ETC TS12001

TS12001
Version 1.3
nanoSmart® Battery Management Under-Voltage Load Switch
DESCRIPTION
FEATURES
The TS12001 Off-Active™ battery management
load switch is used to protect a battery from
excessive discharge. It consists of an internally
generated
threshold
voltage
(VTHRESH),
comparator with hysteresis, slew rate control for
the load switch, a P-Channel load switch, and an
open-drain indicator pin. When the input battery
voltage is above VTHRESH, the load switch is onactive. When the input battery voltage falls to
VTHRESH, the load switch is Off-Active™ and the
quiescent current draw is approximately 100pA.










APPLICATIONS






Portable Battery
Industrial
Medical
SmartCard
RFID
Energy Harvesting Systems
Off-Active™ feature with ultra-low pico-amp
current
Best-in-class Off-active™ quiescent current of
100pA
Ultra-low on-active quiescent current of 70nA
Accurate on to Off-active™ voltage threshold
Threshold voltage options of 1.2V - 4.2V in
100mV steps (programmed at manufacturing)
Supervisory over-current limit shutdown
Low Rds(on): 175mΩ typical @ 5V
Low drop out disconnect from VBAT to loads
Turn-on slew rate controlled
500mV off to on-active hysteresis
SUMMARY SPECIFICATIONS


Wide input voltage range: 1.2V – 5.5V
Packaged in a 8pin DFN (2x2)
Block Diagram
VCC
VOUT
R e g u la te d
T h re s h o ld
nPG
GND
Specifications subject to change
WWW.TRIUNESYSTEMS.COM
-1-
Copyright © 2012, Triune Systems, LLC
TS12001
Version 1.3
TYPICAL APPLICATIONS
Disconnect the Battery
Charger
Load
TS12001
VOUT
VCC
nPG
CBYP
GND
Note: When the TS12001 is Off-Active™, the battery will continue to charge through the body diode between VOUT and
VCC.
Disconnect the Load
Charger
TS12001
VOUT
Load
VCC
CBYP
Specifications subject to change
nPG
GND
WWW.TRIUNESYSTEMS.COM
-2-
Copyright © 2012, Triune Systems, LLC
TS12001
Version 1.3
PIN-OUT CONFIGURATION
PIN #
1
2
3
4
5
6
7
NAME
GND
VOUT
NC
NC
NC
VCC
VCC
I/O/P
P
O
8
nPG
O
DESCRIPTION
GND
Output to System Load
No Connect (connect to GND or float)
No Connect (connect to GND or float)
No Connect (connect to GND or float)
Supply Input
Supply Input
Open-Drain N-Channel Output (low indicates Power
Good)
I/P
I/P
ABSOLUTE MAXIMUM RATINGS
Over operating free–air temperature range unless otherwise noted(1,2,3)
PIN / PARAMETER
VALUE
UNIT
-0.3 to 6.0
V
2
kV
Operating Junction Temperature Range, TJ
-20 to 85
C
Storage Temperature Range, TSTG
-65 to 150
C
260
C
VCC, VOUT, nPG
Electrostatic Discharge – Human Body Model
Lead Temperature (soldering, 10 seconds)
Note 1: Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute–maximum–rated conditions for extended periods may affect device reliability.
Note 2: All voltage values are with respect to network ground terminal.
Note 3: ESD testing is performed according to the respective JESD22 JEDEC standard.
THERMAL CHARACTERISTICS
Package
DFN
JA (C/W)
(See Note 4)
JC (C/W)
(See Note 5)
8 pin
73.1
10.7
Note 4: This assumes a FR4 board only.
Note 5: This assumes a 1 Oz. Copper JEDEC standard board with thermal vias – See Exposed Pad section and application note for more information.
Specifications subject to change
WWW.TRIUNESYSTEMS.COM
-3-
Copyright © 2012, Triune Systems, LLC
TS12001
Version 1.3
RECOMMENDED OPERATING CONDITIONS
Parameter
Min
Unregulated Supply Input Voltage (VCC)
Typ
Max
Unit
1.2
5.5
V
Operating Ambient Temperature, TA (Note 6)
-20
55
°C
Operating Junction Temperature, TJ
-20
85
°C
100
Input Bypass Capacitor (CBYP)
nF
Note 6: TA Max shown here is a guideline. Higher TA can be tolerated if TJ does not exceed the Absolute Maximum Rating.
CHARACTERISTICS
Electrical characteristics, VCC = 1.2V to 5.5V, TJ = 25C, unless otherwise noted
Symbol
Parameter
Condition
Input Supply
VCC
Input Supply Voltage
Quiescent current:
Iq-ON
VCC = 5V, No Load
on-active Mode
ILEAK-SW
Typ
1.2
70
Max
Unit
5.5
V
150
nA
Quiescent current:
Off-Active™ Mode
VCC < VTHRESH, No Load
100
pA
Over Current Shutdown
Over Current Retry Period
Output Switch Leakage
Current
VCC = 5.0V
VCC = 5.0V
VCC < VTHRESH;
VOUT Grounded
3
1.7
A
ms
100
pA
Switch On Resistance
VCC = 5.0V
VCC = 3.3V
175
200
m
m
VCC = 1.8V
350
m
Iq-OFF
Load Switch
IOC
TOC
Min
Rds-on
Transition times
td1
Transition delay:
on-active to Off-Active™
VOFF = 2.0V, VCC = 3.0V  1.5V
650
s
td2
Transition delay:
Off-Active™ to on-active
VOFF = 2.0V, VCC = 1.5V  3.0V
1.7
ms
Output turn-on rise time
VCC = 2.5V, RLOAD = 50
200
s
Output Leakage
VCC = 5.0V, VnPG = 5.5V
100
nA
InPG = 5 mA
0.4
V
1.05*
VTHRESH
V
TON
nPG Output
ILEAK-nPG
Low-Level Output Voltage
VOL-nPG
Off-Active Thresholds
VOFF
Off-Active™ Threshold
VTHRESH = 1.2V to 3.3V
VHys
Off-Active™ to on-active
Hysteresis
Rising Transition:
Off-Active™ to on-active
Specifications subject to change
WWW.TRIUNESYSTEMS.COM
-4-
0.95*
VTHRESH
VTHRESH
500
mV
Copyright © 2012, Triune Systems, LLC
TS12001
Version 1.3
TYPICAL CHARACTERISTICS
On-Active / Off-Active™ Characteristics
On-Active Switching Behavior
On-Active / Off-Active™ Iq
Off-Active™ VTHRESH Temperature Performance
On-Active / Off-Active™ Transition Delay
Over Current Retry Performance
Specifications subject to change
WWW.TRIUNESYSTEMS.COM
-5-
Copyright © 2012, Triune Systems, LLC
TS12001
Version 1.3
PACKAGE MECHANICAL DRAWINGS
Specifications subject to change
WWW.TRIUNESYSTEMS.COM
-6-
Copyright © 2012, Triune Systems, LLC
TS12001
Version 1.3
RECOMMENDED PCB LAND PATTERN
Specifications subject to change
WWW.TRIUNESYSTEMS.COM
-7-
Copyright © 2012, Triune Systems, LLC
TS12001
Version 1.3
APPLICATION USING A MULTI-LAYER PCB
To maximize the efficiency of this package for application on a single layer or multi-layer PCB, certain guidelines must be
followed when laying out this part on the PCB.
The following are guidelines for mounting the exposed pad IC on a Multi-Layer PCB with ground a plane.
Solder Pad (Land Pattern)
Package Thermal Pad
Thermal Via's
Package Outline
Package and PCB Land Configuration
For a Multi-Layer PCB
JEDEC standard FR4 PCB Cross-section:
(square)
Package Solder Pad
Component Traces
1.5038 - 1.5748 mm
Component Trace
(2oz Cu)
2 Plane
4 Plane
1.5748mm
Thermal Via
1.0142 - 1.0502 mm
Ground Plane
(1oz Cu)
Thermal Isolation
Power plane only
0.5246 - 0.5606 mm
Power Plane
(1oz Cu)
0.0 - 0.071 mm Board Base
& Bottom Pad
Package Solder Pad
(bottom trace)
Multi-Layer Board (Cross-sectional View)
In a multi-layer board application, the thermal vias are the primary method of heat transfer from the package thermal pad to
the internal ground plane. The efficiency of this method depends on several factors, including die area, number of thermal vias,
thickness of copper, etc.
Specifications subject to change
WWW.TRIUNESYSTEMS.COM
-8-
Copyright © 2012, Triune Systems, LLC
TS12001
Version 1.3
Mold compound
Die
Epoxy Die attach
Exposed pad
Solder
5% - 10% Cu coverage
Single Layer, 2oz Cu
Ground Layer, 1oz Cu
Signal Layer, 1oz Cu
Thermal Vias with Cu plating
90% Cu coverage
20% Cu coverage
Bottom Layer, 2oz Cu
Note: NOT to Scale
The above drawing is a representation of how the heat can be conducted away from the die using an exposed pad package. Each
application will have different requirements and limitations and therefore the user should use sufficient copper to dissipate the
power in the system. The output current rating for the linear regulators may have to be de-rated for ambient temperatures
above 85C. The de-rate value will depend on calculated worst case power dissipation and the thermal management
implementation in the application.
APPLICATION USING A SINGLE LAYER PCB
Use as much Copper Area
as possible for heat spread
Package Thermal Pad
Package Outline
Layout recommendations for a Single Layer PCB: utilize as much Copper Area for Power Management. In a single layer board
application the thermal pad is attached to a heat spreader (copper areas) by using low thermal impedance attachment method
(solder paste or thermal conductive epoxy).
In both of the methods mentioned above it is advisable to use as much copper traces as possible to dissipate the heat.
IMPORTANT:
If the attachment method is NOT implemented correctly, the functionality of the product is not guaranteed. Power
dissipation capability will be adversely affected if the device is incorrectly mounted onto the circuit board.
Specifications subject to change
WWW.TRIUNESYSTEMS.COM
-9-
Copyright © 2012, Triune Systems, LLC
TS12001
Version 1.3
ORDERING INFORMATION
TS12001-CvvvDFNR
vvv
017
021
023
024
025
026
028
030
Threshold Voltage (VTHRESH)*
1.7 V
2.1 V
2.3 V
2.4 V
2.5 V
2.6 V
2.8 V
3.0 V
* Custom values also available (1.2V - 4.2V typical in 100mV increments)
Specifications subject to change
WWW.TRIUNESYSTEMS.COM
- 10 -
Copyright © 2012, Triune Systems, LLC
TS12001
Version 1.3
Legal Notices
Information contained in this publication regarding device applications and the like is provided only for your convenience and may be superseded by
updates. It is your responsibility to ensure that your application meets with your specifications. “Typical” parameters which may be provided in Triune
Systems data sheets and/or specifications can and do vary in different applications and actual performance may vary over time. All operating
parameters, including “Typicals” must be validated for your application by your technical experts. TRIUNE SYSTEMS MAKES NO REPRESENTATIONS
OR WARRANTIES OF ANY KIND WHETHER EXPRESS OR IMPLIED, WRITTEN OR ORAL, STATUTORY OR OTHERWISE, RELATED TO THE
INFORMATION, INCLUDING BUT NOT LIMITED TO ITS CONDITION, QUALITY, PERFORMANCE, MERCHANTABILITY OR FITNESS FOR
PURPOSE. Triune Systems disclaims all liability arising from this information and its use. Triune System products are not designed, intended, or
authorized for use as components in systems intended for surgical implant into the body, or other applications intended to support or sustain life, or for
any other application in which the failure of the Triune Systems product could create a situation where personal injury or death may occur. Should the
Buyer purchase or use Triune Systems products for any such unintended or unauthorized application, the Buyer shall indemnify and hold Triune Systems,
and its officers, employees, subsidiaries, affiliates, and distributors harmless against all claims, costs, damages, and expenses, and reasonable attorney
fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized use, even if such claim
alleges that Triune Systems was negligent regarding the design or manufacture of the part. No licenses are conveyed, implicitly or otherwise, under any
Triune Systems intellectual property rights.
Trademarks
The Triune Systems® name and logo, MPPT-lite™, Off-Active™, and nanoSmart® are trademarks of Triune Systems, LLC. in the U.S.A..
All other trademarks mentioned herein are property of their respective companies.
© 2012 Triune Systems, LLC. All Rights Reserved.
Specifications subject to change
WWW.TRIUNESYSTEMS.COM
- 11 -
Copyright © 2012, Triune Systems, LLC