MPM-30IS Series Board Mount, 30W Single, Dual & Triple Out AC/DC Power Supplies Key Features: • 30W Output Power • Universal 85-265 VAC Input • EN 60950 Approved (UL) • Meets IEC Safety Class II • Industry Standard Pin-Out • Single, Dual & Triple Outputs • Meets EN 55022 B • >250 kHour MTBF Chassis Mount Models & DIN Rail Mount Option Available! Electrical Specifications Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Parameter Conditions Input Voltage Range Input Frequency Input Current Min. Inrush Current EMI Output Parameter Conditions Output Voltage Output Current Output Voltage Accuracy, Note 1 Line Regulation Load Regulation, Single Output Load Regulation, Dual Output Load Regulation, Triple Output - Primary Load Regulation, Triple Output - Aux. Ripple & Noise (20 MHz) Hold-Up Time Temperature Coefficient Over Voltage Protection Short Circuit Protection, Note 4 Overload Protection, Note 5 General Parameter Isolation Voltage Isolation Test Voltage Isolation Resistance EMI/RFI EMC Compliance Environmental Parameter 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Max. Min. Operating Temperature Range Storage Temperature Range Cooling Humidity Typ. Max. See Model Selection Guide See Model Selection Guide ±1.0 ±2.0 VIN = Min to Max ±0.2 ±1.0 IO = Min to Max ±0.5 ±1.0 IO = Min to Max ±2.5 ±5.0 IO = Min to Max ±2.5 ±5.0 IO = Min to Max ±4.0 3.3 & 5.0 VDC Output 1.5 1.8 All Other Outputs 1.0 1.3 115 VAC, 60 Hz 20 ±0.02 Zener Diode Clamp 120 Continuous (Autorecovery) Typ. 120% to 180% of Output Power Conditions Min. Input to Output Input to Output, Flash Tested For 60S 500 VDC Conducted Electrostatic Discharge (ESD) RF Field Susceptibility Electrical Fast Transients/Bursts On Mains Surge 3,000 4,700 100 Conditions Min. Switching Frequency MicroPower Direct Typ. 85 265 47 440 See Model Selection Guide 115 VAC 20.0 230 VAC 40.0 Meets CISPR Pub. 22/FCC Class B Typ. Max. Units VAC Hz A Pk Units % % % % % % %VP-P of VO mSec %/°C % of VO Units VAC VAC M⍀ EN 55022 Level B EN 61000-4-2 Level B EN 61000-4-3 EN 61000-4-4 Level 3 2 kV EN 61000-4-5 Level 3 1kV/2 kV 100 kHz Typ. Max. Ambient -25 +25 +71 -40 +85 Free Air Convection (See Derating Curve) RH, Non-condensing 95 Units °C °C % Physical Case Size Case Material Weight 3.50 x 2.50 x 0.85 Inches (88.9 x 63.5 x 21.5 mm) Non-Conductive Plastic& Fiberglass (UL94-V0) 6.23 Oz (177g) Reliability Specifications Parameter MTBF Safety Standards Safety Approvals Safety Class Conditions Min. Typ. MIL HDBK 217F, 25°C, Gnd Benign 250 UL 60950, EN 60950 UL, cUL; File No. E245422 IEC 61140 Class II www.micropowerdirect.com Max. Units kHours www.micropowerdirect.com Model Selection Guide Model Number MPM-30S-05IS MPM-30S-12IS MPM-30S-15IS MPM-30S-24IS MPM-30S-48IS MPM-30D-12IS MPM-30D-15IS MPM-30T-0512IS MPM-30T-0512ISA MPM-30T-0515IS MPM-30T-5312IS MPM-30T-3512IS Input Current (A) 115 VAC 230 VAC 0.557 0.14 0.543 0.14 0.543 0.14 0.543 0.14 0.543 0.14 0.565 0.14 0.543 0.14 0.572 0.14 0.572 0.14 0.572 0.588 0.483 Output 1 (Vout 1) Current (A) Voltage (VDC) Max. Min. 5.0 12.0 15.0 24.0 48.0 +12.0 +15.0 5.0 5.0 5.0 5.0 3.3 Other output combinations are available Contact the factory for details at: 6.000 2.500 2.000 1.250 0.625 +1.300 +1.000 3.000 3.000 3.000 4.500 4.000 Output 2 (Vout 2) Current (A) Voltage (VDC) Max. Min. 0.600 0.250 0.200 0.125 0.063 +0.130 +0.100 +0.600 +0.600 +0.300 +0.900 +0.800 -12.0 -15.0 +12.0 +12.0 +15.0 +3.3 +5.0 -1.300 -1.000 +0.600 +1.000 +0.500 +1.000 +1.500 -0.130 -0.100 +0.120 +0.200 +0.050 +0.220 +0.300 Output 3 (Vout 3) Capacitive Efficiency Load Voltage Current (A) (%, Typ) (VDC) (µF, Max) Max. Min. -12.0 -0.600 -12.0 -0.250 -15.0 -0.500 +12.0 +0.250 +12.0 +0.250 -0.120 -0.050 -0.050 +0.050 +0.050 8,000 3,900 3,900 1,500 1,000 ±1,500 ±1,500 See Note 6 See Note 6 See Note 6 See Note 6 See Note 6 78 80 80 80 80 80 80 76 76 76 71 71 Derating Curve [email protected] Notes: 1. For triple output models, the output voltage accuracy of the auxilliary outputs is typically ±4%. 2. Load regulation is measured for an output change of 0% to 100% at nominal input line. For multiple output models, the loads are balanced. 3. Operation at no-load will not damage these units. However, they may not meet all specifications. 4. Output short circuit protection is provided by a “hiccup mode” circuit. The unit recovers automatically when the fault condition is removed. 5. Output overload protection is provided by a fold back current limiting circuit. 6. For triple output models, the maximum capacitive load for 5 VDC and 3.3VDC outputs is 2,200 µF. For all other outputs it is ±1,500 µF. 7. The MPM-30IS series includes a built-in 3.5A/250 VAC fuse. It is recommended that an external 1.5A slow blow fuse also be used on the input for protection. Model Number Mechanical Dimensions Pin Connections Pin Single Dual Triple 1 AC-Neutral 2 AC-Line 3 +Vo +Vo +Vo 2 4 NP NP +Vo 1 5 -Vo Common Common 2/3 6 NP NP -Vo 1 7 NP -Vo +Vo 3 NC = No Connection MicroPower Direct Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.01 (±0.25) We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]