DBLECTRO SBU100

SBU100 SERIES
100W Open Frame Switching Power Supplies For I.T.E.
Description:
The SBU100 series of compact, open frame constructed, AC/DC
switching mode power supplies provide 100 Watts of continuous output
power .They are suited for use in based systems, portable equipments
and many other applications. All models meet FCC Part-15 class B and
CISPR-22 class B emission Limits and are designed to comply with
UL/c-UL(UL 60950-1:2ndEdition),TUV/Bauart(EN 60950-1:2ndEdition)
and new CE requirements. All units are 100% burned in and tested.
Features:
Wide Operating Voltage 90 to 260 VAC,47 to 63 Hz
Internal EMI filter
Single Output
Input connector mates with Molex housing 09-50-3051 and
Molex 2478 series crimp terminal
Output connector mates with Molex housing 09-50-3131 and
Molex 2478 series crimp terminal
Input Surge Current, Over Voltage and Over Load protection
Over Voltage Protection (Crowbar Design)
Active Power Factor Correction
Size: 3"x5"x1.18"
Class I
2 year warranty
Safety Approvals :
BAUART
GEPRUFT
Product Safety
CB
TYPE
APPROVED
Electrical Characteristics:
Sym.
Vin
fin
*
Parameter
Test Conditions
Min. Typ. Max. Unit
Safety Approvals Input
Voltage Range
100
240
VAC
Operate Voltage Range
90
260
VAC
Input Frequency
47
63
Hz
PF
Power Factor Correction
Io=Full load, Vin=90~260VAC
Po
Output Power Range
Vin=90 to 260 VAC
Vo
Output Voltage Range
See rating Chart
V
Io
Output Current Range
See rating Chart
A
0.95 0.97 1.0
100
0
W
Iil
Input Current (Low Line)
Io=Full load, Vin=115VAC
1.6
Iih
Input Current (High Line)
0.8
A
A
I rl
Low Line Inrush Current
I rh
High Line Inrush Current
Eff
Efficiency
Io=Full load,
Io=Full load,
Vin=115VAC
Io=Full load,
Vin=230VAC
Io=Full load,
Vin=230VAC
25 C,Cool start,
44
50
A
25 C,Cool start,
88
100
A
80
85
%
REG-i
Line Regulation
Io=Full load
REG -o
Load Regulation
0.5
1
%
3
5
%
OVP
Over Voltage Protection
112
132
%
OCP
Over Current Protection
110
150
%
Ttr
Time of Transient Response Io=Full load to Half Load, Vin=100VAC
4
mS
Vin=230VAC
70
Vin=230VAC
Thold
Hold-Up Time
Io=Full load, Vin=110VAC
Ts
Start Up Time
Io=Full load, Vin=100VAC
mS
16
2
Vp-p
Ripple & Noise (Peak to Peak) Full load, Vin=90VAC
0.5
Ilk
Safety Ground Leakage Current
Io=Full load, Vin=240VAC
0.5 0.75
TC
Temperature
All output
Coefficient
-0.04
1
S
%
mA
0.04
%/ C
Min. Typ. Max.
Unit
50
C
C
%
%
Hrs
*
Environmental :
Note: The Ripple & Noise which is under 3.3VDC at 2% max
Sym.
Toper
Tstg
Ho
Hr
MTBF
Pd
Parameter
T e s t Conditions
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Operating Temperature at 25 C, Calculated per MIL-HDBK-217F
Derate linearly from 100% load at 50 C to 50% load at 70 C
0
-40
0
0
0.1M
70
85
95
75
SBU100 SERIES
100W Open Frame Switching Power Supplies For I.T.E.
Safety Specifications:
Sym.
Vps
Vpg
Ris
Parameter
CISPR EMI requirements for CISPR-22
FCC
Min. Typ. Max.
Unit
Primary to secondary
4242
VDC
Primary to ground
2121
VDC
T e s t Conditions
Dielectric Withstanding Voltage
for Primary to secondary
Dielectric Withstanding Voltage
for Primary to Ground
Isolation Resistance
EMI requirements for FCC PART-15
M
Test Voltage=500VDC
50
Vin=220VAC
B
CLASS
Vin=110VAC
B
CLASS
Output Voltage And Current Rating Chart (Single Output) :
Model Number
Output Voltage
Output Current
Total Regulation
Maximum
Output Power
SBU100-101
3 ~
5
VDC
18.00 ~ 10.80
A
5%
54W
SBU100-102
5 ~
6
VDC
14.00 ~ 11.66
A
5%
70W
SBU100-103
6 ~
9
VDC
13.33 ~
8.88
A
5%
80W
SBU100-104
9 ~ 11
VDC
11.11 ~
9.09
A
5%
100W
SBU100-105
11 ~ 13
VDC
9.09 ~
7.69
A
3%
100W
SBU100-106
13 ~ 16
VDC
7.69 ~
6.25
A
3%
100W
SBU100-107
16 ~ 21
VDC
6.25 ~
4.76
A
3%
100W
SBU100-108
21 ~ 27
VDC
4.76 ~
3.70
A
2%
100W
SBU100-109
27 ~ 33
VDC
3.70 ~
3.03
A
2%
100W
SBU100-110
33 ~ 40
VDC
3.03 ~
2.50
A
2%
100W
SBU100-111
40 ~ 50
VDC
2.50 ~
2.00
A
2%
100W
PIN CHART
PIN
MODEL
1
2
3
4
5
6
7
8
9 10 11 12 13
SBU100-1XX-13PIN OUT OUT OUT OUT OUT OUT RTN RTN RTN RTN RTN RTN N/C
Mechanical Specifications :
Note:
1. Dimensions are shown in inches or mm.
2. Weight: 345gs approx.
3. Input connector mates with Molex housing 09-50-3051
and Molex 2478 series crimp terminal.
4. Output connector mates with Molex housing 09-50-3131
and Molex 2478 series crimp terminal.