High-performance OCXO in SMD package
Parameter
Nominal frequency (Note 2)
Frequency stability
Initial tolerance @ +25°C
vs. operating temperature range
vs. supply voltage variation
vs. load change
Long term (aging) per day
st
Long term (aging) 1 year
Long term (aging) per 15 years after
Frequency adjustment range
Electronic Frequency Control (EFC)
EFC voltage VC
EFC slope (∆f / ∆VC)
EFC non-linearity
EFC input impedance
RF output
Signal waveform
Load RL
Output level
Harmonics
Spurious
Warm-up time @ +25°C
Phase noise
Short term stability (Allan deviation)
Oven alarm output (Pin 2)
Oscillator enable input (Pin 6)
(Note 3)
Reference voltage VREF output
Supply voltage VS
Current consumption (steady state)
Current consumption (warm-up)
Operating temperature range
Enclosure (see drawing) (LxWxH)
Weight
Packing
Notes:
1.
2.
3.
min.
typ.
max.
Unit
Condition
±0.5
±0.5
±30
±500
MHz
ppm
ppb
ppb
ppb
ppb
ppb
ppb
ppb
VC @ VREF/2
steady state
VS ±5%
RL ±5%
after 30 days operation
after 30 days operation
after 30 days operation
VREF
ppm
V
10.000
±50
±100
±5
±0.5
±0.8
0
±1.0
2.5
Positive
2
Date: 2014-04-18
5
100
Sine wave
50
+5
+10
-30
-90
3
10
-105
-100
-135
-130
-150
-145
-150
-157
-160
-150
-12
-12
2·10
5·10
-12
-11
2·10
1·10
-12
-11
5·10
5·10
LOW = alarm (not stable)
HIGH = ready
LOW = Oscillator OFF
HIGH = Oscillator ON
5.0
11.4
12.0
12.6
150
350
-20
+70
25.6x22.2x14 max.
15
Tape & Reel
%
kΩ
Ω
dBm
dBc
dBc
min
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
V
V
mA
mA
°C
mm
g
±5%
∆ffinal/fnominal < ±100 ppb
@ 1Hz
@ 10 Hz
@ 100 Hz
@ 1 kHz
@ 10 kHz ~ 100 kHz
τ=1s
τ = 10 s
τ = 100 s
0 … 0.4 V
2.4 … 5 V
0 … 0.4 V
2.4 … 12.6 V
@ +25°C
IEC 61837 CO 28
IEC 60286-3
Terminology and test conditions are according to IEC60679-1 and MIL-PRF-55310, unless otherwise stated
Other frequencies on request
HCMOS compatible input
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
AXIOM10HP Rev.4
Drawing D0
Page 1(3)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Designed and
Manufactured
in Germany
Absolute Maximum Ratings
Parameter
min.
max.
Supply Voltage VS
Control Voltage VC
Oscillator Enable Voltage VOE
Storage Temperature
-0.5
-0.5
-0.5
-55
VS + 10%
15
VS
+125
Unit
Condition
V
V
V
°C
VS to GND
VC to GND
VOE to GND
Ordering Code
Model
Revision
Frequency [MHz]
AXIOM10HP
Rev.4
10.000
Example: AXIOM10HP_Rev.4 – 100.000 MHz
Enclosure drawing:
Pin connections
Pin #
1
2
3
4
5
6
7
Symbol
RF OUT
OA
GND
VREF
VC
OE
VS
Function
RF Output
Oven Alarm Output
Ground
Reference Voltage
Control Voltage (EFC)
Oscillator Enable Input
Supply Voltage
* See Application Note AXAN-011
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
AXIOM10HP Rev.4
Drawing D0
Page 2(3)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Designed and
Manufactured
in Germany
Handling and Testing
Parameter
Procedure
Handling and Testing
Processing
Source
Application Note AXAN-011
Application Note AXAN-012
Parameter
Procedure
Electrostatic discharge (ESD)
THD devices
SMD devices
Washable
RoHS- Compliant
IEC60749-26
IEC60749-27
Yes
Yes
www.axtal.com
www.axtal.com
Condition
HBM
MM
No
No
2000 V
200 V
Environmental conditions
Test
Sealing tests
(if applicable)
Solderability
Resistance to
soldering heat
Shock*
IEC
60068
Part …
2-17
IEC
60679-1
Clause
5.6.2
MIL-STD202G
Method
112E
2-20
2-58
5.6.3
208H
210F
2-27
5.6.8
213B
Vibration,
2-6
5.6.7.1
201A
sinusoidal*
204D
Vibration,
2-64
5.6.7.3
214A
random*
Endurance tests
108A
- ageing
5.7.1
- extended aging
5.7.2
Other environmental conditions on request
MIL-STD810F
Method
MIL-PRF55310D
Clause
3.6.1.2
3.6.52
3.6.48
516.4
3.6.40
516.4-4
3.6.38.1
3.6.38.2
3.6.38.3
3.6.38.4
514.5
4.8.35
Test conditions (IEC)
Gross leak: Test Qc,
Fine leak: Test Qk
Test Ta Method 1
Test Td1 Method 2
Test Td2 Method 2
Test Ea, 3 x per axes 100g,
6 ms half-sine pulse
Test Fc, 30 min per axes,
10 Hz - 55 Hz 0,75mm; 55 Hz - 2 kHz, 10g
Test Fdb
30 days @ 85°C, OCXO @25°C
1000h, 2000h, 8000h @85°C
Data sheet is for information purposes only and may be subject to modifications or may be discontinued without notice.
Revision History
Rev.
Drawing
Date
[dd.mm.yyyy]
3
4
D1
D0
01.10.2012
18.04.2014
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
Remarks
Editorial changes
Various parameters updated,
environmental conditions updated, editorial changes
AXIOM10HP Rev.4
Drawing D0
Page 3(3)
Author
Checked
BN
HH
BN
HH
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]