POWER-ONE BLP30

BLP30 AC-DC Series Data Sheet
30 Watts
Features
•
•
•
•
•
•
•
•
•
•
•
•
Applications
•
•
•
•
•
•
•
Datacom (hubs, routers)
POS terminals
Industrial
Cable modems
External disk storage
Medical instrumentation
Computers
RoHS compliant for all six substances
2” x 4” footprint
Component height less than 1”
25 W rating with natural convection cooling
30 W rating with 10 CFM airflow
Compliance to EMI Class B
Universal AC input
Short-circuit protection
Overvoltage protection
CE marked to Low Voltage Directive (Pending)
Compliance to EN61000-4-2/-3/-4/-5/-6/-8/-11
Two-year warranty
Description
The BLP30 Series’ economical and compact construction provides single or three-output AC to DC power
conversion to meet the requirements of most commercial and industrial applications.
Single-Output Model Selection
Model
Nominal
Output Voltage
(VDC)
Min-Max Output
Current (Amps),
Convection
Min-Max Output
Current (Amps),
1
Forced Air
Peak Output
Current
(Amps) 2
Total
Regulation
3
(%)
Ripple &
Noise
4
pk-pk %
BLP30-1005G
5V
0–5
0–6
7.2
±2
1
BLP30-1012G
12V
0 – 2.1
0 – 2.5
3.0
±2
1
BLP30-1024G
24V
0 – 1.0
0 – 1.25
1.5
±2
0.6
Nominal
Output Voltage
(VDC)
Min-Max Output
Current (Amps),
Convection
Min-Max Output
Current (Amps),
Forced Air 1
Peak Output
Current
(Amps) 2
Total
Regulation
(%) 3
Ripple &
Noise
4
pk-pk %
+5V
0.2 – 2.5
0.2 – 3.5
5
±2
1%
+12V
0.1 – 1.2
0.1 – 2.0
3
±5
1%
-12V
0.0 – 0.3
0.0 – 0.5
1
±5
1%
Triple-Output Model Selection
Model
BLP30-3000G
1
2
3
4
10 CFM or 260 LFM (average measurement of six equally-distributed points through a 3.5" x 1.6" (9 cm x 4 cm) cross-sectional area with
power supply mounted on a 0.25" (6.35 mm) standoffs. Recommended airflow direction is from the AC input to the DC output.
Peak current duration for less than 30 seconds with a max duty cycle of 10%.
At 25 °C ambient including voltage set point tolerance, line, and load regulation
Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth, measured with a twisted pair differentially
across a 10 µF E-cap and a 0.1 µF ceramic cap in parallel. The point of measurement is within 1 cm of the output connection.
JUL 05, 2006 revised to DEC 05, 2006
Page 1 of 6
www.power-one.com
BLP30 AC-DC Series Data Sheet
30 Watts
ELECTRICAL SPECIFICATIONS
Input Specifications
Parameter
Input Voltage - AC
Conditions/Description
Single-phase continuous input range
Input Voltage - DC
Input Frequency
AC Input
Input Current
At 90 VAC input., 30W
Inrush Surge Current
Internally limited. 115 VAC, Max Power, 25 °C
Internally limited. 230 VAC, Max Power, 25 °C
Input fuse
Non-user serviceable internally located AC
input line fuse is provided.
Efficiency
At maximum output power.
Min.
Nom.
Max.
Units
90
100 - 250
264
VAC
127
160/325
375
VDC
47
50 - 60
63
Hz
0.75
16
32
70
Switching Frequency
A rms
75
60
A pk
A pk
%
69
kHz
Output Specifications
Max.
Units
Output power
Parameter
With convection cooling. See Model Selection.
With forced-air cooling. See Model Selection.
Conditions/Description
Min.
Nom.
25
30
Watts
Load transient
Vo1, Vo2, or Vo3 deviation due to a 50 to 100%
load change at a rate of 1A/µs.
±5
%
Turn on Delay
Time required for outputs to be within regulation
after initial application of AC input.
1.5
Sec
Rise Time
Time required for output voltage to rise from
10% to 90%.
20
ms
Hold-up Time
At 30W, 115 VAC, 60 Hz.
Overvoltage Protection
Main output.
20
5V:
12V:
24V:
5.6
14.0
29.0
Ms
6.9
16.7
34.2
V
Short-circuit Protection
Fully-protected against output short circuit.
Overshoot
Single-output models.
2
%
Overshoot
Triple-output models.
5
%
JUL 05, 2006 revised to DEC 05, 2006
Page 2 of 6
www.power-one.com
BLP30 AC-DC Series Data Sheet
30 Watts
Regulatory & Safety Approvals
Parameter
Conditions/Description
UL60950-1
All models are approved.
CSA-C22.2,
No. 60950-1-03
All models are approved.
EN 60950-1
/IEC 60950-1
All models are approved.
CE Mark for LVD
All models are approved.
CB Approval
Completed.
Ground Continuity
At 12 VDC.
Dielectric Withstand
Voltage
Input-to-Ground (Basic)
.
Input-to-Output (Reinforced). The primary to
secondary test is not performed on completed
assemblies.
Output-to-Ground (Functional).
Nom.
Max.
Units
30
A
2121
VDC
4242
VDC
500
VDC
B
B
Class
Electromagnetic
Interference
FCC Part 15.
CISPR 22 and CISPR 11.
ESD
Per EN 61000-4-2, level 2.
Radiated Susceptibility
Per EN 61000-4-3, level 3.
EFT/Burst
Per EN 61000-4-4, level 3.
Input Transient
Protection
Per EN 61000-4-5, class 3.
RF Immunity
Per EN 61000-4-6, level 3.
3
V/m
Magnetic Fields
Per EN 61000-4-8.
1
A/m
Voltage Interruptions
Per EN 61000-4-11
Leakage Current
Per EN 60950
JUL 05, 2006 revised to DEC 05, 2006
Conducted:
Conducted:
Min.
3
Line-to-Line:
Line-to-Ground:
At 115 VAC:
At 230 VAC:
Page 3 of 6
V/m
1
kV
1
2
kV
0.2
0.4
mA
www.power-one.com
BLP30 AC-DC Series Data Sheet
30 Watts
Environmental Specifications
Parameter
Conditions/Description
Altitude
Operating.
Non-Operating.
Operating Temp
0 ºC to 70 ºC with linear derating to 50% above
50 ºC. Unit will start-up at -20 ºC, but will not
meet all published specifications.
Storage Temp
Min.
0
Nom.
50
-40
Max.
Units
10K
50K
ASL ft
ASL ft
70
ºC
85
ºC
Temperature
Coefficient
0 ºC to 70 ºC (after 15-minute warm-up).
Relative Humidity
95% relative humidity @ 40 ºC, non-condensing
95
%RH
Shock
Operating: half-sine, 11 ±3 ms, 3-axis.
15
G
Non-Operating: half-sine, 11 ±3 ms, 3-axis.
40
G
Operating: Random vibration; 5 to 500 Hz
(10 minutes, each axis).
2.4
Grms
6
Grms
Vibration
Non-Operating: Random vibration; 5 to 500 Hz
(10 minutes, each axis).
JUL 05, 2006 revised to DEC 05, 2006
Page 4 of 6
%/ ºC
±0.02
www.power-one.com
BLP30 AC-DC Series Data Sheet
30 Watts
Mechanical Drawing – Single Output Models
All dimensions are in inches.
CN1 - AC CONN.
Pin 1
Pin 3
Pin 5
4.00 +/- 02
TOP VIEW
1.750
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin #1
VOUT
DC COM
VOUT
DC COM
VOUT
CN2 - DC output
connector
(see pin-out
table)
CN1 input
connector
2.07
+/-.02
CN2 - DC CON
Ø 0.16 (4 places)
3.750
AC Neutral
AC Line
AC Ground
Pin #1
PCB AC Ground Connection
Point - Solder side
fastener
clearance area
0.25 DIA (4
places)
0.06
1.07
+/-.02
END VIEW
0.91
SIDE VIEW
Printed Circuit Board
0.1
*
RECOMMENDED MATING CONNECTORS
HOUSING
CN1 and CN2
*
PIN
MOLEX 22-01-2051
MOLEX 22-01-2057
MOLEX 22-01-3057
MOLEX 08-52-0123
MOLEX 08-52-0101
LEOCO 2530S05000
LEOCO 2533TPB0000
Equivalent housings and pins can also be used.
JUL 05, 2006 revised to DEC 05, 2006
Page 5 of 6
www.power-one.com
BLP30 AC-DC Series Data Sheet
30 Watts
Mechanical Drawing – Triple Output Model
All dimensions are in inches.
CN1 - AC CONN.
Pin 1
Pin 3
Pin 5
4.00 +/- 02
TOP VIEW
2.00
+/-.02
1.750
CN2 - DC CON
Ø 0.16 (4 places)
3.750
AC Neutral
AC Line
AC Ground
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin #1
Vo3
DC Com
Vo1
DC COM
Vo2
CN2 - DC output
connector
(see pin-out
table)
CN1 input
connector
Pin #1
PCB AC Ground Connection
Point - Solder side
fastener
clearance area
0.25 DIA (4
places)
0.06
1.07
+/-.02
END VIEW
0.91
SIDE VIEW
Printed Circuit Board
0.1
*
RECOMMENDED MATING CONNECTORS
HOUSING
CN1 and CN2
*
PIN
MOLEX 22-01-2051
MOLEX 22-01-2057
MOLEX 22-01-3057
MOLEX 08-52-0123
MOLEX 08-52-0101
LEOCO 2530S05000
LEOCO 2533TPB0000
Equivalent housings and pins can also be used.
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical
components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent
of the respective divisional president of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
JUL 05, 2006 revised to DEC 05, 2006
Page 6 of 6