Series AMER120-CAZ up to 5A | AC-DC / DC-DC | LED Driver / Converter FEATURES: Constant Current or Constant Voltage LED Driver or Converter Input range 90-305VAC/47-440Hz High Efficiency up to 91% 115VAC Operating temperature -50 to 85°C 230VAC Operating temperature -55 to 85°C Dimming via analog / 0-10V dimming ② Models Single output Max Output Power (W) ① Output Voltage ③ Range (V) AMER120-50250CAZ 125 36-50 AMER120-36340CAZ 122.4 AMER120-24500CAZ 120 Model Output Current ③ (A) Over Temperature Protection Over Current Protection Waterproof Case rated IP68 Power Factor Correction Short Circuit Protection Input Voltage (VAC/Hz) Input Voltage (VDC) 0-2.5 90-305/47-440 120-430 24-36 0-3.4 90-305/47-440 120-430 12-24 0-5 90-305/47-440 120-430 Mode of Operation Efficiency (%) Constant Current 91 90 90 89 89 87 Constant Voltage ② Constant Current Constant Voltage ② Constant Current Constant Voltage ② Add Suffix “-F” No dimming option Exceeding the maximum output power will permanently damage the converter ② The dimming feature is not supported when units are used in Constant Voltage mode only, Aimtec suggests to order “-F” No dimming option in this case. ③ In constant current mode output current is maximum shown, in constant voltage mode output voltage is the maximum shown. NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. ① Input Specifications Parameters Inrush current <2ms Leakage current AC current Power Factor External fuse Start up time Surge voltage Conditions Typical 115VAC 230VAC 115VAC 230VAC 115VAC 230VAC 115VAC 240VAC 45 60 0.5 0.75 1.8 0.7 Maximum Units A mA A 0.98 0.94 250V/3A 900 2sec 440 ms V Maximum Units Output Specifications Parameters Current accuracy Line regulation Load regulation ④ Ripple & Noise Hold-up time Current adjustment range Minimum Load Voltage ④ Conditions Typical LL-HL 0-100% load 20MHz Bandwidth ±3 ±1 ±3 100 % % % mV p-p 80 100-0 ms % See the models table Tested with 0.1µF (M/C) or (C/C) and 47µF (E/C) parallel capacitors at the end. www.aimtec.com F 052.1e R3.D Tel: +1 514 620 2722 1 of 10 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMER120-CAZ up to 5A | AC-DC / DC-DC | LED Driver / Converter Isolation Specifications Parameters Conditions Tested I/P-O/P voltage Tested I/P-FG voltage Tested O/P-FG voltage Isolation Resistance Isolation Capacitance Typical 3sec 3sec 3sec 500VDC Rated Units 3750 1880 500 VAC VAC VAC MΩ pF >1000 1000 General Specifications Parameters Conditions Switching frequency Over current protection Over voltage protection Short circuit protection Short circuit restart Over temperature protection Operating temperature (See Derating Table) Cold Start-up Time Maximum case temperature Storage temperature Temperature coefficient Cooling Humidity Case material Potting Wires Weight Dimensions (L X H X W) MTBF Typical Maximum 100 110% of Iout 110% of Vout Continuous Auto recovery >105°C -50 to +85 -55 to +85 (115VAC) (230VAC) -55°C Units KHz o 30 100 C C Sec o C o C % / oC 95 % RH o -55 to +95 ±0.02 Free air convection Aluminum Epoxy (IP68 rated) UL1015 18AWG Input & 14AWG Output *20CM 750 7.13 x 2.32 x 1.85 inches 181.00 x 59.00 x 47.00 mm >400,000 hrs (MIL-HDBK-217F at +25°C) g Safety Specifications Parameters Agency approvals Standards www.aimtec.com F 052.1e R3.D CE EN55022, class B, EN60529(IP68), EN61347-1, EN61347-2-13 NOTE : also designed to meet cULus, UL8750, UL60950-1 Tel: +1 514 620 2722 2 of 10 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMER120-CAZ up to 5A | AC-DC / DC-DC | LED Driver / Converter Dimensions Analog (resistive) Dimming Application Circuit Model Number AMER120-50250CAZ AMER120-36340CAZ AMER120-24500CAZ www.aimtec.com F 052.1e R3.D Tel: +1 514 620 2722 3 of 10 Maximum Pot Value (kΩ) 18.22 22.10 34.31 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMER120-CAZ up to 5A | AC-DC / DC-DC | LED Driver / Converter 0-10V Dimming Application Circuit Derating Free Air Convection CV mode CC Mode 50°C 50°C 100 Output Power (%) 230 VAC 80 60 Safe Operating Area 40 20 - 55 85°C 80°C 0 - 30 0 20 40 60 80 100 Ambient Temperature º C www.aimtec.com F 052.1e R3.D Tel: +1 514 620 2722 4 of 10 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMER120-CAZ up to 5A | AC-DC / DC-DC | LED Driver / Converter Efficiency vs. Input Voltage and Output Current (CC Load) AMER120-50250CAZ AMER120-36340CAZ www.aimtec.com F 052.1e R3.D Tel: +1 514 620 2722 5 of 10 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMER120-CAZ up to 5A | AC-DC / DC-DC | LED Driver / Converter Efficiency vs. Input Voltage and Output Current (CC Load) Continued AMER120-24500CAZ PFC Value vs. Output Load Current (CC Load) AMER120-50250CAZ www.aimtec.com F 052.1e R3.D Tel: +1 514 620 2722 6 of 10 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMER120-CAZ up to 5A | AC-DC / DC-DC | LED Driver / Converter PFC Value vs. Output Load Current (CC Load) AMER120-36340CAZ AMER120-24500CAZ www.aimtec.com F 052.1e R3.D Tel: +1 514 620 2722 7 of 10 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMER120-CAZ up to 5A | AC-DC / DC-DC | LED Driver / Converter Constant Current Mode vs. Constant Voltage Mode AMER120-50250CAZ AMER120-36340CAZ www.aimtec.com F 052.1e R3.D Tel: +1 514 620 2722 8 of 10 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMER120-CAZ up to 5A | AC-DC / DC-DC | LED Driver / Converter Constant Current Mode vs. Constant Voltage Mode AMER120-24500CAZ Output Current vs. Radj AMER120-50250CAZ www.aimtec.com F 052.1e R3.D Tel: +1 514 620 2722 9 of 10 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMER120-CAZ up to 5A | AC-DC / DC-DC | LED Driver / Converter Output Current vs. Radj AMER120-36340CAZ AMER120-24500CAZ NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 052.1e R3.D Tel: +1 514 620 2722 10 of 10 Toll free: + 1 888 9 AIMTEC (924 6832) North America only