MPM-60PB Series Single Output, 60W Compact “Power Brick” AC/DC Power Supplies Key Features: • 60W Output Power • High Power Density Case • Universal 85-265 VAC Input • EN 60950 Approved (UL) • -40°C to + 70°C Operation • Meets EN 55022 B • 4,000 VAC I/O Isolation • >130 kHour MTBF Electrical Specifications Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Parameter Conditions Min. Typ. 85 100 47 See Model Selection Guide 115 VAC 30.0 230 VAC 50.0 Input Voltage Range Input Frequency Input Current Inrush Current Leakage Current EMI EMC Output Parameter Output Voltage Output Current Output Voltage Accuracy Output Voltage Adjustment Line Regulation Load Regulation Ripple (20 MHz), See Note 1 Noise, See Note 1 Hold-Up Time Temperature Coefficient Over Voltage Protection Short Circuit Protection, See Note 2 Overload Protection General Parameter Isolation Voltage Isolation Resistance EMI/RFI EMC Compliance MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Switching Frequency Environmental Parameter Operating Temperature Range Storage Temperature Range Cooling Humidity Physical Case Size Case Material Weight Reliability Specifications Parameter MTBF Safety Standards Safety Approvals Max. 265 370 63 Units VAC VDC Hz A Pk 0.5 mA Meets CISPR Pub. 22/FCC Class B Meets EN 55024 Conditions Min. Typ. Max. See Model Selection Guide See Model Selection Guide ±2.0 ±10.0 ±1.0 VIN = Min to Max ±1.0 IO = 5% to 100% <±0.2% Vout + 40 mV <±0.5% Vout + 50 mV 115 VAC 10 230 VAC 60 ±0.02 Zener Diode Clamp 120 Continuous (Autorecovery) 150 Conditions Input to Output Input to FG Output to FG 500 VDC Conducted Electrostatic Discharge (ESD) RF Field Susceptibility Electrical Fast Transients/Bursts On Mains Surge Min. 4,000 1,500 500 100 Typ. Max. Units % % % % mVP-P mVP-P mSec %/°C % of VO % of IO Units VAC M⍀ EN 55022 Level B EN 61000-4-2 Level B EN 61000-4-3 EN 61000-4-4 Level 3 2 kV EN 61000-4-5 Level 3 1kV/2 kV 100 kHz Conditions Min. Typ. Max. -40 +25 +70 -50 +85 Free Air Convection (See Derating Curve) RH, Non-condensing 95 Ambient Units °C °C % 4.30 x 2.30 x 1.18 Inches (109.0 x 58.5 x 30.0 mm) Non-Conductive Plastic & Fiberglass (UL94-V0) 10.92 Oz (310g) Conditions Min. Typ. MIL HDBK 217F, 25°C, Gnd Benign 130 UL 60950, EN 60950 UL, cUL; File No. E245422 www.micropowerdirect.com Max. Units kHours www.micropowerdirect.com Model Selection Guide Input Model Number MPM-60S-05PB MPM-60S-09PB MPM-60S-12PB MPM-60S-15PB MPM-60S-24PB MPM-60S-48PB Current (A) 115 VAC 2.0 2.0 2.0 2.0 2.0 2.0 230 VAC 1.0 1.0 1.0 1.0 1.0 1.0 Notes: 1. Ripple and noise are measured at 20 Mhz bandwidth with a 0.1µF and a 47 µF capacitor connected in parallel as close to the unit output terminals as possible. 2. Output short circuit protection is provided by a “hiccup mode” circuit. The unit recovers automatically when the fault condition is removed. 3. Operation at under no load conditions will not damage these units. 4. It is recommended that a fuse be used on the input of a power supply for protection. For the MPM-60PB series, a 4A/250 VAC slow blow should be used. Output Voltage (VDC) 5.0 9.0 12.0 15.0 24.0 48.0 Maximum Capacitive Load Current Max. (A) 10.0 6.66 5.00 4.00 2.50 1.25 Min. (%) 1.0 1.0 1.0 1.0 1.0 1.0 Maximum Efficiency Output Power (%, Typ) (µF) 80,000 28,000 14,000 12,000 4,000 950 (W) 50.0 60.0 60.0 60.0 60.0 60.0 82 84 86 86 86 86 Derating Curve Mechanical Dimensions Pin Connections Pin 1 2 3 4 5 6 MicroPower Direct Function AC-Neutral AC-Line FG +Vout -Vout Trim Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.01 (±0.25) We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]