NSC LM360MX

Company
National Semiconductor
Contact
Steve Osborne
Title
Product Ecology Engineer
Part Number
LM360MX
DUNS#
04-147-2986
URL for Additional Information
http://www.national.com/quality/green/
Phone
1-408-721-7838
Email
[email protected]
MSL Rating
Peak Body Temp C
MaxTime (Sec)
Cycles
Unit Type
1
260
40
4
Each
NOPB
European RoHS Compliant.
China RoHS Compliant
Document Date
26-Apr-2008
Weight (mg)
69.76
Homogeneous Material Composition Declaration for Electronic Products
Item
Weight (mg)
Component
CAS#
Weight (mg)
40039-93-8
0.358
8,000
5,127
Leadframe
20.56 Cu
7440-50-8
20.036
974,500
287,209
Fe
7439-89-6
0.493
24,000
7,073
Zn
7440-66-6
0.025
1,200
354
P
7723-14-0
0.006
300
88
Chip
2.36 Si
7440-21-3
2.346
994,000
33,627
Al
7429-90-5
0.014
6,000
203
Ext. LeadFinish
1.60 Sn
7440-31-5
1.600
1,000,000
22,936
Die Attach
0.27 Ag
7440-22-4
0.203
750,000
2,903
25928-94-3
0.068
250,000
968
7440-22-4
0.180
1,000,000
2,580
Epoxy Resin
Int. LeadFinish
0.18 Ag
36.215
7.243
0.894
810,000
162,000
20,000
Part-ppm
44.71 SiO2
Epoxy Resin
Sb2O3
Brominated Epoxy
60676-86-0
25928-94-3
1309-64-4
Item-ppm
Plastic
519,138
103,828
12,818
Wires
0.08 Au
7440-57-5
0.080
1,000,000
1,147
Note: The device content disclosed herewith is approximate and is based on engineering estimates only. It has not been verified through analytical testing.
Additionally, the following should be noted:
1. One or more dopant materials may be present in the silicon die at sub-ppm levels to provide semiconductor properties.
2. Epoxy resin components listed are generic and may or may not be the specific compound used, which is considered proprietary.
RoHS Material Composition Declaration
RoHS Directive
2002/95/EC
RoHS Definition: Quantity limit of 0.1% by mass (1000 PPM) in homogeneous material for: Lead (Pb), Mercury, Hexavalent
Chromium, Polybrominated Biphenyls (PBB), Polybrominated Diphenyl Ethers (PBDE) and quantity limit of 0.01% by mass
(100 PPM) of homogeneous material for Cadmium
Subject to the limitations below, National Semiconductor Corporation (“National”) certifies the following information as of the document date.
1. National products designated “ROHS Compliant” comply with the European Union’s Directive on the Restriction of the Use of Hazardous Substances
2002/95/EC (“RoHS”). These products do not contain Joint Industry Guide (JIG) -101 Level A substances above threshold limits, except lead in RoHS
exempt applications 5, 7a and 7c. These products do not contain perfluorooctane sulfonates (PFOS).
2. National products are manufactured in conformance with National specifications (SC) CSP-9-111C1 Supplier Environmental Requirements for
Materials and Products and (SC) CSP-9-111S2 List of Banned and Reportable Substances, which are available at www.national.com/quality/green/.
National has taken commercially reasonable steps to provide representative and accurate information but may not have independently verified information
provided or conducted chemical analysis of incoming materials. Equivalent compliant materials may have been substituted for those stated herein.
Material concentrations are the maximum expected concentration of the substances in the device and may not represent the actual concentration. National
and its suppliers consider certain limited information to be confidential and thus CAS numbers and other limited information may not be available for
release. National’s Standard Terms and Conditions of Sale apply to any issues arising out of or in connection with the information provided herein unless
otherwise provided by a written contract signed by both parties.
NATIONAL ACCEPTS NO DUTY TO NOTIFY USERS OF THIS DECLARATION OF UPDATES OR CHANGES TO THIS DECLARATION.
Gerry Fields
Vice President Quality
National Semiconductor
Page 1 of 2
Banned Substance Monitoring
Part Number
LM360MX
NOPB
Document Date
26-Apr-2008
European RoHS Compliant.
Item#
1
2
3
4
5
6
Material
CHIP
COMPOUND
EPOXY
EXTLF
FRAME
WIRE
Cd
<1
<2
<2
<2
<2
<2
CrVl
<1
<5
<5
<2
<2
<2
China RoHS Compliant
Pb
<1
<5
<5
30
15
<2
Hg
<30
<1
<1
<2
<2
<2
PBB
<10
<10
<10
NA
NA
NA
PBDE
<10
<10
<10
NA
NA
NA
Cl
NA
<20
160
NA
N/A
NA
Br
NA
<20
<20
NA
N/A
NA
Ref #
1000
637
32
595
53
132
* Cd: Cadmium, CrVI: Hexavalent Chromium, Pb: Lead, Hg: Mercury, ND: Not Detected
* Unless otherwise noted, units are in PPM (parts-per-million)
Ref #
1000
637
32
595
53
132
3rd Party Analysis (available upon request, subject to a non-disclosure agreement)
Analysis on 02/13/2008 by Balazs Analytical Services-Freemont CA per Report# 08-00823-00
Analysis on 03/14/2008 by ALS per Report# ATJB/0791BS/2008
Analysis on 03/14/2008 by ALS per Report# ATJB/0807BS/2008
Analysis on 03/14/2008 by SGS per Report# LPCI/03628/08
Analysis on 03/13/2007 by SGS per Report# LPCI/05143/07
Analysis on 04/09/2008 by SGS per Report# LPCI/06217/08
National Semiconductor