LDC-120 Series Compact, LED, 150W Constant Current AC/DC Power Supply Key Features: Electrical Specifications Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. • 150W Output Power Input • UL 8750 Approved Parameter • Constant Current Output Input Voltage Range • Active PFC Input Frequency Inrush Current, See Note 1 • 90 - 305 VAC Input • IP65 / IP67 Rated Conditions 230 VAC 115 VAC 230 VAC 264 VAC 0.98 @ 115 VAC 0.95 @ 230 VAC 0.93 @ 264 VAC See Note 2 115 VAC 230 VAC 277 VAC Input Current • Meets EN 55015, EN 61547 • Dimming Function • >50 kHour Life Expectancy • Lightning Surge Protection • Over Volt/Temp Protection Min. 90 127 47 Power Factor Correction Total Harmonic Distortion (THD) Turn On Delay, See Note 3 Leakage Current Typ. Max. 305 431 63 75 1.60 0.80 0.70 Units VAC VDC Hz A Pk A 10 1.5 0.5 % S 0.75 mA Max. Units % % V P-P % mS °C 107 %IOUT Output Parameter Output Current Accuracy Line Regulation Ripple & Noise (20 MHz) Output Ripple Current Hold-Up Time Over Temperature Protection Short Circuit Protection Overload Protection Conditions Min. VIN = Min to Max See Note 4 Typ. ±5.0 ±1.0 2.0 ±5.0 115 VAC 12.0 ±10%, Autorecovery 85 Continuous (Autorecovery) Autorecovery 95 General Parameter Conditions Min. Typ. Max. Units Input to Output 3,750 Input to FG 2,000 VAC Output to FG 500 Input to Output Input to FG 100 M / 500 VDC / 25°C / 70% RH Output to FG Isolation Voltage, 60S Insulation Resistance EMI Characteristics Parameter EMI EMS Surge MicroPower Direct Standard EN 55015; EN 6100-3-2, -3; FCC Part 18; CNS 14115; GB 17743 EN 61547; EN 61000-4-2,-3, -4, -5, -6, -8, -11; GB 17625.1 10 kV (L/N - FG), 5 kV (L-N)/1.2 x 50 µS Environmental 292 Page Street Suite D Stoughton, MA 02072 USA Parameter Operating Temperature Range Storage Temperature Range Cooling Humidity T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Physical Case Size Weight Conditions Min. Typ. Max. -40 +25 +70 -40 +85 Free Air Convection (See Derating Curve on Page 2) RH, Non-condensing 95 Ambient Units °C °C % See Mechanical Diagrams (Page 4) 32.1 Oz (950g) Reliability Specifications Parameter MTBF Life Expectancy Safety Standards Vibration Conditions Min. Typ. Max. Units MIL HDBK 217F, 25°C, Gnd Benign 220 kHours See Note 5 50 kHours UL 8750 Approved, Meets EN 61347, GB 19510.1, GB 19510.14 5 - 500 Hz, 1G , 1 Oct/Min, 2 Cycles, Period for 75 Min. Each Along X, Y, & Z Axis www.micropowerdirect.com www.micropowerdirect.com Model Selection Guide Output Model Number LDC-120-0350 x LDC-120-0500 x LDC-120-0700 x LDC-120-1050 x LDC-120-1400 x LDC-120-2100 x LDC-120-2450 x LDC-120-2800 x LDC-120-3500 x LDC-120-4550 x Current Output Power Adj. Range (mA) Voltage Range (VDC) OVP Level Max (mA) (VDC) (W) 350 500 700 1,050 1,400 2,100 2,450 2,800 3,500 4,550 210 - 350 300 - 500 420 - 700 630 - 1,500 840 - 1,400 1,260 - 2,100 1,470 - 2,450 1,680 - 2,800 2,100 - 3,500 2,730 - 4,550 210 - 430 150 - 300 107 - 215 74 - 148 54 - 108 31 - 58 36 - 49 31 - 42 26 - 35 21 - 27 475 - 495 335 - 355 230 - 240 165 - 175 120 - 130 62 - 80 54 - 73 49 - 65 41 - 55 31 - 37 150 150 150 155 151 122 120 122 122 123 Efficiency (%, Typ) 92 92 92 92 92 91 91 91 91 90 Notes: 1. Inrush current is given for a cold start at 25°C. 2. Total Harmonic Distortion (THD) is specified with an input of 230 VAC/50 Hz at full load. 3. Turn on delay is specified at full load. 4. Ripple & noise is measured at 20 MHz. Connection to the unit is made with a 0.1 µF ceramic capacitor and a 22 µF electrolytic capacitor connected in parallel. 5. Life expectancy is calculated at 230 VAC, full load and a case temp of +70°C. 6. Recovery from an over voltage fault is automatic. Package Type Model LDC-120-xxxx A LDC-120-xxxx B Ingress Protection IP65 IP67 Dimming Function Adjust by internal, variable resistor Adjust by external resistor, DC voltage level or PWM signal Derating Curve: Temperature Efficiency vs Load: LDC-120-3500 292 Page Street Ste D Stoughton, MA 02072 Derating Curve: Input Voltage PFC vs Load: LDC-120-3500 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected] www.micropowerdirect.com Functional Block Diagram Dimming Mode: B Model With the LDC-120 “B” model, the output current level can be adjusted (Dimmed) by three different methods; Resistive, Analog or Digital. Adjustments are made using the +DIM and -DIM inputs. Resistive: Connect a 0.1 to 10 k resistor between the DIM+ (Blue) and DIM- (White) wires Input Frequency 10 k 20 k 30 k 40 k 50 k 60 k 70 k 80 k 90 k 100 k Open Percentage of Rated Current 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 95~105% Analog: Apply 1 VDC to 10 VDC level between the DIM+ (Blue) and DIM- (White) wires Adjust Voltage Percentage of Rated Current 1 VDC 2 VDC 3 VDC 4 VDC 5 VDC 6 VDC 7 VDC 8 VDC 9 VDC 10 VDC Open 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 95~105% Digital: Apply a PWM signal (100 Hz - 3 kHz) between the DIM+ (Blue) and DIM- (White) wires Duty Cycle 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Open Percentage of Rated Current 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 95~105% Notes: 1. The -DIM (White) and -LED (Black) wires should not be connected. 2. The Dimming function will not turn the lighting fixture totally off. For more info on how to do this, please contact the factory MicroPower Direct • 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected] www.micropowerdirect.com Mechanical Dimensions: A Model Wire Connections: Input Wire Connections: Output Color Function Color Function Green/Yellow Brown Blue Field Ground AC-Line AC-Neutral Black Red -LED +LED Mechanical Dimensions: B Model (Dimming Function) Wire Connections: Input Wire Connections: Output Color Function Color Function Green/Yellow Brown Blue Field Ground AC-Line AC-Neutral White Blue -DIM +DIM Black Red -LED +LED MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]