Intel® Solid-State Drive DC P3700 Series Capacities: 400GB, 800GB, 1.6TB, 2TB Components – Intel® 20nm MLC NAND Flash Memory Form Factors – 2.5-inch Form Factor 15mm Z-height 8639-compatible connector – AIC Form Factor Half-height, Half-length Single slot x4 connector PCIe* Gen3 X4 Performance1,2 – Seq R/W: Up to 2800/2000MB/s3 – IOPS Rnd 4KB4 70/30 R/W: Up to 265K – IOPS Rnd 4KB4 R/W: Up to 460/175K – Seq Latency (typ) R/W: 20/20µs Operating System Support: – Windows* Server 2012 R2, 2012, 2008 R2 x64 – Windows* 7, Windows* 8, Windows* 8.1 (32/64bit) – RHEL* 6.5, 7.0 – SLES11 SP3* – UEFI 2.3.1* Reliability – Uncorrectable Bit Error Rate (UBER): 1 sector per 1017 bits read – Mean Time Before Failure (MTBF): 2 million hours – T10 DIF protection – Variable Sector Size: 512, 520, 528, 4096, 4104, 4160, 4224 Bytes Compliance – NVM Express* 1.0 – PCI Express* Base Specification Rev 3.0 – Enterprise SSD Form Factor Version 1.0a – PCI Express Card Electro-Mechanical (CEM) Specification Rev 2.0 Certifications and Declarations – UL*, CE*, C-Tick*, BSMI*, KCC*, Microsoft* WHQL*, VCCI* 1. 2. 3. 4. 5. 6. 7. Product Specification Power – 2.5-inch: 3.3V and 12V Supply Rail – AIC: 3.3V and 12V Supply Rail – Enhanced power-loss data protection – Active/Idle (TYP): Up to 25W/4W (TYP) Endurance Rating – Up to 36.5 PBW (Petabytes Written)5 10 Drive Writes/day (JESD219 workload) Temperature Specification – Operating: AIC: 0 to 55° C ambient with specified airflow 2.5-inch: 0 to 35° C ambient, 0 to 70° C case with specified airflow – Non-Operating6: -55 to 95° C – Temperature monitoring (In-band and by way of SMBUS) – Thermal throttling when approaching maximum operating temperature Airflow – AIC (55° C airflow towards IO bracket7) 400GB: 200 LFM 800GB, 1.6TB, 2.0TB: 300 LFM – 2.5-inch (Airflow towards the connector) 400GB: 250/300 LFM (25/35° C) 800GB: 350/500 LFM (25/35° C) 1.6TB, 2TB:450/600 LFM (25/35° C) Weight – AIC: 400/800GB up to 185gm 1.6TB, 2TB up to 195gm – 2.5-inch: 400/800GB up to 115gm 1.6TB, 2TB up to 125gm Shock – 2.5-inch: 1,000 G/0.5msec – AIC: 50 G Trapezoidal, 170 in/s Vibration – Operating: 2.17 GRMS (5-700Hz) – Non-Operating: 3.13 GRMS (5-800Hz) Altitude (Simulated) – Operating: -1,000 to 10,000 ft – Non-Operating: -1,000 to 40,000 ft Product Ecological Compliance – RoHS Performance values vary by capacity and form factor Performance specifications apply to both compressible and incompressible data MB/s = 1,000,000 bytes/second 4KB = 4,096 bytes; 8KB = 8,192 bytes 1PB = 1015 Bytes Please contact your Intel representative for details on the non-operating temperature range Airflow out of server through PCIe Card Slot Order Number: 330566-005US Intel® Solid-State Drive DC P3700 Series Ordering Information Contact your local Intel sales representative for ordering information. INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT AS PROVIDED IN INTEL'S TERMS AND CON-DITIONS OF SALE FOR SUCH PRODUCTS, INTEL ASSUMES NO LIABILITY WHATSOEVER AND INTEL DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF INTEL PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. UNLESS OTHERWISE AGREED IN WRITING BY INTEL, THE INTEL PRODUCTS ARE NOT DESIGNED NOR INTENDED FOR ANY APPLICATION IN WHICH THE FAILURE OF THE INTEL PRODUCT COULD CREATE A SITUATION WHERE PERSONAL INJURY OR DEATH MAY OCCUR. Intel may make changes to specifications and product descriptions at any time, without notice. Designers must not rely on the absence or characteristics of any features or instructions marked "reserved" or "undefined." Intel reserves these for future definition and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to them. The information here is subject to change without notice. Do not finalize a design with this information. The products described in this document may contain design defects or errors known as errata which may cause the product to deviate from published specifications. Current characterized errata are available on request. Contact your local Intel sales office or your distributor to obtain the latest specifications and before placing your product order. This document contains information on products in the design phase of development. Copies of documents which have an order number and are referenced in this document, or other Intel literature, may be obtained by calling 1-800-548-4725, or go to: http://www.intel.com/design/literature.htmIntel and the Intel logo are trademarks of Intel Corporation in the U.S. and other countries. *Other names and brands may be claimed as the property of others. Copyright © 2014 Intel Corporation. All rights reserved. Product Specification 2 October 2014 330566-005US Intel® Solid-State Drive DC P3700 Series Contents 1 Overview ................................................................................................................................................................................................................... 7 1.1 1.2 2 References ................................................................................................................................................................................................. 8 Terms and Acronyms............................................................................................................................................................................ 9 Product Specifications .................................................................................................................................................................................... 10 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9 2.10 2.11 Capacity ................................................................................................................................................................................................... 10 Performance .......................................................................................................................................................................................... 10 Electrical Characteristics .................................................................................................................................................................. 12 Environmental Conditions .............................................................................................................................................................. 14 Product Regulatory Compliance .................................................................................................................................................. 15 Reliability Specifications .................................................................................................................................................................. 16 Temperature Sensor .......................................................................................................................................................................... 16 Power Loss Capacitor Test .............................................................................................................................................................. 16 Hot Plug Support ................................................................................................................................................................................. 16 Out of Band Management (SMBUS) ............................................................................................................................................ 17 Variable Sector Size Support ......................................................................................................................................................... 17 3 Mechanical Information .................................................................................................................................................................................. 18 4 Pin and Signal Descriptions .......................................................................................................................................................................... 20 4.1 4.2 5 2.5-inch Form Factor Pin Locations ............................................................................................................................................ 20 Pin Signal Definitions......................................................................................................................................................................... 20 Supported Command Sets............................................................................................................................................................................ 23 5.1 5.2 5.3 5.4 5.5 5.6 5.7 NVMe* Admin Command Set ......................................................................................................................................................... 23 NVMe I/O Command Set .................................................................................................................................................................. 23 Log Page Support ................................................................................................................................................................................ 24 SMART Attributes ................................................................................................................................................................................ 24 Temperature Statistics ...................................................................................................................................................................... 27 Drive Marketing Name Log .............................................................................................................................................................. 27 SET Feature Identifiers...................................................................................................................................................................... 27 6 NVMe Driver Support ...................................................................................................................................................................................... 29 7 Certifications and Declarations ................................................................................................................................................................... 30 Appendix A IDENTIFY Data Structure ........................................................................................................................................................ 31 Appendix B Vital Data Structure ................................................................................................................................................................... 39 Appendix C Out of Band Temperature Sensor Read Out ................................................................................................................. 40 Appendix D PCIe ID ............................................................................................................................................................................................. 41 Appendix E SCSI Command Translation .................................................................................................................................................. 42 Appendix F Add-in Card LED Decoder ...................................................................................................................................................... 43 Figures October 2014 330566-005US Product Specification 3 Intel® Solid-State Drive DC P3700 Series Figure 3-1: Figure 3-2: Figure 4-1: Figure A-1: Intel SSD DC P3700 Series SFF Dimensions ....................................................................................................................... 18 Intel SSD DC P3700 Series PCIe Dimensions ..................................................................................................................... 19 2.5-inch Form Factor Pin Locations ........................................................................................................................................ 20 LED Location ...................................................................................................................................................................................... 43 Tables Table 1: Table 2: Table 3: Table 4: Table 5: Table 6: Table 7: Table 8: Table 9: Table 10: Table 11: Table 12: Table 13: Table 14: Table 15: Table 16: Table 17: Table 18: Table 19: Table 20: Table 21: Table 22: Table 23: Table 24: Table 25: Table 26: Table 27: Table 28: Table 29: Table 30: Table 31: Table 32: Table 33: Table 34: Table 35: Table 36: Table 37: Standard Information referenced in this document .............................................................................................................. 8 Glossary of Terms and Acronyms ................................................................................................................................................... 9 User Addressable Sectors ............................................................................................................................................................... 10 Random Read/Write Input/Output Operations Per Second (IOPS) ............................................................................. 10 Random Read/Write IOPS Consistency .................................................................................................................................... 11 Sequential Read and Write Bandwidth ..................................................................................................................................... 11 Latency ..................................................................................................................................................................................................... 11 Quality of Service ................................................................................................................................................................................ 12 Operating Voltage ............................................................................................................................................................................... 12 Power Consumption .......................................................................................................................................................................... 13 Temperature, Shock, Vibration ..................................................................................................................................................... 14 Airflow Requirements for Intel SSD DC P3700 Series (Add-In Card) .......................................................................... 14 Airflow Requirements for Intel SSD DC P3700 Series (2.5-inch Form Factor) ....................................................... 15 Product Regulatory Compliance Specifications .................................................................................................................... 15 Reliability Specifications .................................................................................................................................................................. 16 Pin Definition for 2.5-inch Form Factor (8639 connector specification) ................................................................... 20 Pin Definition for Add-In Card (Half Height Half Length) Form Factor ....................................................................... 22 SMART Attributes (Log Identifier 02h) ...................................................................................................................................... 24 Additional SMART Attributes (Log Identifier CAh) ............................................................................................................... 26 Temperature Statistics (Log Identifier C5h) ............................................................................................................................ 27 Drive Marketing Name Log (Log Identifier DDh) ................................................................................................................... 27 Set Max LBA Setting - Command Dword 11 and Command Dword 12 ..................................................................... 28 Status Code - Set Max LBA Command Specific Status Values ....................................................................................... 28 C6h - Set/Get Power Governor Setting – Command Dword 11 .................................................................................... 28 Status Codes - Power Governor Setting Command Specific Status Values ............................................................ 28 D5h – Reset Timed Workload Counters – Command Dword 11 ................................................................................... 28 NVMe Driver Support ........................................................................................................................................................................ 29 Device Certifications and Declarations ...................................................................................................................................... 30 Identify Controller ............................................................................................................................................................................... 31 Power State Descriptor ..................................................................................................................................................................... 35 Identify Namespace ............................................................................................................................................................................ 36 LBA Format Data Structure ............................................................................................................................................................. 38 Vital Product Data Structure (VPD) ............................................................................................................................................. 39 Capability List Pointer (Out of Band Temperature Sensor) ............................................................................................. 39 Register 0x05 read out format ...................................................................................................................................................... 40 PCIe ID ...................................................................................................................................................................................................... 41 LED Functionality................................................................................................................................................................................. 43 Product Specification 4 October 2014 330566-005US Intel® Solid-State Drive DC P3700 Series Revision History Revision Number 001 002 003 004 Description Revision Date June 2014 Initial release Driver and temperature updates July 2014 Updated performance information Updated power number for 400GB September 2014 Update driver/OS support list September 2014 Endurance rating corrected Added clarification in SMART critical warning 005 October 2014 Corrected error is QoS percentile Modified power governor setting target for 01 and 02 § October 2014 330566-005US Product Specification 5 Intel® Solid-State Drive DC P3700 Series This page intentionally left blank. Product Specification 6 October 2014 330566-005US Intel® Solid-State Drive DC P3700 Series 1 Overview This document describes the specifications and capabilities of the Intel® Solid-State Drive (SSD) Data Center P3700 Series. P3700 Series is a PCIe Gen3 SSD architected with the new high performance controller interface – NVMe (Non-Volatile Memory express) delivering leading performance, low latency and Quality of Service. Matching the performance with world-class reliability and endurance, P3700 Series offers a range of capacity – 400GB, 800GB, 1.6TB and 2TB in both Add-In card and 2.5-inch form factor. With PCIe Gen3 support and NVMe queuing interface, the P3700 Series delivers excellent sequential read performance of up to 2.8GB/s and sequential write speeds of up to 2.0GB/s. P3700 Series delivers very high random read IOPS of 460K and random write IOPS of 175K for 4KB operations. Taking advantage of the direct path from the storage to the CPU by means of NVMe, P3700 Series exhibits low latency of less than 20 μs for sequential access to the SSD. P3700 Series also includes High Endurance Technology (HET), which combines NAND silicon enhancements and SSD NAND management techniques to extend SSD write endurance up to 10 drive writes per day for 5 years. The 2.5-inch P3700 Series takes advantage of the 8639 connector and provides hot-pluggable removal and insertion providing in-service replacement options. P3700 Series includes these key features: Consistently High IOPS and throughput Sustained low latency High Endurance Technology (HET) Variable Sector Size and End-to-End data-path protection Enhanced power-loss data protection Power loss protection capacitor self-test Out of band management Thermal throttling and monitoring October 2014 330566-005US Product Specification 7 Intel® Solid-State Drive DC P3700 Series 1.1 References Table 1: Standard Information referenced in this document Date Title Location Jan 2013 Enterprise SSD Form Factor Version 1.0a http://www.ssdformfactor.org Feb 2012 NVMe Revision 1.0c http://www.nvmexpress.org Nov 2010 PCIe Base Specification Revision 3.0 http://pcisig.com July 2012 Solid-State Drive (SSD) Requirements and Endurance Test Method (JESD219) http://www.jedec.org/standardsdocuments/results/jesd219 Sept 2010 Solid-State Drive (SSD) Requirements and Endurance Test Method (JESD218) http://www.jedec.org/standardsdocuments/docs/jesd218/ Dec 2008 VCCI http://www.vcci.jp/vcci_e/ RoHS http://qdms.intel.com/ Click Search MDDS Database and search for material description datasheet International Electrotechnical Commission EN 61000 4-2 (Electrostatic discharge immunity test) 4-3 (Radiated, radio-frequency, electromagnetic field immunity test) 4-4 (Electrical fast transient/burst immunity test) 4-5 (Surge immunity test) 4-6 (Immunity to conducted disturbances, induced by radiofrequency fields) 4-11 (Voltage Variations, voltage dips, short interruptions and voltage variations immunity tests) http://www.iec.ch/ ENV 50204 (Radiated electromagnetic field from digital radio telephones) http://www.dbicorporation.com/ radimmun.htm/ June 2009 1995 1996 1995 1995 1997 1994 1995 Product Specification 8 October 2014 330566-005US Intel® Solid-State Drive DC P3700 Series 1.2 Terms and Acronyms Table 2: Glossary of Terms and Acronyms Term Definition ATA Advanced Technology Attachment CRC Cyclic Redundancy Check DAS Device Activity Signal DMA Direct Memory Access ECC Error Correction Code EEPROM EXT FPDMA Electrically Erasable Programmable Read Only Memory Extended First Party Direct Memory Access GB Gigabyte Note: The total usable capacity of the SSD may be less than the total physical capacity because a small portion of the capacity is used for NAND flash management and maintenance purposes. Gb Gigabit HDD Hard Disk Drive HET High Endurance Technology KB Kilobyte I/O Input/Output IOPS Input/Output Operations Per Second ISO International Standards Organization LBA Logical Block Address MB Megabyte (1,000,000 bytes) MLC Multi-level Cell MTBF Mean Time Between Failures NOP No Operation NVMe PB Non-Volatile Memory Express Petabyte PCB Printed Circuit Board RDT Reliability Demonstration Test RMS Root Mean Square SSD Solid-State Drive TB Terabyte TYP Typical UBER Uncorrectable Bit Error Rate VPD Vital Product Data § October 2014 330566-005US Product Specification 9 Intel® Solid-State Drive DC P3700 Series 2 Product Specifications 2.1 Capacity Table 3: User Addressable Sectors Intel SSD DC P3700 Series Unformatted Capacity (Total User Addressable Sectors in LBA Mode) 400GB 781,422,768 800GB 1,562,824,368 1.6TB 3,125,627,568 2TB 3,907,029,168 NOTES: 1 GB = 1,000,000,000 bytes; 1 sector = 512 bytes or 520 bytes or 528 bytes. LBA count shown represents total user storage capacity and will remain the same throughout the life of the drive. The total usable capacity of the SSD may be less than the total physical capacity because a small portion of the capacity is used for NAND media management and maintenance. IDEMA or JEDEC standard is used. 2.2 Performance Table 4: Random Read/Write Input/Output Operations Per Second (IOPS) Specification1 Unit Random 4KB 70/30 Read/Write (up to) 2 Intel SSD DC P3700 Series 400GB 800GB 1.6TB 2TB IOPS 150,000 200,000 240,000 265,000 Random 8KB 70/30 Read/Write (up to) 3 IOPS 75,000 100,000 140,000 150,000 Random 4KB Read (up to)2 IOPS 450,000 460,000 450,000 450,000 Random 4KB Write (up to) IOPS 75,000 90,000 150,000 175,000 Random 8KB Read (up to)3 IOPS 275,000 285,000 290,000 295,000 Random 8KB Write (up to) IOPS 32,000 45,000 75,000 90,000 NOTES: 1. Performance measured using IOMeter* on Windows* Server 2012 R2 driver with Queue Depth 32 and 4 workers. Measurements are performed on a full Logical Block Address (LBA) span of the drive. Power mode set at 25W. 2. 4KB = 4,096 bytes 3. 8KB = 8,192 bytes Product Specification 10 October 2014 330566-005US Intel® Solid-State Drive DC P3700 Series Table 5: Random Read/Write IOPS Consistency Specification Unit Intel SSD DC P3700 Series 400GB 800GB 1.6TB 2TB Random 4KB Read (up to)2 % 90 90 90 90 Random 4KB Write (up to) % 90 90 90 90 Random 8KB Read (up to)3 % 90 90 90 90 Random 8KB Write (up to) % 90 90 90 90 NOTES: 1. Performance consistency measured using IOMeter* based on Random 4KB with total queue depth of 128, measured as (IOPS in the 99.9th percentile slowest 1-second interval)/(average IOPS during the test). Measurements are performed on a full Logical Block Address (LBA) span of the drive once the workload has reached steady state but including all background activities required for normal operation and data reliability 2. 4KB = 4,096 bytes 3. 8KB = 8,192 bytes Table 6: Sequential Read and Write Bandwidth Specification Intel SSD DC P3700 Series Unit 400GB 800GB 1.6TB 2TB Sequential Read (up to)1 MB/s 2,700 2,800 2,800 2,800 Sequential Write (up to)1 MB/s 1,080 1,900 1,900 2,000 NOTES: 1. Performance measured using IOMeter* with 128 KB (131,072 bytes) of transfer size with Queue Depth 128. Power mode set at 25W. Table 7: Latency Specification Intel SSD DC P3700 Series Latency1 (TYP) Read Sequential/Random Write Sequential/Random Power On to Ready2 20/115 µs 20/25 µs 2.0 sec (TYP) NOTES: 1. Device measured using IOMeter. Latency measured using 4 KB (4,096 bytes) transfer size with Queue Depth equal to 1 on a sequential workload using Windows Server 2012 R2 driver. Power mode set at 25W. 2. Power On To Ready time measured from de-assertion of PCIe reset to first interface response. Exception handling like unsafe power shutdown will not be part of this specification. For unsafe shutdown, the time to ready can be up to 10 seconds (TYP). October 2014 330566-005US Product Specification 11 Intel® Solid-State Drive DC P3700 Series Table 8: Quality of Service Specification Unit Intel SSD DC P3700 Series QD = 1 QD = 128 Quality of Service1,2 (99%) Reads ms 0.600 2 Writes ms 0.090 11 Reads ms 4 5 Writes ms 2 30 Quality of Service1,2 (99.99%) NOTES: 1. Device measured using IOMeter. Quality of Service measured using 4KB (4,096 bytes) transfer size on a random workload on a full Logical Block Address (LBA) span of the drive once the workload has reached steady state but including all background activities required for normal operation and data reliability. 2. Based on Random 4KB QD=1,128 workloads, measured as the time taken for 99.0(or 99.99) percentile of commands to finish the round-trip from host to drive and back to host. 2.3 Electrical Characteristics Table 9: Operating Voltage Electrical Characteristics 3.3V Operating Characteristics: (Add-in Card only) Operating Voltage range Rise time (Max/Min) Fall time (Max/Min)1 Noise level Min Off time2 Inrush Current (Typical Peak) 3 Max Average Current 12V Operating Characteristics: Operating Voltage range Rise time (Max/Min) Fall time (Max/Min)1 Noise level Min Off time2 Inrush Current (Typical Peak) 3 Max Average Current Product Specification 12 Intel SSD DC P3700 Series 3.3 V (±10%) 50ms/1ms 5s/1ms 300 mV pp 10Hz – 100 KHz 50 mV pp 100KHz – 20 MHz 3 seconds 1.5 A 3.0 A 12 V (+10%/-20%) 50ms/1ms 5s/1ms 1000 mV pp 10Hz – 100 KHz 100 mV pp 100KHz – 20 MHz 3 seconds 1.5 A 2.1 A/ 2.45 A (Add-in Card/ 2.5-inch FF) October 2014 330566-005US Intel® Solid-State Drive DC P3700 Series Electrical Characteristics Intel SSD DC P3700 Series 3.3Vaux Operating Characteristics: Operating Voltage range Rise time (Max/Min) Fall time (Max/Min)1 Noise level 3.3 V (±9%) 50ms/1ms 5s/1ms 300 mV pp 10Hz – 100 KHz 50 mV pp 100KHz – 20 MHz 20mA/1mA (AIC/2.5-inch FF) Max Current Notes: 1. 2. 3. Fall time needs to be equal or better than minimum in order to guarantee full functionality of enhanced power loss management. The drive must be powered off for at least 500msec before powering on. Measured during initial power supply application. Typically this will be seen within 2 seconds of initial power up. Inrush specified for 12V and 3.3V supply, not the 3.3Vaux. Note: 3.3Vaux is optional, not needed for power up or functionality. 3.3Vaux is needed for accessing VPD page by means of SMBUS for both form factors. Table 10: Power Consumption Specification Unit Intel SSD DC P3700 Series 400GB 800GB 1.6TB 2TB W 12 18 22 25 Active Read - Average W 9 9 10 11 Idle W 4 4 4 4 1 2 Active Write - Average Notes: 1. 2. The workload equates 128KB (131,072 bytes) Queue Depth equal to 128 sequential writes. Average power is measured using scope trigger over a 100 ms sample period. The workload equates 128KB (131,072 bytes) Queue Depth equal to 128 sequential reads. October 2014 330566-005US Product Specification 13 Intel® Solid-State Drive DC P3700 Series 2.4 Environmental Conditions Table 11: Temperature, Shock, Vibration Temperature Temperature Operating1 Non-operating3 Temperature Gradient4 Operating Non-operating Add-In card form factor 2.5-inch form factor Ambient: 0 – 55o C / 0 -40 oC2 -55–95o C Ambient: 0–35o C, Case: 0-70o C 30o C/hr (Typical) 30o C/hr (Typical) 30o C/hr (Typical) 30o C/hr (Typical) 5–95% 5–95% 5–95% 5–95% Humidity Operating Non-operating Shock and Vibration Range Shock5 Operating Non-operating 50 G Trapezoidal, 170 in/s 50 G Trapezoidal, 170 in/s 1,000 G (Max) at 0.5 msec 1,000 G (Max) at 0.5 msec Vibration6 Operating Non-operating 2.17 GRMS (5-700 Hz) Max 3.13 GRMS (5-800 Hz) Max 2.17 GRMS (5-700 Hz) Max 3.13 GRMS (5-800 Hz) Max Notes: 1. 2. 3. 4. 5. 6. Operating temperature implies ambient air temperature under defined airflow in Tables 12 and 13. 0-55o C is for airflow from the server towards the card and 0-40o C is for airflow into the server. Please contact your Intel representative for details on the non-operating temperature range. Temperature gradient measured without condensation. Shock specifications assume the SSD is mounted securely with the input vibration applied to the drive-mounting screws. Stimulus may be applied in the X, Y or Z axis. Shock specification is measured using Root Mean Squared (RMS) value. Vibration specifications assume the SSD is mounted securely with the input vibration applied to the drive-mounting screws. Stimulus may be applied in the X, Y or Z axis. Vibration specification is measured using RMS value. Table 12: Airflow Requirements for Intel SSD DC P3700 Series (Add-In Card) Airflow Direction Unit Towards the server LFM Out of the server LFM NOTE: Ambient Temperature Intel SSD DC P3700 Series 400GB 800GB 1.6TB 2TB 40o C 200 300 300 300 55o C 200 300 300 300 For Add-In cards airflow can be for both the directions. Airflow specified is based on approach velocity. Product Specification 14 October 2014 330566-005US Intel® Solid-State Drive DC P3700 Series Table 13: Airflow Requirements for Intel SSD DC P3700 Series (2.5-inch Form Factor) Airflow Definition Airflow Along Drive1 Approach Airflow2 NOTE: 1. 2. 2.5 Unit Ambient Temperature Intel SSD DC P3700 Series 400GB 800GB 1.6TB 2TB LFM 35o C 300 500 650 650 LFM 25o C 250 350 450 450 LFM 35o C 70 120 155 155 LFM 25o C 60 85 110 110 It is recommended that airflow for 2.5-inch form factor should be towards the server, from the non-connector side to the connector side. Airflow is specified across the surface of the drive. Spacing between two SSDs is assumed to be 3mm. The approach velocity of the airflow will be less than the airflow along the surface. Approach area of 1.35 ft2 is assumed. Product Regulatory Compliance Intel SSD DC P3700 Series meets or exceeds the following regulatory or certification requirements. Table 14: Product Regulatory Compliance Specifications Title TITLE 47-Telecommunications CHAPTER 1 – FEDERAL COMMUNMICATIONS COMMISSION PART 15 – RADIO FREQUENCY DEVICES ICES*-003, Issue 4 Interference-Causing Equipment Standard Digital Apparatus Description FCC Part 15B Class A Region For Which Conformity Declared USA CA/CSA-CEI/IEC CISPR 22:10. This is CISPR 22:2008 with Canadian Modifications Canada IEC* 55024 Information Technology Equipment – Immunity characteristics – Limits and methods of measurement CISPR24:2010 EN-55024: 2010 and its amendments European Union IEC 55022 Information Technology Equipment – Radio disturbance Characteristics – Limits and methods of measurement CISPR24:2008 (Modified) EN-55022: 2010 and its amendments European Union EN-60950-1 2nd Edition Information Technology Equipment – Safety – Part 1: General Requirements USA/Canada UL/CSA EN-60950-1 2nd Edition Information Technology Equipment – Safety – Part 1: General Requirements USA/Canada October 2014 330566-005US Product Specification 15 Intel® Solid-State Drive DC P3700 Series 2.6 Reliability Specifications Intel SSD DC P3700 Series meets or exceeds SSD endurance and data retention requirements as specified in the JESD218 standard. Reliability specifications are listed in the following table. Table 15: Reliability Specifications Parameter Value Uncorrectable Bit Error Rate (UBER) Uncorrectable bit error rate will not exceed one sector in the specified number of bits read. In the unlikely event of a nonrecoverable read error, the SSD will report it as a read failure to the host; the sector in error is considered corrupt and is not returned to the host. < 1 sector per 1017 bits read Mean Time Between Failures (MTBF) Mean Time Between Failures is estimated based on Telcordia* methodology and demonstrated through Reliability Demonstration Test (RDT). 2 million hours Data Retention The time period for retaining data in the NAND at maximum rated endurance. Endurance Rating The number of drive writes such that the SSD meets the requirements according to the JESD218 standard. Endurance rating verification is defined to establish UBER <1E-16 at 60% upper confidence limit. 3 months power-off retention once SSD reaches rated write endurance at 40° C 400GB: 7.3 PBW 800GB: 14.6 PBW 1.6TB: 29.2 PBW 2.0TB: 36.5 PBW (10 drive writes/day*) Note: Petabytes Written (PBW). Refer to JESD218 standard table 1 for UBER, FFR and other Enterprise SSD requirements. 2.7 Temperature Sensor P3700 Series has an internal temperature sensor with an accuracy of +/-2C over a range of -10C to +85C which can be monitored using NVMe Health Log. For more information on sensor reading see SMART attributes section. In addition, drive will provide out of band access to temperature by means of SMBUS. The sensor has an accuracy of +/- 3C over a range of -20C to 125C. SMBUS temperature sensor will not be reported in NVMe Health Log. 2.8 Power Loss Capacitor Test P3700 Series supports testing of the power loss capacitor, which can be monitored using SMART attribute critical warning in log page identifier 02h, byte 0, bit 4. 2.9 Hot Plug Support 2.5-inch form factor will support surprise hot plug feature in capable platforms and OSs. P3700 Series supports hot insertion and removal and surprise hot insertion by means of presence detect and link-up detect. On surprise hot removal during IOs, P3700 Series will ensure the integrity of already committed data on the media and commit acknowledged writes to the media. Product Specification 16 October 2014 330566-005US Intel® Solid-State Drive DC P3700 Series 2.10 Out of Band Management (SMBUS) Intel SSD DC P3700 Series provides out of band management by means of SMBUS interface. This requires 3.3V Auxiliary voltage. SMBUS accesses a VPD page as listed in Appendix B through address 0X53. Temperature sensor is accessed through address 0x1B. For temperature sensor access, temperature can be read by the BMC (base) using Read Temperature Data Register (0x05) by means of SMBUS 0x1B. Bits [11:0] return raw ambient temperature. Host may also see 0x66 address in a bus scan. This is only used for write protecting the EEPROM during manufacturing. Note: In certain tools the address for the VPD and temperature sensor will appear as 0xA6 and 0x36 respectively, due to bit shift. 2.11 Variable Sector Size Support P3700 Series supports 512, 520, 528, 4096, 4104, 4160 and 4224 bytes of sector size. P3700 Series will also support DIF as specified in NVMe 1.0 specification. Host sector sizes supporting DIF are 512 bytes and 4096 bytes with a PI (Protection Information) of 8 bytes. In terms of protection information action (PRACT), bit 29 of DWORD12 in READ/WRITE command should not be equal to 1. Device only supports PRACT=0 implying protection information is passed to the SSD and checked by the SSD. § October 2014 330566-005US Product Specification 17 Intel® Solid-State Drive DC P3700 Series 3 Mechanical Information Figures 3-1 and 3-2 show the physical package information for the Intel SSD DC P3700 Series in the 2.5-inch form factors. All dimensions are in millimeters. Figure 3-1: Intel SSD DC P3700 Series SFF Dimensions X – Length Y - Width Z - Height 100.45 Max 69.85 +/- 0.25 15.0 +0/-0.5 Note: Length does not include 0.3 connector protrusion Product Specification 18 October 2014 330566-005US Intel® Solid-State Drive DC P3700 Series Figure 3-2: Intel SSD DC P3700 Series PCIe Dimensions § October 2014 330566-005US Product Specification 19 Intel® Solid-State Drive DC P3700 Series 4 Pin and Signal Descriptions 4.1 2.5-inch Form Factor Pin Locations Figure 4-1: 2.5-inch Form Factor Pin Locations Note: 2.5-inch connector supports built in latching capability. 4.2 Pin Signal Definitions Table 16: Pin Definition for 2.5-inch Form Factor (8639 connector specification) Pin S1 Name GND Description Pin Name Description Ground E7 REFCLK0+ Reference clock port 0 Not used (SATA/SAS) E8 REFCLK0- Reference clock port 0 Not used (SATA/SAS) E9 GND Ground Ground E10 PETp0 Transmitter differential pair, Lane 0 S5 Not used (SATA/SAS) E11 PETn0 Transmitter differential pair, Lane 0 S6 Not used (SATA/SAS) E12 GND Ground GND Ground E13 PERn0 Receiver differential pair, Lane 0 E1 REFCLK1+ Reference clock port 1 (not used) E14 PERp0 Receiver differential pair, Lane 0 E2 REFCLK1- Reference clock port 1 (not used) E15 GND Ground E3 3.3Vaux 3.3V auxiliary power E16 RSVD Reserved E4 PERST1# Fundamental reset port 1 (not used) S8 GND Ground E5 PERST0# Fundamental reset port 0 S9 Not used (SATAe/SAS) E6 RSVD Reserved S10 Not used (SATAe/SAS) P1 Not used (SATAe/SAS) S11 P2 Not used (SATAe/SAS) S12 S2 S3 S4 S7 GND Product Specification 20 GND Ground Not used (SATAe/SAS) October 2014 330566-005US Intel® Solid-State Drive DC P3700 Series Pin Name P3 Description Pin Not used (SATAe) S13 Name Description Not used (SATAe/SAS) P4 IfDet_N Interface detect (drive type) S14 GND Ground P5 GND Ground S15 RSVD Reserved P6 GND Ground S16 GND Ground P7 Not used (SATA/SAS) S17 PETp1 Transmitter differential pair, Lane 1 P8 Not used (SATA/SAS) S18 PETn1 Transmitter differential pair, Lane 1 P9 Not used (SATA/SAS) S19 GND Ground P10 PRSNT_N Presence detect (also used for drive type) S20 PERn1 Receiver differential pair, Lane 1 P11 Activity Activity signal from the drive S21 PERp1 Receiver differential pair, Lane 1 P12 Hot-Plug Ground S22 GND Ground P13 +12V_pre 12V power S23 PETp2 Transmitter differential pair, Lane 2 P14 +12V 12V power S24 PETn2 Transmitter differential pair, Lane 2 P15 +12V 12V power S25 GND Ground S26 PERn2 Receiver differential pair, Lane 2 S27 PERp2 Receiver differential pair, Lane 2 S28 GND Ground E17 PETp3 Transmitter differential pair, Lane 3 E18 PETn3 Transmitter differential pair, Lane 3 E19 GND Ground E20 PERn3 Receiver differential pair, Lane 3 E21 PERp3 Receiver differential pair, Lane 3 E22 GND Ground E23 SMCLK SMBus clock E24 SMDAT SMBus data E25 DualPortEn_N Dual port enable NOTES: SMCLK and SMDAT routes to an internal EEPROM which contains Vital Product Data (VPD). PRSNT_N is kept open by the P3700 Series. IfDet_N is grounded by P3700 Series. DualPortEn_N pin should be left un-connected or un-driven by the system to enable single port operation with all 4 lanes. If un-connected, P3700 Series will pull it high. However, if the pin is asserted by the system (driven low by storage backplane), then P3700 Series will be configured as x2 lanes. P11 is used for activity. When idle, logic level is low (LED Solid On). During IO activity and formatting, pin toggles 250msec high, 250msec low signal. P3700 Series only uses REFCLK0+ and REFCLK0- as reference clock pair. P3700 Series only uses PERST0# as a fundamental reset. 3.3Vaux is only needed during SMBUS access to the VPDROM. October 2014 330566-005US Product Specification 21 Intel® Solid-State Drive DC P3700 Series Table 17: Pin Definition for Add-In Card (Half Height Half Length) Form Factor Side B Pin Name Side A Description Name Description 1 +12V 12V power PRSNT1# Hot-Plug presence detect 2 +12V 12V power +12V 12V power 3 +12V 12V power +12V 12V power 4 GND Ground GND Ground 5 SMCLK SMBus(System Management Bus) clock JTAG2 TCK (Test Clock), clock input for JTAG interface 6 SMDAT SMBus (System Management Bus) data JTAG3 TDI (Test Data Input) 7 GND Ground / UART_HOST JTAG4 TDO (Test Data Output) 8 +3.3V 3.3V power JTAG5 TMS (Test Mode Select) 9 JTAG1 TRST# (Test Reset) resets the JTAG interface +3.3V 3.3V power 10 3.3Vaux 3.3V auxiliary power +3.3V 3.3V power 11 WAKE# Signal for Link reactivation PERST# Fundamental reset Mechanical Key 12 RSVD Reserved GND Ground 13 GND Ground REFCLK+ Reference clock (differential pair) 14 PETp0 Transmitter differential pair, Lane 0 REFCLK- Reference clock (differential pair) 15 PETn0 Transmitter differential pair, Lane 0 GND Ground 16 GND Ground PERp0 Receiver differential pair, Lane 0 17 PRSNT2# Hot-Plug presence detect PERn0 Receiver differential pair, Lane 0 18 GND Ground GND Ground End of the x1 Connector 19 PETp1 Transmitter differential pair, Lane 1 RSVD Reserved 20 PETn1 Transmitter differential pair, Lane 1 GND Ground 21 GND Ground PERp1 Receiver differential pair, Lane 1 22 GND Ground PERn1 Receiver differential pair, Lane 1 23 PETp2 Transmitter differential pair, Lane 2 GND Ground 24 PETn2 Transmitter differential pair, Lane 2 GND Ground 25 GND Ground PERp2 Receiver differential pair, Lane 2 26 GND Ground PERn2 Receiver differential pair, Lane 2 27 PETp3 Transmitter differential pair, Lane 3 GND Ground 28 PETn3 Transmitter differential pair, Lane 3 GND Ground 29 GND Ground PERp3 Receiver differential pair, Lane 3 30 RSVD Reserved PERn3 Receiver differential pair, Lane 3 31 PRSNT2# Hot-Plug presence detect GND Ground 32 GND Ground RSVD Reserved End of the x4 Connector NOTES: All pins are numbered in ascending order from the left to the right, with side A on the top of the centerline and side B on the bottom of the centerline, use the reference drawing in Fig2, with the logo visible. The PCI Express interface pins PETpx, PETnx, PERpx, and PERnx are named with the following convention: “PE” stands for PCI Express high speed, “T” for Transmitter, “R” for Receiver, “p” for positive (+) and “n” for negative (-). The sequential mating for Hot-Plug is accomplished by staggering the edge fingers on the add-in card. § Product Specification 22 October 2014 330566-005US Intel® Solid-State Drive DC P3700 Series 5 Supported Command Sets Intel SSD DC P3700 Series supports all mandatory Admin and I/O commands defined in NVMe (Non-Volatile Memory Express) revision 1.0. 5.1 NVMe Admin Command Set P3700 Series supports all mandatory NVMe commands, which consists of: Delete I/O Submission Queue Delete I/O Completion Queue Create I/O Submission Queue Create I/O Completion Queue Get Log Page Identify Abort SET Features GET Features Asynchronous Event Notification P3700 Series also supports the following optional I/O commands defined in NVMe revision 1.0: Firmware Activate Firmware Image Download Format NVM Note: 5.2 See Appendix A, “Identify Controller Data Structure” for details on commands and capabilities. NVMe I/O Command Set P3700 Series supports all the mandatory NVMe I/O command set defined in NVMe 1.0 specification, which consists of: Flush Write Read Additionally, the following optional commands are supported: Write Uncorrectable Dataset Management (De-allocate only) Note: See Appendix E, “SCSI Command Translation Table” for details on SCSI supported commands and capabilities. October 2014 330566-005US Product Specification 23 Intel® Solid-State Drive DC P3700 Series 5.3 Log Page Support Intel SSD DC P3700 Series supports the following mandatory log pages defined in NVMe 1.0 specification: Error Information (Log Identifier 01h) SMART/ Health Information (Log Identifier 02h) Firmware Slot Information (Log Identifier 03h) Note: See NVMe 1.0 version of the specification for the log page content. Additionally, P3700 Series will support the following vendor unique log pages: 5.4 Log Page Directory (Log Identifier C0h) Temperature Statistics (Log Identifier C5h) Vendor Unique SMART Log (Log Identifier CAh) SMART Attributes The following table lists the SMART attributes supported by the P3700 Series in accordance with NVMe 1.0 specification. Table 18: SMART Attributes (Log Identifier 02h) # of Bytes Attribute Description 0 1 Critical Warning: These bits if set, flag various warning sources. Bit 0: Available Spare is below Threshold Bit 1: Temperature has exceeded Threshold Bit 2: Reliability is degraded due to excessive media or internal errors Bit 3: Media is placed in Read- Only Mode Bit 4: Volatile Memory Backup System has failed (e.g., enhanced power loss capacitor test failure) Bits 5-7: Reserved Any of the critical warning can be tied to asynchronous event notification. Drive Health Indicator defined under bytes 30953076 of Identify Controller may still indicate “healthy” status when the critical warning flag is set. 1 2 Temperature: Overall Device current temperature in Kelvin. For AIC, this reports the NAND temperature, for 2.5-inch FF, this reports the case temperature, 3 1 Available Spare: Contains a normalized percentage (0 to 100%) of the remaining spare capacity available Starts from 100 and decrements. 4 1 Available Spare Threshold Threshold is set to 10%. Percentage Used Estimate (Value allowed to exceed 100%) A value of 100 indicates that the estimated endurance of the device has been consumed, but may not indicate a device failure. The value is allowed to exceed 100. Percentages greater than 254 shall be represented as 255. This value shall be updated once per power-on hour (when the controller is not in a sleep state). Byte 5 1 Product Specification 24 October 2014 330566-005US Intel® Solid-State Drive DC P3700 Series Byte 32 # of Bytes 16 Attribute Description Data Units Read (in LBAs) Contains the number of 512 byte data units the host has read from the controller; this value does not include metadata. This value is reported in thousands (i.e., a value of 1 corresponds to 1000 units of 512 bytes read) and is rounded up. When the LBA size is a value other than 512 bytes, the controller shall convert the amount of data read to 512 byte units. 48 16 Data Units Write (in LBAs) Contains the number of 512 byte data units the host has written to the controller; this value does not include metadata. This value is reported in thousands (i.e., a value of 1 corresponds to 1000 units of 512 bytes written) and is rounded up. When the LBA size is a value other than 512 bytes, the controller shall convert the amount of data written to 512 byte units. For the NVM* command set, logical blocks written as part of Write operations shall be included in this value. Write Uncorrectable commands shall not impact this value. 64 16 Host Read Commands Contains the number of read commands issued to the controller. 80 16 Host Write Commands Contains the number of write commands issued to the controller. 96 16 Controller Busy Time (in minutes) Contains the amount of time the controller is busy with I/O commands. The controller is busy when there is a command outstanding to an I/O Queue (specifically, a command was issued by way of an I/O Submission Queue Tail doorbell write and the corresponding completion queue entry has not been posted yet to the associated I/O Completion Queue). This value is reported in minutes. 112 16 Power Cycles Contains the number of power cycles. 128 16 Power On Hours Contains the number of power-on hours. This does not include time that the controller was powered and in a low power state condition. 144 16 Unsafe shutdowns Contains the number of unsafe shutdowns. This count is incremented when a shutdown notification (CC.SHN) is not received prior to loss of power. 160 16 Media Errors Contains the number of occurrences where the controller detected an unrecovered data integrity error. Errors such as uncorrectable ECC, CRC checksum failure, or LBA tag mismatch are included in this field. 176 16 Number of Error Information Log Entries Contains the number of Error Information log entries over the life of the controller. October 2014 330566-005US Product Specification 25 Intel® Solid-State Drive DC P3700 Series Table 19: Additional SMART Attributes (Log Identifier CAh) Byte # of Bytes 0 1 AB (Program Fail Count) 3 1 Normalized Value 5 6 Current Raw Value 12 1 AC (Erase Fail Count) 15 1 Normalized Value 17 6 Current Raw Value 24 1 AD (Wear Leveling Count) 27 1 Normalized Value 29 6 Current Raw Value 36 1 B8 (End to End Error Detection Count) 39 1 Normalized Value 41 6 Current Raw Value 48 1 C7 (CRC Error Count) 51 1 Normalized Value 53 6 Current Raw Value 60 1 E2 (Timed Workload, Media Wear) 63 1 Normalized Value 65 6 Current Raw Value 72 1 E3 (Timed Workload, Host Reads %) 75 1 Normalized Value 77 6 Current Raw Value 84 1 E4 (Timed Workload, Timer) 87 1 Normalized Value 89 6 Current Raw Value 96 1 EA (Thermal Throttle Status) 99 1 Normalized Value 101 6 Current Raw Value Product Specification 26 Attribute Description Raw value: shows total count of program fails. Normalized value: beginning at 100, shows the percent remaining of allowable program fails. Raw value: shows total count of erase fails. Normalized value: beginning at 100, shows the percent remaining of allowable erase fails. Raw value: Bytes 1-0: Min. erase cycle Bytes 3-2: Max. erase cycle Bytes 5-4: Avg. erase cycles Normalized value: decrements from 100 to 0. Raw value: reports number of End-to-End detected and corrected errors by hardware. Normalized value: always 100. Raw value: shows total number of encountered interface cyclic redundancy check (CRC) errors. Normalized value: always 100. Raw value: measures the wear seen by the SSD (since reset of the workload timer, attribute E4h), as a percentage of the maximum rated cycles. Divide the raw value by 1024 to derive the percentage with 3 decimal points. Normalized value: always 100. Raw value: shows the percentage of I/O operations that are read operations (since reset of the workload timer, attribute E4h). Reported as integer percentage from 0 to 100. Normalized value: always 100. Raw value: measures the elapsed time (number of minutes since starting this workload timer). Normalized value: always 100. Raw value: reports Percent Throttle Status and Count of events Byte 0: Throttle status reported as integer percentage. Bytes 1-4: Throttling event count. Number of times thermal throttle has activated. Preserved over power cycles. Byte 5: Reserved. Normalized value: always 100. October 2014 330566-005US Intel® Solid-State Drive DC P3700 Series 5.5 Temperature Statistics Table 20: Temperature Statistics (Log Identifier C5h) Byte # of Bytes Description 0 1 Current Temperature 24 8 Highest temperature 32 8 Lowest temperature 80 8 Specified Maximum Operating Temperature 96 8 Specified Minimum Operating Temperature 104 8 Estimated offset Note: For 2.5-inch form factor, case temperature is reported. For Add-in Card, NAND temperature is reported. 5.6 Drive Marketing Name Log Table 21: Drive Marketing Name Log (Log Identifier DDh) Byte # of Bytes Log Page Content 0 8 Intel 8 1 Space 9 3 SSD 12 1 Space 13 2 DC 15 1 Space 16 5 P3700 21 1 Space 22 6 Series 28-511 484 Reserved 5.7 SET Feature Identifiers In addition to the SMART attribute structure, features pertaining to the operation and health of the Intel SSD DC P3700 Series can be reported to the host on request through the Get Features command. P3700 Series can change settings using SET Features on the following items as defined in NVMe 1.0 specification. October 2014 330566-005US Arbitration (Feature Identifier 01h) Power Management (Feature Identifier 02h) Temperature Threshold (Feature Identifier 04h) Error Recovery (Feature Identifier 05h) Volatile Write Cache (Feature Identifier 06h) Number of Queues (Feature Identifier 07h) Interrupt Coalescing (Feature Identifier 08h) Interrupt Vector Configuration (Feature Identifier 09h) Write Atomicity (Feature Identifier 0Ah) Asynchronous Event Configuration (Feature Identifier 0Bh) Product Specification 27 Intel® Solid-State Drive DC P3700 Series Intel SSD DC P3700 Series will also support the following vendor unique SET Features. Set/Get Max LBA (Feature Identifier C1h) Get Native Max LBA (Feature Identifier C2h) Power Governor Setting (Feature Identifier C6h) Reset Timed Workload Counters (Feature Identifier D5h) Table 22: Set Max LBA Setting - Command Dword 11 and Command Dword 12 Bit 63:00 Description Maximum User LBA: Write Usage: This field sets the 64-bit maximum LBA addressable by the Drive. Read Usage: This field contains the 64-bit maximum LBA addressable by the Drive. Command Dword 11 contains bits 31:00; Command Dword 12 contains bits 63: 32. Table 23: Status Code - Set Max LBA Command Specific Status Values Value Description C0h Requested MAX LBA exceeds Available capacity C1h Requested MAX LBA smaller than minimum allowable limit. C2h Requested MAX LBA is smaller than allocated Namespace requirements Table 24: C6h - Set/Get Power Governor Setting – Command Dword 11 Bit Description 31:08 Reserved (TBD) 07:00 Power Governor Setting: 00h = 25W(typ), 01h = 20W(typ), 02h =10W(typ) Table 25: Status Codes - Power Governor Setting Command Specific Status Values Value Description C0h Invalid Setting Table 26: D5h – Reset Timed Workload Counters – Command Dword 11 Bit Description 31:01 00 Reserved Timed Workload Reset Settings: Write Usage: 00 = NOP, 1 = Reset E2, E3,E4 counters; Read Usage: Not Supported Note: Get Features will not work for “Reset Timed Workload Counters” and status code is same as Table 25. § Product Specification 28 October 2014 330566-005US Intel® Solid-State Drive DC P3700 Series 6 NVMe Driver Support Table 27 describes the NVMe Driver Support for Intel SSD DC P3700 Series. The support includes releasing and validating NVMe drivers for certain operating systems and validating functionality for open source drive, inbox or native drivers for select operating systems. Table 27: NVMe Driver Support Support Level Operating System Description Intel Provided1 Windows Server 2012 R2, 2012, 2008 R2 x64, Windows 7(32bit/64bit), Windows 8 (32bit/64bit), Windows 8.1 (32bit/64Bit) In-box Driver2 RHEL 6.5, RHEL 7.0, SLES11 SP3,Windows Server 2012 R2, Windows 8.1 NOTES: 1. With Intel provided driver, full product specification is guaranteed, booting is only supported for 64bit OS 2. With open source non-Intel driver, compatibility and functionality is validated § October 2014 330566-005US Product Specification 29 Intel® Solid-State Drive DC P3700 Series 7 Certifications and Declarations Table 28: Device Certifications and Declarations Certification Description CE* Compliant European Economic Area (EEA): Compliance with the essential requirements of EC Council Directives Low Voltage Directive (LVD) 2006/95/EC, EMC Directive 2004/108/EC and Directive 2011/65/EU. UL* Recognized Certified Underwriters Laboratories, Inc. Bi-National Component Recognition; UL 60950-1, 2nd Edition, 2007-03-27 (Information Technology Equipment - Safety - Part 1: General Requirements) CSA C22.2 No. 60950-1-07, 2nd Edition, 2007-03 (Information Technology Equipment - Safety - Part 1: General Requirements) C-Tick* Compliant Compliance with the Australia/New Zealand Standard AS/NZS3548 and Electromagnetic Compatibility (EMC) Framework requirements of the Australian Communication Authority (ACA). BSMI* Compliant Compliance to the Taiwan EMC standard CNS 13438: Information technology equipment Radio disturbance Characteristics - limits and methods of measurement, as amended on June 1, 2006, is harmonized with CISPR 22: 2005.04. KCC* Compliance with paragraph 1 of Article 11 of the Electromagnetic Compatibility Control Regulation and meets the Electromagnetic Compatibility (EMC) Framework requirements of the Radio Research Laboratory (RRL) Ministry of Information and Communication Republic of Korea. VCCI* Voluntary Control Council for Interface to cope with disturbance problems caused by personal computers or facsimile. Microsoft* WHCK Microsoft Windows Hardware Certification Kit RoHS* Compliant Restriction of Hazardous Substance Directive WEEE* Directive on Waste Electrical and Electronic Equipment § Product Specification 30 October 2014 330566-005US Intel® Solid-State Drive DC P3700 Series Appendix A IDENTIFY Data Structure Table 29: Identify Controller Bytes F = Fixed V = Variable X = Both Default Value Interpretation Description 1-0 F 8086h Contains the company vendor identifier that is assigned by the PCI SIG PCI Vendor ID (VID) 3-2 F 8086h Contains the company vendor identifier that is assigned by the PCI SIG for subsystem PCI Subsystem Vendor ID (SSVID) 23-4 V varies Contains the serial number for the NVM subsystem Serial Number (SN) 63-24 V varies Contains the serial number for the NVM subsystem that is assigned by the vendor as an ASCII string Model Number (MN) 71-64 V varies Contains the currently active firmware revision for the NVM subsystem Firmware Revision (FR) 72 F 0h Recommended Arbitration Burst size equals 1 Recommended Arbitration Burst (RAB) 75-73 F 5CD2E4h Contains the Organization Unique Identifier (OUI) for the controller vendor IEEE OUI Identifier (IEEE) 76 X 0h No of multiple PCI Express interfaces connected to the host, bit 0 determines multiple interface Multi-Interface Capabilities (MIC) 77 F 05h Supports MDTS of 128K Maximum Data Transfer Size (MDTS) 255:78 Reserved 257-256 F 07h Supports Security Send/Receive, Format NVM and Firmware Activate/Download Optional Admin Command Support (OACS) 258 F 03h Supports up to 3 concurrently outstanding abort commands Abort Command Limit (ACL) 259 F 03h Supports up to 3 concurrently outstanding asynchronous event requests Asynchronous Event Request Limit (AERL) 260 X 03h Single slot Read/write capable Firmware Updates (FRMW) 261 X 0h SMART/Health Log Support per drive not per namespace Log Page Attributes (LPA) 262 F 3Fh Number of Error Information log entries equals 64 Error Log Page Entries (ELPE) October 2014 330566-005US Product Specification 31 Intel® Solid-State Drive DC P3700 Series Bytes F = Fixed V = Variable X = Both Default Value Interpretation Description 263 F 0h Number of NVM Express power states equal 1 Number of Power States Support (NPSS) 264 F 0h Configuration settings for Admin Vendor Specific command handling Admin Vendor Specific Command Configuration (AVSCC) 511-265 Reserved 512 F 66h Required and max submission queue entry size is 64 Byte Submission Queue Entry Size (SQES) 513 F 44h Required and max submission queue entry size is 16 Byte Completion Queue Entry Size (CQES) 515-514 Reserved 519-516 F 01h Supports single namespace Number of Namespaces (NN) 521-520 F 06h Supports Dataset Management and Write Uncorrectable optional NVMe commands. Optional NVMe Command Support (ONCS) 523-522 F 0h Fused commands not supported Fused Operation Support (FUSES) 524 F 07h Supports Crypto Erase and format of entire drive, not per namespace Format NVM Attributes (FNA): 525 F 0h Volatile write cache is not present Volatile Write Cache (VWC) 527-526 F 0h Atomic write size for controller during normal equals to 512B Atomic Write Unit Normal (AWUN) 529-528 F 0h Indicates the atomic write size for the controller during a power fail condition equals 512B Atomic Write Unit Power Fail (AWUPF) 530 X 0h Not Supported NVM Vendor Specific Command Configuration (NVSCC) 703-531 Reserved 2047-704 Reserved 2079-2048 V Indicates the characteristics of power state 0 Power State 0 Descriptor (PSD0) 2111-2080 V Indicates the characteristics of power state 1 Power State 1 Descriptor (PSD1) 2143-2112 V Indicates the characteristics of power state 2 Power State 2 Descriptor (PSD2) 2175-2144 V Indicates the characteristics of power state 3 Power State 3 Descriptor (PSD3) 2207-2176 V Indicates the characteristics of power state 4 Power State 4 Descriptor (PSD4) 2239-2208 V Indicates the characteristics of power state 5 Power State 5 Descriptor (PSD5) 2271-2240 V Indicates the characteristics of power state 6 Power State 6 Descriptor (PSD6) Product Specification 32 October 2014 330566-005US Intel® Solid-State Drive DC P3700 Series Bytes F = Fixed V = Variable X = Both 2303-2272 V Indicates the characteristics of power state 7 Power State 7 Descriptor (PSD7) 2335-2304 V Indicates the characteristics of power state 8 Power State 8 Descriptor (PSD8) 2367-2336 V Indicates the characteristics of power state 9 Power State 9 Descriptor (PSD9) 2399-2368 V Indicates the characteristics of power state 10 Power State 10 Descriptor (PSD10) 2431-2400 V Indicates the characteristics of power state 11 Power State 11 Descriptor (PSD11) 2463-2432 V Indicates the characteristics of power state 12 Power State 12 Descriptor (PSD12) 2495-2464 V Indicates the characteristics of power state 13 Power State 13 Descriptor (PSD13) 2527-2496 V Indicates the characteristics of power state 14 Power State 14 Descriptor (PSD14) 2559-2528 V Indicates the characteristics of power state 15 Power State 15 Descriptor (PSD15) 2591-2560 V Indicates the characteristics of power state 16 Power State 16 Descriptor (PSD16) 2623-2592 V Indicates the characteristics of power state 17 Power State 17 Descriptor (PSD17) 2655-2624 V Indicates the characteristics of power state 18 Power State 18 Descriptor (PSD18) 2687-2656 V Indicates the characteristics of power state 19 Power State 19 Descriptor (PSD19) 2719-2688 V Indicates the characteristics of power state 20 Power State 20 Descriptor (PSD20) 2751-2720 V Indicates the characteristics of power state 21 Power State 21 Descriptor (PSD21) 2783-2752 V Indicates the characteristics of power state 22 Power State 22 Descriptor (PSD22) 2815-2784 V Indicates the characteristics of power state 23 Power State 23 Descriptor (PSD23) 2847-2816 V Indicates the characteristics of power state 24 Power State 24 Descriptor (PSD24) 2879-2848 V Indicates the characteristics of power state 25 Power State 25 Descriptor (PSD25) 2911-2880 V Indicates the characteristics of power state 26 Power State 26 Descriptor (PSD26) 2943-2912 V Indicates the characteristics of power state 27 Power State 27 Descriptor (PSD27) 2975-2944 V Indicates the characteristics of Power State 28 Descriptor (PSD28) October 2014 330566-005US Default Value Interpretation Description Product Specification 33 Intel® Solid-State Drive DC P3700 Series Bytes F = Fixed V = Variable X = Both Default Value Interpretation Description power state 28 3007-2976 V Indicates the characteristics of power state 29 Power State 29 Descriptor (PSD29) 3039-3008 V Indicates the characteristics of power state 30 Power State 30 Descriptor (PSD30) 3071-3040 V Indicates the characteristics of power state 31 Power State 31 Descriptor (PSD31) 3075 F 05h Data striped at 128 KB, value shown is reported as 2^ (CAP.MPSMIN) Internal stripe size 3095-3076 V Varies Shows healthy status or error code Health indicator 3096 V Varies Reads current negotiated PCIe link speed, as reported by PXLS register (PXCAP + 12h), bits[3:0] Current PCIe Link Speed field (CLS) 3097 V Varies Reads current negotiated PCIe Link Width as reported by PXLS register (PXCAP + 12h), bits[9:4] Negotiated Link Width (NLW) 4095-3098 V NA Range of bytes is allocated for vendor specific usage Vendor Specific (VS) NOTES: F = Fixed. The content of the word is fixed and does not change. For removable media devices, these values may change when media is removed or changed. V = Variable. The state of at least one bit in a word is variable and may change depending on the state of the device or the commands executed by the device. X = F or V. The content of the word may be fixed or variable. Product Specification 34 October 2014 330566-005US Intel® Solid-State Drive DC P3700 Series Table 30: Power State Descriptor Bytes F = Fixed V = Variable X = Both Default Value Interpretation 255-125 124-120 Reserved F 0h Indicates the relative write latency associated with this power state 119-117 116-112 Relative Write Latency (RWL) Reserved F 0h Indicates the relative write throughput associated with this power state 111-109 108-104 Description Relative Write Throughput (RWT) Reserved F 0h Indicates the relative read latency associated with this power state 103-101 Relative Read Latency (RRL) Reserved 100-96 F 0h Indicates the relative read throughput associated with this power state. Relative Read Throughput (RRT) 95-64 F 0h Indicates the maximum exit latency in microseconds associated with exiting this power state. Exit Latency (EXLAT) 63-32 F 0h Indicates the maximum entry latency in microseconds associated with entering this power state Entry Latency (ENLAT) 31-16 15-00 Reserved F 09C4h Indicates the maximum power consumed by the NVM subsystem in this power state. The power in Watts is equal to the value in this field multiplied by 0.01 Maximum Power (MP) NOTES: F = Fixed. The content of the word is fixed and does not change. For removable media devices, these values may change when media is removed or changed. V = Variable. The state of at least one bit in a word is variable and may change depending on the state of the device or the commands executed by the device. X = F or V. The content of the word may be fixed or variable. October 2014 330566-005US Product Specification 35 Intel® Solid-State Drive DC P3700 Series Table 31: Identify Namespace Bytes F = Fixed V = Variable X = Both 7-0 V varies Indicates the total size of the namespace in logical blocks. Namespace Size (NSZE) 15-8 V varies Indicates the maximum number of logical blocks that may be allocated in the namespace at any point in time Namespace Capacity (NCAP) 23-16 V varies Indicates the current number of logical blocks allocated in the namespace Namespace Utilization (NUSE) 24 F 00h Indicates thin provisioning is not supported Namespace Features (NSFEAT) 25 F 06h Defines the number of supported LBA size and metadata size combinations supported by the namespace Number of LBA Formats (NLBAF) 26 V 00h Indicates metadata transferred with the extended data LBA or in separate buffer Formatted LBA Size (FLBAS) Metadata Capabilities (MC) Default Value Interpretation Description 27 F 03h Indicates support for metadata transferred with the extended data LBA and in separate buffer – both are supported 28 V 11h Indicates PI supports Type 1,2,3 with PI transferred as the first 8 bytes End-to-end Data Protection Capabilities (DPC) 29 X 00h Indicates type settings for the namespace End-to-end Data Protection Type Settings (DPS) 127-30 Reserved 131-128 V MS:0, LBADS:9, RP:2 Indicates the LBA format 0 that is supported by the controller LBA Format 0 Support (LBAF0) 135-132 V MS:8, LBADS:9, RP:2 Indicates the LBA format 1 that is supported by the controller LBA Format 1 Support (LBAF1) 139-136 V MS:16, LBADS:9, RP:2 Indicates the LBA format 2 that is supported by the controller LBA Format 2 Support (LBAF2) 143-140 V MS:0, LBADS:12, RP:0 Indicates the LBA format 3 that is supported by the controller LBA Format 3 Support (LBAF3) 147-144 V MS:8, LBADS:12, RP:0 Indicates the LBA format 4 that is supported by the controller LBA Format 4 Support (LBAF4) 151-148 V MS:64, LBADS:12, RP:0 Product Specification 36 Indicates the LBA format 5 that is supported by the controller LBA Format 5 Support (LBAF5) October 2014 330566-005US Intel® Solid-State Drive DC P3700 Series Bytes F = Fixed V = Variable X = Both 155-152 V Default Value Interpretation Description MS:128, LBADS:12, RP:0 Indicates the LBA format 6 that is supported by the controller 159-156 Not supported Indicates the LBA format 7 that is supported by the controller LBA Format 7 Support (LBAF7) 163-160 Not supported Indicates the LBA format 8 that is supported by the controller LBA Format 8 Support (LBAF8) 167-164 Not supported Indicates the LBA format 9 that is supported by the controller LBA Format 9 Support (LBAF9) 171-168 Not supported Indicates the LBA format 10 that is supported by the controller LBA Format 10 Support (LBAF10) 175-172 Not supported Indicates the LBA format 11 that is supported by the controller LBA Format 11 Support (LBAF11) 179-176 Not supported Indicates the LBA format 12 that is supported by the controller LBA Format 12 Support (LBAF12) 183-180 Not supported Indicates the LBA format 13 that is supported by the controller LBA Format 13 Support (LBAF13) 187-184 Not supported Indicates the LBA format 14 that is supported by the controller LBA Format 14 Support (LBAF14) 191-188 Not supported Indicates the LBA format 15 that is supported by the controller LBA Format 15 Support (LBAF15) 383-192 Not supported 4095-384 Not supported LBA Format 6 Support (LBAF6) Reserved Range of bytes is allocated for vendor specific usage Vendor Specific (VS) NOTES: F = Fixed. The content of the word is fixed and does not change. For removable media devices, these values may change when media is removed or changed. V = Variable. The state of at least one bit in a word is variable and may change depending on the state of the device or the commands executed by the device. X = F or V. The content of the word may be fixed or variable October 2014 330566-005US Product Specification 37 Intel® Solid-State Drive DC P3700 Series Table 32: LBA Format Data Structure Bytes F = Fixed V = Variable X = Both Default Value Interpretation Description Reserved 31-26 25-24 V Varies (2,0) Relative Performance ranging from “best” to “degraded” Relative Performance (RP) 23-16 V Varies (9 and 12) Indicates the LBA data size supported. The value is reported in terms of a power of two (2^n) LBA Data Size (LBADS) 15-00 V Varies (0, 8, 16,64, 128) Indicates the number of metadata bytes provided per LBA based on the LBA Data Size indicated. Metadata Size (MS) NOTES: F = Fixed. The content of the word is fixed and does not change. For removable media devices, these values may change when media is removed or changed. V = Variable. The state of at least one bit in a word is variable and may change depending on the state of the device or the commands executed by the device. X = F or V. The content of the word may be fixed or variable. § Product Specification 38 October 2014 330566-005US Intel® Solid-State Drive DC P3700 Series Appendix B Vital Data Structure Table 33: Vital Product Data Structure (VPD) Address # Bytes 0 Function 3 3 Class Code 2 ID Programming Value Byte Description 02h 0 Device type and Programming Interface 08h 1 01h 2 86h 3 80h 4 Varies 5-24 Serial Number Varies 25-64 Model Number 03h 65 Maximum Link Speed 04h 66 Maximum Link Width 03h 67 Maximum Link Speed 04h 68 Maximum Link Width 12V Power rail initial power requirement (W) 5 20 25 40 65 1 66 1 67 1 68 1 69 1 Initial Power Requirements 0Ah 69 70 2 Reserved 00h 70-71 72 1 Maximum Power Requirements 19h 72 73 2 Reserved 00h 73-74 75 2 Capability List Pointer 50h 75 PCIe Port0 Capabilities PCIe Port1 Capabilities PCI-SIG Vendor ID 12V Power rail maximum power requirement (W) 16b address pointer to start of capability list Table 34: Capability List Pointer (Out of Band Temperature Sensor) Addr (Hex) 00 01 02 03 04 05 06 07 08 09 A B 50 A2 00 00 00 00 36 00 00 varies varies varies varies Description Capability ID (temp) Next Capability (none) Sensor Type SMBUS address Reserved Warning Threshold Over Temperature § October 2014 330566-005US Product Specification 39 Intel® Solid-State Drive DC P3700 Series Appendix C Appendix C Out of Band Temperature Sensor Read Out Register 0x05 on address 0x1B contains the temperature information for the latest readout. Measured temperature is captured by bit 12 to bit 0. Data format is two’s complement. Bit12 represents sign value, bit11 presents 128 ° C and bit0 represents 0.0625° C. Following table gives an example of the read out. Table 35: Register 0x05 read out format Binary Hex Temperature 1 1100 1001 0000 1C90 -55° C 1 1100 1110 0000 1CE0 -50° C 1 1110 0111 0000 1E70 -25° C 1 1111 1111 1111 1FFFF -0.0625° C 0 0000 0000 0000 000 0° C 0 0000 0000 0001 001 0.0625° C 0 0001 1001 0000 190 25° C 0 0011 0010 0000 320 50° C 0 0111 1101 0000 7D0 55° C § Product Specification 40 October 2014 330566-005US Intel® Solid-State Drive DC P3700 Series Appendix D PCIe ID Table 36: PCIe ID ID name Description Add-in Card 2.5” FF PCIe Register Location Identify Controller Location Vital Product Data Location Vendor ID (VID) Vendor ID assigned by PCI-SIG 0x8086 0x8086 PCI Header Offset 00h (bits 15:00) Bytes 01:00h Address 3, (size 2B) Device ID (DID) Device ID assigned by vendor 0x0953 0x0953 PCI Header Offset 00h (bits 31:16) NA NA Subsystem Vendor ID Indicates Subsystem vendor ID 0x8086 0x8086 PCI Header Offset 2Ch (bits 15:00) Bytes 03:02h NA Subsystem ID Sub-system identifier 0x3702 0x3703 PCI Header Offset 2Ch (bits 31:16) NA NA § October 2014 330566-005US Product Specification 41 Intel® Solid-State Drive DC P3700 Series Appendix E SCSI Command Translation Following SCSI commands are supported: Read 6,10,12,16 Inquiry Mode Sense 6,10 Mode Select 6.10 Log Sense Read Capacity 10,16 Report LUNs Request Sense Start Stop Unit Test Unit Ready Write Buffer Unmap Note: Refer to NVM Express: SCSI translation reference doc under nvmexpress.org § Product Specification 42 October 2014 330566-005US Intel® Solid-State Drive DC P3700 Series Appendix F Add-in Card LED Decoder Table 37: LED Functionality LED Description Blink Behavior LED 1( Amber) Shows IO activity Blinks at the rate of 250msec high, 250msec low with IO activity LED 2 (Red) Drive fail indicator Solid red if drive is in disabled logical mode LED 3 (Yellow) Drive pre-fail indicator Solid yellow if any of the critical warnings in log page 0x02 is triggered LED 4 (Green) Drive health indicator Solid green when drive is healthy Figure A-1: LED Location Note: 2.5-inch Form factor does not contain LEDs § October 2014 330566-005US Product Specification 43