OMRON G5V-2-H1-9VDC

PCB Relay
G5V-2
Miniature Relay for Signal Circuits
■
■
■
■
■
Wide switching power of 10 µA to 2 A.
High dielectric strength coil-contacts:1,000 VAC;
open contacts: 750 VAC.
Conforms to FCC Part 68 requirements.
Ag + Au clad bifurcated crossbar contacts and
fully sealed for high contact reliability.
New 150-mW relays with high-sensitivity.
RC FCC
Ordering Information
Classification
Contact form
Standard
DPDT
Contact type
Bifurcated crossbar
Contact material
Ag + Au-clad
Enclosure ratings
Fully sealed
Model
G5V-2
High-sensitivity
G5V-2-H1
Note: When ordering, add the rated coil voltage to the model number.
Example: G5V-2 12 VDC
Rated coil voltage
Model Number Legend
G5V -
1
VDC
2
3
2. Classification
H1: High-sensitivity
1. Contact Form
2: DPDT
3. Rated Coil Voltage
3, 5, 6, 9, 12, 24, 48 VDC
Specifications
■
Coil Ratings
Standard Models
Rated voltage
3 VDC
5 VDC
6 VDC
9 VDC
12 VDC
24 VDC
48 VDC
Rated current
166.7 mA
100 mA
83.3 mA
55.6 mA
41.7 mA
20.8 mA
12 mA
Coil resistance
Coil inductance
(H) (ref. value)
18 W
50 W
72 W
162 W
288 W
1,152 W
4,000 W
Armature OFF
0.04
0.09
0.16
0.31
0.47
1.98
7.23
Armature ON
0.05
0.11
0.19
0.49
0.74
2.63
10.00
Must operate voltage
75% max. of rated voltage
Must release voltage
5% min. of rated voltage
Max. voltage
120% of rated voltage at 23°C
Power consumption
Approx. 500 mW
1
Approx.
580 mW
G5V-2
G5V-2
High Sensitivity Models
Rated voltage
3 VDC
5 VDC
6 VDC
9 VDC
12 VDC
24 VDC
48 VDC
Rated current
50 mA
30 mA
25 mA
16.7 mA
12.5 mA
8.33 mA
6.25 mA
Coil resistance
Coil inductance
(H) (ref. value)
60 W
166.7 W
240 W
540 W
960 W
2,880 W
7,680 W
Armature ON
0.18
0.46
0.70
1.67
2.90
6.72
20.1
Armature OFF
0.57
0.71
0.97
2.33
3.99
9.27
26.7
Must operate voltage
75% max. of rated voltage
Must release voltage
5% min. of rated voltage
Max. voltage
180% of rated voltage at 23°C
Power consumption
Approx. 150 mW
Note:
■
150% of rated
voltage at
23°C
Approx.
200 mW
1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2. Operating characteristics are measured at a coil temperature of 23°C.
Contact Ratings
Item
Standard models
High sensitivity models
Load
Resistive load (cosf = 1)
Rated load
0.5 A at 125 VAC; 2 A at 30 VDC
Contact material
Ag + Au-clad
Rated carry current
2A
Max. switching voltage
125 VAC, 125 VDC
Max. switching current
2A
1A
Max. switching power
62.5 VA, 60 W
62.5 VA, 24 W
Failure rate (reference value)
0.01 mA at 10 mVDC
Note
■
Approx.
300 mW
0.5 A at 125 VAC; 1 A at 24 VDC
Note:P level: l60 = 0.1 x 10–6/operation
Characteristics
Item
Standard models
High sensitivity models
Contact resistance
50 mW max.
Operate time
7 ms max.
Release time
3 ms max.
Bounce time
Operate: approx. 0.3 ms
Release: approx. 1.5 ms
Max. operating frequency
Mechanical: 36,000 operations/hr
Electrical: 1,800 operations/hr (under rated load)
Insulation resistance
1,000 MW min. (at 500 VDC)
Dielectric strength
1,000 VAC, 50/60 Hz for 1 min between coil
and contacts
1,000 VAC, 50/60 Hz for 1 min between contacts of different polarity
750 VAC, 50/60 Hz for 1 min between contacts
of same polarity
100 mW max.
1,000 VAC, 50/60 Hz for 1 min between coil
and contacts
1,000 VAC, 50/60 Hz for 1 min between contacts of different polarity
500 VAC, 50/60 Hz for 1 min between contacts
of same polarity
Impulse withstand voltage
1,500 V (10 x 160 µs) between coil and contacts (conforms to FCC Part 68)
Vibration resistance
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Shock resistance
Destruction: 1,000 m/s2 (approx. 100G)
Malfunction: 200 m/s2 (approx. 20G)
Endurance
Mechanical: 15,000,000 operations min. (at 36,000 operations/hr)
Electrical: 100,000 operations min. (at 1,800 operations/hr)
Ambient temperature
Operating: -25°C to 65°C (with no icing)
Ambient humidity
Operating: 5% to 85%
Weight
Approx. 5 g
Destruction: 1,000 m/s2 (approx. 100G)
Malfunction: 100 m/s2 (approx. 10G)
Operating: -25°C to 70°C (with no icing)
2
G5V-2
■
G5V-2
Approved Standards
UL478, UL1950, UL508 (File No. E41515)/CSA C22.2 No.0, No.14 (File No. LR24825)
Contact form
Coil ratings
Contact ratings
G5V-2
DPDT
3 to 48 VDC
G5V-2-H1
0.6 A, 125 VAC (general use)
0.6 A, 110 VDC (resistive load)
2 A, 30 VDC (resistive load)
0.5 A, 125 VAC (general use)
0.2 A, 110 VDC (resistive load)
1 A, 24 VDC (resistive load)
Engineering Data
Maximum Switching Power
Endurance
G5V-2
G5V-2
Ambient Temperature vs.
Maximum Coil Voltage
30-VDC
resistive
load
125-VAC resistive
load
1
Switching voltage (V)
G5V-2-H1
G5V-2-H1
1000
0.7
0.5
DC resistive load
0.2
0.1
0
Switching voltage (V)
500
200
24-VDC resistive load
300
100
125-VAC resistive load
50
30
10
Maximum coil voltage (%)
1
Life expectancy (x10 3 operations)
AC resistive
load
48 VDC
3
G5V-2-H1
3
Switching current (A)
2
Coil rated voltage
3 to 24 VDC
Switching current (A)
Ambient temperature (°)
Note: The maximum coil voltage refers to the maximum value in a varying range of operating
power voltage, not a continuous voltage.
5
0.3
Maximum coil voltage (%)
AC resistive load
DC re
sistive
load
Endurance (x10 3 operations)
Switching current (A)
G5V-2
3 to 24 VDC
180
160
140
48 VDC
120
100
80
0
Switching current (A)
Ambient temperature (°)
Note: The maximum coil voltage refers to the maximum value in a varying range of operating
power voltage, not a continuous voltage.
3
G5V-2
G5V-2
Dimensions
Note:
1. All units are in millimeters unless otherwise indicated.
2. Orientation marks are indicated as follows:
Terminal Arrangement/
Internal Connections
(Bottom View)
1
8
4
6
13
11
Mounting Holes
(Bottom View)
Tolerance: ±0.1
(1.3)
7.62
5.08 5.08
(1.2)
10.1 max.
9.9 typ.
20.5 max.
20.3 typ.
7.62
16
11.5 max.
11.4 typ.
9
(1.3)
Eight, 1-dia. holes
0.5
0.5
0.3
7.62
3.5
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.