MA-COM 36FC10

Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
Single Phase Power Line Filter for Frequency Converters
FC Series
UL Recognized
FC Series
Specifications
• Designed for frequency inverters and variable
speed motor drives
• Suitable for electronically noisy environments
• Protects programmable logic controllers from RF
noise on the AC power line
• Side flanges for easy mounting
• Touch safe terminals provide easy connections
and prevent inadvertent contact for safety in the
most demanding applications
Maximum leakage current each Line to Ground:
B suffix
no suffix
@ 120 VAC 60 Hz:
3.9 mA
3.8 mA
@250 VAC 50 Hz:
7.0 mA
6.7 mA
Hipot rating (one minute):
Line to Ground:
Line to Line:
2250 VDC
1450 VDC
Rated Voltage (max):
250 VAC
Operating Frequency:
50/60 Hz
Rated Current:
6 to 50A
Operating Ambient Temperature Range
(at rated current Ir):
-10°C to +40°C
In an ambient temperature (Ta) higher than +40°C
the maximum operating current (Io) is calculated as
follows: Io = Ir (85-Ta)/45
Ordering Information
36 FC 10 B
Suffix
B – Single stage
Omit for dual stage
Input / Output Style
10 – DIN type terminal block
Electrical Schematics
FC10
LINE
LOAD
1
2
FC Series
1
Current Rating
6, 12, 16, 25, 36 or 50A


FC10B
Available Part Numbers
6FC10
12FC10
16FC10
25FC10
36FC10
50FC10


LINE
LOAD
12FC10B
16FC10B
25FC10B
36FC10B
50FC10B
30
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
Single Phase Filter for Frequency Converters
(continued)
FC Series
Case Styles
Case Dimensions
Part No.
FC10 / FC10B (6, 12, 16A)
A
B
C



D


E

F


1
    

     

12FC10/10B     
16FC10/10B      
     
25, 36, 50
FC10/10B
     
6FC10
D
B
F
E
A
This hole indicates
the "Line" side and
may be on either flange.




RFI Power Line Filters
C



FC10 / FC10B (25, 36, 50A )
This hole indicates the "Line" side
and may be on either flange.
D
B
C




F
E
A



31
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
Single Phase Filter for Frequency Converters
(continued)
FC Series
Performance Data
Typical Insertion Loss
Common Mode / Asymmetrical (L-G)
Differential Mode / Symmetrical (L-L)
Measured in closed 50 Ohm system
6FC10
12FC10
16FC10
db
100
db
100
db
100
90
90
90
80
80
80
70
70
70
60
60
60
50
50
50
40
40
40
30
30
30
20
20
20
10
10
0
0.01
0.1
1
0
10
30
Frequency in MHz
10
0.01
0.1
1
0
10
30
Frequency in MHz
0.01
0.1
25FC10
36, 50FC10
12, 16FC10B
db
100
db
100
db
100
90
90
90
80
80
80
70
70
70
60
60
60
50
50
50
40
40
40
30
30
30
20
20
20
10
10
0
0.01
0.1
1
0
10
30
Frequency in MHz
0.1
1
0
10
30
Frequency in MHz
0.01
0.1
36FC10B
50FC10B
db
100
db
100
db
100
90
90
90
80
80
80
70
70
70
60
60
60
50
50
50
40
40
40
30
30
30
20
20
20
10
10
0
0
0.1
1
10
30
Frequency in MHz
10
30
Frequency in MHz
1
10
30
Frequency in MHz
1
10
30
Frequency in MHz
10
0.01
25FC10B
0.01
1
10
0.01
0.1
1
0
10
30
Frequency in MHz
0.01
0.1
Minimum Insertion Loss
Common Mode / Asymmetrical (Line to Ground)


    


Differential Mode / Symmetrical (Line to Line)




    
























































































































































































32
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com