ME200SE Datasheet - Micropower Direct

ME200SE Series
Low Cost, 2W
Ultra-Miniature SIP
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• 2W Output Power
• Ultra-Miniature SIP Case
Input
Parameter
Conditions
Input Voltage Range
• Short Circuit Protected
Input Filter
• 1,500 VDC Isolation
Output
• >3.5 MHour MTBF
Parameter
• -40°C to +85°C Operation
Output Voltage Accuracy
• LOW COST
Capacitive Load
Min.
Typ.
Max.
5 VDC Input
4.50
5.0
5.50
Units
24 VDC Input
21.60
24.0
26.40
Typ.
Max.
Units
220
µF
±1.2
%
15
%
VDC
Internal Capacitor
Conditions
Line Regulation
Min.
±3.0
For VIN Change of 1%
Load Regulation
IOUT = 10% to 100%
10
See Note 1
75
Ripple & Noise (20 MHz)
Temperature Coefficient
Output Short Circuit
%
mV P - P
±0.03
%/°C
Max.
Units
Continuous (Autorecovery)
General
Parameter
Conditions
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Min.
Typ.
60 Seconds
1,500
VDC
500 VDC
1,000
M
100 kHz, 0.1V
20
Switching Frequency
pF
100
300
kHz
Typ.
Max.
Units
EMI Characteristics
Parameter
Conditions
CISPR22/EN 55022 Level B
Radiated
CISPR22/EN 55022 Level B
Electrostatic Discharge (ESD)
EN 61000-4-2 Level B Contact ±8 kV
EMI Compliance, See Note 3
EMC Compliance
Min.
Conducted
Environmental
Parameter
Conditions
Operating Temperature Range
Ambient
Storage Temperature Range
Min.
Typ.
Max.
-40
+25
+85
°C
+125
°C
95
%
-55
Cooling
Units
Free Air Convection
Humidity
RH, Non-condensing
Physical
MicroPower Direct
Case Size
292 Page Street
Suite D
Stoughton, MA 02072
USA
Case Material
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
MTBF
See Mechanical Diagram (Page 2)
Non-Conductive Black Plastic (UL-94V0)
Weight
0.06 Oz (1.8g)
Reliability Specifications
Parameter
Conditions
Min.
MIL HDBK 217F, 25°C, Gnd Benign
Typ.
Max.
3.5
Units
MHours
Absolute Maximum Ratings
Parameter
Conditions
Input Voltage Surge (1 Sec)
Lead Temperature
Min.
Typ.
Max.
5 VDC Input
-0.7
9.0
24 VDC Input
-0.7
30.0
1.5 mm From Case For 10 Sec
300
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
Units
VDC
°C
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
Voltage (VDC)
Nominal
Range
Output
Current (mA)
Voltage
Current
Current
Full-Load No-Load
(VDC)
(mA, Max)
(mA, Min)
Efficiency Fuse Rating
Slow-Blow
(%, Typ)
(mA)
ME205S-05E
5
4.5 - 5.5
506
23
5.0
400.0
40.0
79
1,000
ME224S-05E
24
21.6 - 26.4
105
6
5.0
400.0
40.0
79
250
Notes:
1. When measuring output ripple, it is recommended that an external
1.0 µF to 10 µF ceramic capacitor be placed from the +Vout pin to
the -Vout pin.
2. Operation at no load will not damage these units, however, they may
not meet all specifications.
3. These converters are specified for operation without external components. However, in some applications the addition of input/output
capacitors will enhance stability and reduce output ripple. The simple
connection shown at right will typically meet EN 55022 Class B.
4. It is recommended that a fuse be used on the input of a power
supply for protection. See the Model Selection table above for the
correct rating.
Typical Connection
Derating Curve
VIN
C1
L1
VOUT
C3
5 VDC
24 VDC
4.7 µF/50V
6.8 µH
5 VDC
10 µF
Pin Connections
Pin
Description
Pin
Description
1
-VIN
3
-VOUT
2
+VIN
4
+VOUT
Mechanical Dimensions
Packing Tube Dimensions
Notes:
• Tube length equals 20.866 (530), unit quantity equals 43 pcs.
• Tube length equals 8.661 (220), unit quantity equals 17 pcs.
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
MicroPower Direct
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
• Pin 1 is marked by a “dot” or indentation on the unit
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•