OMRON G5NB-1A

PCB Power Relay – G5NB-E
A Miniature Relay with 1-pole 5 A
Switching Capability and 10 kV
Impulse Withstand Voltage
■ ROHS compliant.
■ Highly efficient magnetic circuit for high
sensitivity (200 mW).
■ Compact, slim, yet provides 10 kV impulse
withstand voltage (between coil and contacts).
RC
■ Standard model conforms to UL, CSA and EN
standards.
■ Tracking resistance: CTI>250
Ordering Information
Classification
Standard
Contact form
SPST-NO
Enclosure ratings
Flux protection
Note: When ordering, add the rated coil voltage to the model number.
Example: G5NB-1A-E 12 VDC
Rated coil voltage
Model Number Legend
-E
1 2
3
1. Number of Poles
1:
1 pole
2. Contact Form
A:
SPST-NO
Application Examples
Water heaters, refrigerators, air conditioners, and small electric
appliances
48
3. Rated Coil Voltage
5, 12, 18, 24 VDC
Model
G5NB-1A
PCB Power Relay – G5NB-E
■
Power Relays
Specifications
Coil Ratings
Rated voltage
5 VDC
12 VDC
18 VDC
24 VDC
Rated current
40.0 mA
16.7 mA
11.1 mA
8.3 mA
Coil resistance
125 Ω
720 Ω
1,620 Ω
2,880 Ω
Must operate voltage
75% max. of rated voltage
Must release voltage
10% min. of rated voltage
Max. voltage
170% of rated voltage (at 23°C)
Power consumption
Approx. 200 mW
Note: The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
The operating characteristics are measured at a coil temperature of 23°C.
The “Max. voltage” is the maximum voltage that can be applied to the relay coil.
■
Contact Ratings
Load
Resistive load (cosφ = 1)
Rated load
5 A at 250 VAC, 3 A at 30 VDC
Max. switching voltage
250 VAC, 30 VDC
Max. switching current
5A
Max. switching power
1250 VA, 90 W
Failure rate (reference value)
10 mA at 5 VDC
Note: P level: λ60 = 0.1 x 10-6/operation (with an operating frequency of 120 operations/min)
■
Characteristics
Contact resistance (See note 2.)
100 mΩ max.
Operate time
10 ms max.
Release time
10 ms max.
Insulation resistance (See note 3.)
1,000 MΩ min. (at 500 VDC)
Dielectric strength
4,000 VAC, 50/60 Hz for 1 min between coil and contacts
750 VAC, 50/60 Hz for 1 min between contacts of same polarity
Impulse withstand voltage
10,000 V (1.2 x 50 ms) between coil and contacts
Vibration resistance
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Shock resistance
Destruction: 1,000 m/s2
Malfunction: 100 m/s2
Endurance
Mechanical: 5,000,000 operations min.
Electrical: 100,000 operations min (5 A at 250 VAC), 200,000 operations min. (3 A at 30 VDC)
Failure rate P level (reference value) 5 VDC, 10 mA
(See note 4.)
Ambient temperature
Operating: -40˚C to 85˚C (with no icing or condensation)
Ambient humidity
Operating: 5% to 85%
Weight
Approx. 4 g
Note: 1.
2.
3.
4.
The data shown above are initial value.
Measurement conditions: 5 VDC, 1 A, voltage drop method.
Measurement conditions: Measured at the same points as the dielectric strength using a 500-VDC ohmmeter.
This value is for a switching frequency of 120 operations/minute.
49
PCB Power Relay – G5NB-E
Approved Standards
UL508 (File No. 41515)
■
Coil ratings
5 to 24 VDC
Contact ratings
5 A, 30 VDC (resistive)
5 A, 125 VAC (resistive)
5 A, 250 VAC (general use)
CSA C22.2 (No. 0, No. 1, No. 14) (File No. LR31928)
Coil ratings
5 to 24 VDC
Contact ratings
5 A, 30 VDC (resistive)
5 A, 125 VAC (resistive)
5 A, 250 VAC (general use)
EN 61810-1 (VDE Reg No 137575)
Coil ratings
5 to 24VDC
■
Contact ratings
5 A, 30 VDC (resistive)
5 A, 250 VAC (general use)
Actual Load Life (Reference Values)
1. 120-VAC motor and lamp load (2.5-A surge and 0.5-A normal): 250,000 operations min.(at 23°C)
2. 160-VDC valve load (with varistor) (0.24-A): 250,000 operations min.(at 23°C)
50
PCB Power Relay – G5NB-E
Maximum Switching Capacity
Endurance
10
100
3
250 VAC, 30 VDC resistive load
No. of operations (x 104)
Contact current (A)
AC resistive
load
DC resistive
load
1
Contact
resistance
50
30
10
5
3
1
0.1
1
10
30
100
250
0
1,000
1
2
Contact voltage (V)
4
5
Malfunctioning Shock
G5NB-1A
Unconfirmed
area
3
Contact current (A)
Ambient Temperature vs. Maximum Coil Voltage
Maximum coil voltage (%)
Power Relays
Engineering Data
Test item:
G5NB-1A-E, 24 VDC
Quantity tested: 5
No current
3-A current
Y
1,000
700
1,000
X
Excited
Not excited
1,000
Z’
Quantity Tested: 5 units
Test Method: Shock was applied 3
times in 6 directions along 3 axes
and the level at which shock caused
malfunction was measured.
Rating: 100 m/s2
125
X’
1,000
Z
1,000
1,000
Y’
Ambient temperature (°C)
Unit: m/s2
Shock direction
X
X’
Y
Z
Z’
Y’
Dimensions
Note: All units are in millimeters unless otherwise indicated.
G5NB-1A-E
7.2 max.
(7.0)*
20.5 max.
(20.4)*
PCB Mounting Holes
(Bottom View)
Terminal Arrangement/
Internal Connections
(Bottom View)
Tolerance: ±0.1 mm
15. 3 max.
(15.0)*
Four, 1.1 dia.
3.4
0.4
0.27
11.5
0.33
7
(No coil polarity)
*Average value
Precautions
■
Correct Use
HANDLING
The enclosure rating of the G5NB is for flux protection. Do not use
immersion-cleaning.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
51