MPM-05MM Series Miniature 1 x 1 Inch 5W, Single Output AC/DC Power Supplies Electrical Specifications Key Features: • 5W Output Power • Miniature 1 x 1 Inch Case • Universal 85-264 VAC Input • EN 60950 Approved • Chassis Mount Option • Meets EN 55022 B • Meets IEC Safety Class II • >1.20 MHour MTBF Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Parameter Conditions Input Voltage Range Input Frequency Input Current Inrush Current, See Note 1 No Load Power Consumption Min. Typ. 85 120 47 See Model Selection Guide 115 VAC 230 VAC See Note 2 Max. 264 370 440 Conditions Min. Typ. See Model Selection Guide See Model Selection Guide Max. Units ±2.0 ±1.0 ±1.0 60 1.0 % % % m V P-P % V P-P of VOUT ±0.05 190 5.0 %/°C %VOUT %VOUT 20.0 40.0 300 Units VAC VDC Hz A Pk mW Output Parameter Output Voltage Output Current Output Voltage Accuracy Line Regulation Load Regulation Ripple & Noise, See Note 3 Hold-Up Time Temperature Coefficient Over Voltage Protection Overshoot Short Circuit Protection, See Note 5 Overload Protection VIN = Min to Max IOUT = 0% to 100% 3.3 & 5 VDC Out Models All Other Models 115 VAC 230 VAC 8.0 40 See Note 4 125 mS Continuous (Autorecovery) See Note 6 135 150 %W General Parameter Isolation Voltage Isolation Resistance Switching Frequency EMI Characteristics Parameter Radiated Emissions Conducted Emissions ESD RS EFT Surge CS PFM Voltage Dips Interruptions MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Conditions Input to Output 500 VDC Min. 3,000 100 Typ. Max. 65 Standard EN 55014, EN 55024 EN 55022 EN 61000-4-2 EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 EN 61000-4-6 EN 61000-4-8 EN 61000-4-11 EN 61000-4-11 Criteria A A A A A A A B Units VAC M kHz Level Class B Class B ±8 kV Air/±4 kV Contact 10V/m ±2 kV ±1 kV 10 Vrms 30A/m 30% 10 mS 95% 500 mS Environmental Parameter Operating Temperature Range Storage Temperature Range Cooling Humidity Conditions Min. Typ. Max. -25 +25 +70 -40 +85 Free Air Convection (See Derating Curve) RH, Non-condensing 95 Ambient Units °C °C % Physical Case Size Case Material See Mechanical Diagram (Page 2) Non-Conductive Black Plastic (UL94-V0) Board Mount 0.69 Oz (19.7g) Chassis Mount 0.85 Oz (19.7g) Weight Reliability Specifications Parameter MTBF Safety Standards Safety Class Conditions Min. Typ. MIL HDBK 217F, 25°C, Gnd Benign 1.20 EN 60950 IEC 60536 Class II www.micropowerdirect.com Max. Units MHours www.micropowerdirect.com Model Selection Guide Model Number MPM-05S-03MM (C) MPM-05S-05MM (C) MPM-05S-09MM (C) MPM-05S-12MM (C) MPM-05S-15MM (C) MPM-05S-24MM (C) MPM-05S-48MM (C) Input Current Output Efficiency Current (mA) (mA Typ) Voltage 115 VAC (VDC) Max. Min. Peak 117 108 106 106 104 104 102 3.3 5.0 9.0 12.0 15.0 24.0 48.0 1,515 1,000 555 416 333 208 104 0.0 0.0 0.0 0.0 0.0 0.0 0.0 1,970 1,300 721 540 433 270 135 Notes: 1. Inrush current is given for a cold start at 25°C. 2. No load power consumption meets the standby power consumption limits in the European ERP Directive 2009/125/EC. 3. Ripple & Noise is specified over a range of 0 - 20 MHz. It is measured with a 1 µF/50V MLCC connected from +VOUT to -VOUT. 4. Over voltage protection is provided by a zener diode clamp. 5. Output short circuit protection is provided by a “hiccup mode” circuit. The unit recovers automatically when the fault condition is removed. 6. Output overload protection is provided by a fold back current limiting circuit with auto-recovery. A long-term overload could damage the unit. 7. Operation at no-load will not damage these units. However, they may not meet all specifications. 8. Peak load is specified as lasting <30s with a maximum duty cycle of 10% The average power should not exceed the maximum power rating. 9. It is recommended that an external slow blow fuse also be used on the input for protection. See the table above for the correct rating. (%, Typ) Fuse Capacitive Rating Load (µF Max) Slow-Blow (mA) 74 80 82 82 83 83 85 2,200 1,000 300 160 100 43 10 Other outputs may be available Contact the factory for details at: [email protected] 1,000 1,000 1,000 1,000 1,000 1,000 1,000 Derating Curve Mechanical Dimensions Board Mount Chassis Mount Pin Connections Pin Function 1 2 3 4 5 AC-Neutral AC-Line No Connection -VOUT +VOUT To order a chassis mount version, add a “C” to the model number (i.e. MPM-05S-15MMC) MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.02 (±0.25) FAX: (781) 344-8481 • E-Mail: [email protected]