MPM-60PB Datasheet

MPM-60PB Series
Single Output, 60W
Compact “Power Brick”
AC/DC Power Supplies
Key Features:
• 60W Output Power
• High Power Density Case
• Universal 85-265 VAC Input
• EN 60950 Approved (UL)
• -40°C to + 70°C Operation
• Meets EN 55022 B
• 4,000 VAC I/O Isolation
• >130 kHour MTBF
Electrical Specifications
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Conditions
Min.
Typ.
85
100
47
See Model Selection Guide
115 VAC
30.0
230 VAC
50.0
Input Voltage Range
Input Frequency
Input Current
Inrush Current
Leakage Current
EMI
EMC
Output
Parameter
Output Voltage
Output Current
Output Voltage Accuracy
Output Voltage Adjustment
Line Regulation
Load Regulation
Ripple (20 MHz), See Note 1
Noise, See Note 1
Hold-Up Time
Temperature Coefficient
Over Voltage Protection
Short Circuit Protection, See Note 2
Overload Protection
General
Parameter
Isolation Voltage
Isolation Resistance
EMI/RFI
EMC Compliance
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Switching Frequency
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Reliability Specifications
Parameter
MTBF
Safety Standards
Safety Approvals
Max.
265
370
63
Units
VAC
VDC
Hz
A Pk
0.5
mA
Meets CISPR Pub. 22/FCC Class B
Meets EN 55024
Conditions
Min.
Typ.
Max.
See Model Selection Guide
See Model Selection Guide
±2.0
±10.0
±1.0
VIN = Min to Max
±1.0
IO = 5% to 100%
<±0.2% Vout + 40 mV
<±0.5% Vout + 50 mV
115 VAC
10
230 VAC
60
±0.02
Zener Diode Clamp
120
Continuous (Autorecovery)
150
Conditions
Input to Output
Input to FG
Output to FG
500 VDC
Conducted
Electrostatic Discharge (ESD)
RF Field Susceptibility
Electrical Fast Transients/Bursts On Mains
Surge
Min.
4,000
1,500
500
100
Typ.
Max.
Units
%
%
%
%
mVP-P
mVP-P
mSec
%/°C
% of VO
% of IO
Units
VAC
M⍀
EN 55022 Level B
EN 61000-4-2 Level B
EN 61000-4-3
EN 61000-4-4 Level 3 2 kV
EN 61000-4-5 Level 3 1kV/2 kV
100
kHz
Conditions
Min.
Typ.
Max.
-40
+25
+70
-50
+85
Free Air Convection (See Derating Curve)
RH, Non-condensing
95
Ambient
Units
°C
°C
%
4.30 x 2.30 x 1.18 Inches (109.0 x 58.5 x 30.0 mm)
Non-Conductive Plastic & Fiberglass (UL94-V0)
10.92 Oz (310g)
Conditions
Min.
Typ.
MIL HDBK 217F, 25°C, Gnd Benign
130
UL 60950, EN 60950
UL, cUL; File No. E245422
www.micropowerdirect.com
Max.
Units
kHours
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
MPM-60S-05PB
MPM-60S-09PB
MPM-60S-12PB
MPM-60S-15PB
MPM-60S-24PB
MPM-60S-48PB
Current (A)
115 VAC
2.0
2.0
2.0
2.0
2.0
2.0
230 VAC
1.0
1.0
1.0
1.0
1.0
1.0
Notes:
1. Ripple and noise are measured at 20 Mhz
bandwidth with a 0.1µF and a 47 µF capacitor
connected in parallel as close to the unit output
terminals as possible.
2. Output short circuit protection is provided by a “hiccup
mode” circuit. The unit recovers automatically when
the fault condition is removed.
3. Operation at under no load conditions will not damage
these units.
4. It is recommended that a fuse be used on the
input of a power supply for protection. For the
MPM-60PB series, a 4A/250 VAC slow blow
should be used.
Output
Voltage
(VDC)
5.0
9.0
12.0
15.0
24.0
48.0
Maximum
Capacitive
Load
Current
Max. (A)
10.0
6.66
5.00
4.00
2.50
1.25
Min. (%)
1.0
1.0
1.0
1.0
1.0
1.0
Maximum
Efficiency
Output
Power
(%, Typ)
(µF)
80,000
28,000
14,000
12,000
4,000
950
(W)
50.0
60.0
60.0
60.0
60.0
60.0
82
84
86
86
86
86
Derating Curve
Mechanical Dimensions
Pin Connections
Pin
1
2
3
4
5
6
MicroPower Direct
Function
AC-Neutral
AC-Line
FG
+Vout
-Vout
Trim
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]