Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Performance RFI Power Line Filters for Switching Power Supplies T Series UL Recognized CSA Certified VDE Approved T Series Specifications • Superior common-mode and premium differential-mode attenuation • Smaller package sizes than the EP Series • Size and cost-effective • ET models can help meet very low leakage current requirements Maximum leakage current each Line to Ground: 3, 6 & 10A ET Models VT Models @120 VAC 60 Hz: .30 mA .75 mA @250 VAC 50 Hz: .50 mA 1.2 mA 15 & 20A @120 VAC 60 Hz: .30 mA 1.2 mA @250 VAC 50 Hz: .50 mA 2.0 mA Hipot rating (one minute): Line to Ground: Line to Line: Rated Voltage (max): 250 VAC Operating Frequency: 50/60 Hz Rated Current: Ordering Information 10 E T 1 Input / Output Style 1 – .250 [6.3] spade terminals 3 – Wire leads 6 – Threaded bolt 7 – IEC inlet* (line side) .250 [6.3] spade terminals (load side) T Series Leakage current designation E – Low leakage (<0.5 mA) V – Standard 2250 VDC 1450 VDC 3 to 20A Operating Ambient Temperature Range (at rated current Ir): -10°C to +40°C In an ambient temperature (Ta) higher than +40°C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 Available Part Numbers 3ET1 3ET3 3ET7 6ET1 6ET3 6ET7 10ET1 10ET3 15ET1 15ET6 20ET1 20ET6 10VT1 10VT3 15VT1 15VT6 20VT1 20VT6 Current Rating 3, 6, 10, 15 or 20A *IEC 60320-1 C14 inlet mates with C13 connector 80 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Performance RFI Filters for Switching Power Supplies (continued) T Series Electrical Schematics Case Styles 3 & 6A LINE T1 (3, 6, 10A) LOAD 1 B LINE LOAD RFI Power Line Filters D E A 10A C 15 & 20A LINE LOAD T1 (15 & 20A) E D B 2.00± .01 50.8± .25 Accessories GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord C A T3 Blue Blue Grn/Yel Brown B Brown A D E C 81 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Performance RFI Filters for Switching Power Supplies (continued) T Series Case Styles (continued) Case Dimensions T6 Part No. 3ET1, 6ET1 E D 3ET3, 6ET3 B 3ET7, 6ET7 10ET1, 10VT1 2.00 ± .01 50.8 ± .25 A C T7 10ET3, 10VT3 15ET1, 15VT1, 20ET1, 20VT1 15ET6, 15VT6, 20ET6, 20VT6 Tapped insert A B C D E D B E A C Recommended Panel Cutout .235 R 5.96 .157 Dia. 3.98 .910 23.1 1.295 32.89 1.575 40.01 82 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Performance RFI Filters for Switching Power Supplies (continued) T Series Performance Data Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) Typical Insertion Loss 1 Measured in closed 50 Ohm system 6ET 10ET 15ET db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0 0.01 0.1 1 10 30 Frequency in MHz 0 0.01 0.1 1 10 30 Frequency in MHz 0 10 0.01 0.1 1 0 10 30 Frequency in MHz 0.01 20ET 10VT 15VT 20VT db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0 0 0.1 1 10 30 Frequency in MHz 0.01 0.1 1 10 30 Frequency in MHz 0 0.1 1 10 30 Frequency in MHz 0.1 1 10 30 Frequency in MHz 80 40 0.01 RFI Power Line Filters 3ET 10 0.01 0.1 1 0 10 30 Frequency in MHz 0.01 Minimum Insertion Loss Measured in closed 50 Ohm system Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line) 83 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com