ML100SER Datasheet - Micropower Direct

ML100SER Series
Low Cost, Regulated
1W SMT, Single Output
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
Input
• 1W Output Power
• Miniature SMT Case
• Tight Regulation
Parameter
• -40ºC to +85ºC Operation
• Short Circuit Protection
• Low 0.24” Profile
• >3.5 MHour MTBF
• Industry Standard Pin-Out
• LOW COST!
Conditions
Min.
Typ.
Max.
4.75
5.0
5.25
12 VDC Input
11.4
12.0
12.6
15 VDC Input
14.25
15.0
15.75
24 VDC Input
22.80
24.0
25.20
Typ.
Max.
5 VDC Input
Input Voltage Range
Input Filter
Units
VDC
Capacitor
Output
Parameter
Conditions
Min.
Output Voltage Accuracy
Line Regulation
For Vin Change of 5%
Load Regulation
For Iout = 10% to 100%
Output Ripple (20 MHz)
See Note 1
10
Output Noise (20 MHz)
See Note 1
50
Temperature Coefficient
Output Short Circuit
Units
±3.0
%
±0.3
%
±1.0
%
20
mV P - P
150
mV P - P
±0.03
%/ºC
Max.
Units
Continuous (Autorecovery)
General
Parameter
Conditions
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Min.
60 Seconds
1,000
500 VDC
1,000
100 kHz, 1V
Switching Frequency
Typ.
VDC
M⍀
70
pF
100
kHz
Environmental
Parameter
Conditions
Operating Temperature Range
Ambient
Storage Temperature Range
Min.
Typ.
Max.
-40
+25
+85
ºC
+125
ºC
95
%
-55
Cooling
Units
Free Air Convection
Humidity
RH, Non-condensing
Physical
Case Size
See Mechanical Drawing (Page 2)
Case Material
Non-Conductive Black Plastic (UL94-V0)
Weight
0.09 Oz (2.9g)
MicroPower Direct
Reliability Specifications
292 Page Street
Suite D
Stoughton, MA 02072
USA
MTBF
Parameter
Conditions
Typ.
Max.
3.5
Units
MHours
Absolute Maximum Ratings
Parameter
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Min.
MIL HDBK 217F, 25ºC, Gnd Benign
Conditions
Input Voltage Surge (1 Sec)
Min.
Typ.
-0.7
12 VDC Input
-0.7
15.0
15 VDC Input
-0.7
18.0
24 VDC Input
-0.7
28.0
Peak Reflow Temperature
Lead Temperature
Max.
5 VDC Input
1.5 mm From Case For 10 Sec
VDC
245
ºC
300
ºC
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
Units
7.0
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
Voltage (VDC)
ML105S-05ER
ML105S-09ER
ML105S-12ER
ML105S-15ER
ML112S-05ER
ML112S-15ER
ML115S-05ER
ML115S-09ER
ML115S-12ER
ML115S-15ER
ML124S-05ER
ML124S-09ER
ML124S-05ER
ML112S-15ER
Nominal
5
5
5
5
12
12
15
15
15
15
24
24
24
24
Output
Current (mA)
Range
4.75 - 5.25
4.75 - 5.25
4.75 - 5.25
4.75 - 5.25
11.40 - 12.60
11.40 - 12.60
14.25 - 15.75
14.25 - 15.75
14.25 - 15.75
14.25 - 15.75
22.80 - 25.20
22.80 - 25.20
22.80 - 25.20
22.80 - 25.20
Full-Load
217
285
281
279
91
115
72
95
93
93
45
59
58
58
Voltage
(VDC)
No-Load
20
20
20
20
15
15
10
10
10
10
7
7
7
7
5.0
9.0
12.0
15.0
5.0
15.0
5.0
9.0
12.0
15.0
5.0
9.0
12.0
15.0
Notes:
1. When measuring output ripple, it is recommended that an external 0.33 µF ceramic capacitor be
placed from the +Vout pin to the -Vout pin.
2. Operating at no load will not damage the converter, however, it may not meet all specifications.
3. These converters are specified for operation without external components. However, in some
applications the addition of input/output capacitors will enhance stability and reduce output ripple.
Recommended capacitor values are:
Vin
5 VDC
12 VDC
15 VDC
24 VDC
Input
Capacitor
4.7 µF
2.2 µF
1.0 µF
1.0 µF
Vout
5 VDC
9 VDC
12 VDC
15 VDC
Current
(mA, Max)
Current
(mA, Min)
150.0
111.0
83.0
67.0
150.0
67.0
150.0
111.0
83.0
67.0
150.0
111.0
83.0
67.0
Efficiency
(%, Typ)
Fuse Rating
Slow-Blow
(mA)
69
70
71
72
69
72
69
70
71
72
69
70
71
72
500
500
500
500
250
250
200
200
200
200
150
150
150
150
15.0
12.0
9.0
7.0
15.0
7.0
15.0
12.0
9.0
7.0
15.0
12.0
9.0
7.0
Derating Curve
Output
Capacitor
4.7 µF
2.2 µF
2.2 µF
1.0 µF
For applications requiring very low output noise levels, a simple LC filter should be effective.
5. The recommended time above liquidous (TL) is <60 seconds at 217 °C. For
more information, please contact the factory.
6. It is recommended that a fuse be used on the input of a power supply for protection. See the
Model Selection table above for the correct rating.
Mechanical Dimensions
Pin Connections
Pin
1
2
3
5
6
7
Function
Pin Function
-Vin
8
NC
+Vin
9
NC
NC
10
NC
NC
12
NC
-Vout
13
NC
+Vout
14
NC
NC = No Connection
Board Layout
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
• Pin 1 is marked by a “dot” or indentation on the unit
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]