Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide EMI Power Inlet Filter EF Series EF8 UL Recognized CSA Certified VDE Approved* EF1F / EF1FC EF4 EF2F EF Series Specifications • Compact single stage EMI filter with IEC 60320-1 C14 inlet • Two element circuit provides basic attenuation Maximum leakage current each Line to Ground: @ 120 VAC 60 Hz: .21 mA @250 VAC 50 Hz: .36 mA • Available with an internal ground-circuit inductor (C suffix versions) to isolate equipment chassis from power line ground at radio frequencies Hipot rating (one minute): Line to Ground: Line to Line: • Superseded by the EEA Series Rated Voltage (max.): 250 VAC Operating Frequency: 50/60 Hz Ordering Information 3 EF 1F C 2250 VDC 1450 VDC Rated Current: 1 to 15A* Operating Ambient Temperature Range (at rated current Ir): -10°C to +40°C In an ambient temperature (Ta) higher than +40°C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 Ground Circuit Inductor Omit if none Output Styles 1F – .250 [6.3] spade terminals Accessories GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord (back) 2F – .250 [6.3] spade terminals (bottom) 4 – Wire leads (bottom) 8 – Wire leads (back) EF Series FA601: Insulating Shroud Current Rating 1, 3, 6, 10 or 15A .413 Dia. 10.5 .271 Dia. 6.9 Available Part Numbers 1EF1F 3EF1F 6EF1F 10EF1F 15EF1F 1EF2F 3EF2F 6EF2F 1EF4 3EF4 6EF4 Ground Circuit Inductor Versions 10EF1FC .118 3.0 1EF8 3EF8 6EF8 1.39 35.4 1.17 29.7 .767 19.5 *15A versions are tested by Underwriters Laboratories to US and Canadian requirements and are VDE approved at 10A, 250VAC 160 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide EMI Power Inlet Filter (continued) EF Series Electrical Schematic LINE LOAD EF8 1 F Blue Green/Yellow D E B Brown F Note 1: C Suffix (Ground Choke) Versions only A Case Styles EF1F & EF1FC C C D E A 3 B Case Dimensions C .65 Max. 16.5 A B EF4 C C 1EF2F, 3EF2F, 6EF2F 1EF4, 3EF4, 6EF4 1EF8, 3EF8, 6EF8 10EF1F, 10EF1FC 15EF1F E F .820 20.8 F 1.200 30.48 1.575 40.01 F Back Mount Blue Brown A Front Mount B D Recommended Panel Cutouts Green/Yellow D E B 1EF1F, 3EF1F, 6EF1F EF2F D E A Part No. Power Inlet Filters & Power Entry Modules .900 22.9 .140 3.56 .062 R. 1.58 Typ. 1.200 30.48 1.575 40.01 .140 3.56 .234 R. 5.94 Typ. Tolerances ± .005 [0.13] unless otherwise noted 161 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide EMI Power Inlet Filter (continued) EF Series Performance Data Typical Insertion Loss Measured in closed 50 Ohm system 1EF 3EF 6EF 10EF db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0 0.1 1 0 10 30 Frequency in MHz 0.1 1 10 30 Frequency in MHz 0 10 0.1 1 10 30 Frequency in MHz 0 0.1 1 10 30 Frequency in MHz 15EF db 100 90 80 70 Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) 60 50 40 30 20 10 0 0.01 0.1 1 10 30 Frequency in MHz Minimum Insertion Loss Measured in closed 50 Ohm system Common Mode / Asymmetrical (Line to Ground) 162 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com