TOSHIBA TA6009FNG

TA6009FN/FNG
TOSHIBA Bipolar Linear Integrated Circuit Silicon Monolithic
TA6009FN,TA6009FNG
Shock Sensor IC (1 ch version)
TA6009FN/FNG detects an existence of external shock through
the shock sensor and output.
Features
•
TA6009FN/FNG operates from 2.7 to 5.5 V DC single power
supply voltage.
•
Signal from the shock sensor is amplified according to setting
gain, and is detected through the internal window
comparator.
•
TA6009FN/FNG incorporates 1-ch shock detecting circuitry.
•
Input terminal of sensor signal is designed high impedance.
Weight: 0.04 g (typ.)
Differential input impedance = 100 MΩ (typ.)
•
LPF (low pass filter) circuitry is incorporated.
•
Sensitivity of shock detection can be adjusted by external devices.
•
Small package
Cut-off frequency of LPF = 7 kHz
SSOP10-P-0.65A (0.65 mm pitch)
Block Diagram
Pin Connection (top view)
10
A
1
B
2
9
BUFFER
50 MΩ
DIFF&LPF
×10 7 kHz
BUFFER
50 MΩ
(
R 1.7 V (1.7 V)
E 1.4 V (1.2 V)
F 1.1 V (0.7 V)
) = 10 pin → GND
GUARD
0.57 V
8
7
−
+OP-AMP
6
VCC
+
− Comparator
SIA
1
10 W-CONT
SIB
2
9
DO
GUARD
3
8
AI
OUT
4
7
AO
GND
5
6
VCC
5
GND
+ Comparator
−
3
GUARD
4
1
2003-12-03
TA6009FN/FNG
Pin Function
Pin No.
Pin Name
Function
1
SIA
Connection terminal of shock sensor
2
SIB
Connection terminal of shock sensor
3
GUARD
4
OUT
Output terminal (output = “L” when shock is detected.)
5
GND
Ground terminal
6
VCC
Power supply voltage
7
AO
Op-Amp output terminal
8
AI
Op-Amp input terminal
9
DO
Differential-Amp output terminal
10
W-CONT
Input (1, 2 pin) GUARD terminal
WindComp. trip voltage selection terminal
Maximum Ratings (Ta = 25°C)
Characteristics
Power supply voltage
Symbol
Rating
Unit
VCC
7
V
Power dissipation
PD
300
mW
Storage temperature
Tstg
−55 to 150
°C
Rating
Unit
Recommend Operating Condition
Characteristics
Symbol
Power supply voltage
VCC
2.7 to 5.5
V
Operating temperature
Topr
−25 to 85
°C
2
2003-12-03
TA6009FN/FNG
Electrical Characteristics (unless otherwise specified, VCC = 3.3 V, Ta = 25°C)
Symbol
Test
Circuit
Test Condition
Min
Typ.
Max
Unit
Supply voltage
VCC
⎯
⎯
2.7
3.3
5.5
V
Supply current
ICC
(1)
VCC = 3.3 V
1.8
2.4
VCC = 5.0 V
1.8
2.4
Symbol
Test
Circuit
Test Condition
Min
Typ.
Max
Unit
VoGur
(2)
⎯
0.52
0.57
0.62
V
Symbol
Test
Circuit
Test Condition
Min
Typ.
Max
Unit
Characteristics
mA
(GUARD)
Characteristics
Output voltage
(DIFF-AMP)
Characteristics
Zin
⎯
⎯
50
100
Gain
GvBuf
(3)
⎯
19.6
20
20.4
dB
Output DC voltage
VoBuf
(4)
Connect C = 100 pF between
1 pin and 2 pin
0.7
1
1.3
V
fc
(5)
Frequency at −3dB point
5
7
10
kHz
Output source current
IBso
(6)
Voh = VCC − 1 V
400
800
µA
Output sink current
IBsi
(7)
Vol = 0.3 V
75
130
µA
Typ.
Input impedance
(Note 1)
Low pass filter cut-off freq.
MΩ
Note 1: Marked parameters are reference data.
(OP-AMP)
Characteristics
Symbol
Test
Circuit
Test Condition
Min
Max
Unit
Cut-off frequency
(Note 1)
fT
⎯
⎯
1.5
2
MHz
Openloop gain
(Note 1)
Gvo
⎯
⎯
80
90
dB
Input voltage 1
Vin1
(8)
10 pin → OPEN
(Note 2)
1.33
1.4
1.47
V
Input voltage 2
Vin2
(9)
10 pin → GND
(Note 2)
1.14
1.2
1.26
V
Iin
(10)
⎯
25
50
nA
Voff
⎯
⎯
−5
0
5
mV
Output source current
IAso
(11)
Voh = VCC − 1 V
300
800
µA
Output sink current
IAsi
(12)
Vol = 0.3 V
130
200
µA
Min
Typ.
Max
Unit
Input current
Offset voltage
(Note 1)
Note 1: Marked parameters are reference data.
Note 2: 10 pin must be non-connected otherwise connected to GND.
(window-comparator)
Characteristics
Symbol
Test
Circuit
Test Condition
Trip voltage 1
(Note 1)
Vtrp1
⎯
10 pin → OPEN
(Note 2)
Vin1
±0.285
Vin1
±0.3
Vin1
±0.315
V
Trip voltage 2
(Note 1)
Vtrp2
⎯
10 pin → GND
(Note 2)
Vin2
±0.475
Vin2
±0.5
Vin2
±0.525
V
Output source current
IWso
(13)
Voh = VCC − 0.5 V
30
50
µA
Output sink current
IWsi
(14)
Vol = 0.3 V
300
800
µA
Note 1: Marked parameters are reference data.
Note 2: 10 pin must be non-connected otherwise connected to GND.
3
2003-12-03
TA6009FN/FNG
Application Note
1.7 V (1.7 V)
Buffer
×1
C2
1
R2
AMP
×10
Shock
sensor
LPF
9
C1
R1
8
7
Window
Comparator
4 OUT
2
Buffer
×1
1.4 V (1.2 V) REF
1.1 V (0.7 V)
Figure 1 The Composition of G-Force Sense Amplifier
Figure 1 is the composition of G-Force sense amplifier.
The shock sensor is connected between 1 and 2 terminal.
When G-force Sensor (sensor sensibility = s (mV/G)) is used to detect external shock of g (G), the external
parts are determined as following.
(gain setting) * 10 PIN → GND
500/(s × g) = G1
G1/10 = G (OP-AMP)
(HPF setting)
fc = 1/(2 π × R1 × C1)
(LPF setting)
fc = 1/(2 π × R2 × C2)
4
2003-12-03
TA6009FN/FNG
Reference Data
(1)
9 pin (DIFF-AMP output) CMRR, PSRR
CMRR, PSRR (9 pin)
−30
−40
CMRR
(dB)
−50
−60
PSRR
−70
−80
100
1000
10000
100000
(Hz)
(2)
7 pin (OP-AMP output) source current
Source Current (7 pin)
1800
85°C
Source current
(µA)
1500
1200
900
25°C
600
−25°C
300
0
1.8
2.0
2.2
Voh
2.6
(V)
7 pin (OP-AMP output) sink current
Sink Current (7 pin)
300
85°C
(µA)
250
Sink current
(3)
2.4
25°C
200
−25°C
150
100
50
0
0
0.1
0.2
0.3
0.4
0.5
Vol (V)
5
2003-12-03
6 kΩ
8
AMP
10 µA
10 µA
6
10 kΩ
1 kΩ
250 Ω
1.5 kΩ
500 Ω
9
4
50 µA
6 kΩ
1.7 V
VREF
22 kΩ
13.59 kΩ
50 µA
50 µA
100 Ω
10 µA
50 µA
100 Ω
10 µA
TA6009FN/FNG
Equivalent Circuit
7
100 Ω
3
7
10 kΩ
10
2003-12-03
TA6009FN/FNG
Test Circuit
Supply current ICC
(2)
GUARD
Output voltage VoGur
30 kΩ
(1)
8
7
6
1
2
3
4
5
M
10
9
8
7
6
1
2
3
4
5
3.3 V
9
3.3 V
10
M
(3)
DIFF-AMP
Gain GvBuf
Step 1
Step 2
M1
M2
M
9
8
7
6
1
2
3
4
5
10
9
8
7
6
1
2
3
4
5
0.6 V
0.68 V
3.3 V
10
3.3 V
M
Gain =
DIFF-AMP
Output DC voltage VoBuf
(5)
DIFF-AMP
Low pass filter cut-off freq. fc
M
9
8
7
6
1
2
3
4
5
10
9
8
7
6
0.1 µF 1
2
3
4
5
7
100 kΩ
100 pF
100 kΩ
3.3 V
10
3.3 V
M
100 pF
(4)
Μ2 − Μ1
0.68 − 0.60
2003-12-03
TA6009FN/FNG
(6)
DIFF-AMP
Output source current IBso
(7)
DIFF-AMP
Output sink current IBsi
9
8
7
6
1
2
3
4
5
10
9
8
7
6
1
2
3
4
5
M
9
8
7
6
1
2
3
4
5
10
9
8
7
6
1
2
3
4
5
3.3 V
10
3.3 V
M
OP-AMP
Input voltage 2 Vin2
30 kΩ
(9)
30 kΩ
OP-AMP
Input voltage 1 Vin1
0.5 V
0.62 V
0.65 V
0.45 V
(8)
3.3 V
10
0.3 V
M
3.3 V
2.3 V
M
(10) OP-AMP
Input current Iin
10
9
8
7
6
1
2
3
4
5
3.3 V
1.2 V
M
(11) OP-AMP
Output source current IAso
(12) OP-AMP
Output sink current IAsi
8
7
6
1
2
3
4
5
10
9
8
7
6
1
2
3
4
5
3.3 V
9
1.6 V
10
0.3 V
M
3.3 V
1.2 V
2.3 V
M
8
2003-12-03
TA6009FN/FNG
8
7
6
1
2
3
4
5
10
9
8
7
6
1
2
3
4
5
M
0.3 V
2.85 V
3.3 V
9
1.4 V
10
0.6 V
(14) Window comparator
Output sink current IWsi
3.3 V
3.3 V
1.2 V
(13) Window comparator
Output source current IWso
M
Test Circuit (for reference)
DIFF-AMP
CMRR
(b)
M
10
9
8
7
6
1
2
3
4
5
10
9
8
7
6
1
2
3
4
5
3.3 V
M
DIFF-AMP
PSRR
3.3 V
(a)
9
2003-12-03
TA6009FN/FNG
Package Dimensions
Weight: 0.04 g (typ.)
10
2003-12-03
TA6009FN/FNG
RESTRICTIONS ON PRODUCT USE
030619EAA
• The information contained herein is subject to change without notice.
• The information contained herein is presented only as a guide for the applications of our products. No
responsibility is assumed by TOSHIBA for any infringements of patents or other rights of the third parties which
may result from its use. No license is granted by implication or otherwise under any patent or patent rights of
TOSHIBA or others.
• TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless, semiconductor
devices in general can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical
stress. It is the responsibility of the buyer, when utilizing TOSHIBA products, to comply with the standards of
safety in making a safe design for the entire system, and to avoid situations in which a malfunction or failure of
such TOSHIBA products could cause loss of human life, bodily injury or damage to property.
In developing your designs, please ensure that TOSHIBA products are used within specified operating ranges as
set forth in the most recent TOSHIBA products specifications. Also, please keep in mind the precautions and
conditions set forth in the “Handling Guide for Semiconductor Devices,” or “TOSHIBA Semiconductor Reliability
Handbook” etc..
• The TOSHIBA products listed in this document are intended for usage in general electronics applications
(computer, personal equipment, office equipment, measuring equipment, industrial robotics, domestic appliances,
etc.). These TOSHIBA products are neither intended nor warranted for usage in equipment that requires
extraordinarily high quality and/or reliability or a malfunction or failure of which may cause loss of human life or
bodily injury (“Unintended Usage”). Unintended Usage include atomic energy control instruments, airplane or
spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments,
medical instruments, all types of safety devices, etc.. Unintended Usage of TOSHIBA products listed in this
document shall be made at the customer’s own risk.
• TOSHIBA products should not be embedded to the downstream products which are prohibited to be produced
and sold, under any law and regulations.
11