MPM-40 Datasheet

MPM-40 Series
Board Mount, 40W
Single, Dual & Triple Out
AC/DC Power Supplies
Key Features:
• 40W Output Power
• Universal 90-264 VAC Input
• EN 60950 Approved (UL)
• Meets IEC Safety Class II
• Industry Standard Pin-Out
• Single, Dual & Triple Outputs
• Meets EN 55022 B
• >200 kHour MTBF
Chassis Mount Models
& DIN Rail Mount
Option Available!
Electrical Specifications
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Conditions
Input Voltage Range
Input Frequency
Input Current
Inrush Current
EMI
Output
Parameter
Output Voltage
Output Current
Output Voltage Accuracy
Line Regulation, See Note 2
Load Regulation, Single Output
Load Regulation, Dual Output, See Note 3
Load Regulation, Triple Output - Primary
Load Regulation, Triple Output - Aux.
Cross Regulation, Dual Output, See Note 4
Cross Regulation, Triple Output - Primary
Cross Regulation, Triple Output - Aux.
Ripple & Noise (20 MHz)
Hold-Up Time
Temperature Coefficient
Over Temperature Protection
Over Voltage Protection
Short Circuit Protection, See Note 6
Overload Protection
General
Parameter
Isolation Voltage
Isolation Resistance
EMI/RFI
EMC Compliance
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Switching Frequency
Environmental
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Reliability Specifications
Parameter
MTBF
Safety Standards
Safety Class
Min.
Typ.
90
100
47
See Model Selection Guide
115 VAC
30.0
230 VAC
50.0
Meets CISPR Pub. 22/FCC Class B
Conditions
Min.
Typ.
See Model Selection Guide
See Model Selection Guide
See Note 1
±2.0
VIN = Min to Max
±0.5
IO = 1% to 100%
±1.0
IO = 10% to 100%
±1.0
IO = 10% to 100%
±3.0
IO = 10% to 100%
±7.0
IO = 15% to 100%
±5.0
IO = 15% to 100%
±3.0
IO = 15% to 100%
±7.0
3.3 VDC Output
50.0
All Other Outputs
1.0
115 VAC
15
±0.02
Note 4
100
Zener Diode Clamp
120
Continuous (Autorecovery)
105
120
Conditions
Input to Output
500 VDC
Conducted
Electrostatic Discharge (ESD)
RF Field Susceptibility
Electrical Fast Transients/Bursts On Mains
Surge
Min.
3,000
100
Typ.
Conditions
Min.
-40
Typ.
+25
Max.
264
375
440
A Pk
Max.
Units
%
%
%
%
%
%
%
%
%
mVP-P
%VP-P of VO
mSec
%/°C
°C
% of VO
% of IO
Max.
Units
VAC
M⍀
EN 55022 Level B
EN 61000-4-2 Level B
EN 61000-4-3
EN 61000-4-4 Level 3 2 kV
EN 61000-4-5 Level 3 1kV/2 kV
132
kHz
Max.
+70
+95
-40
+100
Free Air Convection (See Derating Curve)
RH, Non-condensing
95
Ambient
Case
Units
VAC
VDC
Hz
Units
°C
°C
°C
%
3.50 x 2.50 x 0.98 Inches (89.0 x 63.5 x 25.0 mm)
Non-Conductive Plastic& Fiberglass (UL94-V0)
9.85 Oz (280g)
Conditions
Min.
Typ.
MIL HDBK 217F, 25°C, Gnd Benign
200
EN 60950
IEC 61140 Class II
www.micropowerdirect.com
Max.
400
Units
kHours
www.micropowerdirect.com
Model Selection Guide
Model
Number
MPM-40S-03
MPM-40S-05
MPM-40S-09
MPM-40S-12
MPM-40S-15
MPM-40S-24
MPM-40D-05
MPM-40D-12
MPM-40D-15
MPM-40D-0512
MPM-40D-0524
MPM-40T-0512
MPM-40T-0515
Input
Output 1 (Vout 1)
Output 2 (Vout 2)
Output 3 (Vout 3)
Efficiency
Current (A)
Current
Current
Current (A)
Voltage
Voltage
Voltage
(%, Typ)
(VDC)
(VDC)
(VDC)
115 VAC 230 VAC
Max. (A) Min. (%)
Max. (A) Min. (%)
Max. (A) Min. (%)
0.860
0.460
3.3
8.000
1.0
76
0.860
0.460
5.0
8.000
1.0
81
0.860
0.460
9.0
4.444
1.0
83
0.860
0.460
12.0
3.333
1.0
84
0.860
0.460
15.0
2.666
1.0
83
0.860
0.460
24.0
1.667
1.0
83
0.860
0.460
+5.0
+4.000
10.0
-5.0 -4.000
10.0
81
0.860
0.460
+12.0
+1.666
10.0
-12.0 -1.666
10.0
83
0.860
0.460
+15.0
+1.333
10.0
-15.0 -1.333
10.0
83
0.860
0.460
5.0
5.000
25.0
12.0
1.250
25.0
82
0.860
0.460
5.0
5.000
25.0
24.0
0.625
25.0
82
0.860
0.460
+5.0
+5.000
25.0
+12.0 +0.600
25.0
-12.0 -0.600
25.0
82
0.860
0.460
+5.0
+5.000
25.0
+15.0 +0.500
25.0
-15.0 -0.500
25.0
81
Other output combinations are available
Contact the factory for details at:
[email protected]
Derating Curve
Notes:
1. For dual output models MPM-40D-0512 and MPM-40D-0524, output voltage accuracy
is ±3% for ouput 1 and ±5% for output 2. For triple output models, the output voltage
accuracy is ±3% for output 1 and ±5% for output 2 & 3.
2. For the MPM-40D-0512 and MPM-40D-0524, the line regulation of output 2 is specified
at ±5%.
3. For models MPM-40D-05, MPM-40D-12 and MPM-40D-15, load regulation is measured
with balanced loads. For the MPM-40D-0512 and MPM-40D-0524, load regulation is
±2% for output 1 and ±6% for output 2.
4. For the MPM-40D-0512 and MPM-40D-0524, cross regulation is measured for a load
change of 25% to 100%. It is ±1% for output 1 and ±7% for output 2.
5. The overtemperature protection circuit will shut the unit down. The unit will restart when
the operating temperature drops to approximately +80°C.
6. Output short circuit protection is provided by a “hiccup mode” circuit. The unit recovers
automatically when the fault condition is removed.
7. Operation at under no load conditions will not damage these units, however the output
voltage may be unstable. It is recommended that the minimum load values in the table
above be used.
8. The maximum capacitive load for these units ranges from 23,000 µF (MPM-40S-03) to
470 µF (MPM-40S-24). Contact technical sales for information on specific models.
9. It is recommended that a fuse be used on the input of a power supply for protection. For the MPM-40 series, a 2A/250 VAC slow blow should be used.
Mechanical Dimensions
Model Number
Pin Connections
Pin Single
Dual
Dual Seperate
Triple
1
AC-Line
2
AC-Neutral
3
+Vo
+Vo
+Vo 2
+Vo 2
4
No Pin
No Pin
+Vo 1
+Vo 1
5
-Vo
Common
-Vo 2
Common 2/3
6
No Pin
No Pin
-Vo 1
-Vo 1
7
NC
-Vo
No Pin
-Vo 3
NC = No Connection
Dual Separate Models = MPM-40D-0512 & MPM-40D-0524
MicroPower Direct
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]