OMRON G5NB

PCB Relay
G5NB
A Slim Compact Relay with 3 A Switching
Capability and 10-kV Impulse Withstand
Voltage
• Max size 20.5L x 7.2 W x 15.3 W mm.
• Standard models switch up to 3 A
High-capacity models switch up to 5 A (AC loads only).
• Low power consumption (200 mW).
• Semi-sealed and sealed types available.
• UL recognized / CSA certified. VDE Approved.
• RoHS Compliant.
RC
Ordering Information
Contact Form SPST-NO
Enclosure ratings
Classification
Flux-tight model
Sealed model
Standard
G5NB-1A
G5NB-1A4
High Capacity
G5NB-1A-E
G5NB-1A4-E
2
4
5
■ Model Number Legend
4
5
1. Number of Poles
1:
1 pole
2. Contact Form
A:
SPST-NO
3. Enclosure Ratings
None: Flux protection
4:
Sealed
4. Type
None: Standard
E:
High Capacity
5. Rated Coil Voltage
5, 12, 18, 24 VDC
Application Examples
Water heaters, refrigerators, air conditioners, and small electric appliances
PCB Relay
G5NB
137
Specifications
■ Coil Ratings
Rated voltage
5 VDC
12 VDC
18 VDC
Rated current
40.0 mA
16.7 mA
11.1 mA
24 VDC
8.3 mA
Coil resistance
125 Ω
720 Ω
1,620 Ω
2,880 Ω
Must operate voltage
75% of rated voltage (max.)
Must release voltage
10% of rated voltage (min.)
Max. voltage
Standard: 180% of rated voltage (at 23°C)
High-capacity: 170% of rated voltage (at 23°C)
Power consumption
Approx. 200 mW
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2. The operating characteristics are measured at a coil temperature of 23°C.
3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil.
■ Contact Ratings
Load
Standard
High-capacity
Rated load (resistive, p.f.= 1)
3 A at 125 VAC
3 A at 30 VDC
5 A at 250 VAC
3 A at 30 VDC
Max. switching voltage
250 VAC, 30 VDC
250 VAC, 30 VDC
Rated carry current
Max. switching current
3A
3A
5A
5A (AC load,) 3A (DC load)
Max. switching power
375 VA, 90 W
1,250 VA, 90 W
■ Characteristics
Contact resistance (see note 2)
100 mΩ max.
Operate time
10 ms max.
Release time
10 ms max.
Insulation resistance (see note 3)
1,000 MΩ min. (at 500 VDC)
Dielectric strength
4,000 VAC, 50/60 Hz for 1 min. between coil and contacts
750 VAC, 50/60 Hz for 1 min. between contacts of same polarity
Impulse withstand voltage
10,000 V (1.2 x 50 μs) between coil and contacts
Vibration resistance
Destruction:
Malfunction:
10 to 55 Hz, 1.5-mm double amplitude
10 to 55 Hz, 1.5-mm double amplitude
Shock resistance
Destruction:
Malfunction:
1,000 m/s2 (approx. 100 G)
100 m/s2 (approx. 10 G)
Life expectancy
Mechanical:
5,000,000 operations min. (18,000 operations/hour)
Electrical:
200,000 operations minimum:
High-capacity
5 A at 125 VAC
3 A at 30 VDC
Standard
3 A at 125 VAC
3 A at 30 VDC
100,000 operations minimum:
High-capacity
5 A at 250 VAC
All electrical load ratings are resistive, with operation frequency = 1,800 operations/hour.
Minimum permissible load
(reference value) (see note 4)
5 VDC, 10 mA
Ambient temperature
Operating: –40°C to 70°C (with no icing or condensation)
Ambient humidity
Operating: 5% to 85%
Weight
Approx. 4 g
Note: 1.
2.
3.
4.
138
The data shown above are initial value.
Measurement conditions: 5 VDC, 1 A, voltage drop method
Measurement conditions: Measured at the same points as the dielectric strength using a 500-VDC ohmmeter.
This value is for a switching frequency of 120 operations/minute. (P level: λ60 = 0.1 x 10-6 operations)
PCB Relay
G5NB
■ Approved Standards
UL Recognized (File No. E41515)
Coil ratings
Contact ratings
5 to 24 VDC
3 A at 30 VDC (Resistive), 70°C
3 A at 125 VAC (Resistive), 70°C
CSA Certified (File No. LR31928)
Coil ratings
Contact ratings
5 to 24 VDC
3 A at 30 VDC (Resistive)
3 A at 125 VAC (Resistive)
■ Actual Load Life (Reference Values)
1. 120-VAC motor and lamp load (2.5-A surge and 0.5-A normal): 250,000 operations min. (at 23°C)
2. 160-VDC valve load (with varistor) (0.24-A): 250,000 operations min. (at 23°C)
Engineering Data
Standard models
Maximum Switching Capacity
Electrical Service Life
10
100
3
AC resistive
load
DC resistive
load
1
Contact
resistance
0.1
1
Service Life ( 104 operations)
Switching current (A)
125 VAC, 30 VDC resistive load
50
30
10
5
3
1
10
30
100
250
1,000
Switching voltage (V)
0
1
2
3
4
Contact current (A)
High-capacity models
Electrical Service Life
PCB Relay
G5NB
139
Standard models
High-capacity models
Ambient Temperature vs. Maximum Coil Voltage
Maximum coil voltage (%)
220
Unconfirmed
area
200
Test item:
G5NB-1A, 24 VDC
Quantity tested: 5
No current
3-A current
180
160
140
120
100
80
0
20 23
40
60
70
80
100
Ambient temperature (°C)
Note: The maximum coil voltage refers to the maximum value in a varying range of operating power voltage, not a continuous voltage.
All models
Malfunctioning Shock
G5NB-1A
Y
1,000
Excited
Not excited
700
1,000
X
Quantity Tested: 5 units
1,000
Z'
Test Method: Shock was applied 3
times in 6 directions along 3 axes
and the level at which shock caused
malfunction was measured.
Rating: 100 m/s2
125
X'
1,000
Z
1,000
1,000
Y'
Unit: m/s2
Shock direction
X
X'
Y
Z
Z'
Y'
Dimensions
Note: All units are in millimeters unless otherwise indicated.
G5NB-1A(4)(-E)
7.2 max.
(7.0)*
20.5 max.
(20.4)*
PCB Mounting Holes
(Bottom View)
Terminal Arrangement/
Internal Connections
(Bottom View)
Tolerance: ±0.1 mm
15. 3 max.
(15.0)*
Four, 1.1 dia.
3.4
0.4
0.27
11.5
0.33
7
(No coil polarity)
*Average value
Precautions
■ Correct Use
Handling
Note: 1. The enclosure rating for G5NB-1A and G5NB-1A-E is suitable for flux protection. Do not use immersion-cleaning for these model
2. Do not ultrasonic clean any G5NB relay.
140
PCB Relay
G5NB
MEMO
PCB Relay
G5NB
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which
can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
OMRON ON-LINE
OMRON ELECTRONIC
COMPONENTS LLC
55 E. Commerce Drive, Suite B
Schaumburg, IL 60173
Global - http://www.omron.com
USA - http://www.components.omron.com
847-882-2288
Cat. No. X301-E-1b
PCB Relay
09/11
G5NB
Specifications subject to change without notice
Printed in USA