MPM-40 Series Board Mount, 40W Single, Dual & Triple Out AC/DC Power Supplies Key Features: • 40W Output Power • Universal 90-264 VAC Input • EN 60950 Approved (UL) • Meets IEC Safety Class II • Industry Standard Pin-Out • Single, Dual & Triple Outputs • Meets EN 55022 B • >200 kHour MTBF Chassis Mount Models & DIN Rail Mount Option Available! Electrical Specifications Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Parameter Conditions Input Voltage Range Input Frequency Input Current Inrush Current EMI Output Parameter Output Voltage Output Current Output Voltage Accuracy Line Regulation, See Note 2 Load Regulation, Single Output Load Regulation, Dual Output, See Note 3 Load Regulation, Triple Output - Primary Load Regulation, Triple Output - Aux. Cross Regulation, Dual Output, See Note 4 Cross Regulation, Triple Output - Primary Cross Regulation, Triple Output - Aux. Ripple & Noise (20 MHz) Hold-Up Time Temperature Coefficient Over Temperature Protection Over Voltage Protection Short Circuit Protection, See Note 6 Overload Protection General Parameter Isolation Voltage Isolation Resistance EMI/RFI EMC Compliance MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Switching Frequency Environmental Parameter Operating Temperature Range Operating Temperature Range Storage Temperature Range Cooling Humidity Physical Case Size Case Material Weight Reliability Specifications Parameter MTBF Safety Standards Safety Class Min. Typ. 90 100 47 See Model Selection Guide 115 VAC 30.0 230 VAC 50.0 Meets CISPR Pub. 22/FCC Class B Conditions Min. Typ. See Model Selection Guide See Model Selection Guide See Note 1 ±2.0 VIN = Min to Max ±0.5 IO = 1% to 100% ±1.0 IO = 10% to 100% ±1.0 IO = 10% to 100% ±3.0 IO = 10% to 100% ±7.0 IO = 15% to 100% ±5.0 IO = 15% to 100% ±3.0 IO = 15% to 100% ±7.0 3.3 VDC Output 50.0 All Other Outputs 1.0 115 VAC 15 ±0.02 Note 4 100 Zener Diode Clamp 120 Continuous (Autorecovery) 105 120 Conditions Input to Output 500 VDC Conducted Electrostatic Discharge (ESD) RF Field Susceptibility Electrical Fast Transients/Bursts On Mains Surge Min. 3,000 100 Typ. Conditions Min. -40 Typ. +25 Max. 264 375 440 A Pk Max. Units % % % % % % % % % mVP-P %VP-P of VO mSec %/°C °C % of VO % of IO Max. Units VAC M⍀ EN 55022 Level B EN 61000-4-2 Level B EN 61000-4-3 EN 61000-4-4 Level 3 2 kV EN 61000-4-5 Level 3 1kV/2 kV 132 kHz Max. +70 +95 -40 +100 Free Air Convection (See Derating Curve) RH, Non-condensing 95 Ambient Case Units VAC VDC Hz Units °C °C °C % 3.50 x 2.50 x 0.98 Inches (89.0 x 63.5 x 25.0 mm) Non-Conductive Plastic& Fiberglass (UL94-V0) 9.85 Oz (280g) Conditions Min. Typ. MIL HDBK 217F, 25°C, Gnd Benign 200 EN 60950 IEC 61140 Class II www.micropowerdirect.com Max. 400 Units kHours www.micropowerdirect.com Model Selection Guide Model Number MPM-40S-03 MPM-40S-05 MPM-40S-09 MPM-40S-12 MPM-40S-15 MPM-40S-24 MPM-40D-05 MPM-40D-12 MPM-40D-15 MPM-40D-0512 MPM-40D-0524 MPM-40T-0512 MPM-40T-0515 Input Output 1 (Vout 1) Output 2 (Vout 2) Output 3 (Vout 3) Efficiency Current (A) Current Current Current (A) Voltage Voltage Voltage (%, Typ) (VDC) (VDC) (VDC) 115 VAC 230 VAC Max. (A) Min. (%) Max. (A) Min. (%) Max. (A) Min. (%) 0.860 0.460 3.3 8.000 1.0 76 0.860 0.460 5.0 8.000 1.0 81 0.860 0.460 9.0 4.444 1.0 83 0.860 0.460 12.0 3.333 1.0 84 0.860 0.460 15.0 2.666 1.0 83 0.860 0.460 24.0 1.667 1.0 83 0.860 0.460 +5.0 +4.000 10.0 -5.0 -4.000 10.0 81 0.860 0.460 +12.0 +1.666 10.0 -12.0 -1.666 10.0 83 0.860 0.460 +15.0 +1.333 10.0 -15.0 -1.333 10.0 83 0.860 0.460 5.0 5.000 25.0 12.0 1.250 25.0 82 0.860 0.460 5.0 5.000 25.0 24.0 0.625 25.0 82 0.860 0.460 +5.0 +5.000 25.0 +12.0 +0.600 25.0 -12.0 -0.600 25.0 82 0.860 0.460 +5.0 +5.000 25.0 +15.0 +0.500 25.0 -15.0 -0.500 25.0 81 Other output combinations are available Contact the factory for details at: [email protected] Derating Curve Notes: 1. For dual output models MPM-40D-0512 and MPM-40D-0524, output voltage accuracy is ±3% for ouput 1 and ±5% for output 2. For triple output models, the output voltage accuracy is ±3% for output 1 and ±5% for output 2 & 3. 2. For the MPM-40D-0512 and MPM-40D-0524, the line regulation of output 2 is specified at ±5%. 3. For models MPM-40D-05, MPM-40D-12 and MPM-40D-15, load regulation is measured with balanced loads. For the MPM-40D-0512 and MPM-40D-0524, load regulation is ±2% for output 1 and ±6% for output 2. 4. For the MPM-40D-0512 and MPM-40D-0524, cross regulation is measured for a load change of 25% to 100%. It is ±1% for output 1 and ±7% for output 2. 5. The overtemperature protection circuit will shut the unit down. The unit will restart when the operating temperature drops to approximately +80°C. 6. Output short circuit protection is provided by a “hiccup mode” circuit. The unit recovers automatically when the fault condition is removed. 7. Operation at under no load conditions will not damage these units, however the output voltage may be unstable. It is recommended that the minimum load values in the table above be used. 8. The maximum capacitive load for these units ranges from 23,000 µF (MPM-40S-03) to 470 µF (MPM-40S-24). Contact technical sales for information on specific models. 9. It is recommended that a fuse be used on the input of a power supply for protection. For the MPM-40 series, a 2A/250 VAC slow blow should be used. Mechanical Dimensions Model Number Pin Connections Pin Single Dual Dual Seperate Triple 1 AC-Line 2 AC-Neutral 3 +Vo +Vo +Vo 2 +Vo 2 4 No Pin No Pin +Vo 1 +Vo 1 5 -Vo Common -Vo 2 Common 2/3 6 No Pin No Pin -Vo 1 -Vo 1 7 NC -Vo No Pin -Vo 3 NC = No Connection Dual Separate Models = MPM-40D-0512 & MPM-40D-0524 MicroPower Direct Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.01 (±0.25) We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]