B1000ERW Datasheet

B1000ERW Series
Low Cost 1 x 2 Inch 10W
Wide Input Range
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• 10W Output Power
• 2:1 Input Voltage Range
Input
Parameter
Input Voltage Range
• 1,500 VDC Isolation
• Efficiency to 86%
• Compact 1 x 2 Inch Case
• Single & Dual Outputs
• Industry Standard Pin-Out
• Low, Low Cost!!
Input Filter
Short Circuit Input Power
Conditions
Min.
12 VDC Input
9.0
24 VDC Input 18.0
48 VDC Input 36.0
LC Filter
Typ.
12.0
24.0
48.0
Max.
18.0
36.0
75.0
1,500
Units
VDC
mW
Output
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Positive Load Regulation, See Note 1
Ripple
Noise
Transient Recovery Time, See Note 3
Transient Response Deviation
Temperature Coefficient
Output Short Circuit
Conditions
Min.
Typ.
Dual Output , Balanced Loads
Vin = Min to Max
Iout = 10% to 100%
±0.1
0.2
30
See Note 2
100
200
25% Load Step Change
±2.0
±0.02
Continuous (Autorecovery)
Max.
±3.0
±5.0
±0.2
0.5
50
300
Units
%
%
%
%
mV P - P
mV P - P
µSec
%
%/°C
Max.
Units
VDC
M
pF
kHz
Max.
+85
+125
Units
°C
°C
95
%
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Conditions
60 Seconds
500 VDC
100 kHz, 1V
Min.
1,500
1,000
Typ.
130
300
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Conditions
Min.
Typ.
-40
+25
-55
Free Air Convection
RH, Non-condensing
Ambient
2.0 x 1.0 x 0.44 Inches (50.8 x 25.4 x 11.2 mm)
Aluminum Alloy with Non-Conductive Base (UL94-V0) (UL94-V0)
0.828 Oz (23.5g)
Reliability Specifications
Parameter
MTBF
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min.
1.0
Typ.
Max.
Units
MHours
Conditions
12 VDC Input
24 VDC Input
48 VDC Input
1.5 mm From Case for 10 Sec
All Models
Min.
-0.7
-0.7
-0.7
Typ.
Max.
20.0
40.0
80.0
300
5,000
Units
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Internal Power Dissipation
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
VDC
°C
mW
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
B1001ERW
B1002ERW
B1003ERW
B1004ERW
B1005ERW
B1006ERW
B1007ERW
B1011ERW
B1012ERW
B1013ERW
B1014ERW
B1015ERW
B1016ERW
B1017ERW
B1021ERW
B1022ERW
B1023ERW
B1024ERW
B1025ERW
B1026ERW
B1027ERW
Voltage (VDC)
Nominal
Range
12
9.0 - 18.0
12
9.0 - 18.0
12
9.0 - 18.0
12
9.0 - 18.0
12
9.0 - 18.0
12
9.0 - 18.0
12
9.0 - 18.0
24
18.0 - 36.0
24
18.0 - 36.0
24
18.0 - 36.0
24
18.0 - 36.0
24
18.0 - 36.0
24
18.0 - 36.0
24
18.0 - 36.0
48
36.0 - 75.0
48
36.0 - 75.0
48
36.0 - 75.0
48
36.0 - 75.0
48
36.0 - 75.0
48
36.0 - 75.0
48
36.0 - 75.0
Current (mA)
Full-Load No-Load
1,042
25
1,016
25
1,016
25
1,016
25
1,004
25
992
25
992
25
502
8
490
8
496
8
502
8
490
8
496
8
490
8
251
5
242
5
242
5
251
5
242
5
242
5
242
5
Voltage
Output
Current
Current
(VDC)
(mA, Max)
(mA, Min)
5
12
15
±5
±12
±15
±24
5
12
15
±5
±12
±15
±24
5
12
15
±5
±12
±15
±24
2,000
832
660
±1,000
±416
±333
±210
2,000
832
660
±1,000
±416
±333
±210
2,000
830
670
±1,000
±416
±333
±210
200
83
66
±100
±41
±33
±21
200
83
66
±100
±41
±33
±21
200
83
66
±100
±41
±33
±21
Notes:
5 VDC
12 VDC
15 VDC
±5 VDC
±12 VDC
±15 VDC
±24 VDC
Input
Capacitor
100 µF
100 µF
100 µF
100 µF
100 µF
100 µF
100 µF
(%, Typ)
Capacitive Fuse Rating
Slow-Blow
Load
80
82
82
82
83
84
84
83
85
84
83
85
84
85
83
86
86
83
86
86
86
(µF Max)
(mA)
4,700
690
470
±680
±330
±110
±100
4,700
690
470
±680
±330
±110
±100
4,700
690
470
±680
±330
±110
±100
3,000
3,000
3,000
3,000
3,000
3,000
3,000
1,500
1,500
1,500
1,500
1,500
1,500
1,500
750
750
750
750
750
750
750
Derating Curve
1. For dual output models with unbalanced loads, the output load regulation is specified
at ±5% typ.
2. Ripple & noise is specified for a bandwidth of 20 MHz. When operating these units,
the addition of input/output capacitors will enhance stability and reduce output
ripple. Recommended capacitor values are:
VOUT
Efficiency
Output
Capacitor
220 µF
100 µF
100 µF
±100 µF
±47 µF
±47 µF
±22 µF
3. Transient recovery is measured to within a 1% error band for a load step change of
75% to 100%.
4. These units should not be operated with a load under 10% of full load. Operation at
no-load may cause damage to the unit.
5. Dual output units may be connected to provide a 10V, 24V, 30 VDC or 48 VDC output.
To do this, connect the load across the positive (+Vout) and negative (-Vout) outputs
and float the output common.
7. It is recommended that a fuse be used on the input of a power supply for protection.
See the Model Selection table above for the correct rating.
Mechanical Dimensions
Pin Connections
Pin
1
2
3
4
5
Single
+Vin
-Vin
+Vout
No Pin
-Vout
Dual
+Vin
-Vin
+Vout
Common
-Vout
Mechanical Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]