MPM-10IS Series Board Mount, 10W Single & Dual Output AC/DC Power Supplies Key Features: • 10W Output Power • Universal 85-265 VAC Input • EN 60950 Approved • Meets IEC Safety Class II • Industry Standard Pin-Out • Single and Dual Outputs • Meets EN55022 B • >300 kHour MTBF Electrical Specifications Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Parameter Input Voltage Range Input Frequency Input Current Inrush Current EMI Safety Ground Leakage Current Conditions Min. Typ. 85 47 See Model Selection Guide 115 VAC 10.0 230 VAC 20.0 Meets CISPR Pub. 22/FCC Class B 115 VAC 230 VAC Max. 265 440 Units VAC Hz A Pk 0.1 0.3 mA Output Parameter Output Voltage Output Current Output Voltage Accuracy Line Regulation Load Regulation, Single Output Load Regulation, Dual Output Ripple & Noise (20 MHz) Hold-Up Time Temperature Coefficient Over Voltage Protection Short Circuit Protection, Note 3 Overload Protection, Note 4 Conditions Min. Typ. Max. See Model Selection Guide See Model Selection Guide ±1.0 ±2.0 VIN = Min to Max ±0.5 ±1.0 IO = Min to Max ±0.5 ±1.0 IO = Min to Max ±2.5 ±5.0 3.3V & 5.0 VDC Output 1.5 1.8 All Other Outputs 0.8 1.0 115 VAC, 60 Hz 20 ±0.02 Zener Diode Clamp 120 Continuous (Autorecovery) Typ. 120% to 180% of Output Power Units % % % % %VP-P of VO mSec %/°C % of VO General Parameter Isolation Voltage Isolation Test Voltage Isolation Resistance EMI/RFI EMC Compliance Conditions Input to Output Input to Output, Flash Tested For 60S 500 VDC Conducted Electrostatic Discharge (ESD) RF Field Susceptibility Electrical Fast Transients/Bursts On Mains Surge Switching Frequency MicroPower Direct Environmental 292 Page Street Suite D Stoughton, MA 02072 USA Parameter Operating Temperature Range Storage Temperature Range Cooling Humidity T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Min. 3,000 4,700 100 Typ. Max. Units VAC VAC M EN 55022 Level B IEC/EN 61000-4-2 Level 3 IEC/EN61000-4-3 IEC/EN 61000-4-4 Level 3 2 kV IEC/EN 61000-4-5 Level 3 1kV/2 kV 100 kHz Conditions Min. Typ. Max. -25 +25 +71 -40 +85 Free Air Convection (See Derating Curve) RH, Non-condensing 95 Ambient Units °C °C % Physical Case Size Case Material Weight 2.52 x 1.77 x 0.75 Inches (64.0 x 45.0 x 19.0 mm) Non-Conductive Plastic& Fiberglass (UL94-V0) 3.23 Oz (92g) Reliability Specifications Parameter MTBF Safety Standards Safety Approvals Safety Class Conditions Min. Typ. MIL HDBK 217F, 25°C, Gnd Benign 300 IEN 60950, IEC 60950 IEN 60950, IEC 60950 IEC 61140 Class II Max. Units kHours Model Selection Guide Input Model Number Output 1 (Vout 1) Current (A) Voltage Output 2 (Vout 2) Current (A) Current (A) Voltage (µF, Max) Efficiency (%, Typ) 115 VAC 230 VAC (VDC) Max. Min. MPM-10S-03IS 0.137 0.075 3.3 2.000 0.200 3,900 70 MPM-10S-05IS 0.199 0.075 5.0 2.000 0.200 3,300 73 MPM-10S-12IS 0.191 0.075 12.0 0.833 0.083 2,200 76 MPM-10S-15IS 0.191 0.075 15.0 0.666 0.066 2,200 76 MPM-10S-24IS 0.190 0.075 24.0 0.416 0.042 1,000 76 MPM-10D-12IS 0.172 0.075 +12.0 +0.380 +0.038 -12.0 -0.380 -0.038 ±1,000 77 MPM-10D-15IS 0.169 0.075 +15.0 +0.300 +0.030 -15.0 -0.300 -0.030 ±1,000 77 Other output combinations are available Contact the factory for details at: [email protected] (VDC) Capacitive Load Max. Min. Derating Curve Notes: 1. Load regulation is measured for an output change of 0% to 100% at nominal input line. For multiple output models, the loads are balanced. 2. Operation at no-load will not damage these units. However, they may not meet all specifications. 3. Output short circuit protection is provided by a “hiccup mode” circuit. The unit recovers automatically when the fault condition is removed. 4. Output overload protection is provided by a fold back current limiting circuit. 5. The MPM-10IS series includes a built-in 2A/250 VAC fuse. It is recommended that an external 1.5A slow blow fuse also be used on the input for protection. Mechanical Dimensions Pin Connections Pin Single Dual 1 AC-Neutral AC-Neutral 2 AC-Line AC-Line 3 -Vo -Vo 4 NC Common 5 +Vo +Vo NP = No Connection Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.01 (±0.25) MicroPower Direct www.micropowerdirect.com 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]