Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
Input
• 1W Output Power
• Ultra-Miniature SMT Case
• 3,000 VDC Isolation
• EN 60950 Approved
• Short Circuit Protected
• Dual Output
• -40°C to +105°C Operation
• >3.5 MHour MTBF
• LOW COST!
Parameter
Input Voltage Range
Input Filter
Conditions
Min.
3.3 VDC Input 2.97
5.0 VDC Input
4.5
12 VDC Input 10.8
24 VDC Input 21.6
Capacitor
Typ.
3.3
5.0
12.0
24.0
Max.
3.63
5.5
13.2
26.4
Units
Conditions
Typ.
±3.0
Max.
100
±1.2
Units
%
µF
%
±0.03
mV P - P
%/ºC
VDC
Output
Parameter
Output Voltage Accuracy
Capacitive Load
Line Regulation
Load Regulation, See Note 1
Ripple & Noise (20 MHz)
Temperature Coefficient
Output Short Circuit
Min.
For VIN Change of 1%
See Model Selection Guide
See Note 2
60
Continuous (Autorecovery)
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
EMI Characteristics
Parameter
EMI Compliance, See Note 4
EMC Compliance
Conditions
60 Seconds
500 VDC
100 kHz, 0.1V
Conditions
Conducted (CE)
Radiated (RE)
Electrostatic Discharge (ESD)
Min.
3,000
1,000
Typ.
Max.
20
100
300
Units
VDC
M⍀
pF
kHz
Min.
Typ.
Max.
Units
CISPR22/EN 55022 Level B
CISPR22/EN 55022 Level B
EN 61000-4-2 Level B Contact ±6 kV
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
MicroPower Direct
Reliability Specifications
292 Page Street
Suite D
Stoughton, MA 02072
USA
Parameter
MTBF
Safety Standards
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Conditions
Min.
Typ.
-40
+25
-55
Free Air Convection
RH, Non-condensing
Ambient
Max.
+105
+125
Units
ºC
ºC
95
%
See Mechanical Drawing (Page 2)
Non-Conductive Black Plastic (UL94-V0)
0.06 Oz (1.80g)
Conditions
Min.
MIL HDBK 217F, 25ºC, Gnd Benign
3.5
EN 60950
Typ.
Max.
Units
MHours
Typ.
Max.
5.0
9.0
18.0
30.0
245
300
Units
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Peak Reflow Temperature
Lead Temperature
Conditions
3.3 VDC Input
5 VDC Input
12 VDC Input
24 VDC Input
See Note 5
1.5 mm From Case For 10 Sec
Min.
-0.7
-0.7
-0.7
-0.7
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
VDC
ºC
ºC
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
ML103D-05EI
ML103D-12EI
ML105D-05EI
ML105D-09EI
ML105D-12EI
ML105D-15EI
ML105D-24EI
ML112D-05EI
ML112D-09EI
ML112D-12EI
ML112D-15EI
ML112D-24EI
ML124D-05EI
ML124D-09EI
ML124D-12EI
ML124D-15EI
ML124D-24EI
Output
Voltage (VDC)
Current (mA)
Nominal
Range
Full-Load No-Load
3.3
2.97 - 3.63
388
25
3.3
2.97 - 3.63
388
25
5
4.50 - 5.50
250
20
5
4.50 - 5.50
250
20
5
4.50 - 5.50
247
20
5
4.50 - 5.50
247
20
5
4.50 - 5.50
247
20
12
10.8 - 13.2
104
15
12
10.8 - 13.2
104
15
12
10.8 - 13.2
103
15
12
10.8 - 13.2
103
15
12
10.8 - 13.2
103
15
24
21.6 - 26.4
51
7
24
21.6 - 26.4
51
7
24
21.6 - 26.4
51
7
24
21.6 - 26.4
51
7
24
21.6 - 26.4
51
7
Voltage
Current
Current
(VDC)
(mA, Max)
(mA, Min)
±5.0
±12.0
±5.0
±9.0
±12.0
±15.0
±24.0
±5.0
±9.0
±12.0
±15.0
±24.0
±5.0
±9.0
±12.0
±15.0
±24.0
±100.0
±42.0
±100.0
±56.0
±42.0
±33.0
±21.0
±100.0
±56.0
±42.0
±33.0
±21.0
±100.0
±56.0
±42.0
±33.0
±21.0
±10.0
±5.0
±10.0
±6.0
±5.0
±3.0
±2.0
±10.0
±6.0
±5.0
±3.0
±2.0
±10.0
±6.0
±5.0
±3.0
±2.0
Notes:
1. Output load regulation is specified for a load change of 10% to 100%.
2. When measuring output ripple, it is recommended that a 1 µF capacitor and a 10 µF capacitor be placed
in parallel from the +Vout pin to the -Vout pin.
3. It is recommended that the minimu output load should be at least 10%. Operation below this level will not
damage the unit, but it may not meet all specifications..
4. These converters are specified for operation without external components. However, in some applications
the addition of input/output capacitors will enhance stability and reduce output ripple. The simple connection
shown below will typically meet EN 55022 Class B.
VIN
3.3 VDC
5 VDC
12 VDC
24 VDC
C1
4.7 µF/50V
4.7 µF/50V
4.7 µF/50V
4.7 µF/50V
L1
6.8 µH
6.8 µH
6.8 µH
6.8 µH
VOUT
5 VDC
9 VDC
12 VDC
15 VDC
24 VDC
C2
4.7 µF
2.2 µF
1.0 µF
1.0 µF
0.47 µF
Load
Rating
ciency Fuse
Regulation Effi
Slow-Blow
(%, Typ)
(% Typ)
(mA)
12.0
7.0
12.0
8.0
7.0
6.0
5.0
12.0
8.0
7.0
6.0
5.0
12.0
8.0
7.0
6.0
5.0
750
750
500
500
500
500
500
250
250
250
250
250
100
100
100
100
100
Derating Curve
C3
4.7 µF
2.2 µF
1.0 µF
1.0 µF
0.47 µF
5. The recommended time above liquidous (TL) is <60 seconds at 217 °C. For
more information, please contact the factory.
6. It is recommended that a fuse be used on the input of a power supply for
protection. See the Model Selection table above for the correct rating.
78
78
80
80
81
81
81
80
80
81
81
81
82
82
82
82
82
Pin Connections
Pin
1
2
Mechanical Dimensions
Description
-VIN
+VIN
Pin
4
5
8
Description
-VOUT
+VOUT
NC
NC = No Connection
Board Layout
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]