PCB Relay G5V-2 Miniature Relay for Signal Circuits ■ ■ ■ ■ ■ Wide switching power of 10 µA to 2 A. High dielectric strength coil-contacts:1,000 VAC; open contacts: 750 VAC. Conforms to FCC Part 68 requirements. Ag + Au clad bifurcated crossbar contacts and fully sealed for high contact reliability. New 150-mW relays with high-sensitivity. RC FCC Ordering Information Classification Contact form Standard DPDT Contact type Bifurcated crossbar Contact material Ag + Au-clad Enclosure ratings Fully sealed Model G5V-2 High-sensitivity G5V-2-H1 Note: When ordering, add the rated coil voltage to the model number. Example: G5V-2 12 VDC Rated coil voltage Model Number Legend G5V - 1 VDC 2 3 2. Classification H1: High-sensitivity 1. Contact Form 2: DPDT 3. Rated Coil Voltage 3, 5, 6, 9, 12, 24, 48 VDC Specifications ■ Coil Ratings Standard Models Rated voltage 3 VDC 5 VDC 6 VDC 9 VDC 12 VDC 24 VDC 48 VDC Rated current 166.7 mA 100 mA 83.3 mA 55.6 mA 41.7 mA 20.8 mA 12 mA Coil resistance Coil inductance (H) (ref. value) 18 W 50 W 72 W 162 W 288 W 1,152 W 4,000 W Armature OFF 0.04 0.09 0.16 0.31 0.47 1.98 7.23 Armature ON 0.05 0.11 0.19 0.49 0.74 2.63 10.00 Must operate voltage 75% max. of rated voltage Must release voltage 5% min. of rated voltage Max. voltage 120% of rated voltage at 23°C Power consumption Approx. 500 mW 1 Approx. 580 mW G5V-2 G5V-2 High Sensitivity Models Rated voltage 3 VDC 5 VDC 6 VDC 9 VDC 12 VDC 24 VDC 48 VDC Rated current 50 mA 30 mA 25 mA 16.7 mA 12.5 mA 8.33 mA 6.25 mA Coil resistance Coil inductance (H) (ref. value) 60 W 166.7 W 240 W 540 W 960 W 2,880 W 7,680 W Armature ON 0.18 0.46 0.70 1.67 2.90 6.72 20.1 Armature OFF 0.57 0.71 0.97 2.33 3.99 9.27 26.7 Must operate voltage 75% max. of rated voltage Must release voltage 5% min. of rated voltage Max. voltage 180% of rated voltage at 23°C Power consumption Approx. 150 mW Note: ■ 150% of rated voltage at 23°C Approx. 200 mW 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. 2. Operating characteristics are measured at a coil temperature of 23°C. Contact Ratings Item Standard models High sensitivity models Load Resistive load (cosf = 1) Rated load 0.5 A at 125 VAC; 2 A at 30 VDC Contact material Ag + Au-clad Rated carry current 2A Max. switching voltage 125 VAC, 125 VDC Max. switching current 2A 1A Max. switching power 62.5 VA, 60 W 62.5 VA, 24 W Failure rate (reference value) 0.01 mA at 10 mVDC Note ■ Approx. 300 mW 0.5 A at 125 VAC; 1 A at 24 VDC Note:P level: l60 = 0.1 x 10–6/operation Characteristics Item Standard models High sensitivity models Contact resistance 50 mW max. Operate time 7 ms max. Release time 3 ms max. Bounce time Operate: approx. 0.3 ms Release: approx. 1.5 ms Max. operating frequency Mechanical: 36,000 operations/hr Electrical: 1,800 operations/hr (under rated load) Insulation resistance 1,000 MW min. (at 500 VDC) Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between coil and contacts 1,000 VAC, 50/60 Hz for 1 min between contacts of different polarity 750 VAC, 50/60 Hz for 1 min between contacts of same polarity 100 mW max. 1,000 VAC, 50/60 Hz for 1 min between coil and contacts 1,000 VAC, 50/60 Hz for 1 min between contacts of different polarity 500 VAC, 50/60 Hz for 1 min between contacts of same polarity Impulse withstand voltage 1,500 V (10 x 160 µs) between coil and contacts (conforms to FCC Part 68) Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) Shock resistance Destruction: 1,000 m/s2 (approx. 100G) Malfunction: 200 m/s2 (approx. 20G) Endurance Mechanical: 15,000,000 operations min. (at 36,000 operations/hr) Electrical: 100,000 operations min. (at 1,800 operations/hr) Ambient temperature Operating: -25°C to 65°C (with no icing) Ambient humidity Operating: 5% to 85% Weight Approx. 5 g Destruction: 1,000 m/s2 (approx. 100G) Malfunction: 100 m/s2 (approx. 10G) Operating: -25°C to 70°C (with no icing) 2 G5V-2 ■ G5V-2 Approved Standards UL478, UL1950, UL508 (File No. E41515)/CSA C22.2 No.0, No.14 (File No. LR24825) Contact form Coil ratings Contact ratings G5V-2 DPDT 3 to 48 VDC G5V-2-H1 0.6 A, 125 VAC (general use) 0.6 A, 110 VDC (resistive load) 2 A, 30 VDC (resistive load) 0.5 A, 125 VAC (general use) 0.2 A, 110 VDC (resistive load) 1 A, 24 VDC (resistive load) Engineering Data Maximum Switching Power Endurance G5V-2 G5V-2 Ambient Temperature vs. Maximum Coil Voltage 30-VDC resistive load 125-VAC resistive load 1 Switching voltage (V) G5V-2-H1 G5V-2-H1 1000 0.7 0.5 DC resistive load 0.2 0.1 0 Switching voltage (V) 500 200 24-VDC resistive load 300 100 125-VAC resistive load 50 30 10 Maximum coil voltage (%) 1 Life expectancy (x10 3 operations) AC resistive load 48 VDC 3 G5V-2-H1 3 Switching current (A) 2 Coil rated voltage 3 to 24 VDC Switching current (A) Ambient temperature (°) Note: The maximum coil voltage refers to the maximum value in a varying range of operating power voltage, not a continuous voltage. 5 0.3 Maximum coil voltage (%) AC resistive load DC re sistive load Endurance (x10 3 operations) Switching current (A) G5V-2 3 to 24 VDC 180 160 140 48 VDC 120 100 80 0 Switching current (A) Ambient temperature (°) Note: The maximum coil voltage refers to the maximum value in a varying range of operating power voltage, not a continuous voltage. 3 G5V-2 G5V-2 Dimensions Note: 1. All units are in millimeters unless otherwise indicated. 2. Orientation marks are indicated as follows: Terminal Arrangement/ Internal Connections (Bottom View) 1 8 4 6 13 11 Mounting Holes (Bottom View) Tolerance: ±0.1 (1.3) 7.62 5.08 5.08 (1.2) 10.1 max. 9.9 typ. 20.5 max. 20.3 typ. 7.62 16 11.5 max. 11.4 typ. 9 (1.3) Eight, 1-dia. holes 0.5 0.5 0.3 7.62 3.5 ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. K046-E1-2B 4