MA-COM 3EZP

Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
Chassis or PC Board Mountable Power Line Filters for Emission Control
X, Y, Z Series
UL Recognized
CSA Certified
VDE Approved
XP / YP / ZP
3EX1 / 3EZ1
X, Y, Z Series
• Compact chassis or PC board mountable
• Three levels of performance
• Complete filtering solution in minimal size
X Series
• Designed to bring most digital equipment
(including those with switching power supplies)
into compliance with FCC Part 15J, Class B
conducted emission limits
Y Series
• Designed to bring most digital equipment
(including those with switching power supplies)
into compliance with EN55022, Level A and FCC
Part 15J, Class B conducted emission limits
Z Series
Specifications
Maximum leakage current each Line to Ground:
@ 120 VAC 60 Hz:
.30 mA
@250 VAC 50 Hz:
.50 mA
Hipot rating (one minute):
Line to Ground:
Line to Line:
2250 VDC
1450 VDC
Rated Voltage (max):
250 VAC
Operating Frequency:
50/60 Hz
Rated Current:
1 to 6A
Operating Ambient Temperature Range
(at rated current Ir):
-10°C to +40°C
In an ambient temperature (Ta) higher than +40°C
the maximum operating current (Io) is calculated as
follows: Io = Ir (85-Ta)/45
Electrical Schematic
LINE
LOAD
• Designed to bring most digital equipment
(including those with switching power supplies)
into compliance with EN55022, Level B and FCC
Part 15J, Class B conducted emission limits
Ordering Information
3EX1
Input / Output Style
1 – .250 [6.3] spade terminals
P – PC board pins
X, Y or Z Series
Available Part Numbers
3EXP
3EX1
4EXP
6EXP
2EYP
3EYP
4EYP
1EZP
2EZP
3EZP
3EZ1
Leakage current designation
E – Low leakage (<0.5 mA)
Current Rating
1, 2, 3, 4 or 6A
92
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
Chassis & PC Board Mountable RFI Filters for Emission Control
(continued)
X, Y, Z Series
Case Styles
X1 & Z1
Case Dimensions
Part No.
3EXP
B
3EX1




C
4EXP
6EXP



2EYP
3EYP, 4EYP
XP, YP & ZP
1EZP
A
2EZP, 3EZP
3EZ1
B
C
























































D
E

























1
RFI Power Line Filters
D
E
A
A

C
Recommended PC Board Layout
2.660
67.56
0.123
Min.
3.12
1.850
46.99
.605
15.37
1.050
26.67
Grounds
B
Line
side
Load
side
.350
8.89
1.190 .700
30.23 17.78



.245
6.22
.150
3.81


93
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
Chassis & PC Board Mountable RFI Filters for Emission Control
(continued)
X, Y, Z Series
Performance Data
Typical Insertion Loss
Measured in closed 50 Ohm system
3EX
4EX
6EX
db
100
db
100
db
100
90
90
90
80
80
70
70
70
60
60
60
80
50
50
50
40
40
40
30
30
30
20
20
20
10
10
0
0
0.01
0.1
1
10
30
Frequency in MHz
10
0.01
0.1
1
10
30
Frequency in MHz
0
0.01
2EY
3EY
4EY
db
100
db
100
db
100
90
90
90
80
80
80
70
70
70
60
60
60
50
50
50
40
40
40
30
30
30
20
20
20
10
10
0
0
0.01
0.1
1
10
30
Frequency in MHz
0.1
1
10
30
Frequency in MHz
0
0.01
2EZ
3EZ
db
100
db
100
db
100
90
90
90
80
80
70
70
70
60
60
60
50
50
50
40
40
40
30
30
30
20
20
20
10
10
0.01
0.1
1
10
30
Frequency in MHz
0
1
10
30
Frequency in MHz
0.1
1
10
30
Frequency in MHz
0.1
1
10
30
Frequency in MHz
10
0.01
1EZ
0
0.1
80
10
0.01
0.1
1
10
30
Frequency in MHz
0
0.01
Common Mode / Asymmetrical (L-G)
Differential Mode / Symmetrical (L-L)
94
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
Chassis & PC Board Mountable RFI Filters for Emission Control
(continued)
Performance Data (Continued)
Minimum Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground)
Differential Mode / Symmetrical (Line to Line)



 




































































       
1
 

RFI Power Line Filters




























































































































95
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com