ETC VO4A486L

V03, V04 and V05 Series
2/2 and 3/2 Poppet Valves
Electrically Actuated
G1⁄8, G1⁄4, CNOMO and Interface
● Extensive range of power and orifice size options
● Removable coil
● Manifold rail for 1 to 20 valves
● Reduced installation height
● Exhaust diffuser supplied as standard
● Normally closed and normally open types
Technical Data
Ordering Information
Medium:
Compressed air, filtered, lubricated or non-lubricated.
Operation:
Poppet valve, directly actuated with spring return.
Mounting:
Through holes in sub-base, threaded on single station.
Port Size:
G1⁄8, G1⁄4 or 3mm (CNOMO and Interface)
Operating Pressure:
Up to 16 bar. See table overleaf.
Orifice Sizes:
1,0 mm, 1,5 mm, 2,0 mm, 2,5 mm and 3,0 mm.
See table overleaf.
Flow:
See details on page 5.4.042.03
Operating Temperature:
– 30°C* to + 90°C supply air
– 30°C* to + 50°C ambient
To order, quote model number as indicated in
the tables overleaf, e.g. V04X486L–B623A for
the 3/2 model with an interface base, a 2 mm
orifice and a 4,5 W, 24 V d.c. coil without plug.
Coils can also be supplied, quote reference
from table overleaf inserting the voltage code
where marked *.
* Consult our Technical Service for use below +2°C
Response Times:
8 – 15 ms
Materials:
Glass reinforced thermoplastic encapsulated coil, stainless iron
armature, stainless steel tube and spring, zinc alloy (G1⁄8 and
CNOMO) or brass (G1⁄4) or polyester (interface base), nitrile
rubber seals.
3
21
4/97
Our policy is one of continued research and development. We therefore reserve the right
to amend, without notice, the specifications given in this document.
21
2 11
2
N/ ** 5.4.042.01
V03, V04, V05 Series
General Information
V03
Symbol
2
12
Model
Type
Base
Orifice
(mm)
Maximum Operating
Pressure (bar)
Weight
(kg)
Coil Assembly
without terminal box
V03X286J–B613A
Normally Closed
Interface
1,0
10
0,20
V03X286A–Q1213
10
1
2
12
10
3
1
2
10
12
1
3
V03A286J–B613A
Normally Closed
G 1⁄8
1,0
10
0,24
V03X286A–Q1213
V03X486J–B613A
V03X486K–B613A
V03A486J–B613A
V03A486K–B613A
V03Y486J–B613A
V03Y486K–B613A
V03X386J–B613A
V03X386K–B613A
V03A386J–B613A
V03A386K–B613A
Normally Closed
Normally Closed
Normally Closed
Normally Closed
Normally Closed
Normally Closed
Normally Open
Normally Open
Normally Open
Normally Open
Interface
Interface
G 1⁄8
G 1⁄8
CNOMO
CNOMO
Interface
Interface
G 1⁄8
G 1⁄8
1,0
1,5
1,0
1,5
1,0
1,5
1,0
1,5
1,0
1,5
10
4
10
4
10
4
10
4
10
4
0,20
0,20
0,24
0,24
0,30
0,30
0,20
0,20
0,24
0,24
V03X286A–Q1213
V03X286A–Q1213
V03X286A–Q1213
V03X286A–Q1213
V03X286A–Q1213
V03X286A–Q1213
V03X286A–Q1213
V03X286A–Q1213
V03X286A–Q1213
V03X286A–Q1213
Model
Type
Base
V04X286K–B62*A
V04X286L–B62*A
V04X286M–B62*A
V04A286K–B62*A
V04A286L–B62*A
V04A286M–B62*A
V04B286L–B42*A
V04B286M–B42*A
V04B286N–B42*A
V04X486J–B62*A
V04X486K–B62*A
V04X486L–B62*A
V04X486M–B62*A
V04A486J–B62*A
V04A486K–B62*A
V04A486L–B62*A
V04A486M–B62*A
V04Y486K–B62*A
V04Y486L–B62*A
V04Y486M–B62*A
V04X386J–B62*A
V04X386K–B62*A
V04X386L–B62*A
V04X386M–B62*A
V04A386J–B62*A
V04A386K–B62*A
V04A386L–B62*A
V04A386M–B62*A
Normally Closed
Normally Closed
Normally Closed
Normally Closed
Normally Closed
Normally Closed
Normally Closed
Normally Closed
Normally Closed
Normally Closed
Normally Closed
Normally Closed
Normally Closed
Normally Closed
Normally Closed
Normally Closed
Normally Closed
Normally Closed
Normally Closed
Normally Closed
Normally Open
Normally Open
Normally Open
Normally Open
Normally Open
Normally Open
Normally Open
Normally Open
Interface
Interface
Interface
G 1⁄8
G 1⁄8
G 1⁄8
G 1⁄4
G 1⁄4
G 1⁄4
Interface
Interface
Interface
Interface
G 1⁄8
G 1⁄8
G 1⁄8
G 1⁄8
CNOMO
CNOMO
CNOMO
Interface
Interface
Interface
Interface
G 1⁄8
G 1⁄8
G 1⁄8
G 1⁄8
Orifice
(mm)
1,5
2,0
2,5
1,5
2,0
2,5
2,0
2,5
3,0
1,0
1,5
2,0
2,5
1,0
1,5
2,0
2,5
1,5
2,0
2,5
1,0
1,5
2,0
2,5
1,0
1,5
2,0
2,5
Maximum Operating
Pressure (bar)
16
16
14
16
16
14
16
14
7
16
13
10
4
16
16
13
4
13
10
4
16
13
10
4
16
13
10
4
Weight
(kg)
0,20
0,20
0,20
0,24
0,24
0,24
0,32
0,32
0,32
0,20
0,20
0,20
0,20
0,24
0,24
0,24
0,24
0,30
0,30
0,30
0,20
0,20
0,20
0,20
0,24
0,24
0,24
0,24
Coil Assembly
without terminal box
V04X286A–Q122*
V04X286A–Q122*
V04X286A–Q122*
V04X286A–Q122*
V04X286A–Q122*
V04X286A–Q122*
V04X286A–Q122*
V04X286A–Q122*
V04X286A–Q122*
V04X286A–Q122*
V04X286A–Q122*
V04X286A–Q122*
V04X286A–Q122*
V04X286A–Q122*
V04X286A–Q122*
V04X286A–Q122*
V04X286A–Q122*
V04X286A–Q122*
V04X286A–Q122*
V04X286A–Q122*
V04X286A–Q122*
V04X286A–Q122*
V04X286A–Q122*
V04X286A–Q122*
V04X286A–Q122*
V04X286A–Q122*
V04X286A–Q122*
V04X286A–Q122*
V04
Symbol
2
12
10
1
2
12
10
3
1
2
10
12
1
3
*Insert voltage code from Voltage Codes table page 5.4.042.03.
All models are available without manual override. Change 10th digit to 1 e.g. V03X486J–B11*A.
CNOMO versions are available with a push to operate spring return manual override. Change 10th digit to 3 e.g. V03X486J–B31*A.
Warning
These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can
exceed those listed under ‘Technical Data’.
Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not
within published specifications, consult Norgren.
Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to
consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or
damage to equipment in the event of such failure.
System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be
adequately provided.
System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these
products.
N/ ** 5.4.042.02
Our policy is one of continued research and development. We therefore reserve the right
to amend, without notice, the specifications given in this document.
4/97
V03, V04, V05 Series
V05
Symbol
2
12
10
1
2
12
10
3
1
2
10
12
1
3
Model
Type
Base
V05X286M–B63*A
V05A286M–B63*A
V05B286M–B43*A
V05B286N–B43*A
V05X486K–B63*A
V05X486L–B63*A
V05X486M–B63*A
V05A486K–B63*A
V05A486L–B63*A
V05A486M–B63*A
V05B486L–B43*A
V05B486M–B43*A
V05Y486K–B63*A
V05Y486L–B63*A
V05Y486M–B63*A
V05X386K–B63*A
V05X386L–B63*A
V05X386M–B63*A
V05A386K–B63*A
V05A386L–B63*A
V05A386M–B63*A
Normally Closed
Normally Closed
Normally Closed
Normally Closed
Normally Closed
Normally Closed
Normally Closed
Normally Closed
Normally Closed
Normally Closed
Normally Closed
Normally Closed
Normally Closed
Normally Closed
Normally Closed
Normally Open
Normally Open
Normally Open
Normally Open
Normally Open
Normally Open
Interface
G 1⁄8
G 1⁄4
G 1⁄4
Interface
Interface
Interface
G 1⁄8
G 1⁄8
G 1⁄8
G 1⁄4
G 1⁄4
CNOMO
CNOMO
CNOMO
Interface
Interface
Interface
G 1⁄8
G 1⁄8
G 1⁄8
Orifice
(mm)
2,5
2,5
2,5
3,0
1,5
2,0
2,5
1,5
2,0
2,5
2,0
2,5
1,5
2,0
2,5
1,5
2,0
2,5
1,5
2,0
2,5
Maximum Operating
Pressure (bar)
16
16
16
13
16
13
10
16
13
10
13
10
16
13
10
16
13
10
16
13
10
Weight
(kg)
0,20
0,24
0,32
0,32
0,20
0,20
0,20
0,24
0,24
0,24
0,24
0,24
0,30
0,30
0,30
0,20
0,20
0,20
0,24
0,24
0,24
Coil Assembly
without plug
V05X286A–Q123*
V05X286A–Q123*
V05X286A–Q123*
V05X286A–Q123*
V05X286A–Q123*
V05X286A–Q123*
V05X286A–Q123*
V05X286A–Q123*
V05X286A–Q123*
V05X286A–Q123*
V05X286A–Q123*
V05X286A–Q123*
V05X286A–Q123*
V05X286A–Q123*
V05X286A–Q123*
V05X286A–Q123*
V05X286A–Q123*
V05X286A–Q123*
V05X286A–Q123*
V05X286A–Q123*
V05X286A–Q123*
*Insert voltage code from Voltage Codes table page 5.4.042.03.
All models are available without manual override. Change 10th digit to 1 e.g. V03X486J–B11*A.
CNOMO versions are available with a push to operate spring return manual override. Change 10th digit to 3 e.g. V03X486J–B31*A.
Valve and Base Options
Family
V03
V04
V05
7mm Interface Mounted Valve
V03X
V04X
V05X
G1⁄8 Valve
V03A
V04A
V05A
G1⁄4 Valve
V03B
V04B
V05B
CNOMO Mounted Valve
V03Y
V04Y
V05Y
Fixed Length Manifold
M/P35598/†
M/P35598/†
M/P35598/†
*Insert Voltage Code from table below
* Voltage Codes
Manifold/Valve Assemblies
V03X∆86∆-H613A#
VO4X∆86∆-H62*A#
VO5X∆86∆-H63*A#
†Insert number of stations
Technical Details
Voltage
6 V d.c.
12 V d.c.
24 V d.c.
48 V d.c.
110 V d.c.
24 V 50/60 Hz
48 V 50/60 Hz
110 – 120 V 50/60 Hz
220 – 240 V 50/60 Hz
Voltage Tolerance:
Inrush/Hold
Codes
1
2
3
5
7
4
6
8
9
±10%
V03
VO4
VO5
Plug:
Manual Override
Protection Class:
d.c. 1,0 W
d.c. 4,5 W
a.c. 14/10 VA
d.c. 9,0 W
a.c. 27/20 VA
100% E.D.
A variety of plugs are available, see Section
7.7.001
Screwdriver operated, memory type, standard
IP 65 (DIN 40 050) with terminal box fitted
Note: The V03 models are only available with the 24 V d.c. coil.
Flow Characteristics
Inlet Orifice
∆mm
1
1,5
2
2,5
3,0
C
b
l/min
A
Cv
Kv
0,15
0,30
0,57
0,77
1,16
0,61
0,36
0,30
0,30
0,49
39,4
68,95
137,9
187,15
275,8
0,95
1,26
2,36
3,05
6,25
0,04
0,07
0,14
0,19
0,28
0,03
0,06
0,12
0,16
0,24
The above figures are based on valves mounted on a G1⁄8 base. They
are typical of all base styles as the orifice diameter is the limiting factor.
4/97
Our policy is one of continued research and development. We therefore reserve the right
to amend, without notice, the specifications given in this document.
N/ ** 5.4.042.03
V03, V04, V05 Series
V 0 ★ ★ ★ 8 6 ★ - B ★ ★ ★ ★
Model Codes
Family
VO3
VO4
VO5
Substitute
3
4
5
Plug
None
Standard, with Pg9 cable gland
Indicator, with Pg9 cable gland
Base Type
Interface
CNOMO
G1/8
G1/4
Substitute
X
Y
A
B
Voltage code
See Voltage Code table on page 3
Function
2/2 Normally closed
3/2 Normally open
3/2 Normally closed
Substitute
2
3
4
Power
1W (VO3 models only)
4,5W (VO4 models only)
9W (VO5 models only)
Substitute
1
2
3
Substitute
1
3*
4
6*
Solenoid operator
All Valves
8
Manual Operator
None
Push to operate spring return
Lever, memory type
Screwdriver, memory type
Spring return
All Valves
6
Integral design
All Valves
Inlet Orifice
1,0 mm (Interface, CNOMO)
1,5 mm (Interface, CNOMO, G1/8)
2,0 mm (Interface, CNOMO, G1/8, G1/4)
2,5 mm (Interface, CNOMO, G1/8, G1/4)
3,0 mm (G1/4)
Substitute
J
K
L
M
N
B
* Not available on G1⁄4
Note: This table should be used for identification purposes only and not
to build up model variants.
V03A, V04A and V05A Models
G1⁄8 Valves
V03X, V04X and V05X Models
Interface Mounted Valves
32
32
7
‘2’
24
‘1’ G1/8
2,4
24
24
32
3,3
7,5
32
6
M4
5
24
4,7
Substitute
A
B
G
2,7
7
‘2’ G1/8
9,3
7
‘1’
2,4
41
‘3’ G1/8
41
12,5
8
7
63,5
74
59,5
70
6
6
‘3’ G1/8
‘1’
G1/8
2
1,5
2
40
40
69
69
N/ ** 5.4.042.04
Our policy is one of continued research and development. We therefore reserve the right
to amend, without notice, the specifications given in this document.
4/97
V03, V04, V05 Series
V03Y, V04Y and V05Y Models
CNOMO Mounted Valves
V03B, V04B and V05B Models
G1⁄4 Valves
12,7
M4
12,7
21
M4
32
8
‘2’ G1/4
41
41
79
68,5
‘1’ G1/4
7,5
‘2’
17
19
12
21
7,5
72,5
83
6
‘3’ G1/8
2
36
32
33
50
‘1’
41
40
70
69
Fixed Length Manifold
61**
61**
61**
4
M/P35598/*
Weight = N x 0,041 Kg
G1⁄8
N = Number of stations
* indicates the number of stations (1 – 20)
4
4
24
**
M5 x 0,8
**
‘2’
16
‘2’
‘2’
33
33
‘2’ G1/8 x 9,5
33 x (N –1) + 32
N = Number of stations
** Two additional holes with five or more stations
4/97
Our policy is one of continued research and development. We therefore reserve the right
to amend, without notice, the specifications given in this document.
N/ ** 5.4.042.05
V03, V04, V05 Series
Manifold/Valve Assemblies
61**
Interface mounted valves can be supplied
pre-assembled on manifolds.
61**
4
Select the basic valve required and quote the
associated manifold/valve assembly model using
the table below.
4
"A"
Basic Valve Model
‘1’
24
**
**
V03
G1/8
M5
View on arrow "A"
V04
‘3’ G1/8
69
6
41
8,6
16
‘2’
‘2’
33
33
‘2’ G1/8
33 x (N* –1) + 32
13,2
17,2
‘2’
95,7
59,5
V05
V03X286J–B613A
V03X486J–B613A
V03X486K–B613A
VO4X286K–B62*A
VO4X286L–B62*A
VO4X286M–B62*A
VO4X486J–B62*A
VO4X486K–B62*A
VO4X486L–B62*A
VO4X486M–B62*A
VO5X286M–B61*A
VO5X486K–B61*A
VO5X486L–B61*A
Manifold/Valve Assembly
Model
V03X286J–H613A#
V03X486J–H613A#
V03X486K–H613A#
VO4X286K–H62*A#
VO4X286L–H62*A#
VO4X286M–H62*A#
VO4X486J–H62*A#
VO4X486K–H62*A#
VO4X486L–H62*A#
VO4X486M–H62*A#
VO5X286M–H63*A#
VO5X486K–H63*A#
VO5X486L–H63*A#
# Insert number of stations (1 - 20 stations)
1 = 1 station
2 = 2 station
A = 10 station
B = 11 station
K = 19 Station
L = 20 station
* Insert Voltage Code from page 5.4.042.03
32,7
Options and Accessories
Light Emitting Gaskets
Voltage Range
Model Number
12 – 24 V a.c./d.c.
M/P40861
0,25 W
110 – 120 V a.c./d.c.
M/P40880
0,25 W
220 – 240 V a.c./d.c.
M/P40862
0,25 W
N/ ** 5.4.042.06
Power consumption
Our policy is one of continued research and development. We therefore reserve the right
to amend, without notice, the specifications given in this document.
4/97