AVAGO APDS-9930

APDS-9930
Digital Proximity and Ambient Light Sensor
Data Sheet
Description
Features
The APDS-9930 provides digital ambient light sensing
(ALS), IR LED and a complete proximity detection system
in a single 8 pin package. The proximity function offers
plug and play detection to 100 mm (without front glass)
thus eliminating the need for factory calibration of the
end equipment or sub-assembly. The proximity detection
feature operates well from bright sunlight to dark rooms.
The wide dynamic range also allows for operation in short
distance detection behind dark glass such as a cell phone.
In addition, an internal state machine provides the ability
to put the device into a low power mode in between
ALS and proximity measurements providing very low
average power consumption. The ALS provides a photopic
response to light intensity in very low light condition or
behind a dark faceplate.
ALS, IR LED and Proximity Detector in an Optical Module
The APDS-9930 is particularly useful for display management with the purpose of extending battery life and
providing optimum viewing in diverse lighting conditions.
Display panel and keyboard backlighting can account for
up to 30 to 40 percent of total platform power. The ALS
features are ideal for use in notebook PCs, LCD monitors,
flat-panel televisions, and cell phones.
The proximity function is targeted specifically towards
near field proximity applications. In cell phones, the
proximity detection can detect when the user positions
the phone close to their ear. The device is fast enough
to provide proximity information at a high repetition
rate needed when answering a phone call. This provides
both improved “green” power saving capability and the
added security to lock the computer when the user is not
present. The addition of the micro-optics lenses within
the module, provide highly efficient transmission and
reception of infrared energy which lowers overall power
dissipation.
Ordering Information
Part Number
Packaging
Quantity
APDS-9930
Tape & Reel
2500 per reel
APDS-9930-140
Tape & Reel
1000 per reel
APDS-9930-200
Tape & Reel
1000 per reel
• Ambient Light Sensing (ALS)
– Approximates Human Eye Response
– Programmable Interrupt Function with Upper and
Lower Threshold
– Up to 16-Bit Resolution
– High Sensitivity Operates Behind Darkened Glass
– Low Lux Performance at 0.01 lux
• Proximity Detection
– Fully Calibrated to 100 mm Detection
– Integrated IR LED and Synchronous LED Driver
– Eliminates “Factory Calibration” of Prox
• Programmable Wait Timer
– Wait State Power – 90 µA Typical
– Programmable from 2.7 ms to > 8 sec
• I2C Interface Compatible
– Up to 400 kHz (I2C Fast-Mode)
– Dedicated Interrupt Pin
• Sleep Mode Power - 2.2 µA Typical
• Small Package L3.94 x W2.36 x H1.35 mm
Applications
•
•
•
•
•
•
Cell Phone Backlight Dimming
Cell Phone Touch-screen Disable
Notebook/Monitor Security
Automatic Speakerphone Enable
Automatic Menu Pop-up
Digital Camera Eye Sensor
Package Diagram
8 - VDD
1 - SDA
7 - SCL
2 - INT
6 - GND
3 - LDR
5 - LED A
4 - LED K
Functional Block Diagram
VDD
Interrupt
INT
Upper Threshold
ALS
ADC
Data
SCL
Lower Threshold
I2C Interface
Ch0
Ch1
Upper Threshold
Prox
Detect
ADC
LED A
SDA
Data
Lower Threshold
Prox IR
LED
LED K
LED Regulated
Constant Current
Sink
Control
Logic
LDR
GND
Detailed Description
The APDS-9930 light-to-digital device provides on-chip
Ch0 and Ch1 diodes, integrating amplifiers, ADCs, accumulators, clocks, buffers, comparators, a state machine and an
I2C interface. Each device combines one Ch0 photodiode
(visible plus infrared) and one Ch1 infrared-responding (IR)
photodiode. Two integrating ADCs simultaneously convert
the amplified photodiode currents to a digital value
providing up to 16-bits of resolution. Upon completion of
the conversion cycle, the conversion result is transferred to
the Ch0 and CH1 data registers. This digital output can be
read by a microprocessor where the illuminance (ambient
light level) in Lux is derived using an empirical formula to
approximate the human eye response.
Communication to the device is accomplished through a
fast (up to 400 kHz), two-wire I2C serial bus for easy connection to a microcontroller or embedded controller. The
digital output of the APDS-9930 device is inherently more
immune to noise when compared to an analog interface.
The APDS-9930 provides a separate pin for level-style
interrupts. When interrupts are enabled and a pre-set
value is exceeded, the interrupt pin is asserted and
remains asserted until cleared by the controlling firmware.
The interrupt feature simplifies and improves system
2
efficiency by eliminating the need to poll a sensor for a
light intensity or proximity value. An interrupt is generated
when the value of an ALS or proximity conversion exceeds
either an upper or lower threshold. Additionally, a programmable interrupt persistence feature allows the user
to determine how many consecutive exceeded thresholds
are necessary to trigger an interrupt. Interrupt thresholds
and persistence settings are configured independently for
both ALS and proximity.
Proximity detection is fully provided with an 850 nm IR
LED. An internal LED driver (LDR) pin, is jumper connected
to the LED cathode (LED K) to provide a factory calibrated
proximity of 100 +/- 20 mm. This is accomplished with a
proprietary current calibration technique that accounts
for all variances in silicon, optics, package and most importantly IR LED output power. This will eliminate or greatly
reduce the need for factory calibration that is required
for most discrete proximity sensor solutions. While the
APDS-9930 is factory calibrated at a given pulse count,
the number of proximity LED pulses can be programmed
from 1 to 255 pulses, which will allow greater proximity
distances to be achieved. Each pulse has a 16 µs period.
I/O Pins Configuration
PIN
NAME
TYPE
DESCRIPTION
1
SDA
I/O
I2C serial data I/O terminal – serial data I/O for I2C.
2
INT
O
Interrupt – open drain.
3
LDR
I
LED driver for proximity emitter – up to 100 mA, open drain.
4
LEDK
O
LED Cathode, connect to LDR pin in most systems to use internal LED driver circuit
5
LEDA
I
LED Anode, connect to VBATT on PCB
6
GND
7
SCL
8
VDD
Power supply ground. All voltages are referenced to GND.
I
I2C serial clock input terminal – clock signal for I2C serial data.
Power Supply voltage.
Absolute Maximum Ratings over operating free-air temperature range (unless otherwise noted)†
Parameter
Symbol
Power Supply voltage
VDD
Digital voltage range
Min
Max
Units
Test Conditions
3.8
V
[1]
-0.5
3.8
V
Digital output current
IO
-1
20
mA
Storage temperature range
Tstg
-40
85
°C
†
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
Note:
1. All voltages are with respect to GND.
Recommended Operating Conditions
Parameter
Symbol
Min
Operating Ambient Temperature
TA
-30
Supply voltage
VDD
2.2
Supply Voltage Accuracy, VDD
total error including transients
LED Supply Voltage
3
VBATT
Typ
3.0
Max
Units
85
°C
3.6
V
-3
+3
%
2.5
4.5
V
Operating Characteristics, VDD = 3 V, TA = 25° C (unless otherwise noted)
Parameter
Symbol
Supply current [1]
IDD
Min
Typ
Max
Units
Test Conditions
195
250
µA
Active (ATIME=0xdb, 100ms)
90
Wait Mode
2.2
INT SDA output low voltage
VOL
4.0
0
0.4
0
0.6
Sleep Mode
V
3 mA sink current
6 mA sink current
Leakage current, SDA, SCL, INT Pins
ILEAK
-5
5
µA
Leakage current, LDR Pin
ILEAK
-10
10
µA
SCL, SDA input high voltage
VIH
1.25
VDD
V
SCL, SDA input low voltage
VIL
0.54
V
Note:
1. The power consumption is raised by the programmed amount of Proximity LED Drive during the 8 us the LED pulse is on. The nominal and
maximum values are shown under Proximity Characteristics. There the IDD supply current is IDD Active + Proximity LED Drive programmed value.
ALS Characteristics, VDD = 3 V, TA = 25° C, Gain = 16, AEN = 1 , AGL = 0 (unless otherwise noted)
Parameter
Channel
Dark ALS ADC count value
Ch0
Ch1
ALS ADC Integration Time
Step Size
ALS ADC Number of
Integration Steps
Min
Typ
Max
0
1
5
5
2.90
ms
256
steps
1023
counts
65535
counts
ATIME = 0xC0
6000
counts
λp = 625 nm, Ee = 46.8 µW/cm2,
ATIME = 0xF6 (27 ms), Note 2
4000
5000
950
4000
Ch1
Gain scaling, relative to
1x gain setting
ATIME = 0xff
1
Ch1
ALS ADC count value ratio:
Ch1/Ch0
Ee = 0, AGAIN = 120x,
ATIME = 0xDB(100ms)
2.73
Full scale ADC count value
Ch0
counts
0
1
Ch0
Test Conditions
2.58
Full Scale ADC Counts per Step
ALS ADC count value
Units
5000
λp = 850 nm, Ee = 61.7 µW/cm2,
ATIME = 0xF6 (27 ms), Note 3
6000
2900
%
λp = 625 nm, ATIME = 0xF6 (27 ms)
15.2
19.0
22.8
43
58
73
λp = 850 nm, ATIME = 0xF6 (27 ms)
7.2
8.0
8.8
AGAIN = 8×
14.4
16.0
17.6
AGAIN = 16×
108
120
132
AGAIN = 120×
Notes:
1. Optical measurements are made using small-angle incident radiation from light-emitting diode optical sources. Red 625 nm LEDs and infrared 850
nm LEDs are used for final product testing for compatibility with high-volume production.
2. The 625 nm irradiance Ee is supplied by an AlInGaP light-emitting diode with the following characteristics: peak wavelength = 625 nm and spectral
halfwidth ½ = 20 nm.
3. The 850 nm irradiance Ee is supplied by a GaAs light-emitting diode with the following characteristics: peak wavelength = 850 nm and spectral
halfwidth ½ = 42 nm.
4
Proximity Characteristics, VDD = 3 V, TA = 25° C, PGAIN = 1, PEN = 1 (unless otherwise noted)
Parameter
Min
IDD Supply current – LDR Pulse On
ADC Conversion Time Step Size
Typ
3
2.58
ADC Number of Integration Steps
2.73
0
Units
ms
PTIME = 0xff
steps
PTIME = 0xff
1023
counts
PTIME = 0xff
255
pulses
2.9
16.0
µs
Proximity Pulse – LED On Time
7.3
µs
Proximity LED Drive
100
mA
Proximity Pulse Period
Proximity ADC count value, no object
Proximity ADC count value,
100 mm distance object
450
Test Conditions
mA
1
Full Scale ADC Counts
Proximity IR LED Pulse Count
Max
PDRIVE = 0
50
PDRIVE = 1
25
PDRIVE = 2
12.5
PDRIVE = 3
ISINK Sink current @ 600 mV,
LDR Pin
100
200
counts
Dedicated power supply VBatt = 3 V
LED driving 8 pulses, PDRIVE = 00, PGAIN = 10,
open view (no glass) and no reflective object
above the module. [1]
520
590
counts
Reflecting object – 73 mm x 83 mm Kodak
90% grey card, 100 mm distance,
LED driving 8 pulses, PDRIVE = 00, PGAIN = 10,
open view (no glass) above the module.
Tested value is the average of 5 consecutive
readings. [1]
Note:
1. 100 mA and 8 pulses are the recommended driving conditions. For other driving conditions, contact Avago Field Sales.
IR LED Characteristics, VDD = 3 V, TA = 25C
Parameter
Min
Typ
Max
Units
Test Conditions
Peak Wavelength, λP
850
nm
IF = 20 mA
Spectrum Width, Half Power, Δλ
40
nm
IF = 20 mA
Optical Rise Time, TR
20
ns
IFP = 100 mA
Optical Fall Time, TF
20
ns
IFP = 100 mA
Wait Characteristics, VDD = 3 V, TA = 25° C, Gain = 16, WEN = 1 (unless otherwise noted)
Parameter
Min
Wait Step Size
Wait Number of Step
5
Typ
2.73
1
Max
Units
Test Conditions
2.9
ms
WTIME = 0xff
256
steps
IR LED Characteristics, VDD = 3 V, TA = 25 °C (unless otherwise noted)
Parameter
Min
Typ
Max
Units
Test Conditions
Peak Wavelength, λP
850
nm
IF = 20 mA
Spectrum Width, Half Power, Δλ
40
nm
IF = 20 mA
Optical Rise Time, TR
20
ns
IF = 100 mA
Optical Fall Time, TF
20
ns
IF = 100 mA
Wait Characteristics, VDD = 3 V, TA = 25 °C, WEN = 1 (unless otherwise noted)
Parameter
Min
Typ
Max
Units
Test Conditions
Wait Step Size
2.27
2.4
2.56
ms
W TIME = 0×FF
AC Electrical Characteristics, VDD = 3 V, TA = 25 °C (unless otherwise noted) *
Parameter
Clock frequency (I2C-bus only)
Bus free time between a STOP and START condition
Symbol
Min.
Max.
Unit
fSCL
0
400
kHz
tBUF
1.3
–
µs
Hold time (repeated) START condition. After this period, the first clock pulse
is generated
tHDSTA
0.6
–
µs
Set-up time for a repeated START condition
tSU;STA
0.6
–
µs
Set-up time for STOP condition
tSU;STO
0.6
–
µs
Data hold time
tHD;DAT
0
–
ns
Data set-up time
tSU;DAT
100
–
ns
LOW period of the SCL clock
tLOW
1.3
–
µs
HIGH period of the SCL clock
tHIGH
0.6
–
µs
Clock/data fall time
tf
20
300
ns
Clock/data rise time
tr
20
300
ns
Input pin capacitance
Ci
–
10
pF
* Specified by design and characterization; not production tested.
t LOW
tr
V IH
V IL
SCL
t HD;STA
t HD;DAT
t BUF
t HIGH
t SU;STA
t SU;STO
tSU;DAT
V IH
V IL
SDA
P
Stop
Condition
S
Start
Condition
Figure 1. I2C Bus Timing Diagram
6
tf
S
P
30000
1
25000
CH0
0.8
Avg Sensor LUX
Normalized Responsitivity
1.2
0.6
CH1
0.4
0.2
15000
10000
5000
0
300
400
500
600 700 800
Wavelength (nm)
900
1000
0
1100
Figure 2. Spectral Response
1200
0.08
Avg Sensor LUX
0.1
Avg Sensor LUX
1500
900
600
0
0
300
600
900
Meter LUX
1200
15000 20000
Meter LUX
25000
30000
0.04
0
1500
1.20
1.30
1.15
1.20
1.10
1.10
1.00
0.90
0.80
0.70
0.60
0
0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09 0.1
Meter LUX
Figure 3c. ALS Sensor LUX vs. Meter LUX using Low Lux White Light
Normalized IDD @ 3V
Normalized IDD @ 3 V 25° C
10000
0.06
1.40
1.05
1.00
0.95
0.90
0.85
2
2.2
2.4
2.6
2.8
3
VDD (V)
3.2
3.4
3.6
0.80
3.8
Figure 4a. Normalized IDD vs. VDD
1.2
1.2
1
1
0.8
0.6
0.4
0.2
-80
-60
-40
-20
-60
-40
-20
0
20
40
Temperature (°C)
60
80
100
40
50
Figure 4b. Normalized IDD vs. Temperature
Normalized Radiant Intensity
Normalized Responsitivity
5000
0.02
Figure 3b. ALS Sensor LUX vs. Meter LUX using Incandescent Light
0
0
Figure 3a. ALS Sensor LUX vs. Meter LUX using White Light
300
0
20
Angle (Deg)
40
60
Figure 5a. Normalized PD Responsitivity vs. Angular Displacement
7
20000
80
0.8
0.6
0.4
0.2
0
-50
-40
-30
-20
-10 0
10
Angle (Deg)
20
Figure 5b. Normalized LED Angular Emitting Profile
30
PRINCIPLES OF OPERATION
Photodiodes
System State Machine
An internal state machine provides system control of
the ALS, proximity detection, and power management
features of the device. At power up, an internal power-onreset initializes the device and puts it in a low-power Sleep
state.
When a start condition is detected on the I2C bus, the
device transitions to the Idle state where it checks the
Enable register (0x00) PON bit. If PON is disabled, the device
will return to the Sleep state to save power. Otherwise, the
device will remain in the Idle state until a proximity or ALS
function is enabled. Once enabled, the device will execute
the Prox, Wait, and ALS states in sequence as indicated in
Figure 6. Upon completion and return to Idle, the device
will automatically begin a new prox−wait−ALS cycle as
long as PON and either PEN or AEN remain enabled.
If the Prox or ALS function generates an interrupt and the
Sleep-After-Interrupt (SAI) feature is enabled, the device
will transition to the Sleep state and remain in a low-power
mode until an I2C command is received.
Sleep
I 2C
!PON
Start
Idle
INT & SAI
INT & SAI
PEN
!PEN &
!WEN
& AEN
!WEN
& !AEN
Prox
!WEN
& AEN
!PEN &
WEN &
AEN
WEN
!AEN
ALS
Wait
Conventional silicon detectors respond strongly to infrared
light, which the human eye does not see. This can lead to
significant error when the infrared content of the ambient
light is high (such as with incandescent lighting) due to
the difference between the silicon detector response and
the brightness perceived by the human eye.
This problem is overcome in the APDS-9930 through the
use of two photodiodes. One of the photodiodes, referred
to as the Ch0 channel, is sensitive to both visible and
infrared light while the second photodiode is sensitive
primarily to infrared light. Two integrating ADCs convert
the photodiode currents to digital outputs. The CH1DATA
digital value is used to compensate for the effect of the
infrared component of light on the CH0DATA digital value.
The ADC digital outputs from the two channels are used in
a formula to obtain a value that approximates the human
eye response in units of Lux.
ALS Operation
The ALS engine contains ALS gain control (AGAIN) and
two integrating analog-to-digital converters (ADC) for
the Ch0 and Ch1 photodiodes. The ALS integration time
(ALSIT) impacts both the resolution and the sensitivity
of the ALS reading. Integration of both channels occurs
simultaneously and upon completion of the conversion
cycle, the results are transferred to the Ch0 and CH1 data
registers (Ch0DATAx and Ch1DATAx). This data is also
referred to as channel “count”. The transfers are doublebuffered to ensure that invalid data is not read during the
transfer. After the transfer, the device automatically moves
to the next state in accordance with the configured state
machine.
AEN
Figure 6. Simplified State Diagram
ATIME(r 1)
2.73 ms to 699 ms
CH0
ALS
C0DATAH(r0x15), C0DATA(r0x14)
ALS Control
CH0
CH1
ADC
CH1
Figure 7. ALS Operation
8
CH0
Data
CH1
Data
AGAIN(r0x0F, b1:0)
1 , 8 , 16 , 120 Gain
C1DATAH(r0x17), C1DATA(r0x16)
The ALS Timing register value (ATIME) for programming the integration time (ALSIT) is a 2’s complement values. The ALS
Timing register value can be calculated as follows:
ATIME = 256 – ALSIT / 2.73 ms
Inversely, the integration time can be calculated from the register value as follows:
ALSIT = 2.73 ms * (256 – ATIME)
In order to reject 50/60-Hz ripple strongly present in fluorescent lighting, the integration time needs to be programmed
in multiples of 10 / 8.3 ms or the half cycle time. Both frequencies can be rejected with a programmed value of 50 ms
(ATIME = 0xED) or multiples of 50 ms (i.e. 100, 150, 200, 400, 600).
The registers for programming the AGAIN hold a two-bit value representing a gain of 1×, 8×, 16×, or 120×. The gain, in
terms of amount of gain, will be represented by the value AGAINx, i.e. AGAINx = 1, 8, 16, or 120. With the AGL bit set, the
gains will be lowered to 1/6, 8/6, 16/6, and 20×, allowing for up to 30k lux.
Calculating ALS Lux
Definition:
CH0DATA = 256 * Ch0DATAH (r0x15) + Ch0DATAL (r0x14)
CH1DATA = 256 * Ch1DATAH (r0x17) + Ch1DATAL (r0x16)
IAC = IR Adjusted Count
LPC= Lux per Count
ALSIT = ALS Integration Time (ms)
AGAIN= ALS Gain
DF = Device Factor, DF = 52 for APDS-9930
GA = Glass (or Lens) Attenuation Factor
B, C, D – Coefficients
Lux Equation:
IAC1= CH0DATA – B x CH1DATA
IAC2= C x CH0DATA – D x CH1DATA
IAC = Max (IAC1, IAC2, 0)
LPC = GA x DF / (ALSIT × AGAIN)
Lux = IAC x LPC
Coefficients in open air:
GA= 0.49
B = 1.862
C = 0.746
D = 1.291
Sample Lux Calculation in Open Air
Assume the following constants:
ALSIT = 400
AGAIN= 1
LPC= GA x DF / (ALSIT × AGAIN)
LPC= 0.49 x 52 / (400 x 1)
LPC= 0.06
Assume the following measurements:
CH0DATA = 5000
CH1DATA = 525
Then:
IAC1= 5000 – 1.862 x 525 = 4022
IAC2= 0.746 x 5000 – 1.291 x 525 = 3052
IAC = Max (4022, 3052, 0) = 4022
Lux:
Lux= IAC X LPC
Lux= 4022 X 0.06
Lux= 256
Note: please refer to application note for coefficient GA, B, C and D calculation with window.
9
Proximity Detection
LEDA
IR
LED
PDL(r0x0D,b0)
PPULSE(r0x0E)
PDRIVE(r0x0F, b7:6)
PGAIN(r0x0F, b3:2)
POFFSET(r0x1E)
PTIME(r0x02)
LEDK
LDR
Prox LED
Current Driver
PVALID(r0x13, b1)
PSAT(r0x13, b6)
Prox Control
PDIODE(r0x0F, b5:4)
Object
Prox
Integration
Prox
ADC
Prox
Data
PDATAH(r0x019)
PDATAL(r0x018)
CH1
CH0
Background Energy
Figure 8. Proximity Detection
Proximity detection is accomplished by measuring the
amount of IR energy, from the internal IR LED, reflected off
an object to determine its distance. The internal proximity
IR LED is driven by the integrated proximity LED current
driver as shown in Figure 8.
The LED current driver, output on the LDR terminal,
provides a regulated current sink that eliminates the need
for an external current limiting resistor. The combination
of proximity LED drive strength (PDRIVE) and proximity
drive level (PDL) determine the drive current. PDRIVE sets
the drive current to 100 mA, 50 mA, 25 mA, or 12.5 mA
when PDL is not asserted. However, when PDL is asserted,
the drive current is reduced by a factor of 9.
Referring to the Detailed State Machine figure, the LED
current driver pulses the IR LED as shown in Figure 9 during
the Prox Accum state. Figure 9 also illustrates that the LED
On pulse has a fixed width of 7.3 μs and period of 16.0 μs.
So, in addition to setting the proximity drive current, 1 to
255 proximity pulses (PPULSE) can be programmed. When
deciding on the number of proximity pulses, keep in mind
that the signal increases proportionally to PPULSE, while
noise increases by the square root of PPULSE.
Figure 8 illustrates light rays emitting from the internal IR
LED, reflecting off an object, and being absorbed by the
CH1 photodiodes. The proximity diode selector (PDIODE)
selects Ch1 diode for a given proximity measurement.
Note that PDIODE must be set for proximity detection to
work.
Referring again to Figure 9, the reflected IR LED and the
background energy is integrated during the LED On time,
then during the LED Off time, the integrated background
energy is subtracted from the LED On time energy, leaving
the IR LED energy to accumulate from pulse to pulse. The
proximity gain (PGAIN) determines the integration rate,
which can be programmed to 1×, 2×, 4×, or 8× gain. At
power up, PGAIN defaults to 1× gain, which is recommended for most applications. For reference, PGAIN equal
to 4× is comparable to the APDS-9900’s 1× gain setting.
During LED On time integration, the proximity saturation
bit in the Status register (0x13) will be set if the integrator saturates. This condition can occur if the proximity
gain is set too high for the lighting conditions, such as in
the presence of bright sunlight. Once asserted, PSAT will
remain set until a special function proximity interrupt
clear command is received from the host (see command
register).
Reflected IR LED +
Background Energy
Background
Energy
LED On
LED Off
7.3 s
16.0 s
IR LED Pulses
Figure 9. Proximity LED Current Driver Waveform
10
After the programmed number of proximity pulses have
been generated, the proximity ADC converts and scales
the proximity measurement to a 16-bit value, then stores
the result in two 8-bit proximity data (PDATAx) registers.
ADC scaling is controlled by the proximity ADC conversion time (PTIME) which is programmable from 1 to 256
2.73-ms time units. However, depending on the application, scaling the proximity data will equally scale any accumulated noise. Therefore, in general, it is recommended
to leave PTIME at the default value of one 2.73 ms ADC
conversion time (0xFF).
utilizing the APDS-9930. The module package design
has been optimized for minimum package foot print and
short distance proximity of 100 mm typical. The spacing
between the glass surface and package top surface is
critical to controlling the crosstalk. If the package to top
surface spacing gap, window thickness and transmittance
are met, there should be no need to add additional components (such as a barrier) between the LED and photodiode. Thus with some simple mechanical design implementations, the APDS-9930 will perform well in the end
equipment system.
In many practical proximity applications, a number of
optical system and environmental conditions can produce
an offset in the proximity measurement result. To counter
these effects, a proximity offset (POFFSET) is provided
which allows the proximity data to be shifted positive or
negative.
APDS-9930 Module Optimized design parameters:
Once the first proximity cycle has completed, the
proximity valid (PVALID) bit in the Status register will be
set and remain set until the proximity detection function
is disabled (PEN).
Optical Design Considerations
The APDS-9930 simplifies the optical system design by
eliminating the need for light pipes and improves system
optical efficiency by providing apertures and package
shielding which will reduce crosstalk when placed in
the final system. By reducing the IR LED to glass surface
crosstalk, proximity performance is greatly improved
and enables a wide range of cell phone applications
• Window thickness, t ≤ 1.0 mm
• Air gap, g ≤ 1.0 mm [1]
• Assuming window IR transmittance 90%
Note:
1. Applications with an air gap from 0.5 mm to 1.0 mm are recommended
to use Poffset Register (0x1E) in their factory calibration.
The APDS-9930 is available in a low profile package that
contains optics that provide optical gain on both the
LED and the sensor side of the package. The device has
a package Z height of 1.35 mm and will support an air
gap of ≤ 1.0 mm between the glass and the package. The
assumption of the optical system level design is that glass
surface above the module is ≤ 1.0 mm.
By integrating the micro-optics in the package, the IR
energy emitted can be reduced thus conserving the
precious battery life in the application.
The system designer can optimize his designs for slim
form factor Z height as well as improve the proximity
sensing, save battery power, and disable the touch screen
in a cellular phone.
Plastic/Glass Window
Windows Thickness, t
Air Gap, g
APDS-9930
Figure 10. Proximity Detection
4P, 100 mA
6P,100 mA
8P, 100 mA
16P, 100 mA
0
2
4
6
8
10
Distance (cm)
12
14
16
Figure 11a. PS Output vs. Distance at 100 mA, PGAIN = 10, at various Pulse
Count. No glass in front of the module, 18% Kodak Grey Card.
11
1100
1000
900
800
700
600
500
400
300
200
100
0
PS Count
PS Count
1100
1000
900
800
700
600
500
400
300
200
100
0
4P, 100 mA
6P,100 mA
8P, 100 mA
16P, 100 mA
0
2
4
6
8
10
Distance (cm)
12
14
16
Figure 11b. PS Output vs. Distance at 100 mA, PGAIN = 10, at various Pulse
Count. No glass in front of the module, 90% Kodak Grey Card.
Interrupts
The interrupt feature simplifies and improves system efficiency by eliminating the need to poll the sensor for light
intensity or proximity values outside of a user-defined
range. While the interrupt function is always enabled
and its status is available in the status register (0x13), the
output of the interrupt state can be enabled using the
proximity interrupt enable (PIEN) or ALS interrupt enable
(AIEN) fields in the enable register (0x00).
Four 16-bit interrupt threshold registers allow the user
to set limits below and above a desired light level and
proximity range. An interrupt can be generated when
the ALS CH0 data (Ch0DATA) falls outside of the desired
light level range, as determined by the values in the ALS
interrupt low threshold registers (AILTx) and ALS interrupt
high threshold registers (AIHTx). Likewise, an out-of-range
proximity interrupt can be generated when the proximity
data (PDATA) falls below the proximity interrupt low
threshold (PILTx) or exceeds the proximity interrupt high
threshold (PIHTx).
PIHTH(r0x0B), PIHTL(r0x0A)
Upper Limit
Prox
Integration
Prox
ADC
It is important to note that the thresholds are evaluated in
sequence, first the low threshold, then the high threshold.
As a result, if the low threshold is set above the high
threshold, the high threshold is ignored and only the low
threshold is evaluated.
To further control when an interrupt occurs, the device
provides a persistence filter. The persistence filter allows
the user to specify the number of consecutive out-ofrange ALS or proximity occurrences before an interrupt
is generated. The persistence filter register (0x0C) allows
the user to set the ALS persistence filter (APERS) and the
proximity persistence filter (PPERS) values. See the persistence filter register for details on the persistence filter
values. Once the persistence filter generates an interrupt,
it will continue until a special function interrupt clear
command is received (see command register).
PPERS(r0x0C, b7:4)
Prox Persistence
Prox
Data
Lower Limit
PILTH(r09), PILTL(r08)
AIHTH(r07), AIHTL(r06)
CH1
Upper Limit
CH0
ADC
CH0
Data
Lower Limit
CH0
AILTH(r05), AILTL(r04)
Figure 12. Programmable Interrupt
12
APERS(r0x0C, b3:0)
ALS Persistence
State Diagram
When the power management feature is enabled (WEN),
the state machine will transition in turn to the Wait state.
The wait time is determined by WLONG, which extends
normal operation by 12× when asserted, and WTIME. The
formula to determine the wait time is given in the box associated with the Wait state in Figure 13.
The system state machine shown in Figure 6 provides an
overview of the states and state transitions that provide
system control of the device. This section highlights the
programmable features, which affect the state machine
cycle time, and provides details to determine system level
timing. Upon VDD power on, it is recommended to wait at
least 4.5ms before issuing the I2C command.
When the ALS feature is enabled (AEN), the state machine
will transition through the ALS Init and ALS ADC states.
The ALS Init state takes 2.73 ms, while the ALS ADC time
is dependent on the integration time (ATIME). The formula
to determine ALS ADC time is given in the associated box
in Figure 13. If an interrupt is generated as a result of the
ALS cycle, it will be asserted at the end of the ALS ADC
state and transition to the Sleep state if SAI is enabled.
When the proximity detection feature is enabled (PEN),
the state machine transitions through the Prox Init, Prox
Accum, Prox Wait, and Prox ADC states. The Prox Init and
Prox Wait times are a fixed 2.73 ms, whereas the Prox
Accum time is determined by the number of proximity LED
pulses (PPULSE) and the Prox ADC time is determined by
the integration time (PTIME). The formulas to determine
the Prox Accum and Prox ADC times are given in the associated boxes in Figure 13. If an interrupt is generated
as a result of the proximity cycle, it will be asserted at the
end of the Prox ADC state and transition to the Sleep state
if SAI is enabled.
Prox
Time: 2.73 ms
Sleep
Prox
Init
!PON
PEN
PPULSE: 0 ~ 255 pulses
Time: 16.0 µ s/pulse
Range: 0 ~ 4.1 ms
Time: 2.73 ms
PTIME: 1 ~ 256 steps
Time: 2.73 ms/step
Range: 2.73 ms ~ 699 ms
I 2 C Start
Prox
Accum
INT & SAI
Prox
Wait
Prox
ADC
ALS
ADC
!WEN &
!AEN
!AEN
ATIME: 1 ~ 256 steps
Time: 2.73 ms/step
Range: 2.73 ms ~ 699 ms
!PEN & !WEN
& AEN
!PEN & WEN
& AEN
ALS
Init
Time: 2.73 ms
!WEN &
AEN
AEN
WEN
Note: PON, PEN, WEN, AEN, and SAI are fields in the Enable register (0x00).
13
ALS
Idle
Wait
Figure 13. Extended State Diagram
INT & SAI
Time:
Range:
WTIME: 1 ~ 256 steps
WLONG = 0
WLONG = 1
32.8 ms/step
2.73 ms/step
32.8 ms ~ 8.39s
2.73 ms ~ 699 ms
Power Management
Power consumption can be managed with the Wait state, because the Wait state typically consumes only 90 μA of IDD
current. An example of the power management feature is given below. With the assumptions provided in the example,
average IDD is estimated to be 176 μA.
Power Management
SYSTEM STATE
MACHINE STATE
PROGRAMMABLE
PARAMETER
PROGRAMMED
VALUE
Prox Init
Prox Accum
PPULSE
0x04
DURATION
TYPICAL
CURRENT
2.73 ms
0.195 mA
0.064 ms
Prox Accum − LED On
0.029 ms (Note 1)
103 mA
Prox Accum − LED OFF
0.035 ms (Note 2)
0.195 mA
Prox Wait
2.73 ms
0.195 mA
Prox ADC
PTIME
0xFF
2.73 ms
0.195 mA
Wait
WTIME
WLONG
0xEE
0
49.2 ms
0.090 mA
2.73 ms
0.195 mA
ATIME
0xEE
49.2 ms
0.195 mA
ALS Init
ALS ADC
Notes:
1. Prox Accum − LED On time = 7.3 μs per pulse × 4 pulses = 29.3μs = 0.029 ms
2. Prox Accum − LED Off time = 8.7 μs per pulse × 4 pulses = 34.7μs = 0.035 ms
Average IDD Current = ((0.029 × 103) + (0.035 x 0.195) + (2.73 × 0.195) + (49.2 × 0.090) + (49.2 × 0.195) + (2.73 × 0.195 ×
3)) / 109 = 176 μA
Keeping with the same programmed values as per the example, the table below shows how the average IDD current
is affected by the Wait state time, which is determined by WEN, WTIME, and WLONG. Note that the worst-case current
occurs when the Wait state is not enabled.
Average IDD Current
WEN
WTIME
WLONG
WAIT STATE
AVERAGE IDD CURRENT
0
n/a
n/a
0 ms
245 μA
1
0xFF
0
2.73 ms
238 μA
1
0xEE
0
49.2 ms
176 μA
1
0x00
0
699 ms
103 μA
1
0x00
1
8389 ms
92 μA
14
Basic Software Operation
The following pseudo-code shows how to do basic initialization of the APDS-9930.
uint8 ATIME, PIME, WTIME, PPULSE;
ATIME = 0xff; // 2.7 ms – minimum ALS integration time
WTIME = 0xff; // 2.7 ms – minimum Wait time
PTIME = 0xff; // 2.7 ms – minimum Prox integration time
PPULSE = 1; // Minimum prox pulse count
WriteRegData(0, 0); //Disable and Powerdown
WriteRegData (1, ATIME);
WriteRegData (2, PTIME);
WriteRegData (3, WTIME);
WriteRegData (0xe, PPULSE);
uint8 PDRIVE, PDIODE, PGAIN, AGAIN;
PDRIVE = 0; //100mA of LED Power
PDIODE = 0x20; // CH1 Diode
PGAIN = 0; //1x Prox gain
AGAIN = 0; //1x ALS gain
WriteRegData (0xf, PDRIVE | PDIODE | PGAIN | AGAIN);
uint8 WEN, PEN, AEN, PON;
WEN = 8; // Enable Wait
PEN = 4; // Enable Prox
AEN = 2; // Enable ALS
PON = 1; // Enable Power On
WriteRegData (0, WEN | PEN | AEN | PON); // WriteRegData(0,0x0f );
Wait(12); //Wait for 12 ms
int CH0_data, CH1_data, Prox_data;
CH0_data = Read_Word(0x14);
CH1_data = Read_Word(0x16);
Prox_data = Read_Word(0x18);
WriteRegData(uint8 reg, uint8 data)
{
m_I2CBus.WriteI2C(0x39, 0x80 | reg, 1, &data);
}
uint16 Read_Word(uint8 reg);
{
uint8 barr[2];
m_I2CBus.ReadI2C(0x39, 0xA0 | reg, 2, ref barr);
return (uint16)(barr[0] + 256 * barr[1]);
}
15
I2C Protocol
of bytes. If a read command is issued, the register address
from the previous command will be used for data access.
Likewise, if the MSB of the command is not set, the device
will write a series of bytes at the address stored in the last
valid command with a register address. The command
byte contains either control information or a 5 bit register
address. The control commands can also be used to clear
interrupts. For a complete description of I2C protocols,
please review the I2C Specification at: http://www.NXP.
com
Interface and control of the APDS-9930 is accomplished
through an I2C serial compatible interface (standard or fast
mode) to a set of registers that provide access to device
control functions and output data. The device supports
a single slave address of 0x39 hex using 7 bit addressing
protocol. (Contact factory for other addressing options.)
The I2C standard provides for three types of bus transaction: read, write and a combined protocol. During a
write operation, the first byte written is a command byte
followed by data. In a combined protocol, the first byte
written is the command byte followed by reading a series
Start and Stop conditions
SDA
SCL
S
P
START condition
STOP condition
Data transfer on I2C-bus
P
SDA
MSB
SCL
S or Sr
1
acknowledgement
signal from slave
2
7
START or
repeated START
condition
8
MSB
MSB
1
9
ACK
2
3 to 8
9
ACK
acknowledgement
signal from receiver
1
2
3 to 8
A complete data transfer
SDA
SCL
1–7
8
9
1–7
8
9
1–7
8
9
P
S
START
condition
16
ADDRESS
R/W
ACK
DATA
ACK
DATA
ACK
STOP
condition
9
ACK
Sr
Sr or P
STOP or
repeated START
condition
A
Acknowledge (0)
N
Not Acknowledged (1)
P
Stop Condition
R
Read (1)
S
Start Condition
Sr
Repeated Start Condition
W
Write (0)
…
Continuation of protocol
Master-to-Slave
Slave-to-Master
1
7
1
1
8
1
8
1
1
S
Slave Address
W
A
Command Code
A
Data
A
P
1
8
1
8
1
1
A
Data Low
A
Data High
A
P
I2C Write Protocol
1
7
S
Slave Address
1
1
8
1
1
W
A
Command Code
A
P
I2C Write Protocol (Clear Interrupt)
1
7
1
1
8
S
Slave Address
W
A
Command Code
I2C Write Word Protocol
1
7
1
1
8
1
1
7
1
1
8
1
1
S
Slave Address
W
A
Command Code
A
Sr
Slave Address
R
A
Data
N
P
I2C Read Protocol – Combined Format
1
7
1
1
8
1
1
7
1
1
8
1
S
Slave Address
W
A
Command Code
A
Sr
Slave Address
R
A
Data Low
A
I2C Read Word Protocol
17
8
1
1
Data High
N
P
Register Set
The APDS-9930 is controlled and monitored by data registers and a command register accessed through the serial
interface. These registers provide for a variety of control functions and can be read to determine results of the ADC
conversions.
ADDRESS
RESISTER NAME
R/W
REGISTER FUNCTION
Reset Value
−
COMMAND
W
Specifies register address
0x00
0x00
ENABLE
R/W
Enable of states and interrupts
0x00
0x01
ATIME
R/W
ALS ADC time
0xFF
0x02
PTIME
R/W
Proximity ADC time
0xFF
0x03
WTIME
R/W
Wait time
0xFF
0x04
AILTL
R/W
ALS interrupt low threshold low byte
0x00
0x05
AILTH
R/W
ALS interrupt low threshold hi byte
0x00
0x06
AIHTL
R/W
ALS interrupt hi threshold low byte
0x00
0x07
AIHTL
R/W
ALS interrupt hi threshold hi byte
0x00
0x08
PILTL
R/W
Proximity interrupt low threshold low byte
0x00
0x09
PILTH
R/W
Proximity interrupt low threshold hi byte
0x00
0x0A
PIHTL
R/W
Proximity interrupt hi threshold low byte
0x00
0x0B
PIHTH
R/W
Proximity interrupt hi threshold hi byte
0x00
0x0C
PERS
R/W
Interrupt persistence filters
0x00
0x0D
CONFIG
R/W
Configuration
0x00
0x0E
PPULSE
R/W
Proximity pulse count
0x00
0x0F
CONTROL
R/W
Gain control register
0x00
0x12
ID
R
Device ID
ID
0x13
STATUS
R
Device status
0x00
0x14
Ch0DATAL
R
Ch0 ADC low data register
0x00
0x15
Ch0DATAH
R
Ch0 ADC high data register
0x00
0x16
Ch1DATAL
R
Ch1 ADC low data register
0x00
0x17
Ch1DATAH
R
Ch1 ADC high data register
0x00
0x18
PDATAL
R
Proximity ADC low data register
0x00
0x19
PDATAH
R
Proximity ADC high data register
0x00
0x1E
POFFSET
R/W
Proximity offset register
--
The mechanics of accessing a specific register depends on the specific protocol used. See the section on I2C protocols
on the previous pages. In general, the COMMAND register is written first to specify the specific control/status register
for following read/write operations.
18
Command Register
The command registers specifies the address of the target register for future write and read operations.
7
COMMAND
6
CMD
5
4
3
TYPE
2
1
0
ADD
–
FIELD
BITS
DESCRIPTION
COMMAND
7
Select Command Register. Must write as 1 when addressing COMMAND register.
TYPE
6:5
Selects type of transaction to follow in subsequent data transfers:
FIELD VALUE
INTEGRATION TIME
00
Repeated Byte protocol transaction
01
Auto-Increment protocol transaction
10
Reserved – Do not use
11
Special function – See description below
Byte protocol will repeatedly read the same register with each data access.
Block protocol will provide auto-increment function to read successive bytes.
ADD
4:0
Address register/special function register. Depending on the transaction type, see above, this field
either specifies a special function command or selects the specific control-status-register for
following write or read transactions:
FIELD VALUE
READ VALUE
00000
Normal – no action
00101
Proximity interrupt clear
00110
ALS interrupt clear
00111
Proximity and ALS interrupt clear
other
Reserved – Do not write
ALS/Proximity Interrupt Clear. Clears any pending ALS/Proximity interrupt. This special function is
self clearing.
Enable Register (0x00)
The ENABLE register is used primarily to power the APDS-9930 device on/off, enable functions, and interrupts.
ENABLE
7
6
5
4
3
2
1
0
Address
Reserved
SAI
PIEN
AIEN
WEN
PEN
AEN
PON
0x00
FIELD
BITS
DESCRIPTION
Reserved
7
Reserved. Write as 0.
SAI
6
Sleep after interrupt. When asserted, the device will power down at the end of a proximity or ALS
cycle if an interrupt has been generated.
PIEN
5
Proximity Interrupt Mask. When asserted, permits proximity interrupts to be generated.
AIEN
4
ALS Interrupt Mask. When asserted, permits ALS interrupt to be generated.
WEN
3
Wait Enable. This bit activates the wait feature. Writing a 1 activates the wait timer.
Writing a 0 disables the wait timer.
PEN
2
Proximity Enable. This bit activates the proximity function. Writing a 1 enables proximity.
Writing a 0 disables proximity.
AEN
1
ALS Enable. This bit actives the two channel ADC. Writing a 1 activates the ALS.
Writing a 0 disables the ALS.
PON
0
Power ON. This bit activates the internal oscillator to permit the timers and ADC channels to operate.
Writing a 1 activates the oscillator. Writing a 0 disables the oscillator.
19
ALS Timing Register (0x01)
The ALS timing register controls the integration time of the ALS Ch0 and Ch1 channel ADCs in 2.73 ms increments.
FIELD
BITS
DESCRIPTION
ATIME
7:0
VALUE
CYCLES
TIME (ALSIT)
Max Count
0xff
1
2.73 ms
1023
0xf6
10
27.3 ms
10239
0xdb
37
101 ms
37887
0xc0
64
175 ms
65535
0x00
256
699 ms
65535
Proximity Time Control Register (0x02)
The proximity timing register controls the integration time of the proximity ADC in 2.73 ms increments. It is recommended
that this register be programmed to a value of 0xff (1 cycle, 1023 bits).
FIELD
BITS
DESCRIPTION
PTIME
7:0
VALUE
CYCLES
TIME
Max Count
0xff
1
2.73 ms
1023
Wait Time Register (0x03)
Wait time is set 2.73 ms increments unless the WLONG bit is asserted in which case the wait times are 12x longer. WTIME
is programmed as a 2’s complement number.
FIELD
BITS
DESCRIPTION
WTIME
7:0
REGISTER VALUE
WALL TIME
TIME (WLONG = 0)
TIME (WLONG = 1)
0xff
1
2.73 ms
0.033 sec
0xb6
74
202 ms
2.4 sec
0x00
256
699 ms
8.4 sec
Note. The Proximity Wait Time Register should be configured before PEN and/or AEN is/are asserted.
ALS Interrupt Threshold Register (0x04 − 0x07)
The ALS interrupt threshold registers provides the values to be used as the high and low trigger points for the comparison function for interrupt generation. If Ch0 channel data crosses below the low threshold specified, or above the higher
threshold, an interrupt is asserted on the interrupt pin.
REGISTER
ADDRESS
BITS
DESCRIPTION
AILTL
0x04
7:0
ALS Ch0 channel low threshold lower byte
AILTH
0x05
7:0
ALS Ch0 channel low threshold upper byte
AIHTL
0x06
7:0
ALS Ch0 channel high threshold lower byte
AIHTH
0x07
7:0
ALS Ch0 channel high threshold upper byte
20
Proximity Interrupt Threshold Register (0x08 − 0x0B)
The proximity interrupt threshold registers provide the values to be used as the high and low trigger points for the comparison function for interrupt generation. If the value generated by proximity channel crosses below the lower threshold
specified, or above the higher threshold, an interrupt is signaled to the host processor.
REGISTER
ADDRESS
BITS
DESCRIPTION
PILTL
0x08
7:0
Proximity ADC channel low threshold lower byte
PILTH
0x09
7:0
Proximity ADC channel low threshold upper byte
PIHTL
0x0A
7:0
Proximity ADC channel high threshold lower byte
PIHTH
0x0B
7:0
Proximity ADC channel high threshold upper byte
Persistence Register (0x0C)
The persistence register controls the filtering interrupt capabilities of the device. Configurable filtering is provided to
allow interrupts to be generated after each ADC integration cycle or if the ADC integration has produced a result that
is outside of the values specified by threshold register for some specified amount of time. Separate filtering is provided
for proximity and ALS functions.
ALS interrupts are generated by looking only at the ADC integration results of channel 0.
7
6
PERS
5
4
3
PPERS
2
1
0
APERS
0x0c
FIELD
BITS
DESCRIPTION
PPERS
7:4
Proximity interrupt persistence. Controls rate of proximity interrupt to the host processor.
APERS
21
3:0
FIELD VALUE
MEANING
INTERRUPT PERSISTENCE FUNCTION
0000
Every
Every proximity cycle generates an interrupt
0001
1
1 consecutive proximity values out of range
…
…
…
1111
15
15 consecutive proximity values out of range
Interrupt persistence. Controls rate of interrupt to the host processor.
FIELD VALUE
MEANING
INTERRUPT PERSISTENCE FUNCTION
0000
Every
Every ALS cycle generates an interrupt
0001
1
1 consecutive Ch0 channel values out of range
0010
2
2 consecutive Ch0 channel values out of range
0011
3
3 consecutive Ch0 channel values out of range
0100
5
5 consecutive Ch0 channel values out of range
0101
10
10 consecutive Ch0 channel values out of range
0110
15
15 consecutive Ch0 channel values out of range
0111
20
20 consecutive Ch0 channel values out of range
1000
25
25 consecutive Ch0 channel values out of range
1001
30
30 consecutive Ch0 channel values out of range
1010
35
35 consecutive Ch0 channel values out of range
1011
40
40 consecutive Ch0 channel values out of range
1100
45
45 consecutive Ch0 channel values out of range
1101
50
50 consecutive Ch0 channel values out of range
1110
55
55 consecutive Ch0 channel values out of range
1111
60
60 consecutive Ch0 channel values out of range
Configuration Register (0x0D)
The configuration register sets the proximity LED drive level, wait long time, and ALS gain level.
7
6
CONFIG
5
4
3
Reserved
2
1
0
AGL
WLONG
PDL
0x0D
FIELD
BITS
DESCRIPTION
Reserved
7:3
Reserved. Write as 0.
AGL
2
ALS gain level. When asserted, the 1× and 8× ALS gain (AGAIN) modes are scaled by 0.16.
Otherwise,AGAIN is scaled by 1. Do not use with AGAIN greater than 8×.
WLONG
1
Wait Long. When asserted, the wait cycles are increased by a factor 12x from that programmed in
the WTIME register.
PDL
0
Proximity drive level. When asserted, the proximity LDR drive current is reduced by 9.
Proximity Pulse Count Register (0x0E)
The proximity pulse count register sets the number of proximity pulses that the LDR pin will generate during the Prox
Accum state. The pulses are generated at a 62.5 kHz rate. 100 mA and 8 pulses are the recommended driving conditions.
For other driving conditions, contact Avago Field Sales.
7
6
PPULSE
5
4
3
2
1
0
PPULSE
FIELD
BITS
DESCRIPTION
PPULSE
7:0
Proximity Pulse Count. Specifies the number of proximity pulses to be generated.
22
0x0E
Control Register (0x0F)
The Control register provides eight bits of miscellaneous control to the analog block. These bits typically control
functions such as gain settings and/or diode selection.
7
CONTROL
6
5
PDRIVE
4
PDIODE
FIELD
BITS
DESCRIPTION
PDRIVE
7:6
LED Drive Strength.
PDIODE
PGAIN
AGAIN
5:4
3:2
1:0
3
2
1
PGAIN
0
AGAIN
0x0F
FIELD VALUE
LED STRENGTH — PDL = 0
LED STRENGTH — PDL = 1
00
100 mA
11.1 mA
01
50 mA
5.6 mA
10
25 mA
2.8 mA
11
12.5 mA
1.4 mA
Proximity Diode Select.
FIELD VALUE
DIODE SELECTION
00
Reserved
01
Reserved
10
Proximity uses the Ch1 diode
11
Reserved
Proximity Gain Control.
FIELD VALUE
Proximity GAIN VALUE
00
1X Gain
01
2X Gain
10
4X Gain
11
8X Gain
ALS Gain Control.
FIELD VALUE
ALS GAIN VALUE
00
1X Gain
01
8X Gain
10
16X Gain
11
120X Gain
Device ID Register (0x12)
The ID register provides the value for the part number. The ID register is a read-only register.
7
6
5
4
ID
Device ID
FIELD
BITS
DESCRIPTION
ID
7:0
Part number identification
0x39 = APDS-9930
23
3
2
1
0
0x12
Status Register (0x13)
The Status Register provides the internal status of the device. This register is read only.
STATUS
7
6
5
4
3
2
1
0
Reserved
PSAT
PINT
AINT
Reserved
Reserved
PVALID
AVALID
0x13
FIELD
BITS
DESCRIPTION
Reserved
7
Reserved.
PSAT
6
Proximity Saturation. Indicates that the proximity measurement is saturated
PINT
5
Proximity Interrupt. Indicates that the device is asserting a proximity interrupt.
AINT
4
ALS Interrupt. Indicates that the device is asserting an ALS interrupt.
Reserved
3:2
Reserved.
PVALID
1
PS Valid. Indicates that the PS has completed an integration cycle.
AVALID
0
ALS Valid. Indicates that the ALS Ch0/Ch1 channels have completed an integration cycle.
ALS Data Registers (0x14 − 0x17)
ALS Ch0 and CH1 data are stored as two 16-bit values. To ensure the data is read correctly, a two byte read I2C transaction
should be used with auto increment protocol bits set in the command register. With this operation, when the lower byte
register is read, the upper eight bits are stored into a shadow register, which is read by a subsequent read to the upper
byte. The upper register will read the correct value even if additional ADC integration cycles end between the reading
of the lower and upper registers.
REGISTER
ADDRESS
BITS
DESCRIPTION
Ch0DATAL
0x14
7:0
ALS Ch0 channel data low byte
Ch0DATAH
0x15
7:0
ALS Ch0 channel data high byte
Ch1DATAL
0x16
7:0
ALS Ch1 channel data low byte
Ch1DATAH
0x17
7:0
ALS Ch1 channel data high byte
Proximity DATA Register (0x18 − 0x19)
Proximity data is stored as a 16-bit value. To ensure the data is read correctly, a two byte read I2C transaction should be
used with auto increment protocol bits set in the command register. With this operation, when the lower byte register
is read, the upper eight bits are stored into a shadow register, which is read by a subsequent read to the upper byte. The
upper register will read the correct value even if additional ADC integration cycles end between the reading of the lower
and upper registers.
REGISTER
ADDRESS
BITS
DESCRIPTION
PDATAL
0x18
7:0
Proximity data low byte
PDATAH
0x19
7:0
Proximity data high byte
24
Proximity Offset Register (0x1E)
The 8-bit proximity offset register provides compensation for proximity offsets caused by device variations, optical
crosstalk, and other environmental factors. Proximity offset is a sign-magnitude value where the sign bit, bit 7, determines if the offset is negative (bit 7 = 0) or positive (bit 7 = 1). The magnitude of the offset compensation depends on the
proximity gain (PGAIN), proximity LED drive strength (PDRIVE), and the number of proximity pulses (PPULSE). Because a
number of environmental factors contribute to proximity offset, this register is best suited for use in an adaptive closedloop control system.
7
POFFSET
6
5
SIGN
4
3
MAGINITUDE
2
1
0
Address
0x1E
FIELD
BITS
DESCRIPTION
SIGN
7
Proximity Offset Sign. The offset sign shifts the proximity data negative when equal to 0
and positive when equal to 1.
MAGNITUDE
6:0
Proximity Offset Magnitude. The offset magnitude shifts the proximity data positive or
negative, depending on the proximity offset sign. The actual amount of the shift depends
on the proximity gain (PGAIN), proximity LED drive strength (PDRIVE), and the number of
proximity pulses (PPULSE).
25
Application Information: Hardware
In a proximity sensing system, the included IR LED can be pulsed with more than 100 mA of rapidly switching current,
therefore, a few design considerations must be kept in mind to get the best performance. The key goal is to reduce the
power supply noise coupled back into the device during the LED pulses. Averaging of multiple proximity samples is
recommended to reduce the proximity noise.
The first recommendation is to use two power supplies; one for the device VDD and the other for the IR LED. In many
systems, there is a quiet analog supply and a noisy digital supply. By connecting the quiet supply to the VDD pin and the
noisy supply to the LEDA pin, the key goal can be met. Place a 1 μF low-ESR decoupling capacitor as close as possible to
the VDD pin and another at the LEDA pin, and at least 10 μF of bulk capacitance to supply the 100 mA current surge. This
may be distributed as two 4.7 μF capacitors.
V BUS
Voltage
Regulator
LEDK
V DD
LDR
1 µF
C*
GND
APDS-9930
RP
RP
R PI
INT
SCL
Voltage
Regulator
LEDA
SDA
1 µF
≥ 10 µF
* Cap Value Per Regulator Manufacturer Recommendation
Figure 14a. Proximity Sensing Using Separate Power Supplies
If it is not possible to provide two separate power supplies, the device can be operated from a single supply. A 22 Ω
resistor in series with the VDD supply line and a 1 μF low ESR capacitor effectively filter any power supply noise. The
previous capacitor placement considerations apply.
V BUS
22 Ω
Voltage
Regulator
LEDK
V DD
LDR
1 µF
≥ 10 µF
GND
APDS-9930
RP
RP
R PI
INT
SCL
LEDA
SDA
1 µF
Figure 14b. Proximity Sensing Using Single Power Supply
VBUS in the above figures refers to the I2C bus voltage. The I2C signals and the Interrupt are open-drain outputs and
require pull-up resistors. The pull-up resistor (RP) value is a function of the I2C bus speed, the I2C bus voltage, and the
capacitive load. A 10 kΩ pull-up resistor (RPI) can be used for the interrupt line.
26
Package Outline Dimensions
8
2
2
7
5
4
1.34
1.18 ±0.05
1.35 ±0.20
2.36 ±0.2
2.10 ±0.1
3
PINOUT
1 - SDA
2 - INT
3 - LDR
4 - LEDK
5 - LEDA
6 - GND
7 - SCL
8 - VDD
6
4
0.05
3
0.25 (x6)
6
3.94 ±0.2
Ø 0.90 ±0.05
3.73 ±0.1
1
2.40 ±0.05
7
1
0.58 ±0.05
8
5
0.80
0.60 ±0.075
(x8)
PCB Pad Layout
Suggested PCB pad layout guidelines for the Dual Flat No-Lead surface mount package are shown below.
0.60
0.80
0.72 (x8)
0.25 (x6)
0.60
Notes: all linear dimensions are in mm.
27
0.72 ±0.075
(x8)
Ø 1 ±0.05
0.05
±0
.10
4 ±0.10
0.29 ±0.02
B0
A
8 ±0.10
Ø1
Unit Orientation
±0
.05
A
5.50 ±0.05
12 +0.30
-0.10
4.30 ±0.10
Ø1
. 50
2 ±0.05
1.75 ±0.10
Tape Dimensions
2.70 ±0.10
K0
8° Max
A0
All dimensions unit: mm
Reel Dimensions
28
1.70 ±0.10
TAPE WIDTH
T
W1
W2
W3
12MM
4+/- .50
12.4 + 2.0
- 0.0
18.4 MAX
11.9 MIN
15.4 MAX
6° Max
Package Outline Dimensions for Option -140
4.94 ± 0.20
5
6
7
2.80 ± 0.20
8
0.50 ± 0.20
3.36 ± 0.20
0.50 ± 0.20
4
0.50 ± 0.20
0.50 ± 0.20
2
1
3
Side View
Top View
0.120 ± 0.075
4
3
2
0.80 (x8) ± 0.10
1
4.54 ± 0.10
0.200 ± 0.075
0.62 ± 0.10
0.45± 0.10
0.120 ± 0.075
5
6
7
0.80 (x8) ± 0.10
8
0.50 (x6) ± 0.10
Bottom View
0.80 (x8)
PCB Pad Layout for Option -140
0.50 (x6)
0.80 (x8)
0.45
0.62
4.54
29
+0
.1
0 0
Tape Dimensions for Option -140
B
A
3 deg Max
0.40 ±0.05
B
3.15 ±0.10
+0
.1
0 0
12 ±0.10
1.5
0
SECTION B-B
3.62 ±0.10
3 deg Max
SECTION A-A
Unit Orientation
Reel Dimensions for Option -140
30
TAPE WIDTH
T
W1
W2
W3
12MM
4+/- .50
12.4 + 2.0
- 0.0
18.4 MAX
11.9 MIN
15.4 MAX
5.20 ±0.10
A
5.50 ±0.05
12 ±0.20
4 ±0.10
2 ±0.10
1.75 ±0.10
1.5
0
(4.00x10)=40 ±0.20
Package Outline Dimensions for Option -200
4.94 ± 0.20
5
6
7
3.50 ± 0.20
8
0.50 ± 0.20
3.36 ± 0.20
0.50 ± 0.20
4
0.50 ± 0.20
0.50 ± 0.20
2
1
3
Side View
Top View
0.120 ± 0.075
4
3
2
1
0.80 (x8) ± 0.10
4.54 ± 0.10
0.200 ± 0.075
0.62 ± 0.10
0.45± 0.10
0.120 ± 0.075
5
6
7
0.80 (x8) ± 0.10
8
0.50 (x6) ± 0.10
Bottom View
0.80 (x8)
PCB Pad Layout for Option -200
0.50 (x6)
0.80 (x8)
0.45
0.62
4.54
31
1.5
0
(4.00x10)=40 ±0.20
B
A
0.40 ±0.05
3 deg Max
B
3.85 ±0.10
1.5
0
+0
.1
0 0
12 ±0.10
5.20 ±0.10
A
5.50 ±0.05
12 ±0.20
4 ±0.10
2 ±0.10
1.75 ±0.10
+0
.1
0 0
Tape Dimensions for Option -200
SECTION B-B
3.62 ±0.10
3 deg Max
SECTION A-A
Unit Orientation
Reel Dimensions for Option -200
32
TAPE WIDTH
T
W1
W2
W3
12MM
4+/- .50
12.4 + 2.0
- 0.0
18.4 MAX
11.9 MIN
15.4 MAX
Moisture Proof Packaging
All APDS-9930 options are shipped in moisture proof package. Once opened, moisture absorption begins. This part is
compliant to JEDEC MSL 3.
Units in A Sealed
Mositure-Proof
Package
Package Is
Opened (Unsealed)
Environment
less than 30 deg C, and
less than 60% RH?
Yes
Yes
No Baking
Is Necessary
Package Is
Opened less
than 168 hours?
No
Perform Recommended
Baking Conditions
Baking Conditions:
No
Recommended Storage Conditions:
Package
Temperature
Time
Storage Temperature
10° C to 30° C
In Reel
60° C
48 hours
Relative Humidity
below 60% RH
In Bulk
100° C
4 hours
Time from unsealing to soldering:
If the parts are not stored in dry conditions, they must be
baked before reflow to prevent damage to the parts.
Baking should only be done once.
33
After removal from the bag, the parts should be soldered
within 168 hours if stored at the recommended storage
conditions. If times longer than 168 hours are needed, the
parts must be stored in a dry box
Recommended Reflow Profile
MAX 260° C
R3
R4
TEMPERATURE (°C)
255
230
217
200
180
150
120
R2
60 sec to 120 sec
Above 217° C
R1
R5
80
25
0
P1
HEAT UP
Process Zone
Heat Up
Solder Paste Dry
50
100
150
P2
SOLDER PASTE DRY
Symbol
P1, R1
P2, R2
P3, R3
Solder Reflow
P3, R4
Cool Down
P4, R5
Time maintained above liquidus point , 217° C
Peak Temperature
Time within 5° C of actual Peak Temperature
Time 25° C to Peak Temperature
200
P3
SOLDER
REFLOW
250
P4
COOL
DOWN
300
t-TIME
(SECONDS)
∆T
Maximum ∆T/∆time
or Duration
25° C to 150° C
150° C to 200° C
200° C to 260° C
260° C to 200° C
200° C to 25° C
> 217° C
260° C
> 255° C
25° C to 260° C
3° C/s
100 s to 180s
3° C/s
-6° C/s
-6° C/s
60 s to 120 s
–
20 s to 40 s
8 mins
The reflow profile is a straight-line representation of
a nominal temperature profile for a convective reflow
solder process. The temperature profile is divided into
four process zones, each with different ∆T/∆time temperature change rates or duration. The ∆T/∆time rates or
duration are detailed in the above table. The temperatures
are measured at the component to printed circuit board
connections.
In process zone P1, the PC board and component pins
are heated to a temperature of 150° C to activate the flux
in the solder paste. The temperature ramp up rate, R1, is
limited to 3° C per second to allow for even heating of
both the PC board and component pins.
Process zone P2 should be of sufficient time duration (100
to 180 seconds) to dry the solder paste. The temperature is
raised to a level just below the liquidus point of the solder.
Process zone P3 is the solder reflow zone. In zone P3, the
temperature is quickly raised above the liquidus point of
solder to 260° C (500° F) for optimum results. The dwell
time above the liquidus point of solder should be between
60 and 120 seconds. This is to assure proper coalescing
of the solder paste into liquid solder and the formation
of good solder connections. Beyond the recommended
dwell time the intermetallic growth within the solder connections becomes excessive, resulting in the formation of
weak and unreliable connections. The temperature is then
rapidly reduced to a point below the solidus temperature
of the solder to allow the solder within the connections to
freeze solid.
Process zone P4 is the cool down after solder freeze. The
cool down rate, R5, from the liquidus point of the solder to
25° C (77° F) should not exceed 6° C per second maximum.
This limitation is necessary to allow the PC board and
component pins to change dimensions evenly, putting
minimal stresses on the component.
It is recommended to perform reflow soldering no more
than twice.
For product information and a complete list of distributors, please go to our web site: www.avagotech.com
Avago, Avago Technologies, and the A logo are trademarks of Avago Technologies in the United States and other countries.
Data subject to change. Copyright © 2005-2013 Avago Technologies. All rights reserved.
AV02-3190EN - July 9, 2013