Specification AXIOM75-44 Oscillator type: High Stability

Designed and
Manufactured
in Germany
Specification
Oscillator type:
Rev.: 1
Date: 2014-07-04
AXIOM75-44
High Stability OCXO with Sine Wave Output
Parameter
Nominal frequency
Frequency stability
Initial tolerance @ +25°C
Overall
vs. supply voltage variation (pushing)
vs. load change (pulling)
Long term (aging) per day
st
Long term (aging) 1 year (Note 2)
Frequency adjustment range
Electronic Frequency Control (EFC)
EFC voltage VC
EFC slope (∆f / ∆VC)
EFC input impedance
RF output
Signal waveform
Load RL
Output level
Harmonics
Spurious
Warm-up time @ +25°C
Phase noise
Supply voltage VS
Current consumption (steady state)
Current consumption (warm-up)
Operating temperature range
Enclosure (see drawing) (LxWxH)
Weight
Packing
Notes:
1.
2.
min.
typ.
max.
10.000
2.0
Positive
±200
±150
ppb
ppb
ppb
ppb
ppb
ppb
±1
4.0
ppm
V
100
+4
@VC =2.0 V
(Note 2)
VS ±5% (Note 2)
RL ±5%
after 30 days operation
after 30 days operation
kΩ
Sine wave
50
+5
5
13.5
Condition
MHz
±10
±5
±2
±50
±0.3
0
Unit
15.0
-20
+6
-25
-90
7
-140
-145
-150
-155
16.5
200
400
+70
25.8x25.8x15 max.
20
Palette
Ω
dBm
dBc
dBc
min
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
V
mA
mA
°C
mm
g
±5%
∆ffinal/f0 < ±0.1 ppm
@ 100 Hz
@ 1 kHz
@ 10 kHz
@ 100 kHz
@ +25°C
IEC 60679-3 CO 43
Terminology and test conditions are according to IEC60679-1 and MIL-PRF-55310, unless otherwise state
Overall stability includes frequency stability over operating temperature range , aging (1 year) and pushing
Absolute Maximum Ratings
Parameter
min.
max.
Supply Voltage VS
Control Voltage VC
Storage Temperature
-0.5
-0.5
-55
VS + 10%
15
+125
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
AXIOM75-44 Rev.1
Drawing D0
Page 1(3)
Unit
Condition
V
V
°C
VS to GND
VC to GND
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Designed and
Manufactured
in Germany
Ordering Code
Model
Revision Frequency [MHz]
AXIOM75-44
Rev.1
10.000
Example: AXIOM75-44_Rev.1 – 10.000 MHz
Enclosure drawing
Pin connections
Pin #
1
2
3
4
5
Handling and Testing
Parameter
Handling and Testing
Processing
Parameter
Electrostatic discharge (ESD)
THD devices
SMD devices
Washable
RoHS- Compliant
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
Symbol
RF OUT
GND
VC
N.C.
VS
Procedure
Application Note AXAN-011
Application Note AXAN-012
Procedure
IEC60749-26
IEC60749-27
Yes
Yes
AXIOM75-44 Rev.1
Drawing D0
Page 2(3)
HBM
MM
No
No
Function
RF Output
Ground
Control Voltage (EFC)
No connection
Supply Voltage
Source
www.axtal.com
www.axtal.com
Condition
2000 V
200 V
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Designed and
Manufactured
in Germany
Environmental conditions
Test
Sealing tests
(if applicable)
Solderability
Resistance to
soldering heat
Shock*
Vibration,
sinusoidal*
Vibration,
random*
Endurance tests
- ageing
- extended aging
IEC
60068
Part …
2-17
IEC
60679-1
Clause
5.6.2
MIL-STD202G
Method
112E
MIL-STD810F
Method
MIL-PRF55310D
Clause
3.6.1.2
2-20
2-58
5.6.3
208H
210F
2-27
5.6.8
213B
516.4
3.6.40
2-6
5.6.7.1
516.4-4
2-64
5.6.7.3
201A
204D
214A
3.6.38.1
3.6.38.2
3.6.38.3
3.6.38.4
3.6.52
3.6.48
514.5
Test conditions (IEC)
Gross leak: Test Qc,
Fine leak: Test Qk
Test Ta Method 1
Test Td1 Method 2
Test Td2 Method 2
Test Ea, 3 x per axes 100g,
6 ms half-sine pulse
Test Fc, 30 min per axes,
10 Hz - 55 Hz 0,75mm; 55 Hz - 2 kHz, 10g
Test Fdb
108A
5.7.1
5.7.2
4.8.35
30 days @ 85°C, OCXO @25°C
1000h, 2000h, 8000h @85°C
Revision History
Rev.
Drawing
Date
[dd.mm.yyyy]
1
D0
04.07.2014
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
Remarks
First issue AXIOM75-44
AXIOM75-44 Rev.1
Drawing D0
Page 3(3)
Author
Checked
BN
BN
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]