 -2.53E-02 -2.59E-02 -2.66E-02 -2.74E-02 -2.77E-02 -2.65E-02 -2.54E-02 -2.73E-02 -2.54E-02 -2.57E-02 -2.78E-02 -2.74E-02 Total 20 -2.49E-02 -2.55E-02 -2.62E-02 -2.69E-02 -2.75E-02 -2.63E-02 -2.52E-02 -2.70E-02 -2.52E-02 -2.55E-02 -2.78E-02 -2.74E-02 Dose (krad(Si)) 50 100 -2.46E-02 -2.42E-02 -2.51E-02 -2.44E-02 -2.58E-02 -2.54E-02 -2.65E-02 -2.60E-02 -2.70E-02 -2.65E-02 -2.61E-02 -2.58E-02 -2.50E-02 -2.47E-02 -2.68E-02 -2.65E-02 -2.50E-02 -2.47E-02 -2.53E-02 -2.50E-02 -2.78E-02 -2.78E-02 -2.74E-02 -2.74E-02 200 -2.37E-02 -2.40E-02 -2.49E-02 -2.54E-02 -2.58E-02 -2.53E-02 -2.43E-02 -2.61E-02 -2.43E-02 -2.46E-02 -2.78E-02 -2.74E-02 -2.66E-02 -2.62E-02 -2.58E-02 -2.53E-02 -2.48E-02 1.02E-03 1.06E-03 9.88E-04 9.94E-04 8.98E-04 -2.38E-02 -2.33E-02 -2.31E-02 -2.25E-02 -2.23E-02 -2.94E-02 -2.91E-02 -2.85E-02 -2.80E-02 -2.72E-02 -2.61E-02 8.10E-04 -2.38E-02 -2.83E-02 -1.25E-02 PASS -2.59E-02 7.94E-04 -2.37E-02 -2.80E-02 -8.00E-03 PASS -2.56E-02 7.85E-04 -2.35E-02 -2.78E-02 -8.00E-03 PASS An ISO 9001:2008 and DSCC Certified Company 369 -2.53E-02 7.74E-04 -2.32E-02 -2.74E-02 -8.00E-03 PASS -2.49E-02 7.59E-04 -2.28E-02 -2.70E-02 -8.00E-03 PASS TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased +Short-Circuit Current2 4 (A) @ VS=+5V 0.00E+00 -5.00E-03 -1.00E-02 -1.50E-02 -2.00E-02 -2.50E-02 -3.00E-02 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.180. Plot of +Short-Circuit Current2 4 (A) @ VS=+5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 370 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.180. Raw data for +Short-Circuit Current2 4 (A) @ VS=+5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Short-Circuit Current2 4 (A) @ VS=+5V Device 519 520 521 522 524 536 537 538 539 542 543 544 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MAX Status 0 -2.46E-02 -2.66E-02 -2.69E-02 -2.42E-02 -2.70E-02 -2.61E-02 -2.60E-02 -2.53E-02 -2.60E-02 -2.58E-02 -2.69E-02 -2.80E-02 Total 20 -2.43E-02 -2.62E-02 -2.64E-02 -2.38E-02 -2.68E-02 -2.59E-02 -2.58E-02 -2.51E-02 -2.58E-02 -2.56E-02 -2.69E-02 -2.80E-02 Dose (krad(Si)) 50 100 -2.39E-02 -2.35E-02 -2.58E-02 -2.53E-02 -2.61E-02 -2.55E-02 -2.35E-02 -2.31E-02 -2.64E-02 -2.58E-02 -2.56E-02 -2.53E-02 -2.55E-02 -2.53E-02 -2.48E-02 -2.45E-02 -2.56E-02 -2.53E-02 -2.53E-02 -2.50E-02 -2.69E-02 -2.69E-02 -2.80E-02 -2.80E-02 200 -2.30E-02 -2.49E-02 -2.50E-02 -2.27E-02 -2.54E-02 -2.48E-02 -2.49E-02 -2.41E-02 -2.49E-02 -2.46E-02 -2.69E-02 -2.80E-02 -2.59E-02 -2.55E-02 -2.51E-02 -2.47E-02 -2.42E-02 1.33E-03 1.37E-03 1.33E-03 1.26E-03 1.26E-03 -2.22E-02 -2.18E-02 -2.15E-02 -2.12E-02 -2.07E-02 -2.95E-02 -2.93E-02 -2.88E-02 -2.81E-02 -2.77E-02 -2.58E-02 3.26E-04 -2.49E-02 -2.67E-02 -1.25E-02 PASS -2.56E-02 3.32E-04 -2.47E-02 -2.65E-02 -8.00E-03 PASS -2.54E-02 3.28E-04 -2.45E-02 -2.63E-02 -8.00E-03 PASS An ISO 9001:2008 and DSCC Certified Company 371 -2.51E-02 3.33E-04 -2.42E-02 -2.60E-02 -8.00E-03 PASS -2.47E-02 3.22E-04 -2.38E-02 -2.55E-02 -8.00E-03 PASS TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased -Short-Circuit Current2 1 (A) @ VS=+5V 6.00E-02 5.00E-02 4.00E-02 3.00E-02 2.00E-02 1.00E-02 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.181. Plot of -Short-Circuit Current2 1 (A) @ VS=+5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 372 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.181. Raw data for -Short-Circuit Current2 1 (A) @ VS=+5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) -Short-Circuit Current2 1 (A) @ VS=+5V Device 0 20 50 100 200 519 4.76E-02 4.74E-02 4.72E-02 4.73E-02 4.74E-02 520 4.92E-02 4.91E-02 4.91E-02 4.91E-02 4.89E-02 521 4.96E-02 4.96E-02 4.96E-02 4.96E-02 4.95E-02 522 4.74E-02 4.76E-02 4.75E-02 4.75E-02 4.72E-02 524 4.88E-02 4.91E-02 4.90E-02 4.89E-02 4.87E-02 536 4.82E-02 4.85E-02 4.85E-02 4.83E-02 4.82E-02 537 4.89E-02 4.91E-02 4.91E-02 4.89E-02 4.87E-02 538 4.82E-02 4.83E-02 4.82E-02 4.81E-02 4.78E-02 539 4.79E-02 4.82E-02 4.81E-02 4.79E-02 4.77E-02 542 4.85E-02 4.88E-02 4.88E-02 4.87E-02 4.83E-02 543 5.02E-02 5.08E-02 5.08E-02 5.08E-02 5.08E-02 544 5.16E-02 5.19E-02 5.19E-02 5.19E-02 5.18E-02 Biased Statistics Average Biased 4.85E-02 4.86E-02 4.85E-02 4.85E-02 4.83E-02 Std Dev Biased 9.96E-04 1.00E-03 1.08E-03 1.04E-03 1.02E-03 Ps90%/90% (+KTL) Biased 5.12E-02 5.13E-02 5.15E-02 5.13E-02 5.11E-02 Ps90%/90% (-KTL) Biased 4.58E-02 4.58E-02 4.55E-02 4.56E-02 4.55E-02 Un-Biased Statistics Average Un-Biased 4.83E-02 4.86E-02 4.85E-02 4.84E-02 4.81E-02 Std Dev Un-Biased 3.78E-04 3.90E-04 4.36E-04 4.07E-04 3.91E-04 Ps90%/90% (+KTL) Un-Biased 4.94E-02 4.97E-02 4.97E-02 4.95E-02 4.92E-02 Ps90%/90% (-KTL) Un-Biased 4.73E-02 4.75E-02 4.74E-02 4.73E-02 4.70E-02 Specification MIN 1.25E-02 8.00E-03 8.00E-03 8.00E-03 8.00E-03 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 373 TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased -Short-Circuit Current2 2 (A) @ VS=+5V 6.00E-02 5.00E-02 4.00E-02 3.00E-02 2.00E-02 1.00E-02 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.182. Plot of -Short-Circuit Current2 2 (A) @ VS=+5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 374 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.182. Raw data for -Short-Circuit Current2 2 (A) @ VS=+5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) -Short-Circuit Current2 2 (A) @ VS=+5V Device 0 20 50 100 200 519 4.77E-02 4.76E-02 4.73E-02 4.74E-02 4.74E-02 520 4.81E-02 4.80E-02 4.79E-02 4.79E-02 4.77E-02 521 4.95E-02 4.95E-02 4.95E-02 4.94E-02 4.93E-02 522 5.04E-02 5.07E-02 5.06E-02 5.06E-02 5.03E-02 524 4.93E-02 4.96E-02 4.95E-02 4.94E-02 4.91E-02 536 4.78E-02 4.82E-02 4.82E-02 4.79E-02 4.78E-02 537 4.79E-02 4.82E-02 4.81E-02 4.79E-02 4.77E-02 538 5.00E-02 5.02E-02 5.01E-02 5.00E-02 4.98E-02 539 4.78E-02 4.80E-02 4.79E-02 4.78E-02 4.75E-02 542 4.82E-02 4.84E-02 4.84E-02 4.83E-02 4.79E-02 543 4.99E-02 5.04E-02 5.05E-02 5.05E-02 5.04E-02 544 5.07E-02 5.10E-02 5.11E-02 5.11E-02 5.10E-02 Biased Statistics Average Biased 4.90E-02 4.91E-02 4.90E-02 4.89E-02 4.88E-02 Std Dev Biased 1.09E-03 1.29E-03 1.32E-03 1.29E-03 1.17E-03 Ps90%/90% (+KTL) Biased 5.20E-02 5.26E-02 5.26E-02 5.25E-02 5.20E-02 Ps90%/90% (-KTL) Biased 4.60E-02 4.56E-02 4.53E-02 4.54E-02 4.55E-02 Un-Biased Statistics Average Un-Biased 4.83E-02 4.86E-02 4.85E-02 4.84E-02 4.82E-02 Std Dev Un-Biased 9.38E-04 9.19E-04 8.92E-04 9.12E-04 9.06E-04 Ps90%/90% (+KTL) Un-Biased 5.09E-02 5.11E-02 5.10E-02 5.09E-02 5.06E-02 Ps90%/90% (-KTL) Un-Biased 4.58E-02 4.61E-02 4.61E-02 4.59E-02 4.57E-02 Specification MIN 1.25E-02 8.00E-03 1.25E-02 1.25E-02 1.25E-02 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 375 TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased -Short-Circuit Current2 3 (A) @ VS=+5V 6.00E-02 5.00E-02 4.00E-02 3.00E-02 2.00E-02 1.00E-02 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.183. Plot of -Short-Circuit Current2 3 (A) @ VS=+5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 376 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.183. Raw data for -Short-Circuit Current2 3 (A) @ VS=+5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) -Short-Circuit Current2 3 (A) @ VS=+5V Device 0 20 50 100 200 519 4.82E-02 4.81E-02 4.78E-02 4.78E-02 4.79E-02 520 4.87E-02 4.87E-02 4.87E-02 4.87E-02 4.84E-02 521 5.02E-02 5.03E-02 5.02E-02 5.01E-02 5.00E-02 522 5.13E-02 5.16E-02 5.15E-02 5.15E-02 5.11E-02 524 5.00E-02 5.05E-02 5.03E-02 5.02E-02 4.99E-02 536 4.85E-02 4.88E-02 4.88E-02 4.87E-02 4.85E-02 537 4.88E-02 4.90E-02 4.90E-02 4.88E-02 4.85E-02 538 5.07E-02 5.10E-02 5.09E-02 5.07E-02 5.05E-02 539 4.84E-02 4.87E-02 4.85E-02 4.84E-02 4.82E-02 542 4.89E-02 4.91E-02 4.91E-02 4.90E-02 4.87E-02 543 5.05E-02 5.11E-02 5.11E-02 5.12E-02 5.11E-02 544 5.13E-02 5.17E-02 5.17E-02 5.17E-02 5.16E-02 Biased Statistics Average Biased 4.97E-02 4.98E-02 4.97E-02 4.96E-02 4.94E-02 Std Dev Biased 1.27E-03 1.43E-03 1.44E-03 1.43E-03 1.29E-03 Ps90%/90% (+KTL) Biased 5.32E-02 5.38E-02 5.36E-02 5.36E-02 5.30E-02 Ps90%/90% (-KTL) Biased 4.62E-02 4.59E-02 4.57E-02 4.57E-02 4.59E-02 Un-Biased Statistics Average Un-Biased 4.91E-02 4.93E-02 4.93E-02 4.91E-02 4.89E-02 Std Dev Un-Biased 9.35E-04 9.41E-04 9.25E-04 9.25E-04 9.14E-04 Ps90%/90% (+KTL) Un-Biased 5.16E-02 5.19E-02 5.18E-02 5.17E-02 5.14E-02 Ps90%/90% (-KTL) Un-Biased 4.65E-02 4.67E-02 4.67E-02 4.66E-02 4.64E-02 Specification MIN 1.25E-02 8.00E-03 1.25E-02 1.25E-02 1.25E-02 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 377 TID Report 12-275 120517 R1.0 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased -Short-Circuit Current2 4 (A) @ VS=+5V 6.00E-02 5.00E-02 4.00E-02 3.00E-02 2.00E-02 1.00E-02 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.184. Plot of -Short-Circuit Current2 4 (A) @ VS=+5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 378 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.184. Raw data for -Short-Circuit Current2 4 (A) @ VS=+5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) -Short-Circuit Current2 4 (A) @ VS=+5V Device 0 20 50 100 200 519 4.71E-02 4.70E-02 4.67E-02 4.68E-02 4.69E-02 520 4.88E-02 4.87E-02 4.87E-02 4.87E-02 4.84E-02 521 4.92E-02 4.91E-02 4.91E-02 4.90E-02 4.90E-02 522 4.67E-02 4.69E-02 4.68E-02 4.68E-02 4.65E-02 524 4.82E-02 4.86E-02 4.84E-02 4.84E-02 4.81E-02 536 4.77E-02 4.79E-02 4.79E-02 4.78E-02 4.76E-02 537 4.81E-02 4.84E-02 4.84E-02 4.82E-02 4.79E-02 538 4.76E-02 4.77E-02 4.77E-02 4.75E-02 4.73E-02 539 4.77E-02 4.78E-02 4.78E-02 4.77E-02 4.74E-02 542 4.82E-02 4.84E-02 4.84E-02 4.82E-02 4.79E-02 543 4.95E-02 5.00E-02 5.01E-02 5.01E-02 5.00E-02 544 5.11E-02 5.13E-02 5.14E-02 5.13E-02 5.13E-02 Biased Statistics Average Biased 4.80E-02 4.81E-02 4.80E-02 4.79E-02 4.78E-02 Std Dev Biased 1.06E-03 1.04E-03 1.11E-03 1.06E-03 1.05E-03 Ps90%/90% (+KTL) Biased 5.09E-02 5.09E-02 5.10E-02 5.08E-02 5.07E-02 Ps90%/90% (-KTL) Biased 4.51E-02 4.52E-02 4.49E-02 4.50E-02 4.49E-02 Un-Biased Statistics Average Un-Biased 4.78E-02 4.81E-02 4.80E-02 4.79E-02 4.76E-02 Std Dev Un-Biased 2.56E-04 3.35E-04 3.16E-04 3.01E-04 2.96E-04 Ps90%/90% (+KTL) Un-Biased 4.85E-02 4.90E-02 4.89E-02 4.87E-02 4.84E-02 Ps90%/90% (-KTL) Un-Biased 4.71E-02 4.71E-02 4.72E-02 4.71E-02 4.68E-02 Specification MIN 1.25E-02 8.00E-03 1.25E-02 1.25E-02 1.25E-02 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 379 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 6.0. Summary / Conclusions The total ionizing dose testing described in this final report was performed using the facilities at Aeroflex RAD's Longmire Laboratories in Colorado Springs, CO. The high dose rate total ionizing dose (TID) source is a JLSA 81-24 irradiator modified to provide a panoramic exposure. The Co-60 rods are held in the base of the irradiator heavily shielded by lead, during the radiation exposures the rod is raised by an electronic timer/controller and the exposure is performed in air. The dose rate for this irradiator in this configuration ranges from <1rad(Si)/s to a maximum of approximately 120rad(Si)/s, determined by the distance from the source. The parametric data was obtained as "read and record" and all the raw data plus an attributes summary are contained in this report as well as in a separate Excel file. The attributes data contains the average, standard deviation and the average with the KTL values applied. The KTL value used in this work is 2.742 per MIL-HDBK-814 using one sided tolerance limits of 90/90 and a 5-piece sample size. The 90/90 KTL values were selected to match the statistical levels specified in the MIL-PRF-38535 sampling plan for the qualification of a radiation hardness assured (RHA) component. Note that the following criteria must be met for a device to pass the total ionizing dose test: following the radiation exposure each of the 5 pieces irradiated under electrical bias shall pass the specification value. The units irradiated without electrical bias and the KTL statistics are included in this report for reference only. If any of the 5 pieces irradiated under electrical bias exceed the device post radiation data sheet specification limits, then the lot could be logged as a failure. Based on this criterion the RH1499MW Quad Rail-to-Rail Input and Output Precision C-Load Op Amp (from the lot date code identified on the first page of this test report) PASSED the total ionizing dose test to the maximum tested dose level of 200krad(Si) with all parameters remaining within their datasheet specifications. An ISO 9001:2008 and DSCC Certified Company 380 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Appendix A: Photograph of a Sample Unit-Under-Test to Show Part Traceability An ISO 9001:2008 and DSCC Certified Company 381 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Appendix B: Radiation Bias Connections and Absolute Maximum Ratings TID Radiation Biased Conditions: Extracted from Linear Technology RH1499M datasheet, ID No 66-10-1499. Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Function OUT A -INPUT A +INPUT A V+ +INPUT B -INPUT B OUT B OUT C -INPUT C +INPUT C V+INPUT D -INPUT D OUT D Connection / Bias To Pin 2 via 5kΩ & 40pF, in Parallel To Pin 1 via 5kΩ & 40pF, in Parallel To 8V via 5kΩ Resistor To +15V using 0.1µF Decoupling To 8V via 5kΩ Resistor To Pin 7 via 5kΩ & 40pF, in Parallel To Pin 6 via 5kΩ & 40pF, in Parallel To Pin 9 via 5kΩ & 40pF, in Parallel To Pin 8 via 5kΩ & 40pF, in Parallel To 8V via 5kΩ Resistor To -15V using 0.1µF Decoupling To 8V via 10kΩ Resistor To Pin 14 via 5kΩ & 40pF, in Parallel To Pin 13 via 5kΩ & 40pF, in Parallel Figure B.1. Irradiation bias circuit. This figure was extracted from Linear Technology RH1499M datasheet, ID No 66-10-1499. An ISO 9001:2008 and DSCC Certified Company 382 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 TID Radiation Unbiased Conditions: Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Function OUT A -INPUT A +INPUT A V+ +INPUT B -INPUT B OUT B OUT C -INPUT C +INPUT C V+INPUT D -INPUT D OUT D Connection / Bias GND GND GND GND GND GND GND GND GND GND GND GND GND GND Figure B.2. W package drawing (for reference only). This figure was extracted from Linear Technology RH1499M datasheet, ID No 66-10-1499. Absolute Maximum Ratings: Parameter Total Supply Voltage (V+ to V-) Input Current Output Short-Circuit Duration Max Rating 36V ±10mA Continuous An ISO 9001:2008 and DSCC Certified Company 383 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Appendix C: Electrical Test Parameters and Conditions The expected ranges of values as well as the measurement conditions are taken from Linear Technology RH1499M datasheet. All electrical tests for this device are performed on one of Aeroflex RAD's LTS2020 Test Systems. The LTS2020 Test System is a programmable parametric tester that provides parameter measurements for a variety of digital, analog and mixed signal products including voltage regulators, voltage comparators, D to A and A to D converters. The LTS2020 Test System achieves accuracy and sensitivity through the use of software self-calibration and an internal relay matrix with separate family boards and custom personality adapter boards. The tester uses this relay matrix to connect the required test circuits, select the appropriate voltage / current sources and establish the needed measurement loops for all the tests performed. The measured parameters and test conditions are shown in Table C.1. A listing of the measurement precision/resolution for each parameter is shown in Table C.2. The precision/resolution values were obtained from test data or from the DAC resolution of the LTS-2020 for the particular test shown, whichever is greater. To generate the precision/resolution shown in Table C.2, one of the units-under-test was tested repetitively (a total of 10-times with re-insertion between tests) to obtain the average test value and standard deviation. Using this test data MIL-HDBK-814 90/90 KTL statistics were applied to the measured standard deviation to generate the final measurement range. This value encompasses the precision/resolution of all aspects of the test system, including the LTS2020 mainframe, family board, socket assembly and DUT board as well as insertion error. In some cases, the measurement resolution is limited by the internal DACs, which results in a measured standard deviation of zero. In these instances the precision/resolution will be reported back as the LSB of the DAC. Note that the testing and statistics used in this document are based on an “analysis of variables” technique, which relies on small sample sizes to qualify much larger lot sizes (see MIL-HDBK-814, p. 91 for a discussion of statistical treatments). Not all measured parameters are well suited to this approach due to inherent large variations. If necessary, larger samples sizes could be used to qualify these parameters using an “attributes” approach. An ISO 9001:2008 and DSCC Certified Company 384 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table C.1. Measured parameters and test conditions for the RH1499MW Quad Rail-to-Rail Input and Output Precision C-Load Op Amp. Parameter Symbol Test Conditions +Supply Current (A) +ICC15 VS=+/-15V -Supply Current (A) -IEE15 VS=+/-15V Input Offset Voltage1 (V) VOS1_14 VS=+/-15V, VCM=0V Input Offset Current1 (A) IOS1_14 VS=+/-15V, VCM=0V +Input Bias Current BIAS1 (A) +IBIAS1_14 VS=+/-15V, VCM=0V -Input Bias Current BIAS1 (A) -IBIAS1_14 VS=+/-15V, VCM=0V Input Offset Voltage2 (V) VOS2_14 VS=+/-15V, VCM=15V Input Offset Current2 (A) IOS2_14 VS=+/-15V, VCM=15V +Input Bias Current BIAS2 (A) +IBIAS2_14 VS=+/-15V, VCM=15V -Input Bias Current BIAS2 (A) -IBIAS2_14 VS=+/-15V, VCM=15V Input Offset Voltage3 (V) VOS3_14 VS=+/-15V, VCM=-15V Input Offset Current3 (A) IOS3_14 VS=+/-15V, VCM=-15V +Input Bias Current BIAS3 (A) +IBIAS3_14 VS=+/-15V, VCM=-15V -Input Bias Current BIAS3 (A) -IBIAS3_14 VS=+/-15V, VCM=-15V Output Voltage Swing High1 (V) +VOUT1_14 VS=+/-15V IL=0mA Output Voltage Swing High2 (V) +VOUT2_14 VS=+/-15V IL=1mA Output Voltage Swing High3 (V) +VOUT3_14 VS=+/-15V IL=10mA Output Voltage Swing Low1 (V) -VOUT1_14 VS=+/-15V IL=0mA Output Voltage Swing Low2 (V) -VOUT2_14 VS=+/-15V IL=1mA Output Voltage Swing Low3 (V) -VOUT3_14 VS=+/-15V IL=10mA Large Signal Voltage Gain1 (V/mV) AVOL1_14 VO=+/-14.5V, RL=10kΩ Large Signal Voltage Gain2 (V/mV) AVOL2_14 VO=+/-10V, RL=2kΩ Common Mode Rejection Ratio1 (dB) CMRR1_14 VS=+/-15V, VCM=+/-15V CMRR Match1 1 to 4 (dB) CMRR1 MATCH 1 to 4 VS=+/-15V, VCM=+/-15V CMRR Match1 2 to 3 (dB) CMRR1 MATCH 2 to 3 VS=+/-15V, VCM=+/-15V Power Supply Rejection Ratio1 (dB) PSRR1_14 VS=+/-2V to +/-16V PSRR Match1 1 to 4 (dB) PSRR1 MATCH 1 to 4 VS=+/-2V to +/-16V PSRR Match1 2 to 3 (dB) PSRR1 MATCH 2 to 3 VS=+/-2V to +/-16V An ISO 9001:2008 and DSCC Certified Company 385 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 +Short-Circuit Current1 (A) +ISC1_14 VS=+/-15V, VOUT=0V -Short-Circuit Current1 (A) -ISC1_14 VS=+/-15V, VOUT=0V +Supply Current (A) +ICC5 VS=+5V -Supply Current (A) -IEE5 VS=+5V Input Offset Voltage4 (V) VOS4_14 VS=+5V, VCM=0V Input Offset Current4 (A) IOS4_14 VS=+5V, VCM=0V +Input Bias Current BIAS4 (A) +IBIAS4_14 VS=+5V, VCM=0V -Input Bias Current BIAS4 (A) -IBIAS4_14 VS=+5V, VCM=0V Input Offset Voltage5 (V) VOS5_14 VS=+5V, VCM=5V Input Offset Current5 (A) IOS5_14 VS=+5V, VCM=5V +Input Bias Current BIAS5 (A) +IBIAS5_14 VS=+5V, VCM=5V -Input Bias Current BIAS5 (A) -IBIAS5_14 VS=+5V, VCM=5V Output Voltage Swing High4 (V) +VOUT4_14 VS=+5V IL=0mA Output Voltage Swing High5 (V) +VOUT5_14 VS=+5V IL=1mA Output Voltage Swing High6 (V) +VOUT6_14 VS=+5V IL=2.5mA Output Voltage Swing Low4 (V) -VOUT4_14 VS=+5V IL=0mA Output Voltage Swing Low5 (V) -VOUT5_14 VS=+5V IL=1mA Output Voltage Swing Low6 (V) -VOUT6_14 VS=+5V IL=2.5mA Large Signal Voltage Gain3 (V/mV) AVOL3_14 VO=75mV to 4.8V, RL=10kΩ Common Mode Rejection Ratio2 (dB) CMRR2_14 VS=+5V, VCM=0 to +5V CMRR Match2 1 to 4 (dB) CMRR2 MATCH 1 to 4 VS=+5V, VCM=0 to +5V CMRR Match2 2 to 3 (dB) CMRR2 MATCH 2 to 3 VS=+5V, VCM=0 to +5V Power Supply Rejection Ratio2 (dB) PSRR2_14 VS=+4.5V to +12V PSRR Match2 1 to 4 (dB) PSRR2 MATCH 1 to 4 VS=+4.5V to +12V PSRR Match2 2 to 3 (dB) PSRR2 MATCH 2 to 3 VS=+4.5V to +12V +Short-Circuit Current2 (A) +ISC2_14 VS=+5V -Short-Circuit Current2 (A) -ISC2_14 VS=+5V An ISO 9001:2008 and DSCC Certified Company 386 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table C.2. Measured parameters, pre-irradiation specifications and measurement precision for the RH1499MW Quad Rail-to-Rail Input and Output Precision C-Load Op Amp. Pre-Irradiation Specification Parameter MIN MAX +Supply Current (A) Measurement Precision/Resolution 1.00E-02 ±1.64E-04 -Supply Current (A) -1.00E-02 ±1.61E-04 Input Offset Voltage1 (V) -8.00E-04 8.00E-04 ±2.51E-05 Input Offset Current1 (A) -7.00E-08 7.00E-08 ±9.10E-10 +Input Bias Current BIAS1 (A) -7.15E-07 7.15E-07 ±1.22E-08 -Input Bias Current BIAS1 (A) -7.15E-07 7.15E-07 ±1.13E-08 Input Offset Voltage2 (V) -8.00E-04 8.00E-04 ±1.28E-05 Input Offset Current2 (A) -7.00E-08 7.00E-08 ±9.67E-10 +Input Bias Current BIAS2 (A) -7.15E-07 7.15E-07 ±7.21E-09 -Input Bias Current BIAS2 (A) -7.15E-07 7.15E-07 ±6.44E-09 Input Offset Voltage3 (V) -8.00E-04 8.00E-04 ±1.65E-05 Input Offset Current3 (A) -7.00E-08 7.00E-08 ±7.00E-10 +Input Bias Current BIAS3 (A) -7.15E-07 7.15E-07 ±1.01E-08 -Input Bias Current BIAS3 (A) -7.15E-07 7.15E-07 ±8.88E-09 Output Voltage Swing High1 (V) 1.00E-02 ±2.81E-04 Output Voltage Swing High2 (V) 1.50E-01 ±1.19E-03 Output Voltage Swing High3 (V) 8.00E-01 ±6.15E-03 Output Voltage Swing Low1 (V) 3.00E-02 ±5.56E-04 Output Voltage Swing Low2 (V) 1.00E-01 ±1.03E-03 Output Voltage Swing Low3 (V) 5.00E-01 ±3.44E-03 Large Signal Voltage Gain1 (V/mV) 1.00E+03 ±7.02E+02 Large Signal Voltage Gain2 (V/mV) 5.00E+01 ±1.02E+02 Common Mode Rejection Ratio1 (dB) 9.00E+01 3.00E+02 ±9.45E-02 CMRR Match1 1 to 4 (dB) 8.40E+01 3.00E+02 ±6.79E-02 CMRR Match1 2 to 3 (dB) 8.40E+01 3.00E+02 ±1.71E-01 Power Supply Rejection Ratio1 (dB) 9.00E+01 ±3.82E-01 PSRR Match1 1 to 4 (dB) 8.30E+01 ±1.35E-01 An ISO 9001:2008 and DSCC Certified Company 387 TID Report 12-275 120517 R1.0 PSRR Match1 2 to 3 (dB) 8.30E+01 ±8.96E-02 +Short-Circuit Current1 (A) -1.50E-02 -Short-Circuit Current1 (A) Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 1.50E-02 ±4.01E-04 ±6.44E-04 +Supply Current (A) 8.80E-03 ±8.67E-05 -Supply Current (A) -8.80E-03 ±8.59E-05 Input Offset Voltage4 (V) -8.00E-04 8.00E-04 ±1.49E-05 Input Offset Current4 (A) -6.50E-08 6.50E-08 ±5.28E-10 +Input Bias Current BIAS4 (A) -6.50E-07 6.50E-07 ±6.11E-09 -Input Bias Current BIAS4 (A) -6.50E-07 6.50E-07 ±6.24E-09 Input Offset Voltage5 (V) -8.00E-04 8.00E-04 ±8.65E-06 Input Offset Current5 (A) -6.50E-08 6.50E-08 ±5.15E-10 +Input Bias Current BIAS5 (A) -6.50E-07 6.50E-07 ±3.27E-09 -Input Bias Current BIAS5 (A) -6.50E-07 6.50E-07 ±2.91E-09 Output Voltage Swing High4 (V) 1.00E-02 ±2.53E-04 Output Voltage Swing High5 (V) 1.50E-01 ±8.19E-04 Output Voltage Swing High6 (V) 2.50E-01 ±1.46E-03 Output Voltage Swing Low4 (V) 3.00E-02 ±3.86E-04 Output Voltage Swing Low5 (V) 1.00E-01 ±4.14E-04 Output Voltage Swing Low6 (V) 2.00E-01 ±7.42E-04 Large Signal Voltage Gain3 (V/mV) 6.00E+02 ±5.72E+02 Common Mode Rejection Ratio2 (dB) 7.60E+01 ±1.49E-01 CMRR Match2 1 to 4 (dB) 7.50E+01 ±5.95E-02 CMRR Match2 2 to 3 (dB) 7.50E+01 ±3.80E-01 Power Supply Rejection Ratio2 (dB) 8.80E+01 ±4.26E+00 PSRR Match2 1 to 4 (dB) 8.20E+01 ±1.05E+00 PSRR Match2 2 to 3 (dB) 8.20E+01 ±6.39E-01 +Short-Circuit Current2 (A) -Short-Circuit Current2 (A) -1.25E-02 1.25E-02 ±4.02E-05 ±4.63E-04 An ISO 9001:2008 and DSCC Certified Company 388 TID Report 12-275 120517 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Appendix D: List of Figures Used in the Results Section (Section 5) 5.1. 5.2. 5.3. 5.4. 5.5. 5.6. 5.7. 5.8. 5.9. 5.10. 5.11. 5.12. 5.13. 5.14. 5.15. 5.16. 5.17. 5.18. 5.19. 5.20. 5.21. 5.22. 5.23. 5.24. 5.25. 5.26. 5.27. 5.28. 5.29. 5.30. 5.31. 5.32. 5.33. 5.34. 5.35. 5.36. 5.37. 5.38. 5.39. 5.40. +Supply Current (A) @ VS=+/-15V -Supply Current (A) @ VS=+/-15V Input Offset Voltage1 1 (V) @ VS=+/-15V, VCM=0V Input Offset Voltage1 2 (V) @ VS=+/-15V, VCM=0V Input Offset Voltage1 3 (V) @ VS=+/-15V, VCM=0V Input Offset Voltage1 4 (V) @ VS=+/-15V, VCM=0V Input Offset Current1 1 (A) @ VS=+/-15V, VCM=0V Input Offset Current1 2 (A) @ VS=+/-15V, VCM=0V Input Offset Current1 3 (A) @ VS=+/-15V, VCM=0V Input Offset Current1 4 (A) @ VS=+/-15V, VCM=0V +Input Bias Current BIAS1 1 (A) @ VS=+/-15V, VCM=0V +Input Bias Current BIAS1 2 (A) @ VS=+/-15V, VCM=0V +Input Bias Current BIAS1 3 (A) @ VS=+/-15V, VCM=0V +Input Bias Current BIAS1 4 (A) @ VS=+/-15V, VCM=0V -Input Bias Current BIAS1 1 (A) @ VS=+/-15V, VCM=0V -Input Bias Current BIAS1 2 (A) @ VS=+/-15V, VCM=0V -Input Bias Current BIAS1 3 (A) @ VS=+/-15V, VCM=0V -Input Bias Current BIAS1 4 (A) @ VS=+/-15V, VCM=0V Input Offset Voltage2 1 (V) @ VS=+/-15V, VCM=15V Input Offset Voltage2 2 (V) @ VS=+/-15V, VCM=15V Input Offset Voltage2 3 (V) @ VS=+/-15V, VCM=15V Input Offset Voltage2 4 (V) @ VS=+/-15V, VCM=15V Input Offset Current2 1 (A) @ VS=+/-15V, VCM=15V Input Offset Current2 2 (A) @ VS=+/-15V, VCM=15V Input Offset Current2 3 (A) @ VS=+/-15V, VCM=15V Input Offset Current2 4 (A) @ VS=+/-15V, VCM=15V +Input Bias Current BIAS2 1 (A) @ VS=+/-15V, VCM=15V +Input Bias Current BIAS2 2 (A) @ VS=+/-15V, VCM=15V +Input Bias Current BIAS2 3 (A) @ VS=+/-15V, VCM=15V +Input Bias Current BIAS2 4 (A) @ VS=+/-15V, VCM=15V -Input Bias Current BIAS2 1 (A) @ VS=+/-15V, VCM=15V -Input Bias Current BIAS2 2 (A) @ VS=+/-15V, VCM=15V -Input Bias Current BIAS2 3 (A) @ VS=+/-15V, VCM=15V -Input Bias Current BIAS2 4 (A) @ VS=+/-15V, VCM=15V Input Offset Voltage3 1 (V) @ VS=+/-15V, VCM=-15V Input Offset Voltage3 2 (V) @ VS=+/-15V, VCM=-15V Input Offset Voltage3 3 (V) @ VS=+/-15V, VCM=-15V Input Offset Voltage3 4 (V) @ VS=+/-15V, VCM=-15V Input Offset Current3 1 (A) @ VS=+/-15V, VCM=-15V Input Offset Current3 2 (A) @ VS=+/-15V, VCM=-15V An ISO 9001:2008 and DSCC Certified Company 389 TID Report 12-275 120517 R1.0 5.41. 5.42. 5.43. 5.44. 5.45. 5.46. 5.47. 5.48. 5.49. 5.50. 5.51. 5.52. 5.53. 5.54. 5.55. 5.56. 5.57. 5.58. 5.59. 5.60. 5.61. 5.62. 5.63. 5.64. 5.65. 5.66. 5.67. 5.68. 5.69. 5.70. 5.71. 5.72. 5.73. 5.74. 5.75. 5.76. 5.77. 5.78. 5.79. 5.80. 5.81. 5.82. Input Offset Current3 3 (A) @ VS=+/-15V, VCM=-15V Input Offset Current3 4 (A) @ VS=+/-15V, VCM=-15V +Input Bias Current BIAS3 1 (A) @ VS=+/-15V, VCM=-15V +Input Bias Current BIAS3 2 (A) @ VS=+/-15V, VCM=-15V +Input Bias Current BIAS3 3 (A) @ VS=+/-15V, VCM=-15V +Input Bias Current BIAS3 4 (A) @ VS=+/-15V, VCM=-15V -Input Bias Current BIAS3 1 (A) @ VS=+/-15V, VCM=-15V -Input Bias Current BIAS3 2 (A) @ VS=+/-15V, VCM=-15V -Input Bias Current BIAS3 3 (A) @ VS=+/-15V, VCM=-15V -Input Bias Current BIAS3 4 (A) @ VS=+/-15V, VCM=-15V Output Voltage Swing High1 1 (V) @ VS=+/-15V IL=0mA Output Voltage Swing High1 2 (V) @ VS=+/-15V IL=0mA Output Voltage Swing High1 3 (V) @ VS=+/-15V IL=0mA Output Voltage Swing High1 4 (V) @ VS=+/-15V IL=0mA Output Voltage Swing High2 1 (V) @ VS=+/-15V IL=1mA Output Voltage Swing High2 2 (V) @ VS=+/-15V IL=1mA Output Voltage Swing High2 3 (V) @ VS=+/-15V IL=1mA Output Voltage Swing High2 4 (V) @ VS=+/-15V IL=1mA Output Voltage Swing High3 1 (V) @ VS=+/-15V IL=10mA Output Voltage Swing High3 2 (V) @ VS=+/-15V IL=10mA Output Voltage Swing High3 3 (V) @ VS=+/-15V IL=10mA Output Voltage Swing High3 4 (V) @ VS=+/-15V IL=10mA Output Voltage Swing Low1 1 (V) @ VS=+/-15V IL=0mA Output Voltage Swing Low1 2 (V) @ VS=+/-15V IL=0mA Output Voltage Swing Low1 3 (V) @ VS=+/-15V IL=0mA Output Voltage Swing Low1 4 (V) @ VS=+/-15V IL=0mA Output Voltage Swing Low2 1 (V) @ VS=+/-15V IL=1mA Output Voltage Swing Low2 2 (V) @ VS=+/-15V IL=1mA Output Voltage Swing Low2 3 (V) @ VS=+/-15V IL=1mA Output Voltage Swing Low2 4 (V) @ VS=+/-15V IL=1mA Output Voltage Swing Low3 1 (V) @ VS=+/-15V IL=10mA Output Voltage Swing Low3 2 (V) @ VS=+/-15V IL=10mA Output Voltage Swing Low3 3 (V) @ VS=+/-15V IL=10mA Output Voltage Swing Low3 4 (V) @ VS=+/-15V IL=10mA Large Signal Voltage Gain1 1 (V/mV) @ VO=+/-14.5V, RL=10kΩ Large Signal Voltage Gain1 2 (V/mV) @ VO=+/-14.5V, RL=10kΩ Large Signal Voltage Gain1 3 (V/mV) @ VO=+/-14.5V, RL=10kΩ Large Signal Voltage Gain1 4 (V/mV) @ VO=+/-14.5V, RL=10kΩ Large Signal Voltage Gain2 1 (V/mV) @ VO=+/-10V, RL=2kΩ Large Signal Voltage Gain2 2 (V/mV) @ VO=+/-10V, RL=2kΩ Large Signal Voltage Gain2 3 (V/mV) @ VO=+/-10V, RL=2kΩ Large Signal Voltage Gain2 4 (V/mV) @ VO=+/-10V, RL=2kΩ An ISO 9001:2008 and DSCC Certified Company 390 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 TID Report 12-275 120517 R1.0 5.83. 5.84. 5.85. 5.86. 5.87. 5.88. 5.89. 5.90. 5.91. 5.92. 5.93. 5.94. 5.95. 5.96. 5.97. 5.98. 5.99. 5.100. 5.101. 5.102. 5.103. 5.104. 5.105. 5.106. 5.107. 5.108. 5.109. 5.110. 5.111. 5.112. 5.113. 5.114. 5.115. 5.116. 5.117. 5.118. 5.119. 5.120. 5.121. 5.122. 5.123. 5.124. Common Mode Rejection Ratio1 1 (dB) @ VS=+/-15V, VCM=+/-15V Common Mode Rejection Ratio1 2 (dB) @ VS=+/-15V, VCM=+/-15V Common Mode Rejection Ratio1 3 (dB) @ VS=+/-15V, VCM=+/-15V Common Mode Rejection Ratio1 4 (dB) @ VS=+/-15V, VCM=+/-15V CMRR Match1 1 to 4 (dB) @ VS=+/-15V, VCM=+/-15V CMRR Match1 2 to 3 (dB) @ VS=+/-15V, VCM=+/-15V Power Supply Rejection Ratio1 1 (dB) @ VS=+/-2V to +/-16V Power Supply Rejection Ratio1 2 (dB) @ VS=+/-2V to +/-16V Power Supply Rejection Ratio1 3 (dB) @ VS=+/-2V to +/-16V Power Supply Rejection Ratio1 4 (dB) @ VS=+/-2V to +/-16V PSRR Match1 1 to 4 (dB) @ VS=+/-2V to +/-16V PSRR Match1 2 to 3 (dB) @ VS=+/-2V to +/-16V +Short-Circuit Current1 1 (A) @ VS=+/-15V, VOUT=0V +Short-Circuit Current1 2 (A) @ VS=+/-15V, VOUT=0V +Short-Circuit Current1 3 (A) @ VS=+/-15V, VOUT=0V +Short-Circuit Current1 4 (A) @ VS=+/-15V, VOUT=0V -Short-Circuit Current1 1 (A) @ VS=+/-15V, VOUT=0V -Short-Circuit Current1 2 (A) @ VS=+/-15V, VOUT=0V -Short-Circuit Current1 3 (A) @ VS=+/-15V, VOUT=0V -Short-Circuit Current1 4 (A) @ VS=+/-15V, VOUT=0V +Supply Current (A) @ VS=+5V -Supply Current (A) @ VS=+5V Input Offset Voltage4 1 (V) @ VS=+5V, VCM=0V Input Offset Voltage4 2 (V) @ VS=+5V, VCM=0V Input Offset Voltage4 3 (V) @ VS=+5V, VCM=0V Input Offset Voltage4 4 (V) @ VS=+5V, VCM=0V Input Offset Current4 1 (A) @ VS=+5V, VCM=0V Input Offset Current4 2 (A) @ VS=+5V, VCM=0V Input Offset Current4 3 (A) @ VS=+5V, VCM=0V Input Offset Current4 4 (A) @ VS=+5V, VCM=0V +Input Bias Current BIAS4 1 (A) @ VS=+5V, VCM=0V +Input Bias Current BIAS4 2 (A) @ VS=+5V, VCM=0V +Input Bias Current BIAS4 3 (A) @ VS=+5V, VCM=0V +Input Bias Current BIAS4 4 (A) @ VS=+5V, VCM=0V -Input Bias Current BIAS4 1 (A) @ VS=+5V, VCM=0V -Input Bias Current BIAS4 2 (A) @ VS=+5V, VCM=0V -Input Bias Current BIAS4 3 (A) @ VS=+5V, VCM=0V -Input Bias Current BIAS4 4 (A) @ VS=+5V, VCM=0V Input Offset Voltage5 1 (V) @ VS=+5V, VCM=5V Input Offset Voltage5 2 (V) @ VS=+5V, VCM=5V Input Offset Voltage5 3 (V) @ VS=+5V, VCM=5V Input Offset Voltage5 4 (V) @ VS=+5V, VCM=5V An ISO 9001:2008 and DSCC Certified Company 391 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 TID Report 12-275 120517 R1.0 5.125. 5.126. 5.127. 5.128. 5.129. 5.130. 5.131. 5.132. 5.133. 5.134. 5.135. 5.136. 5.137. 5.138. 5.139. 5.140. 5.141. 5.142. 5.143. 5.144. 5.145. 5.146. 5.147. 5.148. 5.149. 5.150. 5.151. 5.152. 5.153. 5.154. 5.155. 5.156. 5.157. 5.158. 5.159. 5.160. 5.161. 5.162. 5.163. 5.164. 5.165. 5.166. Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Input Offset Current5 1 (A) @ VS=+5V, VCM=5V Input Offset Current5 2 (A) @ VS=+5V, VCM=5V Input Offset Current5 3 (A) @ VS=+5V, VCM=5V Input Offset Current5 4 (A) @ VS=+5V, VCM=5V +Input Bias Current BIAS5 1 (A) @ VS=+5V, VCM=5V +Input Bias Current BIAS5 2 (A) @ VS=+5V, VCM=5V +Input Bias Current BIAS5 3 (A) @ VS=+5V, VCM=5V +Input Bias Current BIAS5 4 (A) @ VS=+5V, VCM=5V -Input Bias Current BIAS5 1 (A) @ VS=+5V, VCM=5V -Input Bias Current BIAS5 2 (A) @ VS=+5V, VCM=5V -Input Bias Current BIAS5 3 (A) @ VS=+5V, VCM=5V -Input Bias Current BIAS5 4 (A) @ VS=+5V, VCM=5V Output Voltage Swing High4 1 (V) @ VS=+5V IL=0mA Output Voltage Swing High4 2 (V) @ VS=+5V IL=0mA Output Voltage Swing High4 3 (V) @ VS=+5V IL=0mA Output Voltage Swing High4 4 (V) @ VS=+5V IL=0mA Output Voltage Swing High5 1 (V) @ VS=+5V IL=1mA Output Voltage Swing High5 2 (V) @ VS=+5V IL=1mA Output Voltage Swing High5 3 (V) @ VS=+5V IL=1mA Output Voltage Swing High5 4 (V) @ VS=+5V IL=1mA Output Voltage Swing High6 1 (V) @ VS=+5V IL=2.5mA Output Voltage Swing High6 2 (V) @ VS=+5V IL=2.5mA Output Voltage Swing High6 3 (V) @ VS=+5V IL=2.5mA Output Voltage Swing High6 4 (V) @ VS=+5V IL=2.5mA Output Voltage Swing Low4 1 (V) @ VS=+5V IL=0mA Output Voltage Swing Low4 2 (V) @ VS=+5V IL=0mA Output Voltage Swing Low4 3 (V) @ VS=+5V IL=0mA Output Voltage Swing Low4 4 (V) @ VS=+5V IL=0mA Output Voltage Swing Low5 1 (V) @ VS=+5V IL=1mA Output Voltage Swing Low5 2 (V) @ VS=+5V IL=1mA Output Voltage Swing Low5 3 (V) @ VS=+5V IL=1mA Output Voltage Swing Low5 4 (V) @ VS=+5V IL=1mA Output Voltage Swing Low6 1 (V) @ VS=+5V IL=2.5mA Output Voltage Swing Low6 2 (V) @ VS=+5V IL=2.5mA Output Voltage Swing Low6 3 (V) @ VS=+5V IL=2.5mA Output Voltage Swing Low6 4 (V) @ VS=+5V IL=2.5mA Large Signal Voltage Gain3 1 (V/mV) @ VO=75mV to 4.8V, RL=10kΩ Large Signal Voltage Gain3 2 (V/mV) @ VO=75mV to 4.8V, RL=10kΩ Large Signal Voltage Gain3 3 (V/mV) @ VO=75mV to 4.8V, RL=10kΩ Large Signal Voltage Gain3 4 (V/mV) @ VO=75mV to 4.8V, RL=10kΩ Common Mode Rejection Ratio2 1 (dB) @ VS=+5V, VCM=0 to +5V Common Mode Rejection Ratio2 2 (dB) @ VS=+5V, VCM=0 to +5V An ISO 9001:2008 and DSCC Certified Company 392 TID Report 12-275 120517 R1.0 5.167. 5.168. 5.169. 5.170. 5.171. 5.172. 5.173. 5.174. 5.175. 5.176. 5.177. 5.178. 5.179. 5.180. 5.181. 5.182. 5.183. 5.184. Common Mode Rejection Ratio2 3 (dB) @ VS=+5V, VCM=0 to +5V Common Mode Rejection Ratio2 4 (dB) @ VS=+5V, VCM=0 to +5V CMRR Match2 1 to 4 (dB) @ VS=+5V, VCM=0 to +5V CMRR Match2 2 to 3 (dB) @ VS=+5V, VCM=0 to +5V Power Supply Rejection Ratio2 1 (dB) @ VS=+4.5V to +12V Power Supply Rejection Ratio2 2 (dB) @ VS=+4.5V to +12V Power Supply Rejection Ratio2 3 (dB) @ VS=+4.5V to +12V Power Supply Rejection Ratio2 4 (dB) @ VS=+4.5V to +12V PSRR Match2 1 to 4 (dB) @ VS=+4.5V to +12V PSRR Match2 2 to 3 (dB) @ VS=+4.5V to +12V +Short-Circuit Current2 1 (A) @ VS=+5V +Short-Circuit Current2 2 (A) @ VS=+5V +Short-Circuit Current2 3 (A) @ VS=+5V +Short-Circuit Current2 4 (A) @ VS=+5V -Short-Circuit Current2 1 (A) @ VS=+5V -Short-Circuit Current2 2 (A) @ VS=+5V -Short-Circuit Current2 3 (A) @ VS=+5V -Short-Circuit Current2 4 (A) @ VS=+5V An ISO 9001:2008 and DSCC Certified Company 393 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800