Velociti® Series ASD-PL2F, ASD-PTL2F and ASD-PL2FR Description Analog, Addressable Photoelectronic Smoke Sensor The Gamewell-FCI Velociti® Series, analog addressable plug-in smoke sensors with integral communication provide features that surpass conventional sensors. Sensitivity can be programmed in the control panel software, and is continuously monitored and reported to the panel. Point ID capability allows each sensor’s address to be set, providing exact locations for selective maintenance when the chamber contamination reaches an unacceptable level. The ASD-PL2F photoelectric sensor’s unique optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources. Dual electronic thermistors add 135°F (57°C) fixed-temperature thermal sensing on the ASD-PTL2F model. ASD-PL2FR ASD-PL2F/ASD-PTL2F Features • Sleek, low-profile design. • Visual rotary, decimal switch addressing (01-159). • Built-in functional test switch activated by an external The Velociti® Series use a communication protocol that substantially increases the speed of communication between the sensors and certain Gamewell-FCI analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel’s microprocessor stops the group poll and concentrates on the single device. The net effect is a response speed up to five times greater than earlier designs. magnet. • Bicolor LEDs flash green whenever the sensor is addressed, and light steady red on alarm.* • Optional relay, isolator, or sounder bases. • Low standby current. • Analog addressable communication. • Stable communication technique with noise immunity. • Optional remote, single-gang LED Indicator (RA100Z). • Compatible with Gamewell-FCI analog addressable panels. Ordering Information Part Number Description ASD-PL2F Analog, addressable photoelectronic smoke sensor ASD-PTL2F Analog, addressable photoelectronic smoke sensor with thermal sensing ASD-PL2FR Analog, addressable photoelectronic smoke sensor used with the DNR duct base when the remote test is required. Note: *Only the red LED is operative in panels that do not operate in Velociti® mode. SIGNALING FM Velociti® is a registered trademark of Honeywell International Inc. APPROVED S1913 UL® is a registered trademark of Underwriters Laboratories Inc. MEA Approved FDNY 3023594 COA #:219-02-E 7272-1703:0121 Vol.VI GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1653 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. www.gamewell-fci.com 9020-0617 Rev. J page 1 of 2 ©2013 by Honeywell International Inc. All rights reserved. Installation Specifications ASD-PL2F plug-in sensors use a separate base to simplify installation, service, and maintenance. A special tool allows maintenance personnel to plug-in and remove sensors without using a ladder. Mount the base on a box which is at least 1.5" (3.8 cm) deep. Suitable mounting base boxes include: • 4.0" (10.2 cm) square box. • 3.5" (8.9 cm) or 4.0" (10.2 cm) octagonal box. • Single-gang box (except relay or isolator bases). • With B200S or B200SR base, mounted on a 4.0" (10.2 cm) octagonal or square box. • With B224RB or B224BI base, mounted on a 3.5" ASD-PL2F, ASD-PTL2F, ASD-PL2FR: 2.1” (5.1 cm) height 4.1” (10.4 cm) installed in the B501 base 6.1” (15.5 cm) installed in the B210LP base Shipping Weight: 5.2 oz. (147 g) Operating ASD-PL2F: 32° F to 120° F (0° C to 49° C) Temperature: ASD-PTL2F: 32° F to 100° F (0° C to 38° C) 0-4000 ft./min. (1,219.2 m/min.), UL®-Listed Velocity Range: suitable for installation in ducts. Relative 10-93% (non-condensing) Humidity: Thermal Ratings: Fixed-temperature setpoint 135° F (57° C) Dimensions: Diameter: (8.9 cm) octagonal box, or a 4.0" (10.2 cm) octagonal or Electrical Specifications square box. NOTE: Because of the inherent supervision provided by the SLC, end-of-line resistors are not required. Wiring “T-taps” or branches are permitted for Style 4 (Class “B”) wiring. Sensor Spacing Gamewell-FCI recommends that the spacing sensors be used in compliance with NFPA 72. Voltage Range: 15 – 32 volts DC peak Standby Current: (max. avg.): .0003 A @ 24 VDC (One communication every 5 seconds with LED blink enabled). Maximum Alarm.0065 A @ 24 VDC (LED) lit). Current: Bases and Options B501 Dimensions: B210LP Dimensions: B210LPBP Dimensions: B224RB Relay Base Dimensions: B200S Dimensions: B200SR Dimensions: RA100Z BCK-200 DNR Plug-in sensor base without flange 4.1” (10.4 cm) diameter Flanged mounting base 6.1” (15.5 cm) diameter Flanged mounting base bulk pack 6.1” (15.5 cm) diameter Plug-in sensor base with auxiliary relay, SPDT, rated 2 amps @ 30 VDC (resistive). Screw terminals: Up to 14 AWG (2.0 mm2) 2 coil latching relay 1 Form C contact UL/CSA Rating: 0.9 A @ 125 VAC, inductive 0.9 A @ 110 VDC, inductive 3 A @ 30 VDC, resistive 6.1” (15.5 cm) diameter Maximum: 25 devices between isolator bases. Intelligent sensor sounder base 6.875” (17.5 cm) diameter Standard sounder base, UL 8649th Edition compliant, ULC Listed 6.875” (17.5 cm) diameter Remote LED Annunciator Black detector covers (box of 10) Duct smoke housing GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1653 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9020-0617 Rev. J page 2 of 2 www.gamewell-fci.com