MPM-15CM Datasheet - Micropower Direct

MPM-15CM Series
Chassis Mount, 15W
Single, Dual & Triple Out
AC/DC Power Supplies
Electrical Specifications
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• 15W Output Power
• Universal 85-265 VAC Input
• EN 60950 Approved (UL)
• Single, Dual & Triple Outputs
• Meets EN 55022 B
• Meets IEC Safety Class II
• Chassis Mount Case
PCB Mount Models
& DIN Rail Mount
Option Available!
Input
Parameter
Input Voltage Range
Input Frequency
Input Current
Conditions
Inrush Current
EMI
Min.
Typ.
Max.
85
265
47
440
See Model Selection Guide
115 VAC
15.0
230 VAC
30.0
Meets CISPR Pub. 22/FCC Class B
Units
VAC
Hz
Conditions
Min.
Typ.
Max.
See Model Selection Guide
See Model Selection Guide
±1.0
±2.0
±0.2
±1.0
VIN = Min to Max
IO = Min to Max
±0.5
±1.0
IO = Min to Max
±2.5
±5.0
5.0 VDC Output
1.5
1.8
All Other Outputs
0.8
1.0
115 VAC, 60 Hz
20
±0.02
Zener Diode Clamp
120
Continuous (Autorecovery)
Typ. 120% to 180% of Output Power
Units
A Pk
Output
Parameter
Output Voltage
Output Current
Output Voltage Accuracy
Line Regulation
Load Regulation, Single Output
Load Regulation, Dual, Triple Aux Output
Ripple & Noise (20 MHz)
Hold-Up Time
Temperature Coefficient
Over Voltage Protection
Short Circuit Protection, Note 3
Overload Protection, Note 4
%
%
%
%
%VP-P of VO
mSec
%/°C
% of VO
General
Parameter
Isolation Voltage
Isolation Test Voltage
Isolation Resistance
EMI/RFI
Conditions
Input to Output
Input to Output, Flash Tested For 60S
500 VDC
Conducted
Electrostatic Discharge (ESD)
RF Field Susceptibility
Electrical Fast Transients/Bursts On Mains
Surge
EMC Compliance
Switching Frequency
Min.
3,000
4,700
100
Typ.
Max.
Units
VAC
VAC
M
EN 55022 Level B
EN 61000-4-2 Level B
EN 61000-4-3
EN 61000-4-4 Level 3 2 kV
EN 61000-4-5 Level 3 1kV/2 kV
100
kHz
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size, Chassis Mount
Case Size, DIN Rail Option
Case Material
Weight
Conditions
Min.
Typ.
Max.
-25
+25
+71
-40
+85
Free Air Convection (See Derating Curve)
RH, Non-condensing
95
Ambient
Units
°C
°C
%
3.81 x 2.13 x 0.92 Inches (96.7 x 54.0 x 23.3 mm)
3.81 x 2.13 x 1.35 Inches (96.7 x 54.0 x 34.3 mm)
Non-Conductive Plastic& Fiberglass (UL94-V0)
5.69 Oz (162g)
Reliability Specifications
Parameter
MTBF
Safety Standards
Safety Approvals
Safety Class
Conditions
Min.
Typ.
MIL HDBK 217F, 25°C, Gnd Benign
280
UL 60950, EN 60950
UL, cUL; File No. E245422
IEC 61140 Class II
www.micropowerdirect.com
Max.
Units
kHours
www.micropowerdirect.com
Model Selection Guide
Model
Number
MPM-15S-05CM
MPM-15S-12CM
MPM-15S-15CM
MPM-15S-24CM
MPM-15S-48CM
MPM-15D-12CM
MPM-15D-15CM
MPM-15T-0512CM
MPM-15T-0515CM
Output 2 (Vout 2)
Current (A)
Voltage
(VDC)
Max.
Min.
Input
Current (A)
Output 1 (Vout 1)
Current (A)
Voltage
115 VAC 230 VAC (VDC)
Max.
Min.
0.290
0.275
0.275
0.275
0.273
0.275
0.275
0.290
0.284
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
5.0
12.0
15.0
24.0
48.0
+12.0
+15.0
5.0
5.0
3.000
1.250
1.000
0.625
0.310
+0.625
+0.500
2.000
1.80
Other output combinations are available
Contact the factory for details at:
[email protected]
0.300
0.125
0.100
0.063
0.030
+0.063
+0.050
+0.200
+0.200
-12.0
-15.0
+12.0
+15.0
-0.625
-0.500
+0.200
+0.150
-0.063
-0.050
+0.020
+0.015
Output 3 (Vout 3)
Current (A)
Voltage
(VDC)
Max.
Min.
-12.0
-15.0
-0.200
-0.150
-0.020
-0.015
Capacitive Efficiency
Load
(%, Typ)
(µF, Max)
3,900
2,200
2,200
2,200
1,000
±1,500
±1,500
Note 5
Note 5
75
79
79
79
79
79
79
74
74
Derating Curve
Notes:
1. Load regulation is measured for an output change of 0% to 100% at nominal input
line. For multiple output models, the loads are balanced.
2. Operation at no-load will not damage these units. However, they may not meet all
specifications.
3. Output short circuit protection is provided by a “hiccup mode” circuit. The unit recovers
automatically when the fault condition is removed.
4. Output overload protection is provided by a fold back current limiting circuit.
5. For triple output models, the maximum capacitive load for 5 VDC outputs is 2,200
µF. For all other outputs it is ±1,500 µF.
6. The MPM-15CM series includes a built-in 2.0A/250 VAC fuse. It is recommended
that an external 1.5A slow blow fuse also be used on the input for protection.
Mechanical Dimensions, Chassis Mount
Pin Connections
Pin
Single
Dual
Triple
1
AC-Neutral
2
AC-Line
3
NC
NC
-Vo 3
4
-Vo
-Vo
Common 2/3
5
NC
Common
+Vo 2
6
+Vo
+Vo
-Vo 1
7
NC
NC
+Vo 1
NC = No Connection
Model Number
A DIN Rail mounting kit is available
Contact the factory for details at:
[email protected]
MicroPower Direct
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]