Datasheet

CENTIGRID®
SURFACE MOUNT
COMMERCIAL RELAYS
SERIES
S114
DPDT
SERIES
DESIGNATION
RELAY TYPE
S114
DPDT basic relay
S114D
DPDT relay with internal diode for coil transient suppression
DPDT relay with internal diodes for coil transient suppression and polarity
reversal protection
S114DD
INTERNAL CONSTRUCTION
DESCRIPTION
UNI-FRAME
The Series S114 Surface Mount Centigrid® Relay is an ultraminiature,
hermetically sealed, armature relay. The low profile height (.360") and .100"
ARMATURE
lead spacing make it ideal for applications where extreme packaging density
UPPER
STATIONARY
CONTACT
and/or close PC board spacing are required. The specially formed leads are
MOVING
CONTACT
LOWER
STATIONARY
CONTACT
pre-tinned to make the relays ideal for most types of surface mount solder
CENTIGRID® AND TO-5
reflow processes.
The basic design and internal construction are identical to the Series 114
Centigrid® relays, and are capable of meeting Teledyne Relays’ T2R®
requirements. The following unique construction features and manufacturing
techniques provide overall high reliability and excellent resistance to
ENVIRONMENTAL AND
PHYSICAL SPECIFICATIONS
–65°C to +125°C
Temperature Storage
(Ambient)
Operating –55°C to +85°C
environmental extremes:
• All welded construction.
• Unique uni-frame design providing high magnetic efficiency and mechanical
Vibration
(General Note 1)
30 g’s to 3000 Hz
Shock
(General Note 1)
75 g’s,
6 msec, half-sine
• High force/mass ratios for resistance to shock and vibration.
Acceleration
50 g’s
• Advanced cleaning techniques provide maximum assurance of internal
Enclosure
Hermetically sealed
Weight
0.07 oz. (1.9g) max.
Reflow Temperature
260°C max. temp.
1 min. max.
©2003 TELEDYNE RELAYS
rigidity.
cleanliness.
• Precious metal alloy contact material with gold plating assures excellent
high current and dry circuit switching capabilities.
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
www.teledynerelays.com
S114 Page 80
S114/1203/Q1
SERIES S114
GENERAL ELECTRICAL SPECIFICATIONS (–65°C to +125°C unless otherwise noted) (Notes 2 & 3)
Contact Arrangement
Rated Duty
Contact Resistance
2 Form C (DPDT)
Continuous
0.1 ohm max. before life; 0.2 ohm max. after life at 1A/28Vdc (measured 1/8" from header along lead)
Contact Load Ratings (DC)
(See Fig. 3 for other DC
resistive voltage/current ratings)
Resistive:
Inductive:
Lamp:
Low Level:
1 Amp/28Vdc
200 mA/28Vdc (320 mH)
100 mA/28Vdc
10 to 50 µA/10 to 50mV
Resistive:
250 mA/115Vac, 60 and 400 Hz (Case undergrounded)
100 mA/115Vac, 60 and 400 Hz (Case grounded)
Contact Load Ratings (AC)
Contact Life Ratings
10,000,000 cycles (typical) at low level
1,000,000 cycles (typical) at 0.5A/28Vdc resistive
100,000 cycles min. at all other loads specified above
Contact Overload Rating
Contact Carry Rating
Coil Operating Power
Operate Time
Release Time
Contact Bounce
Intercontact Capacitance
Insulation Resistance
Dielectric Strength
Negative Coil Transient (Vdc)
Diode P.I.V. (Vdc)
2A/28Vdc Resistive (100 cycles min.)
Contact factory
450 milliwatts typical at nominal rated voltage at 25°C
2.0 msec max. at nominal rated coil voltage
S114 Series: 1.5 msec max. S114D, S114DD Series: 4.0 msec max.
1.5 msec max.
0.4 pf typical
10,000 megohms min. between mutually isolated terminals
Atmospheric pressure: 500 Vrms/60Hz
70,000 ft.: 125 Vrms/60Hz
S114D, S114DD
1.0 max
S114D, S114DD
100 min.
DETAILED ELECTRICAL SPECIFICATIONS (–65°C to +125°C unless otherwise noted) (Note 3)
S114-5
S114-6
S114-9
S114-12
S114-18
S114-26
S114D-5
S114D-6
S114D-9 S114D-12 S114D-18 S114D-26
S114DD-5 S114DD-6 S114DD-9 S114DD-12 S114DD-18 S114DD-26
BASE PART
NUMBERS
(See Note 10 for full P/N example)
Coil Resistance
(Ohms ±10% @25°C)
Coil Current (mAdc @25°C)
(S114DD Series only)
Pick-up Voltage (Vdc, Max.)
Drop-out Voltage (Vdc)
5.0
5.8
50
39
93.2
128.2
3.5
4.0
0.14
2.3
0.6
2.8
6.0
8.0
98
78
57.8
74.8
4.5
5.0
0.18
3.2
0.7
3.4
9.0
12.0
220
220
33.0
42.9
6.8
7.8
0.35
4.9
0.8
5.3
12.0
16.0
390
390
25.6
32.8
9.0
10.0
0.41
6.5
0.9
6.5
18.0
24.0
880
880
17.5
22.1
13.5
14.5
0.59
10.0
1.1
10.0
26.5
32.0
1560
1560
14.8
18.5
18.0
19.0
0.89
13.0
1.4
13.0
TYPICAL DC CONTACT RATING (RESISTIVE) (Note 2)
LOAD VOLTAGE (VDC)
300
250
200
150
100
50
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
LOAD CURRENT (AMPS DC)
FIGURE 1
S114 Page 81
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
www.teledynerelays.com
©2003 TELEDYNE RELAYS
S114/1203/Q1
CENTIGRID® AND TO-5
Nom.
Max.
S114, 114D
S114DD (Note 4)
Min.
(Note 5)
Max.
S114, S114D
S114DD
Min.
S114, 114D
Max.
Min.
S114DD
Max.
Coil Voltage (Vdc)
SERIES S114
OUTLINE DIMENSIONS AND RECOMMENDED PAD LAYOUT (Notes 7, 8 & 9)
.335 MAX
(8.51)
TERMINAL LOCATIONS
& SCHEMATIC DIAGRAMS
7
.275 MAX
(6.99)
8
1
.360 MAX
(9.14)
2
6
.378 +.030
–.020 TYP
9.60 +.76
–.51
(
Ø.017 REF
(.43)
)
S114
2° ±2° TYP
5
4
3
7
8 (± ) 1
.031 REF (.79)
.035 REF
(.89)
.100 4 PL
(2.54)
4° MAX TYP
2
6
4° MAX TYP
.045 MIN 8 PL
(1.14)
.100 TYP (2.54)
S114D
.200
(5.08)
.410 MIN
(10.41)
.375 SQ MAX
(9.53)
.200
(5.08)
5
4 (+) 3
7
8 (± ) 1
.200
(5.08)
(Note 6)
GENERAL NOTES
1. Relay contacts will exhibit no chatter in excess of 10 msec or transfer in excess of
1 msec.
2. “Typical” characteristics are based on available data and are best estimates. No on-going
verification tests are performed.
3. Unless otherwise specified, parameters are initial values.
4. For reference only. Coil resistance not directly measurable at relay terminals due to
internal series diode.
5. Measured at nominal voltage for 5 sec. max.
6. Position of leads as they emerge from relay base.
7. Leads will fit noted pad layout with no overhang.
8. Lead ends are coplanar within .008" wide tolerance zone.
9. Terminals coated with SN60 or SN63 solder per QQ-S-571. Kovar exposed at sheared
end of leads.
10.
CENTIGRID® AND TO-5
2
6
DIMENSIONS ARE SHOWN IN INCHES (MILLIMETERS)
5
4 (+) 3
S114DD
SCHEMATICS ARE VIEWED
FROM TERMINALS
Teledyne Part Numbering System for Surface Mount Relays
S
114
D - 26
SURFACE
MOUNT
SERIES NO.
DD = SUPPRESSION DIODE
DD = SUPPRESSION AND POLARITY PROTECTION DIODES
©2003 TELEDYNE RELAYS
COIL VOLTAGE
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
www.teledynerelays.com
S114 Page 82
S114/1203/Q1