BLP30 AC-DC Series Data Sheet 30 Watts Features • • • • • • • • • • • • Applications • • • • • • • Datacom (hubs, routers) POS terminals Industrial Cable modems External disk storage Medical instrumentation Computers RoHS compliant for all six substances 2” x 4” footprint Component height less than 1” 25 W rating with natural convection cooling 30 W rating with 10 CFM airflow Compliance to EMI Class B Universal AC input Short-circuit protection Overvoltage protection CE marked to Low Voltage Directive (Pending) Compliance to EN61000-4-2/-3/-4/-5/-6/-8/-11 Two-year warranty Description The BLP30 Series’ economical and compact construction provides single or three-output AC to DC power conversion to meet the requirements of most commercial and industrial applications. Single-Output Model Selection Model Nominal Output Voltage (VDC) Min-Max Output Current (Amps), Convection Min-Max Output Current (Amps), 1 Forced Air Peak Output Current (Amps) 2 Total Regulation 3 (%) Ripple & Noise 4 pk-pk % BLP30-1005G 5V 0–5 0–6 7.2 ±2 1 BLP30-1012G 12V 0 – 2.1 0 – 2.5 3.0 ±2 1 BLP30-1024G 24V 0 – 1.0 0 – 1.25 1.5 ±2 0.6 Nominal Output Voltage (VDC) Min-Max Output Current (Amps), Convection Min-Max Output Current (Amps), Forced Air 1 Peak Output Current (Amps) 2 Total Regulation (%) 3 Ripple & Noise 4 pk-pk % +5V 0.2 – 2.5 0.2 – 3.5 5 ±2 1% +12V 0.1 – 1.2 0.1 – 2.0 3 ±5 1% -12V 0.0 – 0.3 0.0 – 0.5 1 ±5 1% Triple-Output Model Selection Model BLP30-3000G 1 2 3 4 10 CFM or 260 LFM (average measurement of six equally-distributed points through a 3.5" x 1.6" (9 cm x 4 cm) cross-sectional area with power supply mounted on a 0.25" (6.35 mm) standoffs. Recommended airflow direction is from the AC input to the DC output. Peak current duration for less than 30 seconds with a max duty cycle of 10%. At 25 °C ambient including voltage set point tolerance, line, and load regulation Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth, measured with a twisted pair differentially across a 10 µF E-cap and a 0.1 µF ceramic cap in parallel. The point of measurement is within 1 cm of the output connection. JUL 05, 2006 revised to DEC 05, 2006 Page 1 of 6 www.power-one.com BLP30 AC-DC Series Data Sheet 30 Watts ELECTRICAL SPECIFICATIONS Input Specifications Parameter Input Voltage - AC Conditions/Description Single-phase continuous input range Input Voltage - DC Input Frequency AC Input Input Current At 90 VAC input., 30W Inrush Surge Current Internally limited. 115 VAC, Max Power, 25 °C Internally limited. 230 VAC, Max Power, 25 °C Input fuse Non-user serviceable internally located AC input line fuse is provided. Efficiency At maximum output power. Min. Nom. Max. Units 90 100 - 250 264 VAC 127 160/325 375 VDC 47 50 - 60 63 Hz 0.75 16 32 70 Switching Frequency A rms 75 60 A pk A pk % 69 kHz Output Specifications Max. Units Output power Parameter With convection cooling. See Model Selection. With forced-air cooling. See Model Selection. Conditions/Description Min. Nom. 25 30 Watts Load transient Vo1, Vo2, or Vo3 deviation due to a 50 to 100% load change at a rate of 1A/µs. ±5 % Turn on Delay Time required for outputs to be within regulation after initial application of AC input. 1.5 Sec Rise Time Time required for output voltage to rise from 10% to 90%. 20 ms Hold-up Time At 30W, 115 VAC, 60 Hz. Overvoltage Protection Main output. 20 5V: 12V: 24V: 5.6 14.0 29.0 Ms 6.9 16.7 34.2 V Short-circuit Protection Fully-protected against output short circuit. Overshoot Single-output models. 2 % Overshoot Triple-output models. 5 % JUL 05, 2006 revised to DEC 05, 2006 Page 2 of 6 www.power-one.com BLP30 AC-DC Series Data Sheet 30 Watts Regulatory & Safety Approvals Parameter Conditions/Description UL60950-1 All models are approved. CSA-C22.2, No. 60950-1-03 All models are approved. EN 60950-1 /IEC 60950-1 All models are approved. CE Mark for LVD All models are approved. CB Approval Completed. Ground Continuity At 12 VDC. Dielectric Withstand Voltage Input-to-Ground (Basic) . Input-to-Output (Reinforced). The primary to secondary test is not performed on completed assemblies. Output-to-Ground (Functional). Nom. Max. Units 30 A 2121 VDC 4242 VDC 500 VDC B B Class Electromagnetic Interference FCC Part 15. CISPR 22 and CISPR 11. ESD Per EN 61000-4-2, level 2. Radiated Susceptibility Per EN 61000-4-3, level 3. EFT/Burst Per EN 61000-4-4, level 3. Input Transient Protection Per EN 61000-4-5, class 3. RF Immunity Per EN 61000-4-6, level 3. 3 V/m Magnetic Fields Per EN 61000-4-8. 1 A/m Voltage Interruptions Per EN 61000-4-11 Leakage Current Per EN 60950 JUL 05, 2006 revised to DEC 05, 2006 Conducted: Conducted: Min. 3 Line-to-Line: Line-to-Ground: At 115 VAC: At 230 VAC: Page 3 of 6 V/m 1 kV 1 2 kV 0.2 0.4 mA www.power-one.com BLP30 AC-DC Series Data Sheet 30 Watts Environmental Specifications Parameter Conditions/Description Altitude Operating. Non-Operating. Operating Temp 0 ºC to 70 ºC with linear derating to 50% above 50 ºC. Unit will start-up at -20 ºC, but will not meet all published specifications. Storage Temp Min. 0 Nom. 50 -40 Max. Units 10K 50K ASL ft ASL ft 70 ºC 85 ºC Temperature Coefficient 0 ºC to 70 ºC (after 15-minute warm-up). Relative Humidity 95% relative humidity @ 40 ºC, non-condensing 95 %RH Shock Operating: half-sine, 11 ±3 ms, 3-axis. 15 G Non-Operating: half-sine, 11 ±3 ms, 3-axis. 40 G Operating: Random vibration; 5 to 500 Hz (10 minutes, each axis). 2.4 Grms 6 Grms Vibration Non-Operating: Random vibration; 5 to 500 Hz (10 minutes, each axis). JUL 05, 2006 revised to DEC 05, 2006 Page 4 of 6 %/ ºC ±0.02 www.power-one.com BLP30 AC-DC Series Data Sheet 30 Watts Mechanical Drawing – Single Output Models All dimensions are in inches. CN1 - AC CONN. Pin 1 Pin 3 Pin 5 4.00 +/- 02 TOP VIEW 1.750 Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin #1 VOUT DC COM VOUT DC COM VOUT CN2 - DC output connector (see pin-out table) CN1 input connector 2.07 +/-.02 CN2 - DC CON Ø 0.16 (4 places) 3.750 AC Neutral AC Line AC Ground Pin #1 PCB AC Ground Connection Point - Solder side fastener clearance area 0.25 DIA (4 places) 0.06 1.07 +/-.02 END VIEW 0.91 SIDE VIEW Printed Circuit Board 0.1 * RECOMMENDED MATING CONNECTORS HOUSING CN1 and CN2 * PIN MOLEX 22-01-2051 MOLEX 22-01-2057 MOLEX 22-01-3057 MOLEX 08-52-0123 MOLEX 08-52-0101 LEOCO 2530S05000 LEOCO 2533TPB0000 Equivalent housings and pins can also be used. JUL 05, 2006 revised to DEC 05, 2006 Page 5 of 6 www.power-one.com BLP30 AC-DC Series Data Sheet 30 Watts Mechanical Drawing – Triple Output Model All dimensions are in inches. CN1 - AC CONN. Pin 1 Pin 3 Pin 5 4.00 +/- 02 TOP VIEW 2.00 +/-.02 1.750 CN2 - DC CON Ø 0.16 (4 places) 3.750 AC Neutral AC Line AC Ground Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin #1 Vo3 DC Com Vo1 DC COM Vo2 CN2 - DC output connector (see pin-out table) CN1 input connector Pin #1 PCB AC Ground Connection Point - Solder side fastener clearance area 0.25 DIA (4 places) 0.06 1.07 +/-.02 END VIEW 0.91 SIDE VIEW Printed Circuit Board 0.1 * RECOMMENDED MATING CONNECTORS HOUSING CN1 and CN2 * PIN MOLEX 22-01-2051 MOLEX 22-01-2057 MOLEX 22-01-3057 MOLEX 08-52-0123 MOLEX 08-52-0101 LEOCO 2530S05000 LEOCO 2533TPB0000 Equivalent housings and pins can also be used. NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. JUL 05, 2006 revised to DEC 05, 2006 Page 6 of 6 www.power-one.com