CUI VSUP-1K2-12

rev.
page
page
1 of 4
date
date
10/2007
DESCRIPTION: switching power supply
PART NUMBER: VSUP-1K2 series
features
·current sharing capability
·0.98 typical power factor
·programmable output voltage
·universal AC input
·short circuit, overload, over voltage,
over temperature protected
·forced air cooling by built-in DC fan
·power failure signal
·built-in remote sense
·built-in remote inhibit
·2 year warranty
model
VSUP-1K2-09
VSUP-1K2-12
VSUP-1K2-15
VSUP-1K2-18
VSUP-1K2-24
VSUP-1K2-30
VSUP-1K2-36
VSUP-1K2-48
VSUP-1K2-60
output 1
9 V
12 V
15 V
18 V
24 V
30 V
36 V
48 V
60 V
output current
minimum
maximum
0A
133 A
0A
100 A
0A
80 A
0A
66.6 A
0A
50 A
0A
40 A
0A
33.3 A
0A
24 A
0A
20 A
max. power
1200 W
1200 W
1200 W
1200 W
1200 W
1200 W
1200 W
1200 W
1200 W
ripple & noise 2
regulation
<1%
<1%
<1%
<1%
<1%
<1%
<1%
<1%
<1%
(Vpp)
1%
1%
1%
1%
1%
1%
1%
1%
1%
efficiency
83%
84%
85%
85%
88%
88%
88%
89%
90%
notes:
1 output voltage is measured at output power connector.
2 ripple and noise is measured from 10 KHz to 20 MHz at output terminals with 0.1 μF ceramic capacitor and
a 22 μF electrolytic capacitor in parallel.
INPUT
parameter
input frequency
input voltage
irush current
conditions/description
9V
12, 15, 18, 24, 30, 36, 48, 60V
peak measured at 230 VAC at full load, cold start
min
47
180
110
nom
max
63
264
264
120
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382
units
Hz
VAC
VAC
A
rev.
PART NUMBER: VSUP-1K2 series
page
2 of 4
date
10/2007
DESCRIPTION: switching power supply
OUTPUT
parameter
hold-up time
programming
voltage adjustability
conditions/description
full load at 230 VAC
output voltage programmable through external
0~5V control voltage on VCI.
typical adjustment by potentiometer
20%-100% adjustment by 1-5Vdc external control
min
20
max
12
100
units
mS
%
-5
+5
%
temp. coefficient
nom
±0.04
%/ºC
PROTECTION CIRCUIT
parameter
overload
overvoltage
conditions/description
min
nom
max
current limiting 3 times (1.5”, 3.0”, 5.0”), then intelligent auto recovery before shutdown
variable “OVP” follows adjustable DC output
110
135
units
%
GENERAL AND SAFETY
parameter
operating temp.
operating humid.
storage temp.
storage humid.
vibration
EMC
safety regulation
leakage current
cooling
conditions/description
min
0
20%
-20
10
period of 60 min. for each axis
10
EN55022, EN610000-4-2,3,4,5,6,8,11, EN61000-3-2-3 ENV50204
approved to UL/cUL 1950, TUV EN60950
at 240 VAC
Power rating and temperature controlled fan
nom
conditions/description
nom
3.8
max
50
90%
85
95%
200
units
ºC
RH
ºC
RH
Hz
<7.0
mA
max
units
Kg
mm
MECHANICAL
parameter
weight
enclosure
min
279(L) x 203(W) x 63.5(H)
LOGIC CONNECTOR
parameter
pin assignments:
connector 1
conditions/description
suggested mating connector: JST XHP-6 or equivalent
1. VCI - command input voltage for output programming
2. REF - 5V reference output. can be used to derive VCI.
3. PG - power good signal
4. GND - return / output ground
5. INH - remote on-off / remote Inhibit
6. PAR - current sharing / parallel function
REMOTE SENSE
parameter
pin assignments:
connector 2
conditions/description
suggested mating connector: JST XHP-2 or equivalent
1. VS(-) - remote sense (-)
2. VS(+) - remote sense (+)
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382
rev.
PART NUMBER: VSUP-1K2 series
page
3 of 4
date
10/2007
DESCRIPTION: switching power supply
LOGIC CONNECTIONS
1KΩ
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382
rev.
PART NUMBER: VSUP-1K2 series
page
4 of 4
date
10/2007
DESCRIPTION: switching power supply
MECHANICAL DRAWING
DERATING CURVES
load derating curve
output power vs. input voltage derating curve
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382