Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Performance Compact Power Line Filter RK Series UL Recognized CSA Certified VDE Approved 1 RFI Power Line Filters RK Series Specifications Maximum leakage current each Line to Ground: @ 120 VAC 60 Hz: 0.16 mA @250 VAC 50 Hz: 0.26 mA • Compact • Single stage • Chassis mount • Significant differential mode performance • Suitable for industrial machinery • Low input leakage current makes it suitable for portable equipment Hipot rating (one minute): Line to Ground: Line to Line: 2250 VDC 1450 VDC Rated Voltage (max): 250 VAC Operating Frequency: 50/60 Hz Rated Current: 3 to 20A Operating Ambient Temperature Range (at rated current Ir): -10°C to +40°C In an ambient temperature (Ta) higher than +40°C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 Ordering Information 10 E RK 1 Input / Output Style 1 – .250 [6.3] spade terminals Electrical Schematic RK Series Leakage current designation E – Low leakage (<0.5 mA) LINE LOAD Current Rating 3, 6, 10, 15 or 20A Available Part Numbers 3ERK1 10ERK1 20ERK1 6ERK1 15ERK1 65 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Performance Compact Power Line Filter (continued) RK Series Case Styles Case Dimensions Part No. RK1 (3 & 6A) B C 6ERK1 10ERK1, 15ERK1, 20ERK1 3ERK1 A E D C A D E B RK1 (10, 15 & 20A) A E D C B 66 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Performance Compact Power Line Filter (continued) RK Series Performance Data Typical Insertion Loss 1 Measured in closed 50 Ohm system 6RK 10RK 15RK db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0 0.01 0.1 1 10 30 Frequency in MHz 0 0.01 0.1 1 10 30 Frequency in MHz 0 RFI Power Line Filters 3RK 10 0.01 0.1 1 10 30 Frequency in MHz 0 0.01 0.1 1 10 30 Frequency in MHz 20RK db 100 90 80 70 Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) 60 50 40 30 20 10 0 0.01 0.1 1 10 30 Frequency in MHz Minimum Insertion Loss Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line) 67 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com