MA-COM 3EH1

Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
Power Inlet Line Filter for Medical Equipment
H Series
UL Recognized
CSA Certified
VDE Approved*
EH8
EH9
EH4
EH1
H Series
EH5
Specifications
• Minimal leakage current suitable for medical
equipment
• Two element circuit provides basic EMI
attenuation above 1 MHz
• Available with an internal ground circuit inductor
(C suffix versions) to isolate equipment chassis
from power line ground at radio frequencies
• Capacitive output (see EAH, EBH and EJH Series
for capacitive input)
Ordering Information
3EH1C
Ground Circuit Inductor
Omit if none
Hipot rating (one minute):
Line to Ground:
Line to Line:
Rated Voltage (max.):
250 VAC
Operating Frequency:
50/60 Hz
Rated Current:
3 to 15A*
Operating Ambient Temperature Range
(at rated current Ir):
-10°C to +40°C
In an ambient temperature (Ta) higher than +40°C
the maximum operating current (Io) is calculated as
follows: Io = Ir (85-Ta)/45
Electrical Schematic
LINE
Output Styles
Chassis Mount Style
1 – .250 [6.3] spade terminals
3 – Wire leads
Power Inlet Style *
4 – .250 [6.3] spade terminals
(back)
5 – Wire leads (bottom)
8 – Wire leads (back)
9 – .250 [6.3] spade terminals
(bottom)
H Series
Leakage current designation
E – Low Leakage (<0.5 mA)
Current Rating
3, 6, 10 or 15A
3
2250 VDC
1450 VDC
Power Inlet Filters & Power Entry Modules
• Flanged mounting the same as the EC, ED and EF
Series
Maximum leakage current each Line to Ground:
@ 120 VAC 60 Hz:
2 A
@250 VAC 50 Hz:
5 A
LOAD
1
Note 1: 10EH4C version only
Available Part Numbers
3EH1
3EH3
6EH1
6EH3
6EH4
6EH5
6EH8
6EH9
10EH1
10EH3
10EH4
15EH4
Ground Circuit Inductor Versions
10EH4C
*15A versions are tested by Underwriters Laboratories
to US and Canadian requirements and are
VDE approved at 10A, 250VAC
*IEC 60320-1 C14 inlet mates with C13 connector
169
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
Power Inlet Line Filter for Medical Equipment
(continued)
H Series
Case Styles
H1 (Chassis Mount)
H5
E
A
Blue
Brown
D
D
E B
Green/Yellow
C
B
F
C
A



  


H3
F


 
(Chassis Mount)

 
H8
F
Blue
E D
B
Green/Yellow
D E
B
Brown
F
A
A


 
C

 
C


 
H4 & H4C

 
C
D
E




A
B
Recommended Panel Cutouts



Front Mount
.820
20.8
H9
1.200
30.48
1.575
40.01
C
.65 Max.
16.5
D
E




A
Back Mount
.900
22.9
.140
3.56 
.062
R.
1.58
Typ.
1.200
30.48
1.575
40.01
.140

3.56
.234
R.
5.94
Typ.
Tolerances ± .005 [0.13] unless otherwise noted
B







170
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
Power Inlet Line Filter for Medical Equipment
(continued)
H Series
Case Dimensions
Part No.
H1
H3
6EH4
10EH4,
10EH4C
15EH4
H5
H8
A
B
C
F




E

D






















































































Typical Insertion Loss
Measured in closed 50 Ohm system
3EH
6EH
db
100
db
100
90
90
80
80
70
70
60
60
50
50
40
40
30
30
20
20
10
0
10
0.01
0.1
1
0
10
30
Frequency in MHz
0.1
1
10
30
Frequency in MHz






10EH
15EH
db
100
db
100
90
90
80
80
70
70
60
60
50
50
40
40
30
30
20
20
10
10
0
3
Power Inlet Filters & Power Entry Modules
H9
Performance Data
0.1
1
0
10
30
Frequency in MHz
0.01
0.1
1
10
30
Frequency in MHz
Common Mode / Asymmetrical (L-G)
Differential Mode / Symmetrical (L-L)
Accessories
GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord
Minimum Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground)
FA601: Insulating Shroud
.413 Dia.
10.5
.271 Dia.
6.9
.118
3.0
1.39
35.4
1.17
29.7
 



  
































.767
19.5
171
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help