MPM-03 Datasheet - Micropower Direct

MPM-03 Series
Single Output, 3W
Ultra-Miniature DIP
AC/DC Power Supplies
Key Features:
Electrical Specifications
• 3W Output Power
• Universal 85-264 VAC Input
• EN 60950 Approved (UL)
• Meets IEC Safety Class II
• Single Regulated Output
• Meets EN 55022 Class A
• >300 kHour MTBF
• Ultra-Miniature “DIP” Case
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Conditions
Input Voltage Range
Input Frequency
Input Current
Inrush Current
Min.
Typ.
85
110
47
See Model Selection Guide
115 VAC
10.0
230 VAC
20.0
Max.
264
370
63
Conditions
Min.
Typ.
See Model Selection Guide
See Model Selection Guide
See Note 1
±2.0
±0.5
VIN = Min to Max
See Note 3
±1.0
30
230 VAC
50
±0.02
Continuous (Autorecovery)
Max.
Units
VAC
VDC
Hz
A Pk
Output
Parameter
Output Voltage
Output Current
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
Hold-Up Time
Temperature Coefficient
Short Circuit Protection
Over Temperature Protection
60
Units
%
%
%
mV P-P
mSec
%/°C
150
°C
Max.
Units
VAC
M
General
Parameter
Isolation Voltage
Isolation Resistance
EMI Characteristics
Parameter
Radiated Emissions
Conducted Emissions
ESD
RS
EFT
Surge
CS
PFMF
Voltage Dips
Switching Frequency
Conditions
Input to Output
500 VDC
Min.
3,000
100
Typ.
Standard
See Note 4
EN 55022
See Note 4
EN 55022
EN 61000-4-2
EN 61000-4-3
See Note 5
EN 61000-4-4
See Note 5
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
EN 61000-4-11
Min.
Typ.
Min.
-25
Typ.
+25
Max.
Units
Class A
Class A
Criteria B; ±8 kV Air/±6 kV Contact
Criteria A; 10V/m
Criteria B; ±2 kV
Criteria B; ±1 kV /±2 kV
Criteria A; 10 Vrms
Criteria A; 10A/m
Criteria B; 0% - 70%
100
kHz
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Conditions
Max.
+70
+95
-40
+105
Free Air Convection (See Derating Curve)
RH, Non-condensing
95
Ambient
Case
Units
°C
°C
°C
%
Physical
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Case Size
Case Material
Weight
1.46 x 0.90 x 0.59 Inches (37.0 x 23.0 x 15.0 mm)
Non-Conductive Black Plastic (UL94-V0)
0.70 Oz (20g)
Reliability Specifications
Parameter
MTBF
Safety Standards
Safety Class
Conditions
Min.
Typ.
MIL HDBK 217F, 25°C, Gnd Benign
300
EN 60950
IEC 60536 Class II
www.micropowerdirect.com
Max.
Units
kHours
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
MPM-03S-03
MPM-03S-05
MPM-03S-09
MPM-03S-12
MPM-03S-15
MPM-03S-24
Output
Current (A)
115 VAC
0.065
0.065
0.065
0.065
0.065
0.065
230 VAC
0.030
0.030
0.030
0.030
0.030
0.030
Typical Connection
Standby
Power
Voltage
Current
(VDC)
(mA Max.)
(W, Max)
3.3
5.0
9.0
12.0
15.0
24.0
700
600
330
250
200
125
0.25
0.30
0.35
0.35
0.35
0.35
Notes:
1. For the 3.3V output model, Output Accuracy is ±3.0%
2. Operation at no load will not damage the units, however, they may not
meet all specifications.
3. Load regulation is measured for an output change of 10% to 100% at
nominal input line.
4. All units are rated for EN 55022 (CE/RE) class A without external components.
They will meet EN 55022 class B with the addition of the ACFM-01 (or a
similar discrete filter circuit). Contact the factory for more information.
5. To meet the input surge requirements of EN 61000-4-4 (±2 kV) & EN 61000-4-5
(±1 kV /±2 kV), external components are needed. This can be done discretely,
or with the addition of the ACFM-01. Contact the factory for more information.
6. It is recommended that a fuse be used on the input of a power supply for
protection. For the MPM-03S series, a 0.5A/250 VAC slow blow should
be used.
Efficiency
(%, Typ)
63
72
74
76
76
78
The diagram below illustrates a typical application connection of the MPM-03S series. Notes on this circuit (starting with the input circuit) are:
1. It is recommended that an external fuse and NTC be used. The recommended
fuse is a 0.5A/250V slow blow and for the NTC, a 5D-9.
2. An external MOV is recommended on the input to protect the unit in the event
of a surge. A 561KD14 or equivalent is recommended.
3. Recommended output filtering capacitors are:
MPM-03S-03
MPM-03S-05
MPM-03S-09
MPM-03S-12
MPM-03S-15
MPM-03S-24
C1
1.0 µF
1.0 µF
1.0 µF
1.0 µF
1.0 µF
1.0 µF
C2
150 µF
150 µF
120 µF
120 µF
120 µF
68 µF
C3
4.7 µF/400V
4.7 µF/400V
4.7 µF/400V
4.7 µF/400V
4.7 µF/400V
4.7 µF/400V
TVS
SMBJ7.0A
SMBJ7.0A
SMBJ12A
SMBJ20A
SMBJ20A
SMBJ30A
The output filtering capacitor (C2) is a high frequency, low resistance electrolytic
capacitor. Capacitor (C1) is ceramic. Voltage derating of capacitors should be
80% or above.
4. Input noise and surge suppression modules are available for a number of
MPD AC/DC power supplies. An MPM-03S connection with the ACFM-01 is
illustrated in the diagram at left. For pricing or full technical information on
these modules (ACFM-01 and ACFM-02) please contact the factory.
Typical Connection: With ACFM-01 Input Module (See note 4)
Mechanical Dimensions
Derating Curve
Input Voltage Vs Load
Pin Connections
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
MicroPower Direct
Pin
Function
1
AC-Line
3
AC-Neutral
13 No Connection
14
-VOUT
Pin
Function
16
22
26
+VOUT
+VCAP
-VCAP
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]