I1500RW Datasheet - Micropower Direct

I1500RW Series
Ultra-Miniature 15W
Wide 2:1 Input Range
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
Input
• 15W Output Power
• 2:1 Input Range
• Ultra- Miniature Case
• Remote On/Off Control
• 1,600 VDC Isolation
• >800 kHour MTBF
• Standard Pin-Out
Parameter
Input Voltage Range
Input Filter
Conditions
Min.
12 VDC Input
9.0
24 VDC Input 18.0
48 VDC input 36.0
LC Filter
Typ.
12.0
24.0
48.0
Max.
18.0
36.0
75.0
Units
Conditions
Typ.
±2.0
±0.5
±1.0
Max.
Units
%
%
%
VDC
Output
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation
Min.
Vin = Min to Max
Iout = 10% to 100%
3.3V, 5V Output Models
12V, 15V Output Models
3.3V, 5V Output Models
12V, 15V Output Models
See Note 2 120
Zener Diode Clamp
Ripple (20 MHz) (Note 1)
Noise (20 MHz) (Note 1)
Output Power Protection
Over Voltage Protection
Temperature Coefficient
Output Short Circuit
75
100
100
125
mV P - P
mV P - P
%
±0.02
Continuous (Autorecovery)
%/ºC
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Conditions
Min.
60 Seconds 1,600
500 VDC
100
100 kHz, 1V
3.3V, 5V Output Models
12V, 15V Output Models
Switching Frequency
Typ.
Max.
1,000
450
300
Units
VDC
M
pF
kHz
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Derating
Humidity
Physical
Case Size
Case Material
Weight
Conditions
Ambient
Case
Min.
-40
Typ.
+25
-55
Free Air Convection
See Curve
RH, Non-condensing
Max.
+85
+105
+105
Units
ºC
ºC
ºC
95
%
1.00 x 1.00 x 0.433 Inches (25.4 x 25.4 x 11.0 mm)
Six-Sided Shielded Aluminum With Non-Conductive Base (UL94-V0)
0.52 Oz (15g)
Reliability Specifications
Parameter
MTBF
Conditions
MIL HDBK 217F, 25ºC, Gnd Benign
Min.
800
Typ.
Max.
Units
kHours
Conditions
12 VDC Input
24 VDC Input
48 VDC Input
1.5 mm From Case For 10 Sec
Min.
-0.7
-0.7
-0.7
Typ.
Max.
20.0
40.0
80.0
300
Units
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
VDC
ºC
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
I1501RW
I1502RW
I1503RW
I1504RW
I1511RW
I1512RW
I1513RW
I1514RW
I1521RW
I1522RW
I1523RW
I1524RW
Voltage (VDC)
Nominal
Range
12
12
12
12
24
24
24
24
48
48
48
48
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
Output
Current (mA)
Full-Load No-Load
1,132
1,404
1,420
1,420
560
702
702
702
287
355
355
355
90
90
50
50
45
45
25
25
28
28
15
15
Voltage
Current
Current
(VDC)
(mA, Max)
(mA, Min)
3.3
5.0
12.0
15.0
3.3
5.0
12.0
15.0
3.3
5.0
12.0
15.0
3,500
3,000
1,250
1,000
3,500
3,000
1,250
1,000
3,500
3,000
1,250
1,000
350
300
125
100
350
300
125
100
350
300
125
100
Notes:
1. When measuring output ripple, it is recommended that an external ceramic capacitor
(approx 0.1 µF) be placed from the +Vout pin to the -Vout pin.
2. Unit recovers automatically from an over power condition once the fault is removed.
3. Operation at no-load will not damage the unit, but they may not meet all specifications.
4. The On/Off Control input
Min
Max
(Pin 3) is referenced to -Vin
5.0 VDC
15.0 VDC
(Pin 1). If it is not used, the On
control pin should be left Off
0.0 VDC
0.3 VDC
open.
In. Current (on)
-1 mA
5. It is recommended that a In. Current (off)
1 mA
fuse be used on the input
of a power supply for protection. See the Model Selection table above for the correct
rating.
Over
Voltage
Efficiency
Protection
(%, Typ)
(VDC)
3.9
6.2
15.0
18.0
3.9
6.2
15.0
18.0
3.9
6.2
15.0
18.0
85
89
88
88
86
89
89
89
84
88
88
88
Capacitive Fuse Rating
Load
Slow-Blow
(µF Max)
(mA)
1,600
1,600
470
330
1,600
1,600
470
330
1,600
1,600
470
330
3,000
3,000
3,000
3,000
1,500
1,500
1,500
1,500
750
750
750
750
Derating Curve
Mechanical Dimensions
Pin Connections
Pin
1
2
3
4
5
6
Function
+Vin
-Vin
Control
+Vout
No Pin
-Vout
Notes:
MicroPower Direct
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
• Pin 1 is marked by a “dot” on the top of the unit
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]