Application Notes

Applications
Servers, Switches and Data Storage
U10 Series DC/DC Converters •• Wireless
Communications
• Distributed Power Architecture
Application Notes
• Semiconductor Test Equipment
• Networking Gear
• Data Communications
• Telecommunications
• Industrial / Medical
Basic operation and functions
U10 series is single and dual output
DC/DC converters provide form 6.6
watts up to 10watts of output power
in an industry standard 1”x2” size
package. The U10 series features
4:1 input voltage range, high
efficiency, fixed switching frequency
300KHz, continuous short circuit
protection, six-side continuous shield
and 500VDC isolation.
Protection Features
Input under voltage lockout(UVLO)
Input under voltage lockout(UVLO) is
standard with the U10 unit. The unit
will shut down when the input
voltage drops below a threshold, and
the unit will turn on when the input
voltage goes to the upper thershold.
The hystersis voltage of the unit
voltage protection is 0.4V(tvpical),
normally from the 8V to 7.6V range.
Input (Vi+ , Vi-)
Input power Vin+ must be connected
to Positive input voltage(Vi+) ; Input
power Vin- must be connected to
Negative voltage(Vi-).
Output over current protection(OCP)
and output short protection
The unit will auto recovery current
limit when the over current or short
circuit condition exists.
Once the OCP happens, the unit has
auto recovery current limit and
output voltage above 6V. The
attempted restart will continue
indefinitely until the over current or
short circuit condition is removed.
Output (Vo+ , Vo- )
Output power Vout+ must be
connected to Positive output voltage
(Vo+) ; Output power Vout- must be
Negative output voltage (Vo-).
CH1:+Vout/OCP Ch2:-Vout/OCP
1/4
•
•
Intronics Power Inc. 1400 Providence Highway, Building 2, Norwood, MA 02062-5015 Phone: 1-781-551-5500 Fax:
1-781-551-5555
Rev. B
Applications
Servers, Switches and Data Storage
U10 Series DC/DC Converters •• Wireless
Communications
• Distributed Power Architecture
Application Notes
• Semiconductor Test Equipment
When output short happens, the
output voltage drops below 0.2V.
• Networking Gear
• Data Communications
• Telecommunications
• Industrial / Medical
Characterization
General information
The U10 unit has many operational
characterized aspects, including
efficiency, start up , overshoot,
output ripple & noise, hold time,
dynamic response to load and input
ripple current.
The following pages contain specific
plots or waveforms associated with
the unit. Additional comments for
specific data are provided below.
And all test function at 24Vinput.
CH1:+Vout/short Ch2:-Vout/short
Efficiency
Efficiency vs load current is given
below. The ambient temperature is
25℃, airfolw is 20LFM(0.1m/s), and
the input voltage is 9V, 24V and 36V
conditions.
U10-24D12 Eff.
2/4
•
•
Intronics Power Inc. 1400 Providence Highway, Building 2, Norwood, MA 02062-5015 Phone: 1-781-551-5500 Fax:
1-781-551-5555
Rev. B
Applications
Servers, Switches and Data Storage
U10 Series DC/DC Converters •• Wireless
Communications
• Distributed Power Architecture
Application Notes
• Semiconductor Test Equipment
• Networking Gear
• Data Communications
• Telecommunications
• Industrial / Medical
Start up
The input start-up from power
supply.
CH1:+Vout/NL Ch2:-Vout/NL
Overshoot:zero %
Rise time:3.719ms / 3.756ms
Output Ripple and Noise
The output voltage waveform
measured at minimum load and full
load current, with a 0.1uF ceramic
capacitor across to close unit.
CH1:Vin=24V CH2:Vout=24V / FL
Start up delay time:5.84ms
Overshoot and rise time
The input start-up from power supply.
The output voltage waveform
measured at minimum load and full
load current.
CH1:+Vout/FL Ch2:-Vout/FL
Ripple:36.4mVp-p / 31.6mVp-p
Hold time
The hold time is measure from the
power supply end or on/off pin is off
to when Vout drop down to 90%
output.
CH1:+Vout/FL Ch2:-Vout/FL
Overshoot:zero %
Rise time:2.183ms / 2.178ms
3/4
•
•
Intronics Power Inc. 1400 Providence Highway, Building 2, Norwood, MA 02062-5015 Phone: 1-781-551-5500 Fax:
1-781-551-5555
Rev. B
Applications
Servers, Switches and Data Storage
U10 Series DC/DC Converters •• Wireless
Communications
• Distributed Power Architecture
Application Notes
• Semiconductor Test Equipment
• Networking Gear
• Data Communications
• Telecommunications
• Industrial / Medical
CH1:Vout Ch2:Iout, 0.1A/us
Load change 25%-75%-25%
Input ripple current
CH1:Vin Ch2:Vout/FL
Hold time:440us
Dynamic response
Output voltage dynamic response at
Vin=24V and different load condition.
Output with a 0.1uF ceramic
capacitor.
CH1:Vout Ch2:Iout, 0.1A/us
Load change 50%-100%-50%
4/4
•
•
Intronics Power Inc. 1400 Providence Highway, Building 2, Norwood, MA 02062-5015 Phone: 1-781-551-5500 Fax:
1-781-551-5555
Rev. B